Search NASA⌕ Search

SEARCH · Search NASA

Results for “enriched method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Precision and sensitivity of the measurement of 15N enrichment in D-alanine from bacterial cell walls using positive/negative ion mass spectrometry

Sensitive detection of cellular components from specific groups of microbes can be utilized as 'signatures' in the examination of microbial consortia from soils, sediments or biofilms. Utilizing capillary gas chromatography/mass spectrometry and stereospecific derivatizing agents, D-alanine, a component localized in the prokaryotic (bacterial) cell wall, can be detected reproducibly. Enrichments of D-[15N]alanine determined in E. coli grown with [15N]ammonia can be determined with precision at 1.0 atom%. Chemical ionization with methane gas and the detection of negative ions (M - HF)- and (M - F or M + H - HF)- formed from the heptafluorobutyryl D-2 butanol ester of D-alanine allowed as little as 8 pg (90 fmol) to be detected reproducibly. This method can be utilized to define the metabolic activity in terms of 15N incorporation at the level of 10(3)-10(4) cells, as a function of the 15N-14N ratio.

Non-NASA Center↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through a enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through an enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Future Opportunities for LWR Irradiations in US Test Reactors

After several years of relatively low activity in the field of Light Water Reactor (LWR) fuel development, the Department of Energy again began to engage in developing new fuel technologies and irradiation performance data prompted by the Fukushima Daichi nuclear accidents. New competencies for irradiation testing in material test reactors in the United States began to be developed at this time using the Advanced Test Reactor (ATR), High Flux Isotope Reactor (HFIR), Massachusetts Institute of Technology Reactor (MITR), and the Transient Reactor Test Facility (TREAT). Capsules for testing fuel and cladding materials in ATR and HFIR were deployed, a Pressurized Water Reactor (PWR) condition loop for testing fuel rods was established in ATR, cladding corrosion studies were performed using a water loop in MITR, and TREAT pulse testing capabilities were commissioned for fuel rods in water capsules. The more recent and unexpected closure of the Halden Boiling Water Reactor (HBWR) also prompted further investments in Loss of Coolant Accident (LOCA) testing capabilities at TREAT. New configurations of these test devices show further potential in enhanced steam condition control and other investigations are building toward a flowing water loop for testing transient to dryout conditions. The closure of HBWR also prompted a major project currently underway to construct additional water loops in ATR where a novel approach is being pursued to enable Boiling Water Reactor (BWR) conditions. A meaningful collaborative project was awarded to MITR which, amidst an unexpected major overhaul of the reactor, has expanded cladding corrosion test capabilities at MITR. New explorations have led to methods for unique experiments at HFIR including channel box irradiations. New device developments are also bridging toward future potential for instrumented capsule irradiation tests in ATR and HFIR. Finally, a new project referred to as the System Physics Advanced Reactor Critical facility (SPARC) is gaining traction towards a large zero-power reactor able to produce physics validation data for LWR fuel bundle designs with increased enrichment and enhanced absorbers for 24-month operation cycles. This paper provides a brief summary of the status of these irradiation testbed capabilities with an emphasis on current efforts toward future capabilities to obtain new data and maximize the performance potential of LWR fuel technologies.

Woolstenhulme, Nicolas [Idaho National Laboratory ↗

Image-based modeling of coupled electro-chemo-mechanical behavior of Li-ion battery cathode using an interface-modified reproducing kernel particle method

Abstract An interface-modified reproducing kernel particle method (IM-RKPM) is introduced in this work to allow for a direct model construction from image pixels of heterogeneous polycrystalline Li-ion battery microstructures. The interface-modified reproducing kernel (IM-RK) approximation is constructed through scaling of a kernel function by a regularized distance function in conjunction with strategic placement of interface node locations. This leads to RK shape functions with either weak or strong discontinuities across material interfaces, suitable for modeling various interface mechanics. With the placement of a triple junction node and distance-based scaling of kernel functions, the resulting IM-RK shape function also possesses proper discontinuities at the triple junctions. This IM-RK approximation effectively remedies the well-known Gibb’s oscillation in the smooth approximation of discontinuities. Different from the conventional meshfree approaches for interface discontinuities, this IM-RK approach is done without additional degrees of freedom associated with the enrichment functions, and it is formulated with the standard procedures in the RK shape function construction. This work focuses on identifying the accuracy and convergence properties of IM-RKPM for modeling the coupled electro-chemo-mechanical system. A linear patch test is formulated and numerically tested for the electro-chemo-mechanical coupled problem with a Butler–Volmer boundary condition representing the physical conditions in Li-ion battery microstructures. This is followed by verification of the optimal rates of convergence of IM-RKPM for solving the coupled problem with higher order solutions. The image-based modeling of Li-ion battery microstructures in the numerical examples demonstrates the applicability of the proposed method to realistic Li-ion battery materials modeling.

25 ENERGY STORAGE↗

Assessment of pancreas cells

Pancreatic islets were obtained from guinea pig pancreas by the collagenase method and kept alive in tissue culture prior to further studies. Pancreas cell morphology was studied by standard histochemical techniques using light microscopy. Preparative vertical electrophoresis-levitation of dispersed fetal guinea pig pancreas cells was conducted in phosphate buffer containing a heavy water (D20) gradient which does not cause clumping of cells or alter the osmolarity of the buffers. The faster migrating fractions tended to be enriched in beta-cell content. Alpha and delta cells were found to some degree in most fractions. A histogram showing the cell count distribution is included.

Vanoss, C. J.↗

Light Improves Alertness and Mood during the Sleep Inertial Period following Slow Wave Sleep

Introduction: Waking from sleep, especially slow wave sleep (SWS), is associated with reduced alertness known as sleep inertia. Light improves alertness during sleep deprivation and circadian misalignment. In this study, we assessed the efficacy of light to improve alertness and mood immediately after waking from SWS. Methods: Twelve participants kept a sleep schedule of 8.5 h for 5 nights and 5 h for one night prior to the overnight laboratory visit (confirmed by actigraphy). Participants went to bed at their scheduled habitual bedtime in the laboratory and were monitored by standard polysomnography. After at least 5 min of SWS, participants were awoken and exposed to either red ambient light (control) or blue-enriched bright light (light) for 1 h. During this time, participants completed a subjective scale of alertness (Karolinska Sleepiness Scale, KSS) and visual analogue scales (VAS) of mood at 2 min, 17 min, 32 min, and 47 min after waking. Following this sleep inertia measurement period, all lights were turned off and participants were allowed to return to sleep. They were then awoken again from their subsequent SWS period and exposed to the opposite condition (control or light). A linear mixed-effects model with fixed effects of condition, time, and condition*time and a random effect of participant was used to determine the impact of light across the testing period. An average of baseline responses (pre-sleep) was included as a covariate. Results: Compared to the control condition, participants exposed to bright blue-enriched light reported feeling more alert (KSS: F1,77=4.955, p=.029; VASalert: F1,77=8.226, p=.005), more cheerful (VAScheerful: F1,77=8.615, p=.004), less depressed (VASdepressed: F1,77=4.649, p=.034), and less lethargic (VASlethargic: F1,77=5.652, p=.020). Discussion: Exposure to blue-enriched bright light immediately after waking from SWS may help to improve subjective alertness and mood. Future analyses will explore whether these findings extend to effects on cognitive performance.

alertness↗

Better vacuum by removal of diffusion-pump-oil contaminants

The complex problem of why large space simulation chambers do not realize true ultimate vacuum was investigated. Some contaminating factors affecting diffusion pump performance were identified, and some advances in vacuum distillation-fractionation technology were achieved which resulted in a two-decade-or-more lower ultimate pressure. Data are presented to show the overall or individual contaminating effects of commonly used phthalate ester plasticizers of 390 to 530 molecular weight on diffusion pump performance. Methods for removing contaminants from diffusion pump silicone oil during operation and for reclaiming contaminated oil by high-vacuum molecular distillation are described. Conceptual self-cleansing designs and operating procedures are proposed for modifying large diffusion pumps into high-efficiency distillation devices. The potential exists for application of these technological advancements to other disciplines, such as medicine, biomedical materials, metallurgy, refining, and chemical (diffusion-enrichment) processing.

Buggele, A. E.↗

An introduction to Spent Nuclear Fuel decay heat for Light Water Reactors: a review from the NEA WPNCS

This paper summarized the efforts performed to understand decay heat estimation from existing spent nuclear fuel (SNF), under the auspices of the Working Party on Nuclear Criticality Safety (WPNCS) of the OECD Nuclear Energy Agency. Needs for precise estimations are related to safety, cost, and optimization of SNF handling, storage, and repository. The physical origins of decay heat (a more correct denomination would be decay power) are then introduced, to identify its main contributors (fission products and actinides) and time-dependent evolution. Due to limited absolute prediction capabilities, experimental information is crucial; measurement facilities and methods are then presented, highlighting both their relevance and our need for maintaining the unique current full-scale facility and developing new ones. The third part of this report is dedicated to the computational aspect of the decay heat estimation: calculation methods, codes, and validation. Different approaches and implementations currently exist for these three aspects, directly impacting our capabilities to predict decay heat and to inform decision-makers. Finally, recommendations from the expert community are proposed, potentially guiding future experimental and computational developments. One of the most important outcomes of this work is the consensus among participants on the need to reduce biases and uncertainties for the estimated SNF decay heat. If it is agreed that uncertainties (being one standard deviation) are on average small (less than a few percent), they still substantially impact various applications when one needs to consider up to three standard deviations, thus covering more than 95% of cases. The second main finding is the need of new decay heat measurements and validation for cases corresponding to more modern fuel characteristics: higher initial enrichment, higher average burnup, as well as shorter and longer cooling time. Similar needs exist for fuel types without public experimental data, such as MOX, VVER, or CANDU fuels. A third outcome is related to SNF assemblies for which no direct validation can be performed, representing the vast majority of cases (due to the large number of SNF assemblies currently stored, or too short or too long cooling periods of interest). A few solutions are possible, depending on the application. For the final repository, systematic measurements of quantities related to decay heat can be performed, such as neutron or gamma emission. This would provide indications of the SNF decay heat at the time of encapsulation. For other applications (short- or long-term cooling), the community would benefit from applying consistent and accepted recommendations on calculation methods, for both decay heat and uncertainties. This would improve the understanding of the results and make comparisons easier.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Refining Methods to Determine the Isotopic Composition of Uranium Particles by Laser Ablation MC-ICP-MS

We report on efforts to mitigate the generation of isotopic anomalies during the ablation of micrometer-sized uranium oxide particles and analysis by MC-ICP-MS. The results of testing on particles of U200 indicate that laser fluence and frequency can affect isotopic data produced by laser ablation, but no settings were tested that could eradicate the signal spiking effect and generation of anomalous isotopic data for 234U/238U and 236U/238U. These anomalies are more frequent in samples with higher 235U enrichments, which is expected given their higher abundances of 234U and 236U. Of the standards tested here, only U005-A was anomaly-free. Efforts to compare the laser traces for particles with normal and anomalous isotopic compositions showed subtle differences in the behavior of the 234U/238U and 236U/238U ratios. However, it would be challenging to identify anomalous data points from a population of unknowns using this distinction, i.e., this is unlikely to be diagnostic. Thus, using current analytical hardware, we cannot eradicate the signal spiking phenomenon and cannot unambiguously identify isotopic anomalies from laser ablation traces. Ultimately, laser ablation ICP-MS would either require dramatic improvement to the ablation process and generation of more homogenous aerosols and/or improvements to detector electronics to identify and correct for the spiking phenomenon. Even if the reliability of the technique could be improved, a broader question to address is whether current data quality is of a high enough standard for laser ablation MC-ICP-MS to be used as a complementary technique to LG-SIMS for Safeguards.

organic↗

Assessing the Heat Transfer Modeling Capabilities of CFD Software for Involute-Shaped Plate Research Reactors

The ongoing efforts to convert High-Performance Research Reactors (HPRRs) using Highly Enriched Uranium (HEU) to Low-Enriched Uranium (LEU) fuel require reliable thermal–hydraulic assessments of modified core designs. The involute-shaped fuel plates used in several major HPRRs present unique modeling challenges due to their compact core geometries and high heat flux conditions. This study evaluates the capability of three commercial CFD tools, STAR-CCM+, COMSOL, and ANSYS CFX, to predict cladding-to-coolant heat transfer using Reynolds-Averaged Navier–Stokes (RANS) methods within the thermal–hydraulic regimes of involute-shaped plate reactors. Broad sensitivity analysis was conducted across a range of reactor-relevant parameters using two turbulence models (k−ϵ and k−ω SST) and different near-wall treatment strategies. The results were benchmarked against the Sieder–Tate correlation and experimental data from historic studies. The codes produced consistent results, showing good agreement with the empirical correlation of Sieder–Tate and the experimental measurements. The findings support the use of these commercial CFD codes as effective tools for assessing the thermal–hydraulic performance of involute-shaped plate HPRRs and guide future LEU core development.

CFD↗

Process for separating metallic from semiconducting single-walled carbon nanotubes

A method for separating semiconducting single-walled carbon nanotubes from metallic single-walled carbon nanotubes is disclosed. The method utilizes separation agents that preferentially associate with semiconducting nanotubes due to the electrical nature of the nanotubes. The separation agents are those that have a planar orientation, .pi.-electrons available for association with the surface of the nanotubes, and also include a soluble portion of the molecule. Following preferential association of the separation agent with the semiconducting nanotubes, the agent/nanotubes complex is soluble and can be solubilized with the solution enriched in semiconducting nanotubes while the residual solid is enriched in metallic nanotubes.

Sun, Ya-Ping↗

Root growth and development in response to CO2 enrichment

A non-destructive technique (minirhizotron observation tubes) was used to assess the effects of CO2 enrichment on root growth and development in experimental plots in a scrub oak-palmetto community at the Kennedy Space Center. Potential effects of CO2 enrichment on plants have a global significance in light of concerns over increasing CO2 concentrations in the Earth's atmosphere. The study at Kennedy Space Center focused on aboveground physiological responses (photosynthetic efficiency and water use efficiency), effects on process rates (litter decomposition and nutrient turnover), and belowground responses of the plants. Belowground dynamics are an exceptionally important component of total plant response but are frequently ignored due to methodological difficulties. Most methods used to examine root growth and development are destructive and, therefore, severely compromise results. Minirhizotrons allow nondestructive observation and quantification of the same soil volume and roots through time. Root length density and root phenology were evaluated for CO2 effects with this nondestructive technique.

Day, Frank P., Jr.↗

The Optical and Infrared Are Connected

Galaxies are often modeled as composites of separable components with distinct spectral signatures, implying that different wavelength ranges are only weakly correlated. They are not. We present a data-driven model that exploits subtle correlations between physical processes to accurately predict infrared (IR) Wide-field Infrared Survey Explorer (WISE) photometry from a neural summary of optical Sloan Digital Sky Survey spectra. The model achieves accuracies of $χ^{2}_{N} ≈ 1$ for all photometric bands in WISE, as well as good colors. We are able to tightly constrain typically IR-derived properties, e.g., the bolometric luminosities of active galactic nuclei (AGN) and dust parameters such as q PAH . We also test whether current spectral energy distribution (SED) fitting methods reproduce such panchromatic relations, but find their predictions biased and overconfident, likely due to model misspecification, with correlated biases in star-formation rates (SFRs) and AGN luminosities being most evident. To help improve SED models, we determine which features of the optical spectrum are responsible for our improved predictions, and identify several lines (Ca II , Sr II , Fe I , [O II ], and Hα), which point to the complex chronology of star formation and chemical enrichment being incorrectly modeled.

Jespersen, Christian Kragh [Princeton Univ., NJ (U↗

Temporal multi-omic analysis uncovers sex-biased molecular programs underlying skeletal muscle adaptation to endurance training

Background. Exercise training is known to benefit health and reduce disease risk. While adaptations in skeletal muscles are fundamental to many of the health benefits of exercise training, the common and sex-specific molecular regulators that mediate these adaptations remain to be fully elucidated. Methods. To this end, we leveraged skeletal muscle multi-omics data generated by the Molecular Transducers of Physical Activity Consortium (MoTrPAC), where 6 month-old male and female rats endurance trained for 1, 2, 4, or 8 weeks. Our objective was to identify shared and sex-specific multi-omic molecular responses to endurance training in skeletal muscle, and relate them to phenotypic adaptations. Results. We identified largely sexually-conserved transcriptomic and proteomic enrichments in the gastrocnemius, which correlated with skeletal muscle responses from a published exercise study in humans. We uncovered sex-consistent post-translational modifications, including decreased oxidation of MYH2 and deacetylation of the ß-oxidation enzyme HADHA. Pathway enrichment analyses revealed sex-specific remodeling across the acetylome, redox proteome, and phosphoproteome; females decreased mitochondrial protein oxidation and increased mitochondrial cristae proteins, indicative of enhanced redox buffering and mitochondrial efficiency. Despite observed decreases in the oxidation of key mitochondrial proteins, females displayed increases in the oxidation of proteins involved in glucose catabolism relative to males after 8 weeks of training, suggestive of sex-biased subcellular reactive oxygen species generation. Conclusions. This work shows a large portion of the adaptive response to endurance training in skeletal muscle is shared between females and males, while there are distinct and nuanced sex-specific adaptations that are evident, particularly at the level of post-translational regulation.

Many, Gina M.↗

The Doubly Labeled Water Method for Measuring Human Energy Expenditure: Adaptations for Spaceflight

It is essential to determine human energy requirements in space, and the doubly labeled water method has been identified as the most appropriate means of indirect calorimetry to meet this need. The method employs naturally occurring, stable isotopes of hydrogen (H-2, deuterium) and oxygen (O-18) which, after dosing, mix with body water. The deuterium is lost from the body as water while the O-18 is eliminated as both water and CO2. The difference between the two isotope elimination rates is therefore a measure of CO2 production and hence energy expenditure. Spaceflight will present a unique challenge to the application of the doubly labeled water method. Specifically, interpretation of doubly labeled water results assumes that the natural abundance or 'background' levels of the isotopes remain constant during the measurement interval. To address this issue, an equilibration model will be developed in an ongoing ground-based study. As energy requirements of women matched to counterparts in the Astronauts Corps are being determined by doubly labeled water, the baseline isotope concentration will be changed by consumption of 'simulated Shuttle water' which is artificially enriched. One group of subjects will be equilibrated on simulated Shuttle water prior to energy determinations by doubly labeled water while the others will consume simulated Shuttle water after dosing. This process will allow us to derive a prediction equation to mathematically model the effect of changing background isotope concentrations.

Schulz, Leslie O.↗

Star-Exoplanet Interactions: A Growing Interdisciplinary Field in Heliophysics

Traditionally, heliophysics is characterized as the study of the near-Earth space environment, where plasmas and neutral gases originating from the Earth, the Sun, and other solar system bodies interact in ways that are detectable only through in-situ or close-range (usually within ∼10 AU) remote sensing. As a result, heliophysics has data from the space environment around a handful of solar system objects, in particular the Sun and Earth. Comparatively, astrophysics has data from an extensive array of objects, but is more limited in temporal, spatial, and wavelength information from any individual object. Thus, our understanding of planetary space environments as a complex, multi-dimensional network of specific interacting systems may in the past have seemed to have little to do with the highly diverse space environments detected through astrophysical methods. Recent technological advances have begun to bridge this divide. Exoplanetary studies are opening up avenues to study planetary environments beyond our solar system, with missions like Kepler, TESS, and JWST, along with increasing capabilities of ground-based observations. At the same time, heliophysics studies are pushing beyond the boundaries of our heliosphere with Voyager, IBEX, and the future IMAP mission. The interdisciplinary field of star-exoplanet interactions is a critical, growing area of study that enriches heliophysics. A multidisciplinary approach to heliophysics enables us to better understand universal processes that operate in diverse environments, as well as the evolution of our solar system and extreme space weather. The expertise, data, theory, and modeling tools developed by heliophysicists are crucial in understanding the space environments of exoplanets, their host stars, and their potential habitability. The mutual benefit that heliophysics and exoplanetary studies offer each other depends on strong, continuing solar system-focused and Earth-focused heliophysics studies. The heliophysics discipline requires new targeted funding to support inter-divisional opportunities, including small multi-disciplinary research projects, large collaborative research teams, and observations targeting the heliophysics of planetary and exoplanet systems. Here we discuss areas of heliophysics-relevant exoplanetary research, observational opportunities and challenges, and ways to promote the inclusion of heliophysics within the wider exoplanetary community.

heliophysics↗

Energy expenditure in space flight (doubly labelled water method) (8-IML-1)

The objective of the Energy Expenditure in Space Flight (ESS) experiment is to demonstrate and evaluate the doubly labeled water method of measuring the energy expended by crew members during approximately 7 days in microgravity. The doubly labeled water technique determines carbon dioxide production which is then used to calculate energy expenditure. The method relies on the equilibrium between oxygen in respiratory carbon dioxide and oxygen in body water. Because of this equilibrium, the kinetic of water turnover and respiration are interdependent. Under normal conditions, man contains small but significant amounts of deuterium and oxygen 18. Deuterium is eliminated from the body as water while oxygen 18 is eliminated as water and carbon dioxide. The difference in the turnover rates in the two isotopes is proportional to the carbon dioxide production. Deliberately enriching the total body water with both of these isotopes allows the isotope turnovers to be accurately measured in urine, plasma, or saliva samples. The samples are taken to the laboratory for analysis using an ion-ratio spectrometer.

Parsons, Howard G.↗