Search NASA⌕ Search

SEARCH · Search NASA

Results for “error quantification”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

SU-E-I-72: First Experimental Study of On-Board CBCT Imaging Using 2.5MV Beam On a Radiotherapy Linac

Purpose: Varian TrueBeam version 2.0 comes with a new inline 2.5MV beam modality for image guided patient setup. In this work we develop an iterative volumetric image reconstruction technique specific to the beam and investigate the possibility of obtaining metal artifact free CBCT images using the new imaging modality. Methods: An iterative reconstruction algorithm with a sparse representation constraint based on dictionary learning is developed, in which both sparse projection and low dose rate (10 MU/min) are considered. Two CBCT experiments were conducted using the newly available 2.5MV beam on a Varian TrueBeam linac. First, a Rando anthropomorphic head phantom with and without a copper bar inserted in the center was scanned using both 2.5MV and kV (100kVp) beams. In a second experiment, an MRI phantom with many coils was scanned using 2.5MV, 6MV, and kV (100kVp) beams. Imaging dose and the resultant image quality is studied. Results: Qualitative assessment suggests that there were no visually detectable metal artifacts in MV CBCT images, compared with significant metal artifacts in kV CBCT images, especially in the MRI phantom. For a region near the metal object in the head phantom, the 2.5MV CBCT gave a more accurate quantification of the electron density compared with kV CBCT, with a ∼50% reduction in mean HU error. As expected, the contrast between bone and soft-tissue in 2.5MV CBCT decreased compared with kV CBCT. Conclusion: On-board CBCT imaging with the new 2.5MV beam can effectively reduce metal artifacts, although with a reduced softtissue contrast. Combination of kV and MV scanning may lead to metal artifact free CBCT images with uncompromised soft-tissue contrast.

60 APPLIED LIFE SCIENCES↗

Error and uncertainty in Raman thermal conductivity measurements

We investigated error and uncertainty in Raman thermal conductivity measurements via finite element based numerical simulation of two geometries often employed -- Joule-heating of a wire and laser-heating of a suspended wafer. Using this methodology, the accuracy and precision of the Raman-derived thermal conductivity are shown to depend on (1) assumptions within the analytical model used in the deduction of thermal conductivity, (2) uncertainty in the quantification of heat flux and temperature, and (3) the evolution of thermomechanical stress during testing. Apart from the influence of stress, errors of 5% coupled with uncertainties of ±15% are achievable for most materials under conditions typical of Raman thermometry experiments. Error can increase to >20%, however, for materials having highly temperature dependent thermal conductivities or, in some materials, when thermomechanical stress develops concurrent with the heating. A dimensionless parameter -- termed the Raman stress factor -- is derived to identify when stress effects will induce large levels of error. Together, the results compare the utility of Raman based conductivity measurements relative to more established techniques while at the same time identifying situations where its use is most efficacious.

36 MATERIALS SCIENCE↗

Quantification of breast arterial calcification using full field digital mammography

Breast arterial calcification is commonly detected on some mammograms. Previous studies indicate that breast arterial calcification is evidence of general atherosclerotic vascular disease and it may be a useful marker of coronary artery disease. It can potentially be a useful tool for assessment of coronary artery disease in women since mammography is widely used as a screening tool for early detection of breast cancer. However, there are currently no available techniques for quantification of calcium mass using mammography. The purpose of this study was to determine whether it is possible to quantify breast arterial calcium mass using standard digital mammography. An anthropomorphic breast phantom along with a vessel calcification phantom was imaged using a full field digital mammography system. Densitometry was used to quantify calcium mass. A calcium calibration measurement was performed at each phantom thickness and beam energy. The known (K) and measured (M) calcium mass on 5 and 9 cm thickness phantoms were related by M=0.964K-0.288 mg (r=0.997 and SEE=0.878 mg) and M=1.004K+0.324 mg (r=0.994 and SEE=1.32 mg), respectively. The results indicate that accurate calcium mass measurements can be made without correction for scatter glare as long as careful calcium calibration is made for each breast thickness. The results also indicate that composition variations and differences of approximately 1 cm between calibration phantom and breast thickness introduce only minimal error in calcium measurement. The uncertainty in magnification is expected to cause up to 5% and 15% error in calcium mass for 5 and 9 cm breast thicknesses, respectively. In conclusion, a densitometry technique for quantification of breast arterial calcium mass was validated using standard full field digital mammography. The results demonstrated the feasibility and potential utility of the densitometry technique for accurate quantification of breast arterial calcium mass using standard digital mammography.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Demonstration of TOFFEE: A Response Uncertainty Quantification Tool

A key characteristic in neutron transport is nuclear data. Cross-section uncertainty is not used in MCNP6.3 to propagate response uncertainty without external analysis. Here, the TOol For Fast Error Estimation (TOFFEE) is a Python-based code developed to automate the propagation of cross-section uncertainty for MCNP evaluations. TOFFEE implements the sandwich rule to calculate the uncertainty from cross sections with sensitivity coefficients from MCNP6.3 and ENDF/B covariance data. In this paper, TOFFEE has been tested with benchmark experiments, and it has been compared to the uncertainty quantification capabilities of Sampler and TSUNAMI, within SCALE, to verify the application’s capabilities.

97 MATHEMATICS AND COMPUTING↗

Gaussian kernel density functions for compositional quantification in atom probe tomography

Highlights: • A methodology for compositional quantification from atom probe tomography is proposed. • A probability density function p(x) given discrete data points is constructed. • Each atom approximated by a Gaussian function with a particular smoothing parameter. • Density Kernel functions are used to find the optimum smoothing parameter. • The method is validated by using simulated data of semiconductor materials. - Abstract: Atom probe tomography (APT) has the ability to identify the nature and position of single atoms in a material with an almost 3D atomic resolution. However, the quantification of the material composition requires an appropriate treatment of the discrete APT data. When the amount of atoms selected to quantify the composition is relatively small, the spatial resolution is enhanced but the statistical error worsens. Conversely, the increase in the number of atoms considered reduces the spatial resolution, but improving the statistics. We have developed a methodology to reach an optimum equilibrium between the positional and the statistical error in an unsupervised form using Gaussian Kernel density functions. The validity of the method has been tested using APT simulated data of semiconductor materials. It has been proved that the chemical quantification in these materials requires the appropriate selection of the smoothing parameter, obtained without user intervention. In addition, the results have been compared to the usual techniques for composition measurement from APT data (voxelization and proximity histograms), showing better precision for high spatial resolution. This work supplies a data driven methodology based in Gaussian Kernel density functions for the accurate quantification of the composition from APT data.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Convergence of Probability Densities Using Approximate Models for Forward and Inverse Problems in Uncertainty Quantification

Here, we analyze the convergence of probability density functions utilizing approximate models for both forward and inverse problems. We consider the standard forward uncertainty quantification problem where an assumed probability density on parameters is propagated through the approximate model to produce a probability density, often called a push-forward probability density, on a set of quantities of interest (QoI). The inverse problem considered in this paper seeks to update an initial probability density assumed on model input parameters such that the subsequent push-forward of this updated density through the parameter-to-QoI map matches a given probability density on the QoI. We prove that the densities obtained from solving the forward and inverse problems, using approximate models, converge to the true densities as the approximate models converge to the true models. Numerical results are presented to demonstrate convergence rates of densities for sparse grid approximations of parameter-to-QoI maps and standard spatial and temporal discretizations of PDEs and ODEs.

97 MATHEMATICS AND COMPUTING↗

Early calendar life and health prediction of silicon batteries via machine learning with uncertainty quantification

Lithium-ion batteries with silicon anodes promise high energy density but are limited by calendar lifetime. Reducing the long iteration time to obtain experimental results requires predicting calendar lifetime early in a cell's life. In this study, we demonstrate that lightweight machine learning models with feature engineering can provide calendar lifetime estimates from early electrochemical signals. After 1 month of electrochemical aging, the best models achieve 10% error in calendar-life prediction and can separate "bad" from "good" lifetime cells with a mean F1 score of 0.857. As battery systems exhibit inherent variability, four methods for uncertainty quantification are compared, and confidence intervals are demonstrated with an uncertainty of +-3.6 months in lifetime prediction. A feature importance analysis indicates that early patterns in voltage decay are the strongest indicators of calendar lifetime. Finally, this modeling approach has high error when generalizing to new electrode chemistries or testing conditions but with appropriately low confidence.

25 ENERGY STORAGE↗

Overview of ASME V&V 20-2009 standard for verification and validation in computational fluid mechanics and heat transfer.

The objective of this Standard is the specification of a verification and validation approach that quantifies the degree of accuracy inferred from the comparison of solution and data for a specified variable at a specified validation point. The approach uses the concepts from experimental uncertainty analysis to consider the errors and uncertainties in both the solution and the data. The scope of this Standard is the quantification of the degree of accuracy of simulation of specified validation variables at a specified validation point for cases in which the conditions of the actual experiment are simulated. Consideration of solution accuracy at points within a domain other than the validation points, for example interpolation/extrapolation in a domain of validation, is a matter of engineering judgment specific to each family of problems and is beyond the scope of this Standard.

97 MATHEMATICS AND COMPUTING↗

Uncertainty quantification and optimization of precipitating hydrometeor parameters for winter precipitation in a cloud microphysics scheme

The precipitating hydrometeor parameters used in cloud microphysics schemes carry inherent uncertainties. The quantification of these uncertainties, together with parameter optimization, can significantly improve precipitation forecasts. This study investigates the effects of 13 parameters in the Weather Research and Forecasting (WRF) Double-Moment 6-class (WDM6) microphysics scheme, which define the hydrometeor characteristics such as fall velocity–diameter and mass–diameter relationships, as well as the shape parameter of the drop size distribution for precipitating particles such as rain, snow, and graupel on simulated winter precipitation. A comparison between the model's pre-defined parameters and observations from the International Collaborative Experiments for the PyeongChang 2018 Olympic and Paralympic winter games (ICE-POP 2018) field campaign reveals that the fall velocity–diameter relationship for rain, the mass–diameter relationships for snow and graupel, and the shape parameters for all precipitating particles in the WDM6 scheme deviate from the median values observed by the two-dimensional video disdrometer (2DVD). To quantify parameter sensitivities, a perturbed parameter ensemble (PPE) of 256 simulations was conducted within parameter ranges constrained by 2DVD observations for three winter precipitation cases. Bayesian optimization was then applied to identify parameter sets that minimized the root mean square error (RMSE) for each case, achieving reductions of up to 30.2 %. These results demonstrate that ensemble-based uncertainty quantification and parameter optimization can help identify key parameters and provide a pathway to improving precipitation simulation performance. In addition, measurement sites can be strategically selected based on regions that show high sensitivity to variations in hydrometeor characteristic parameters.

Bayesian optimization↗

Enabling phase quantification of anhydrous cements via Raman imaging

The phase composition of Portland cements is typically determined using conventional techniques like X-ray Diffraction (XRD) Rietveld analysis, optical microscopy point counting, and electron microscopy. However, these techniques have several limitations that may affect their accuracy in certain sample-specific scenarios. Here, we report a highly accurate phase quantification of 11 different types of commercial, anhydrous cements using a new and complementary technique: Raman imaging. Specifically, for the 4 principal phases, composition from our extensive data (250,000 Raman spectra per sample, error < 0.71%) and those obtained from XRD Rietveld and supplier data have high coefficients of determination (R{sup 2} > 0.98, mean deviation <2%). Additionally, we also quantify 8 secondary phases present in cement clinkers (gypsum, anhydrite, bassanite, syngenite, dolomite, calcite, quartz, and portlandite) with a high degree of confidence, thereby demonstrating that Raman imaging is a highly versatile tool for anhydrous phase quantification in a broad variety of cements.

36 MATERIALS SCIENCE↗

Projection-Based Model Reduction for Coupled Conduction—Enclosure Radiation Systems

We report a projection-based reduced order model (pROM) methodology has been developed for transient heat transfer problems involving coupled conduction and enclosure radiation. The approach was demonstrated on two test problems of varying complexity. The reduced order models demonstrated substantial speedups (up to 185×) relative to the full order model with good accuracy (less than 3% L ∞ error). An attractive feature of pROMs is that there is a natural error indicator for the ROM solution: the final residual norm at each time-step of the converged ROM solution. Using example test cases, we discuss how to interpret this error indicator to assess the accuracy of the ROM solution. The approach shows promise for many-query applications, such as uncertainty quantification and optimization. The reduced computational cost of the ROM relative to the full-order model (FOM) can enable the analysis of larger and more complex systems as well as the exploration of larger parameter spaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Correction to: Clinical Quantification of Myocardial Blood Flow Using PET: Joint Position Paper of the SNMMI Cardiovascular Council and the ASNC

The above position statement originally published containing errors in the author metadata; specifically, the Expert Content Reviewers—Andrew Einstein, Raymond Russell and James R. Corbett—were tagged as full authors of the paper. The article metadata has now been corrected to remove Drs. Einstein, Russell and Corbett from the author line, and the PubMed record has been updated accordingly.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A bootstrapping approach to social media quantification

Abstract This work considers the use of classifiers in a downstream aggregation task estimating class proportions, such as estimating the percentage of reviews for a movie with positive sentiment. We derive the bias and variance of the class proportion estimator when taking classification error into account to determine how to best trade off different error types when tuning a classifier for these tasks. Additionally, we propose a method for constructing confidence intervals that correctly adjusts for classification error when estimating these statistics. We conduct experiments on four document classification tasks comparing our methods to prior approaches across classifier thresholds, sample sizes, and label distributions. Prior approaches have focused on providing the most accurate point estimate while this work focuses on the creation of correct confidence intervals that appropriately account for classifier error. Compared to the prior approaches, our methods provide lower error and more accurate confidence intervals.

96 KNOWLEDGE MANAGEMENT AND PRESERVATION↗

Short RNA indicator sequences are not completely degraded by autoclaving

Short indicator RNA sequences (,100 bp) persist after autoclaving and are recovered intact by molecular amplification. Primers targeting longer sequences are most likely to produce false positives due to amplification errors easily verified by melting curves analyses. If short indicator RNA sequences are used for virus identification and quantification then post autoclave RNA degradation methodology should be employed, which may include further autoclaving.

59 BASIC BIOLOGICAL SCIENCES↗

Statistical uncertainties of a chiral interaction at next-to-next-to leading order

In this paper, we have quantified the statistical uncertainties of the low-energy coupling-constants (LECs) of an optimized nucleon–nucleon interaction from chiral effective field theory at next-to-next-to-leading order. Finally, in addition, we have propagated the impact of the uncertainties of the LECs to two-nucleon scattering phase shifts, effective range parameters, and deuteron observables.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Assessment of Flow-Enhanced Electrochemical Sensor Testing and Deployments for MSRs

This report serves as the deliverable for Milestone M3RS-23AN0401061 that is part of Work Package RS-23AN040106 (Flow Enhanced Sensors for MSRs – ANL). The goal of this milestone was to determine performance of the flow enhanced electrochemical sensor (FEES) and modular flow instrumentation testbed (MFIT) in safeguards relevant scenarios. Flow enhanced electrochemical sensors are a type of electroanalytical sensor that has been developed at Argonne National Laboratory to be installed directly into MSR flow conduits to make measurements of the salt composition. These sensors represent a significant improvement in capabilities compared to earlier electroanalytical sensors that instead can only be operated in quiescent conditions. Previous work has focused on testing of the FEES in flowing conditions provided by the MFIT to assess the accuracy and precision of the sensor measurements. To further improve this capability, in FY23 we undertook a campaign of safeguards relevant scenarios in molten salt containing a range of uranium chloride concentrations (0 to 3 wt%). All the testing carried out in FY23 was aided by a control system designed to automatically actuate flow conditions and collect data. This new automation system is estimated to have increased experimental throughput by a factor of four and enabled testing in a variety of complex conditions. The advancements in throughput and repeatability led to improved quantification of actinide concentrations using the in-flow sensors, with a reduction of the mean absolute relative error from 5.6% in FY22 to 3.1% in FY23. In addition to safeguards scenarios run in the MFIT, FY23 work included deployment of a FEES at a partner institution where it will be tested in a flowing salt loop. The FEES was successfully integrated into that loop and is being tested prior to loop startup. In FY23, work also continued on the smaller flow system that we have named the mini-MFIT. This smaller system is capable of rapid prototyping of new sensor designs prior to installation in the larger MFIT radiological flow system. Work was carried out to test this new system in non-radiological molten salts in a separate glovebox. This work is helping us to enhance the accuracy of our salt monitoring capabilities through the integration of multiple types of sensors. The high degree of accuracy required by 10 CFR 74 represents a significant challenge, and further design evolution and integration of the sensors into multimodal sensing frameworks will be needed to further push the measurement accuracy to the needed level.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ensemble Solar Forecasting Statistical Quantification and Sensitivity Analysis

Uncertainties associated with solar forecasts present challenges to maintain grid reliability, especially at high solar penetrations. This study aims to quantify the errors associated with the day-ahead solar forecast parameters and the theoretical solar power output for a 51-kW solar power plant in a utility area in the state of Vermont, U.S. Forecasts were generated by three numerical weather prediction (NWP) models, including the Rapid Refresh, the High Resolution Rapid Refresh, and the North American Model, and a machine-learning ensemble model. A photovoltaic (PV) performance model was adopted to calculate theoretical solar power generation using the forecast parameters (e.g., irradiance, cell temperature, and wind speed). Errors of the power outputs were quantified using statistical moments and a suite of metrics, such as the normalized root mean squared error (NRMSE). In addition, the PV model's sensitivity to different forecast parameters was quantified and analyzed. Results showed that the ensemble model yielded forecasts in all parameters with the smallest NRMSE. The NRMSE of solar irradiance forecasts of the ensemble NWP model was reduced by 28.10% compared to the best of the three NWP models. Further, the sensitivity analysis indicated that the errors of the forecasted cell temperature attributed only approximately 0.12% to the NRMSE of the power output as opposed to 7.44% from the forecasted solar irradiance.

14 SOLAR ENERGY↗

Sparsifying priors for Bayesian uncertainty quantification in model discovery

We propose a probabilistic model discovery method for identifying ordinary differential equations governing the dynamics of observed multivariate data. Our method is based on the sparse identification of nonlinear dynamics (SINDy) framework, where models are expressed as sparse linear combinations of pre-specified candidate functions. Promoting parsimony through sparsity leads to interpretable models that generalize to unknown data. Instead of targeting point estimates of the SINDy coefficients, we estimate these coefficients via sparse Bayesian inference. The resulting method, uncertainty quantification SINDy (UQ-SINDy), quantifies not only the uncertainty in the values of the SINDy coefficients due to observation errors and limited data, but also the probability of inclusion of each candidate function in the linear combination. UQ-SINDy promotes robustness against observation noise and limited data, interpretability (in terms of model selection and inclusion probabilities) and generalization capacity for out-of-sample forecast. Sparse inference for UQ-SINDy employs Markov chain Monte Carlo, and we explore two sparsifying priors: the spike and slab prior, and the regularized horseshoe prior. UQ-SINDy is shown to discover accurate models in the presence of noise and with orders-of-magnitude less data than current model discovery methods, thus providing a transformative method for real-world applications which have limited data.

97 MATHEMATICS AND COMPUTING↗