Search NASA⌕ Search

SEARCH · Search NASA

Results for “estimating guidelines”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Exponential concentration in quantum kernel methods

Kernel methods in Quantum Machine Learning (QML) have recently gained significant attention as a potential candidate for achieving a quantum advantage in data analysis. Among other attractive properties, when training a kernel-based model one is guaranteed to find the optimal model’s parameters due to the convexity of the training landscape. However, this is based on the assumption that the quantum kernel can be efficiently obtained from quantum hardware. In this work we study the performance of quantum kernel models from the perspective of the resources needed to accurately estimate kernel values. We show that, under certain conditions, values of quantum kernels over different input data can be exponentially concentrated (in the number of qubits) towards some fixed value. Thus on training with a polynomial number of measurements, one ends up with a trivial model where the predictions on unseen inputs are independent of the input data. We identify four sources that can lead to concentration including expressivity of data embedding, global measurements, entanglement and noise. For each source, an associated concentration bound of quantum kernels is analytically derived. Lastly, we show that when dealing with classical data, training a parametrized data embedding with a kernel alignment method is also susceptible to exponential concentration. Our results are verified through numerical simulations for several QML tasks. Altogether, we provide guidelines indicating that certain features should be avoided to ensure the efficient evaluation of quantum kernels and so the performance of quantum kernel methods.

97 MATHEMATICS AND COMPUTING↗

Data and Scripts associated with “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling.”

This data package is associated with the publication “Lambda-PFLOTRAN: Workflow for Incorporating Organic Matter Chemistry Informed by Ultra High Resolution Mass Spectrometry into Biogeochemical Modeling” submitted to Geoscientific Model Development (Muller et al., 2024). In this manuscript, organic matter chemistry and thermodynamics are directly connected to reactive transport simulators through the newly developed Lambda-PFLOTRAN (Parallel Reactive Flow and Transport model) workflow tool that succinctly incorporates organic matter chemistry data generated from Fourier transform ion cyclotron resonance mass spectrometry (FTICR-MS) into reaction networks to simulate aerobic respiration of the organic matter and the resulting biogeochemistry. Lambda-PFLOTRAN is a python-based workflow, executed through a Jupyter Notebook interface, that digests raw FTICR-MS data, develops a representative reaction network based on substrate-explicit thermodynamic modeling (also termed lambda modeling due to its key thermodynamic parameter λ used therein), and completes a biogeochemical simulation with the open source, reactive flow, and transport code PFLOTRAN. This data package contains Jupyter Notebook based workflows for two test cases for running biogeochemical simulations of organic matter oxidation identified by FTICR-MS. It contains four primary folders (workflow, data, src, and analysis), a file-level metadata file (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_flmd.csv) that lists all the files contained in this data package with a short description of each, and a data dictionary (Muller_2024_Lambda_PFLOTRAN_Manuscript_Data_Package_dd.csv) file that describes the tabular column headers. The ‘workflow’ folder contains the Jupyter Notebook based workflows for running the lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘data’ folder contains the FTICR-MS data, initial conditions, and incubation data for test cases 1 and 2 in folders titled ‘WHONDRS’ and ‘Colloids’, respectively. The data folder also has a ‘Database’ folder containing a reaction network for bulk organic matter (assumed to be CH2O) and a general database for PFLOTRAN (hanford_rxn_network). The CH2O reaction network defines bulk organic matter oxidation. Biogeochemical simulations are completed for both the lambda binned organic matter and bulk organic matter reaction networks. The ‘hanford_rxn_network’ database includes information required for PFLTORAN simulations including ion size, molar mass, and charge of the aqueous species, gases, and minerals phases. The ‘src’ folder contains python source codes for performing lambda analysis, PFLOTRAN simulation, sensitivity analysis and parameter estimation. The ‘analysis’ folder contains outputs from the test cases 1 and 2 including lambda analysis, PFLOTRAN runs and the calibration results.

54 ENVIRONMENTAL SCIENCES↗

Venous Gas Embolism: Review to Quantify a Safe Volume of Air in Intravenous Fluids Bags for Spaceflight Applications

INTRODUCTION: The ability to create intravenous fluids (IVF) in-situ from the potable water supply of a spaceflight vehicle or habitat is a desired capability for an exploration medical system. In order to define an acceptable volume of air in IVF bags, an understanding of the volume of venous gas embolism as it relates to negative outcomes is needed. The purpose of this study is to review the literature to determine if there is a known volume of gas that contributes to mortality and/or morbidity that could be used to define requirements for rapid IVF infusion in microgravity. METHODS: A literature review was conducted of the PubMed database using the syntax: (Venous) AND (Gas OR Air) AND (Embolism) AND (Morbidity) AND (Mortality) AND (Volume) as well as manual review of references from relevant articles. 151 articles were screened excluding partial text and pediatric articles. Studies were reviewed for identification of volume of venous gas embolism associated with morbidity and/or mortality, which identified 27 articles. RESULTS: Reviewed literature included animal studies, case reports, and review articles. A high variation of proposed volumes contributing to mortality was reported. The limited human data values ranged from 20 ml to 200 ml of infused air with mortality estimated to be 48 – 80%. No studies evaluated human morbidity in any capacity. DISCUSSION: The lack of consensus on the safe volume of infused air has potential ramifications for IVF use in spaceflight as current technologies to create IVF from potable water may introduce air in IVF bags. While current microgravity infusion protocols call for the use of inline air removal filters, commercially available options have flow rate limitations that preclude rapid infusion in a resuscitation scenario. Such filters may be used in parallel to increase flow rate, but the time required to set up such a system may exclude its use during a medical emergency. Additionally, these consumable filters drive up the overall mass and volume of the medical system. Identification of a safe volume of air in IVF would allow for guidelines for the in-situ production of IVF in future spaceflight vehicles/habitats.

Christopher R Woodard↗

Results From Mars Show Electrostatic Charging of the Mars Pathfinder Sojourner Rover

Indirect evidence (dust accumulation) has been obtained indicating that the Mars Pathfinder rover, Sojourner, experienced electrostatic charging on Mars. Lander camera images of the Sojourner rover provide distinctive evidence of dust accumulation on rover wheels during traverses, turns, and crabbing maneuvers. The sol 22 (22nd Martian "day" after Pathfinder landed) end-of-day image clearly shows fine red dust concentrated around the wheel edges with additional accumulation in the wheel hubs. A sol 41 image of the rover near the rock "Wedge" (see the next image) shows a more uniform coating of dust on the wheel drive surfaces with accumulation in the hubs similar to that in the previous image. In the sol 41 image, note particularly the loss of black-white contrast on the Wheel Abrasion Experiment strips (center wheel). This loss of contrast was also seen when dust accumulated on test wheels in the laboratory. We believe that this accumulation occurred because the Martian surface dust consists of clay-sized particles, similar to those detected by Viking, which have become electrically charged. By adhering to the wheels, the charged dust carries a net nonzero charge to the rover, raising its electrical potential relative to its surroundings. Similar charging behavior was routinely observed in an experimental facility at the NASA Lewis Research Center, where a Sojourner wheel was driven in a simulated Martian surface environment. There, as the wheel moved and accumulated dust (see the following image), electrical potentials in excess of 100 V (relative to the chamber ground) were detected by a capacitively coupled electrostatic probe located 4 mm from the wheel surface. The measured wheel capacitance was approximately 80 picofarads (pF), and the calculated charge, 8 x 10(exp -9) coulombs (C). Voltage differences of 100 V and greater are believed sufficient to produce Paschen electrical discharge in the Martian atmosphere. With an accumulated net charge of 8 x 10(exp -9) C, and average arc time of 1 msec, arcs can also occur with estimated arc currents approaching 10 milliamperes (mA). Discharges of this magnitude could interfere with the operation of sensitive electrical or electronic elements and logic circuits. Sojourner rover wheel tested in laboratory before launch to Mars. Before launch, we believed that the dust would become triboelectrically charged as it was moved about and compacted by the rover wheels. In all cases observed in the laboratory, the test wheel charged positively, and the wheel tracks charged negatively. Dust samples removed from the laboratory wheel averaged a few ones to tens of micrometers in size (clay size). Coarser grains were left behind in the wheel track. On Mars, grain size estimates of 2 to 10 mm were derived for the Martian surface materials from the Viking Gas Exchange Experiment. These size estimates approximately match the laboratory samples. Our tentative conclusion for the Sojourner observations is that fine clay-sized particles acquired an electrostatic charge during rover traverses and adhered to the rover wheels, carrying electrical charge to the rover. Since the Sojourner rover carried no instruments to measure this mission's onboard electrical charge, confirmatory measurements from future rover missions on Mars are desirable so that the physical and electrical properties of the Martian surface dust can be characterized. Sojourner was protected by discharge points, and Faraday cages were placed around sensitive electronics. But larger systems than Sojourner are being contemplated for missions to the Martian surface in the foreseeable future. The design of such systems will require a detailed knowledge of how they will interact with their environment. Validated environmental interaction models and guidelines for the Martian surface must be developed so that design engineers can test new ideas prior to cutting hardware. These models and guidelines cannot be validated without actual flighata. Electrical charging of vehicles and, one day, astronauts moving across the Martian surface may have moderate to severe consequences if large potential differences develop. The observations from Sojourner point to just such a possibility. It is desirable to quantify these results. The various lander/rover missions being planned for the upcoming decade provide the means for doing so. They should, therefore, carry instruments that will not only measure vehicle charging but characterize all the natural and induced electrical phenomena occurring in the environment and assess their impact on future missions.

Kolecki, Joseph C.↗

Structural, Criticality, and Radiation Dose Calculations to Support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m-long and 45.7-cm-diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at INL’s CPP-603 facility. The ISS includes a 316L stainless-steel basket that holds 12 PB2 SNF rods. The PB2 basket rests on top of six individual, 78.7-cm-long, 316L stainless-steel columns that are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister above the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture Version 6.2, including ENDF/B-V continuous-energy cross-section libraries, considering intact SNF in a single storage overpack or two multistorage overpack configurations and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and a 27-group neutron-source spectrum were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of 1 m from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Furthermore, this study provides confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Structural, Criticality, and Radiation Dose Calculations to support SNF Loading into a DOE Standard Canister

The DOE Standard Canister Demonstration Project includes the development of an internal support structure (ISS) for the 4.6-m long and 45.7-cm diameter canister. This study presents structural evaluations, criticality safety assessments, and dose rate calculations conducted within the scope of the ISS design process to support smooth canister loading operations and to ensure safe storage, transportation, and disposal of Peach Bottom 1 Core II (PB2) and Fort St. Vrain (FSV) SNF, currently stored at the CPP-603 facility of the INL. The ISS includes a 316L stainless steel basket that holds twelve PB2 SNF rods. Further, six individual, 78.7-cm long, 316L stainless steel columns are equally spaced and welded to the inner canister wall at the lower end of the shell. These columns represent the FSV basket and can hold one FSV SNF element. An A92014 T6 aluminum spacer disc is bolted to the bottom plate of the PB2 basket to vertically restrain the FSV SNF element after the PB2 basket is placed inside the canister on top of the FSV basket. The structural evaluations of the ISS followed applicable ASME BPVC.III.3 guidelines and included finite element (FE) analyses of the PB2 basket structure; analyses of welds and bolds; buckling analyses of selected components, and acceptability assessments of the expected basket deformations under loading operations. The criticality safety assessments used the Monte Carlo N-Particle (MCNP) software architecture version 6.2 including ENDF/B-V continuous energy cross-section libraries, considering intact SNF in a single storage overpack or two multi-storage overpack configurations, and intact or failed SNF configured for disposal. The dose rate computations are based on source terms taken from the DOE Spent Fuel Database. The isotopic composition was decay corrected for the year 2022 using the ORIGEN module in the SCALE suite. A 19-group photon spectrum and 27-group neutron-source spectra were generated and used in MCNP to calculate estimated dose-equivalent rates, both on DOE Standard Canister contact and at a radial distance of from the canister surface. The results of this study indicate a structurally sound system that can uphold its criticality safety functions throughout its intended operational phases. Further, they increase confidence that sufficient radiological protection is technically achievable.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Document-Based Nuclear Archaeology

Deeper reductions in the nuclear arsenals will require better understanding of historic fissile material management and production. The concept of “nuclear archaeology” has been considered since the 1990s to provide the tools and methods to develop independent production estimates, primarily based on nuclear forensic techniques. Here, we propose to add a framework for reconstructing the history of a nuclear program that complements traditional nuclear archaeology techniques by examining the role of operating records to support such an effort. As a test case, we use the JEEP II reactor, a 2 MW civilian research reactor at Norway’s Institute for Energy Technology (IFE), in operation for more than fifty years, however, recently shut down permanently. We have collected, analyzed, and started to preserve the reactor’s operating records, which exist on both analog and digital media, and to simulate parts of its history using OpenMC/ONIX neutronics calculations. Here, a particular focus of this project has been on digital data curation and preservation to confirm and maintain the integrity, authenticity, and provenance of these records. In developing guidelines for best practices that conform to existing standards for long-term digital preservation and curation, we hope this project can help lay the basis for future nuclear archaeology efforts to support nuclear arms control and disarmament.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Innovating the next generation of commercial smart building software

Nearly 30% of commercial building energy use is wasted due to equipment faults and HVAC controls problems. The result is increased emissions, compromised comfort and productivity, and less reliable coordination of building power needs with a clean grid. The energy impact alone represents $17 billion in potential savings. Today’s smart building software provides a robust solution to address these operational deficiencies. Energy management and information systems (EMIS) are saving up to 9% on average, with two-year paybacks. They are being incorporated into energy management processes, commissioning services, and utility programs. As effective as they are, two barriers prevent even deeper benefits; limited personnel to fix problems once they are identified, and the expense and time to manually implement changes in control systems. In partnership with the research community, the EMIS industry is developing new capabilities to overcome these barriers. Moving beyond siloed products for either fault detection and diagnostics, or optimal control, these new capabilities empower users to not only automatically identify faults, but also to push corrective action, and control improvements to their buildings. In this paper, several areas for enhancements are documented: ‘one-time’ correction of faults such as setpoints, schedules, and economizer lockouts; short-term active testing for automated proportional integral derivative (PID) loop tuning and functional testing; and continuous supervisory control for demand flexibility and year-round efficiency. Results are presented from a pair of partner implementations out of a dozen providers integrating these enhancements into their products, including field tests from across the country, and insights into operator acceptance and integration into operations and maintenance practices.

Casillas, Armando↗

Collision avoidance in space

Collisions in earth orbital space between operational payloads and various forms of space debris (nonoperational payloads, nonfunctional mission-related objects and fragments resulting from collisions and explosions) are discussed and possible means of avoiding them are considered. From 10,000 to 15,000 objects are estimated to be in earth orbital space, most of which represent spacecraft fragments and debris too small to be detected and tracked by earth-based sensors, and it is considered likely that some of them will be or have already been involved in direct collisions with the ever increasing number of operational satellites and space stations. Means of protecting proposed large space structures and smaller spacecraft from significant damage by larger space objects, particularly in the 400-4000 km altitude range where most debris occurs, include structural redundancy and the double shielding of sensitive components. Other means of collision avoidance are the collection or relocation of satellites, rocket bodies and other objects by the Space Shuttle, the prevention of explosions and the disposal of spent rocket parts by reentry. Finally, a management structure would be required to administer guidelines for the prevention and elimination of space debris.

Kessler, D. J.↗

Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for component-loaded curved orthogrid panels typical of launch vehicle skin structures. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was applied to correlate the measured input sound pressures across the energized panel. This application quantifies the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software developed for the RPTF method allows easy replacement of the diffuse acoustic field with other pressure fields such as a turbulent boundary layer (TBL) model suitable for vehicle ascent. Structural responses using a TBL model were demonstrated, and wind tunnel tests have been proposed to anchor the predictions and provide new insight into modeling approaches for this environment. Finally, design load factors were developed from the measured and predicted responses and compared with those derived from traditional techniques such as historical Mass Acceleration Curves and Barrett scaling methods for acreage and component-loaded panels.

Frady, Gregory P.↗

Vadose and Saturated Zone Flow and Transport Calculations for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington

The purpose of the fate and transport modeling described in this environmental calculation file (ECF) is to evaluate the impacts to groundwater associated with waste disposal operations at Mixed Waste Low-Level Burial Ground (LLBG) Trenches 31 and 34 to satisfy requirements in DOE O 435.1, Radioactive Waste Management. The model integrates the flow and transport in the vadose zone beneath the active trenches with the saturated zone downgradient of the trenches to predict the radionuclide concentration at the point of assessment (POA). DOE M 435.1-1, Radioactive Waste Management Manual, defines the POA as the point of highest projected dose or concentration beyond a 100 m (328 ft) buffer zone surrounding the disposed waste. The modeling is conducted in accordance with the DOE G 435.1, Implementation Guide for Use with DOE M 435.1-1, performance assessment (PA) guidelines. The modeling involves evaluation of the groundwater concentrations and radionuclide arrival times during the 1,000-year compliance and 10,000-year sensitivity-uncertainty periods per DOE O 435.1 and DOE M 435.1. This analysis does not consider radionuclide release during facility operations, only the post-closure impacts of the radionuclides to the environment. The evaluation of potential radiological dose to groundwater receptors caused by releases from a closed facility containing radioactive waste typically includes the following: (1) Release of radionuclides from that facility (2) Transport of those radionuclides through the environment, and (3) Exposure to humans to environmental concentration levels of those radionuclides The fate and transport three-dimensional (3D) model analysis involves the post-closure impacts to the environment of the technetium-99, iodone-129, and uranium (all isotopes in the waste). The residual inventory estimates include several radionuclides, but technetium-99 is typically responsible for almost all of the beta-gamma dose equivalent associated with groundwater (water resources) protection per 40 CFR 141, “National Primary Drinking Water Regulations” (e.g., see the results in WCH-520, Performance Assessment of Environmental Restoration Disposal Facility, Hanford Site, Washington; hereinafter referred to as the ERDF PA), and iodone-129 can also be a significant dose contributor for some waste (e.g., RPP-RPT-59958, Performance Assessment for the Integrated Disposal Facility, Hanford Site, Washington; hereinafter referred to as the IDF PA). Uranium does not typically factor significantly into the impacts to groundwater, even during the 10,000-year sensitivity-uncertainty period, but always remains of interest as a contaminant. This ECF does not address vadose and saturated zone modeling for Trench 94 of the 200 East Area LLBG. Current information confirms the validity of the low corrosion rate of the naval reactor plant carbon steel (HY-80), and the even lower corrosion rate of the nickel-iron-chromium alloy reactor vessel (Inconel Alloy 600) presented in DOE/EIS-0259, Final Environmental Impact Statement on the Disposal of Decommissioned, Defueled Cruiser, Ohio Class, and Los Angeles Class Naval Reactor Plants. Based on these low corrosion rates, the time to breach the reactor vessel to allow release of radionuclides from the activated metal of the reactor vessel internal structure is at least 10,000 years. This time to breach precludes the need to evaluate the vadose and saturated zone transport of contaminants released from the reactor compartment disposal packages in the 200 East Area LLBGs PA (CP-63826, Waste Release Model Package Report for the Active Trenches of the Low-Level Burial Grounds, Hanford Site, Washington).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

On the Viability of Video Imaging in Leak Rate Quantification: A Theoretical Error Analysis

Optical gas imaging through multispectral cameras is a promising technique for mitigation of methane emissions through localization and quantification of emissions sources. While more advanced cameras developed in recent years have led to lower uncertainties in measuring gas concentrations, a systematic analysis of the uncertainties associated with leak rate estimation have been overlooked. We present a systematic categorization of the involved uncertainties with a focus on a theoretical analysis of projection uncertainties that are inherent to this technique. The projection uncertainties are then quantified using Large Eddy Simulation experiments of a point source release into the atmosphere. Our results show that while projection uncertainties are typically about 5% of the emission rate, low acquisition times and observation of the gas plume at small distances from the emission source (<10 m) can amount to errors of about 20%. Further, we found that acquisition times on the order of tens of seconds are sufficient to significantly reduce (>50%) the projection uncertainties. These findings suggest robust procedures on how to reduce projection uncertainties, however, a balance between other sources of uncertainty due to operational conditions and the employed instrumentation are required to outline more practical guidelines.

47 OTHER INSTRUMENTATION↗

Test-Anchored Vibration Response Predictions for an Acoustically Energized Curved Orthogrid Panel with Mounted Components

A rich body of vibroacoustic test data was recently generated at Marshall Space Flight Center for a curved orthogrid panel typical of launch vehicle skin structures. Several test article configurations were produced by adding component equipment of differing weights to the flight-like vehicle panel. The test data were used to anchor computational predictions of a variety of spatially distributed responses including acceleration, strain and component interface force. Transfer functions relating the responses to the input pressure field were generated from finite element based modal solutions and test-derived damping estimates. A diffuse acoustic field model was employed to describe the assumed correlation of phased input sound pressures across the energized panel. This application demonstrates the ability to quickly and accurately predict a variety of responses to acoustically energized skin panels with mounted components. Favorable comparisons between the measured and predicted responses were established. The validated models were used to examine vibration response sensitivities to relevant modeling parameters such as pressure patch density, mesh density, weight of the mounted component and model form. Convergence metrics include spectral densities and cumulative root-mean squared (RMS) functions for acceleration, velocity, displacement, strain and interface force. Minimum frequencies for response convergence were established as well as recommendations for modeling techniques, particularly in the early stages of a component design when accurate structural vibration requirements are needed relatively quickly. The results were compared with long-established guidelines for modeling accuracy of component-loaded panels. A theoretical basis for the Response/Pressure Transfer Function (RPTF) approach provides insight into trends observed in the response predictions and confirmed in the test data. The software modules developed for the RPTF method can be easily adapted for quick replacement of the diffuse acoustic field with other pressure field models; for example a turbulent boundary layer (TBL) model suitable for vehicle ascent. Wind tunnel tests have been proposed to anchor the predictions and provide new insight into modeling approaches for this type of environment. Finally, component vibration environments for design were developed from the measured and predicted responses and compared with those derived from traditional techniques such as Barrett scaling methods for unloaded and component-loaded panels.

Frady, Gregory P.↗

Understanding and Predicting the Process of Software Maintenance Releases

One of the major concerns of any maintenance organization is to understand and estimate the cost of maintenance releases of software systems. Planning the next release so as to maximize the increase in functionality and the improvement in quality are vital to successful maintenance management. The objective of this paper is to present the results of a case study in which an incremental approach was used to better understand the effort distribution of releases and build a predictive effort model for software maintenance releases. This study was conducted in the Flight Dynamics Division (FDD) of NASA Goddard Space Flight Center(GSFC). This paper presents three main results: 1) a predictive effort model developed for the FDD's software maintenance release process; 2) measurement-based lessons learned about the maintenance process in the FDD; and 3) a set of lessons learned about the establishment of a measurement-based software maintenance improvement program. In addition, this study provides insights and guidelines for obtaining similar results in other maintenance organizations.

Basili, Victor↗

Global Premature Mortality By Dust and Pollution PM 2.5 Estimated From Aerosol Reanalysis of the Modern-Era Retrospective Analysis for Research and Applications, Version 2

This study quantifies global premature deaths attributable to long-term exposure of ambient PM 2.5 , or PM 2.5 -attributable mortality, by dust and pollution sources. We used NASA’s Modern-Era Retrospective Analysis for Research and Applications, Version 2 (MERRA-2) aerosol reanalysis product for PM 2.5 and the cause-specific relative risk (RR) from the integrated exposure-response (IER) model to estimate global PM2.5-attributable mortality for five causes of deaths, namely ischaemic heart disease (IHD), cerebrovascular disease (CEV) or stroke, lung cancer (LC), chronic obstructive pulmonary disease (COPD), and acute lower respiratory infection (ALRI). The estimated yearly global PM 2.5 -attributable mortality in 2019 amounts to 2.89 (1.38–4.48) millions, which is composed of 1.19 (0.73–1.84) million from IHD, 1.01 (0.35–1.55) million from CEV, 0.29 (0.11–0.48) million from COPD, 0.23 (0.14–0.33) million from ALRI, and 0.17 (0.04–0.28) million from LC (the numbers in parentheses represent the estimated mortality range due corresponding to RR spread at the 95% confidence interval). The mortality counts vary with geopolitical regions substantially, with the highest number of deaths occurring in Asia. China and India account for 40% and 23% of the global PM 2.5 -attributable deaths, respectively. In terms of sources of PM 2.5 , about 22% of the global all-cause PM 2.5 -attributable deaths are caused by desert dust. The largest dust attribution is 37% for ALRI. The relative contributions of dust and pollution sources vary with the causes of deaths and geographical regions. Enforcing air pollution regulations to transfer areas from PM 2.5 nonattainment to PM2.5 attainment can have great health benefits. Being attainable with the United States air quality standard (AQS) of 15 μg/m 3 globally would have avoided nearly 40% or 1.2 million premature deaths. The most recent update of PM 2.5 guideline from 10 to 5 μg/m 3 by the World Health Organization (WHO) would potentially save additional one million lives. Our study highlights the importance of distinguishing aerodynamic size from geometric size in accurately assessing the global health burden of PM 2.5 and particularly for dust. A use of geometric size in diagnosing dust PM 2.5 from the model simulation, a common approach in current health burden assessment, could overestimate the PM 2.5 level in the dust belt by 40–170%, leading to an overestimate of global all-cause mortality by 1 million or 32%.

PM2.5↗

Evaluation of Steam Cycle Upgrades to Improve the Competitiveness of U.S. Coal Power Plants (Final Scientific / Technical Report)

Increasing the competitiveness of the existing pulverized-coal utility fleet in the United States may be achieved by decreasing heat rate, via increases in steam cycle efficiency through upgraded steam temperatures and use of latest technology available in steam turbine and blading design. The average net plant efficiency of the US coal-fired fleet is approximately 33% (HHV). Plant efficiency increases to approximately 41.4% (HHV) at 1,350°F (732°C) steam temperature. However, achieving these Advanced Ultra-Super Critical (AUSC) steam conditions requires the use of advanced high-temperature materials. While there has been a significant amount of DOE-funded materials R&D, most of the related design work has focused on new (greenfield) units, rather than on opportunities to retrofit this advanced technology to the existing utility fleet. If technology, based upon the advanced materials required for AUSC steam conditions, may be applied to the existing fleet, using an economically viable retrofit, a higher capacity factor can be expected as a result of the increased plant competitiveness. The Electric Power Research Institute (EPRI) was awarded a project by the US Department of Energy to examine the technical and economic feasibility of a series of steam cycle upgrades to the two most prevalent types of U.S. coal power plants: 2,400 psig (16.6 MPa) subcritical and 3,500 psig (24.1 MPa) supercritical pulverized coal units. The nine upgrade options that were originally being considered included increasing the main and reheat steam temperatures from 1,000°F (538°C) to 1,100°, 1,200°, and 1,350°F (593°C, 649°C, and 732°C) while holding the steam pressures constant at their original design values, and cases where just the main steam or reheat steam temperatures were increased. The objective was to minimize the modifications required to the existing power plant while still providing a significant improvement in heat rate. The upgrade options assumed that the boiler enclosure envelope remained unchanged from each base case, and that all applicable OEM design guidelines for normal commercial units were imposed. For the highest temperature supercritical case, an option of using a low-pressure molten salt loop to transfer heat from the furnace to the steam was examined. The first major task of the work scope was designed to examine the technical feasibility of various upgrade options, while the subsequent work determined economic viability of the technically feasible upgrade options. Prior to evaluating the effect of these increased temperatures, a “base case” model of a subcritical and supercritical PC boiler was created, which was used for comparative purposes. Upgrade options were evaluated at full-load, part-load and dynamic transient conditions. Once the technical feasibility of each upgrade option was evaluated, the economic value of the heat rate improvement of each feasible option was determined by detailed modeling of unit dispatch in several regional power markets. The dispatch model was used to estimate the amount of revenue from power sales the upgraded unit would receive in comparison to a non-upgraded version of the same power plant. As a parallel task to the dispatch analysis, the capital cost of implementing the upgrades was estimated. The capital cost estimates were then compared to the increased revenue estimated by the dispatch modeling to determine the economic attractiveness of each upgrade option. Several upgrade options were determined to be technically feasible. The net present value (NPV) of the costs for steam cycle upgrades considered in this study ranged from approximately $\$$111 to $\$$130 million. The economic modeling results show that the unit dispatch changes resulting from steam cycle upgrades are relatively small, due largely to heat rate (and operating cost) changes being relatively small. Additionally, the cost of each upgrade exceeds the net revenue increases associated with the upgrade case. Note that the breakeven values are higher for subcritical retrofits, but the capital costs for the subcritical upgrades are also slightly higher. In typical new pulverized coal plants, fuel accounts for approximately 25% of the cost of electricity (COE), while capital costs represent around 50% of the COE. Therefore, in order to improve the heat rate by 4% one can only afford to increase the capital cost by 2%, at the same cost of electricity. The conclusion of this study is that without a cost for emitting CO 2 , it will be difficult to pay for significant efficiency improvements on plants firing low cost coals.

01 COAL, LIGNITE, AND PEAT↗

Coupled Hydromechanical Modeling and Assessment of Induced Seismicity at FWU: Utilizing Time-Lapse VSP and Microseismic Data

The objective of this work is to utilize integrated geomechanics, field vertical seismic profile (VSP) and microseismic data to characterize the complex subsurface stress conditions at the Farnsworth Unit (FWU). The model is based on a five-spot sector model extracted from a primary geomechanical model. The five-spot well injection pattern is characterized by extensive reservoir characterization data, such well logs, extracted cores and borehole geophone data, to facilitate the detailed examination of stress changes and microseismic event occurrences. The study utilizes field vertical seismic volumes acquired from the injection well 13-10A. The seismic volumes successfully provided snapshots of the behavior of the reservoir at distinct times. The use of VSP and microseismic data provided direct and indirect estimates of the dynamic stress changes occurring in the overburden, reservoir and underburden rock formations. In order to illuminate the stress regions and identify rocks that have undergone inelastic failure, microseismic event occurrences were utilized. Microseismic activity has been detected at the FWU; further study of its locations, timing, and magnitude was needed to deduce the nature of the changing stress state. The results of the study revealed that microseismic events were successfully modeled within the Morrow B formation. Moment magnitudes of seismic events were within the same magnitudes for events in the reservoir, suggesting the suitability of the model. The results of the study showed that the computed moment magnitudes for seismic events were insignificant to warrant safety concerns. The study findings showed the usefulness of coupled hydromechanical models in predicting the subsurface stress changes associated with CO 2 injection. The knowledge gained from this study will serve as a guideline for industries planning to undertake underground CO 2 storage, and characterize the subsurface stress changes.

02 PETROLEUM↗

Photosynthetic and stomatal response, and leaf traits, of two pine species, Talladega National Forest, Alabama, 2023

Photosynthetic response to irradiance (AQ), CO2 (ACi) and stomatal response to irradiance measurements on two pine species common to the southeast United States, long leaf pine, Pinus palustris Mill., and loblolly pine, Pinus taeda L.. Data were collected in June 2023 within the Oakmulgee District of the Talladega National Forest in west-central Alabama at the NEON site (TALL). Measurements were made with four LI-COR LI-6800 and one LI-COR LI-6400XT gas exchange systems. ACi and AQ curves enable the estimation of photosynthetic parameters (e.g., Vcmax, Jmax, Rd, aQY), while stomatal response curves enable the estimation of stomatal slope and intercept parameters. Foliar trait data (needle dimensions, leaf mass per area, leaf nitrogen concentration) is provided for all gas exchange samples. The data package files include multiple raw and processed data files (csv), metadata files (csv), the complete instrument output for all measurements in .zip format, and a pdf describing the experimental protocol.

54 ENVIRONMENTAL SCIENCES↗