Search NASA⌕ Search

SEARCH · Search NASA

Results for “fast camera”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Time-Dependent Phase-Space Mapping of Space-Charge-Dominated Beams

In this paper we report on a proof of principle experiment for demonstrating the possibility of reconstructing the time resolved-phase-space distribution of a space-charge dominated beam by a tomographic technique which provides us with far more information than a time-sliced emittance. We emphasize that this work describes and demonstrates a new methodology which can be applicable to any beam pulse using imaging methods with the appropriate time resolution for the pulse duration. The combination of a high precision tomographic diagnostic with fast imaging screens and a gated camera are used to produce phase space maps of two beams: one with a parabolic current profile and another with a short perturbation atop a rectangular pulse. The correlations between longitudinal and transverse phase spaces are apparent and their impact on the dynamics is discussed.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Injected Beam Dynamics in SPEAR3

For the top-off operation it is important to understand the time evolution of charge injected into the storage ring. The large-amplitude horizontal oscillation quickly filaments and decoheres, and in some cases exhibits non-linear x-y coupling before damping to the stored orbit. Similarly, in the longitudinal dimension, any mismatch in beam arrival time, beam energy or phase-space results in damped, non-linear synchrotron oscillations. In this paper we report on measurements of injection beam dynamics in the transverse and longitudinal planes using turn-by-turn BPMs, a fast-gated, image-intensified CCD camera and a Hamamatsu C5680 streak camera.

43 PARTICLE ACCELERATORS↗

Fast Soft X-ray Images of MHD Phenomena in NSTX

A variety of MHD phenomena have been observed on NSTX. Many of these affect fast particle losses, which are of major concern for future burning plasma experiments. Usual diagnostics for studying these phenomena are arrays of Mirnov coils for magnetic oscillations and PIN diode arrays for soft x-ray emission from the plasma core. Data reported here are from an unique fast soft x-ray imaging camera (FSXIC) with a wide-angle (pinhole) tangential view of the entire plasma minor cross section. The camera provides a 64x64 pixel image, on a CCD chip, of light resulting from conversion of soft x-rays incident on a phosphor to the visible. We have acquired plasma images at frame rates of 1-500 kHz (300 frames/shot), and have observed a variety of MHD phenomena: disruptions, sawteeth, fishbones, tearing modes, and ELMs. New data including modes with frequency > 90 kHz are also presented. Data analysis and modeling techniques used to interpret the FSXIC data are described and compared, and FSXIC results are compared to Mirnov and PIN diode array results.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Time-Resolved X-Ray and Extreme Ultraviolet Spectrometer for Use on the National Spherical Torus Experiment

We describe upgrades to a compact grazing-incidence spectrometer utilized on the National Spherical Torus Experiment (NSTX) for monitoring light and heavy impurities . A fast-readout charge couple device (CCD) camera has been implemented that allows the recording of spectra with up to 25 ms time integration. This capability is used to study the time evolution of the K-shell emission of hydrogenlike and heliumlike boron, carbon, nitrogen, and oxygen between 10 and 65 {angstrom}. Different camera positioning pieces have been employed to extend the possible spectral range to as high as 140. Several lines that cannot be ascribed to the usual elements found in the plasma have been observed in this spectral range, though often only in a few isolated discharges.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Launch Vehicle Loads Analysis Using Pressure-Sensitive Paint

Pressure transducers have been the instrumentation of choice for measuring unsteady flow phenomena. With recent advances in high-speed cameras, high-powered LEDs, and fast-response, pressure-sensitive paint, the unsteady pressure-sensitive paint (uPSP) technique has become a valuable alternative for production wind tunnel facilities, enabling time-resolved measurements of unsteady pressure fluctuations over a dense spatial grid on a wind tunnel model. Launch vehicle ground tests have proven to be a particularly well-matched application for uPSP due to the high signal level relative to tunnel background acoustics, relatively simple camera optical access, and rigidity of the model in wind-on test conditions. This presentation will highlight recent advances in data reduction of uPSP measurement data from recent launch vehicle wind tunnel tests at the NASA Ames Unitary Plan Wind Tunnel Complex (UPWT). The system can provide both localized surface pressure spectra as well as regional or zonal estimates of turbulence correlation model parameters. In addition, integrated vehicle-scale loads can be provided for buffet analysis. Data is reduced at the on-premise NASA Advanced Supercomputer (NAS) Division for just-in-time delivery of results during an ongoing wind tunnel test.

Pressure-Sensitive Paint↗

Launch Vehicle Loads Analysis Using Pressure-Sensitive Paint

Pressure transducers have been the instrumentation of choice for measuring unsteady flow phenomena. With recent advances in high-speed cameras, high-powered LEDs, and fast-response, pressure-sensitive paint, the unsteady pressure-sensitive paint (uPSP) technique has become a valuable alternative for production wind tunnel facilities, enabling time-resolved measurements of unsteady pressure fluctuations over a dense spatial grid on a wind tunnel model. Launch vehicle ground tests have proven to be a particularly well-matched application for uPSP due to the high signal level relative to tunnel background acoustics, relatively simple camera optical access, and rigidity of the model in wind-on test conditions. This presentation will highlight recent advances in data reduction of uPSP measurement data from recent launch vehicle wind tunnel tests at the NASA Ames Unitary Plan Wind Tunnel Complex (UPWT). The system can provide both localized surface pressure spectra as well as regional or zonal estimates of turbulence correlation model parameters. In addition, integrated vehicle-scale loads can be provided for buffet analysis. Data is reduced at the on-premise NASA Advanced Supercomputer (NAS) Division for just-in-time delivery of results during an ongoing wind tunnel test.

pressure-sensitive paint↗

First neutral beam experiments on Wendelstein 7-X

In the previous divertor campaign, the Wendelstein 7-X (W7-X) device injected 3.6 MW of neutral beam heating power allowing for the achievement of densities approaching 2 × 10 20 m -3 , and providing the first initial assessment of fast ion confinement in a drift optimized stellarator. The neutral beam injection (NBI) system on W7-X is comprised of two beam boxes with space for four radio frequency sources each. The 3.6 MW of heating reported in this work was achieved with two sources in the NI21 beam box. The effect of combined electron-cyclotron resonance heating (ECRH) and NBI was explored through a series of discharges varying both NBI and ECRH power. Discharges without ECRH saw a linear increase in the line-integrated plasma density, and strong peaking of the core density, over the discharge duration. The presence of 1 MW of ECRH power was found to be sufficient to control a continuous density rise during NBI operation. Simulations of fast ion wall loads were found to be consistent with experimental infrared camera images during operation. In general, NBI discharges were free from the presence of fast ion induced Alfvénic activity, consistent with low beam betas. These experiments provide data for future scenario development and initial assessment of fast-ion confinement in W7-X, a key topic of the project.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

HST PSF simulation using Tiny Tim

Tiny Tim is a program which simulates Hubble Space Telescope imaging camera PSF's. It is portable (written and distributed in C) and is reasonably fast. It can model the WFPC, WFPC 2, FOC, and COSTAR corrected FOC cameras. In addition to aberrations such as defocus and spherical, it also includes WFPC obscuration shifting, mirror zonal error maps, and jitter. The program has been used at a number of sites for deconvolving HST images. Tiny Tim is available via anonymous ftp on stsci.edu in the directory software/tinytim.

Krist, J. E.↗

Doppler spectroscopy and D-alpha emission diagnostics for the C-2 FRC plasma

Two Doppler spectroscopy diagnostics with complementary capabilities are developed to measure the ion temperatures and velocities of FRC plasmas in the C-2 device. First, the multichord ion doppler diagnostic can simultaneously measure 15 chords of the plasma using an image intensified camera. Second, a single-chord fast-response ion Doppler diagnostic provides much higher faster time response by using a 16-channel photo-multiplier tube array. To study the neutral density of deuterium under different wall and plasma conditions, a highly sensitive eight-channel D-alpha diagnostic has been developed and calibrated for absolute radiance measurements. These spectroscopic diagnostics capabilities, combined with other plasma diagnostics, are helping to understand and improve the field reversed configuration plasmas in the C-2 device.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of a high dynamic range spectroscopic system for observation of neutral hydrogen atom density distribution in Large Helical Device core plasma

We report development of a high dynamic range spectroscopic system comprising a spectrometer with 30% throughput and a camera with a low-noise fast-readout complementary metal-oxide semiconductor sensor. The system achieves a 10{sup 6} dynamic range (∼20 bit resolution) and an instrumental function approximated by a Voigt profile with Gauss and Lorentz widths of 31 and 0.31 pm, respectively, for 656 nm light. The application of the system for line profile observations of the Balmer-α emissions from high temperature plasmas generated in the Large Helical Device is also presented. In the observed line profiles, emissions are detected in far wings more than 1.0 nm away from the line center, equivalent to neutral hydrogen atom kinetic energies above 1 keV. We evaluate atom density distributions in the core plasma by analyzing the line profiles.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatial calibration and synthetic diagnostic of a multi-energy hard x-ray camera at WEST tokamak

WEST (tungsten environment in steady-state tokamak) is starting operation for the first time with a water-cooled full tungsten divertor, enabling long pulse operation. Heating is provided by radiofrequency systems, including lower hybrid current drive (LHCD). In this context, a compact multi-energy hard x-ray camera has been installed for energy and space-resolved measurements of the electron temperature, the fast electron tail density produced by LHCD and runaway electrons, and the beam–target emission of tungsten at the target due to fast electron losses interacting with the divertor plates. The diagnostic is a pinhole camera based on a 2D pixel array detector (Pilatus 3 CdTe CMOS Hybrid-Pixel detector produced by DECTRIS). The novelty of this diagnostic technique is the detector’s capability of adjusting the threshold energy at pixel level. This innovation provides great flexibility in the energy configuration, allowing simultaneous space and energy-resolved x-ray measurements. This contribution details two important steps in the preparation of the diagnostic operation. First, the in-vessel spatial calibration that was carried out with a radioactive source. Second, the synthetic diagnostic is obtained by the suite of codes ALOHA/C3PO/LUKE/R5-X2, which simulates LH wave propagation and absorption, as well as the fast electron bremsstrahlung production.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Visible Light Diagnostics at SPEAR3

The visible light diagnostic beam line at SPEAR3 utilizes dipole radiation extracted through an ID exit port to evaluate electron beam properties at a variety of diagnostic end-stations. The unfocused SR light is collected 17 m from the source point by a 150 mm diameter, f = 2 m lens and optically relayed to the appropriate station. For transverse imaging, an image-intensified PiMax camera with 2 ns gate allows measurement of fast beam dynamics for either the stored beam or the injected beam. For these applications the visible light is switched into either a standard symmetric-lens transport line or a beam-shaping transport line equipped with cylindrical lenses and a rotating mirror to sweep the beam image across the camera photocathode. A separate two slit stellar-interferometer branch line can resolve the diffraction-limited vertical beam height down to about 10 {mu}m. For longitudinal charge profile measurements, the light is switched to a Hamamatsu C5680 streak camera with net system resolution of {approx}2.5 ps rms. In this paper we outline the main photon beam transport line, review the SR beam properties and describe measurement capabilities at each diagnostic station.

43 PARTICLE ACCELERATORS↗

The Effect of Surface Condition on Wetting of HASTELLOY{sup ®} X by Brazing Filler Metal of Ni-Pd-Cr-B-Si System

The paper presents the results of wettability tests by a sessile drop method coupled with residual gas analysis for the HASTELLOY{sup ®} X substrates contact heated with brazing filler metal of Palnicro 36M. The contact angles formed between the substrate and the molten brazing filler metal were recorded by high-speed high-resolution CCD camera using two different heating procedures: (1) fast continuous heating to a temperature of 960 °C; (2) isothermal heating at a temperature of 995 °C for 10 min after step heating to the test temperature. In this study, the reference sample was HASTELLOY{sup ®} X in a delivery state (D1). The base material with a different surface finish was also tested: after polishing (P1), after polishing and oxidation at a temperature of 600 °C for 1 h in the air (U1). The tests confirmed very good wetting properties of Palnicro 36M on HASTELLOY{sup ®} X, independently on its surface finish and the heating procedure used in this study, i.e., after 10 min at 995 °C, the final contact angle values were θ{sub f} = 7.6 ± 0.1°, 6.03 ± 0.07° and 6.2 ± 1.0° for D1, P1 and U1, respectively. However, oxidation of HASTELLOY{sup ®} X surface affects the wetting kinetics and spreading of molten Palnicro 36M on BM substrates by: (1) increasing the initial contact angle values (θ{sub 0} = 51 ± 4°, 65 ± 13° and 83 ± 2° for D1, P1 and U1, respectively), (2) delaying the wetting process and (3) reducing the spreading area since after wettability tests at 960 °C, the largest area covered with solidified Palnicro 36M drop was noted for D1 (92 mm{sup 2}) while the smallest one for U1 (52 mm{sup 2}).

36 MATERIALS SCIENCE↗

Differential Phase-Contrast Scanning X-Ray Microscope For Observation Of Low-Z element Specimen

Differential phase-contrast scanning x-ray microscope/microtomography have been developed. A fast readout charge-coupled device (CCD) camera coupled with a visible-light conversion unit is used as a detector to record the transmitted intensity distribution of far-field image for every pixel in a scan. Simultaneous absorption and phase-contrast images are given from a single scan by image-processing of the CCD frames. The system is constructed at BL20XU of SPring-8, and its feasibility is demonstrated at the photon energy of 8 keV. A tantalum test chart is observed and its finest structure of 140 nm pitch pattern is clearly observed. Measured phase sensitivity is approximately {lambda}/270. Some low-Z element specimens are observed and obtained phase contrast image shows much higher sensitivity than that of absorption contrast.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Upgrade of the lithium beam diagnostic at JET

A 60 kV neutral Li beam is injected into the edge plasma of JET to measure the electron density. The beam observation system has been improved by replacing a Czerny-Turner spectrometer with a high-resolution transmission-grating spectrometer and a fast back-illuminated frame-transfer camera. The larger throughput of the spectrometer, the increased sensitivity, and the faster readout of the new camera allow inter-ELM (edge localized mode) measurements (frame rate of 100 Hz). The calibration of the setup, as well as an improved spectral fitting technique in the presence of carbon background radiation, is discussed in detail. The density calculation is based on a statistical analysis method. Results are presented for different plasma scenarios.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Communication: Time- and space-sliced velocity map electron imaging

We develop a new method to achieve slice electron imaging using a conventional velocity map imaging apparatus with two additional components: a fast frame complementary metal-oxide semiconductor camera and a high-speed digitizer. The setup was previously shown to be capable of 3D detection and coincidence measurements of ions. Here, we show that when this method is applied to electron imaging, a time slice of 32 ps and a spatial slice of less than 1 mm thick can be achieved. Each slice directly extracts 3D velocity distributions of electrons and provides electron velocity distributions that are impossible or difficult to obtain with a standard 2D imaging electron detector.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Note: An improved 3D imaging system for electron-electron coincidence measurements

We demonstrate an improved imaging system that can achieve highly efficient 3D detection of two electrons in coincidence. The imaging system is based on a fast frame complementary metal-oxide semiconductor camera and a high-speed waveform digitizer. We have shown previously that this detection system is capable of 3D detection of ions and electrons with good temporal and spatial resolution. Here, we show that with a new timing analysis algorithm, this system can achieve an unprecedented dead-time (<0.7 ns) and dead-space (<1 mm) when detecting two electrons. A true zero dead-time detection is also demonstrated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗