On-board fault management for autonomous spacecraft

The dynamic nature of the Cargo Transfer Vehicle's (CTV) mission and the high level of autonomy required mandate a complete fault management system capable of operating under uncertain conditions. Such a fault management system must take into account the current mission phase and the environment (including the target vehicle), as well as the CTV's state of health. This level of capability is beyond the scope of current on-board fault management systems. This presentation will discuss work in progress at TRW to apply artificial intelligence to the problem of on-board fault management. The goal of this work is to develop fault management systems. This presentation will discuss work in progress at TRW to apply artificial intelligence to the problem of on-board fault management. The goal of this work is to develop fault management systems that can meet the needs of spacecraft that have long-range autonomy requirements. We have implemented a model-based approach to fault detection and isolation that does not require explicit characterization of failures prior to launch. It is thus able to detect failures that were not considered in the failure and effects analysis. We have applied this technique to several different subsystems and tested our approach against both simulations and an electrical power system hardware testbed. We present findings from simulation and hardware tests which demonstrate the ability of our model-based system to detect and isolate failures, and describe our work in porting the Ada version of this system to a flight-qualified processor. We also discuss current research aimed at expanding our system to monitor the entire spacecraft.

Fesq, Lorraine M.↗

Faulting processes in active faults - Evidences from TCDP and SAFOD drill core samples

The microstructures, mineralogy and chemistry of representative samples collected from the cores of the San Andreas Fault drill hole (SAFOD) and the Taiwan Chelungpu-Fault Drilling project (TCDP) have been studied using optical microscopy, TEM, SEM, XRD and XRF analyses. SAFOD samples provide a transect across undeformed host rock, the fault damage zone and currently active deforming zones of the San Andreas Fault. TCDP samples are retrieved from the principal slip zone (PSZ) and from the surrounding damage zone of the Chelungpu Fault. Substantial differences exist in the clay mineralogy of SAFOD and TCDP fault gouge samples. Amorphous material has been observed in SAFOD as well as TCDP samples. In line with previous publications, we propose that melt, observed in TCDP black gouge samples, was produced by seismic slip (melt origin) whereas amorphous material in SAFOD samples was formed by comminution of grains (crush origin) rather than by melting. Dauphiné twins in quartz grains of SAFOD and TCDP samples may indicate high seismic stress. The differences in the crystallographic preferred orientation of calcite between SAFOD and TCDP samples are significant. Microstructures resulting from dissolution–precipitation processes were observed in both faults but are more frequently found in SAFOD samples than in TCDP fault rocks. As already described for many other fault zones clay-gouge fabrics are quite weak in SAFOD and TCDP samples. Clay-clast aggregates (CCAs), proposed to indicate frictional heating and thermal pressurization, occur in material taken from the PSZ of the Chelungpu Fault, as well as within and outside of the SAFOD deforming zones, indicating that these microstructures were formed over a wide range of slip rates.

Janssen, C.↗

Arc-Fault Primer: Numerical, Analytical, and Experimental Characteristics of Initiation and Sustainment of Arc Plasmas (DRAFT)

While arc-faults are rare in electrical installations, many documented events have led to fires that resulted in significant damage to energy-generation, commercial and residential systems, as well as surrounding structures, in both the United States and abroad. Arc-plasma discharges arise over time due to a variety of reliability issues related to cable material degradation, electrical and mechanical stresses or acute conductive wiring dislocations. These may lead to discontinuity between energized conductors, facilitating arcing events and fires. Arc-flash events rapidly release significant energy in a localized volume, where the electric arc experiences a reduction in resistance. This facilitates a reduction in electrical resistance as the arc temperature and pressure can increase rapidly. Strong pressure waves, electromagnetic interference (EMI), and intense light from an arc pose a threat to electrical worker safety and system equipment. This arc-fault primer provides basic fundamental insight into arc-fault plasma discharges, and an overview of direct current (DC) and alternating current (AC) arc-fault phenomena. This primer also covers pressure waves and EMI arc-fault hazard analyses related to incident energy prediction and potential damage analysis. Mitigation strategies are also discussed related to engineering design and employment of protective devices including arc-fault circuit interrupters (AFCIs). Best practices related to worker safety are also covered, especially as they pertain to electrical codes and standards, particularly Institute of Electrical and Electronics Engineers (IEEE) 1584 and National Fire Protection Agency (NFPA) 70E. Throughout the primer various modelling and test capabilities at Sandia National Laboratories are also covered, especially as they relate to novel methods of arc-fault/arc-flash characterization and mitigation approaches. Herein, this work describes methods for producing and characterizing controlled, sustained arcs at atmospheric pressures as well as methods for mitigation with novel materials.

42 ENGINEERING↗

Galileo spacecraft power distribution and autonomous fault recovery

There is a trend in current spacecraft design to achieve greater fault tolerance through the implemenation of on-board software dedicated to detecting and isolating failures. A combination of hardware and software is utilized in the Galileo power system for autonomous fault recovery. Galileo is a dual-spun spacecraft designed to carry a number of scientific instruments into a series of orbits around the planet Jupiter. In addition to its self-contained scientific payload, it will also carry a probe system which will be separated from the spacecraft some 150 days prior to Jupiter encounter. The Galileo spacecraft is scheduled to be launched in 1985. Attention is given to the power system, the fault protection requirements, and the power fault recovery implementation.

Detwiler, R. C.↗

Method of locating ground faults

The present invention discloses a method of detecting and locating current imbalances such as ground faults in multiwire systems using the Faraday effect. As an example, for 2-wire or 3-wire (1 ground wire) electrical systems, light is transmitted along an optical path which is exposed to magnetic fields produced by currents flowing in the hot and neutral wires. The rotations produced by these two magnetic fields cancel each other, therefore light on the optical path does not read the effect of either. However, when a ground fault occurs, the optical path is exposed to a net Faraday effect rotation due to the current imbalance thereby exposing the ground fault.

Patterson, Richard L.↗

The nature and origins of decametre-scale porosity in Ordovician carbonate rocks, Halahatang oilfield, Tarim Basin, China

At >7 km depths in the Tarim Basin, hydrocarbon reservoirs in Ordovician rocks of the Yijianfang Formation contain large cavities ( c . 10 m or more), vugs, fractures and porous fault rocks. Although some Yijianfang Formation outcrops contain shallow (formed near surface) palaeokarst features, cores from the Halahatang oilfield lack penetrative palaeokarst evidence. Outcrop palaeokarst cavities and opening-mode fractures are mostly mineral filled but some show evidence of secondary dissolution and fault rocks are locally highly ( c . 30%) porous. Cores contain textural evidence of repeated formation of dissolution cavities and subsequent filling by cement. Calcite isotopic analyses indicate depths between c . 220 and 2000 m. Correlation of core and image logs shows abundant cement-filled vugs associated with decametre-scale fractured zones with open cavities that host hydrocarbons. A Sm–Nd isochron age of 400 ± 37 Ma for fracture-filling fluorite indicates that cavities in core formed and were partially cemented prior to the Carboniferous, predating Permian oil emplacement. Repeated creation and filling of vugs, timing constraints and the association of vugs with large cavities suggest dissolution related to fractures and faults. In the current high-strain-rate regime, corroborated by velocity gradient tensor analysis of global positioning system (GPS) data, rapid horizontal extension could promote connection of porous and/or solution-enlarged fault rock, fractures and cavities. Supplementary material: Stable isotopic analyses and the velocity gradient tensor and principal direction and magnitude calculation are available at https://doi.org/10.6084/m9.figshare.c.4946046 Thematic collection: This article is part of the The Geology of Fractured Reservoirs collection available at: https://www.lyellcollection.org/cc/the-geology-of-fractured-reservoirs

Geology↗

Research challenges and directions in HVAC fault prevalence

This study provides a review of the current state of knowledge, gaps, and potential value in research on the prevalence of faults in commercial buildings. Two separate efforts were made in this study: (1) we performed a literature review to determine the extent of currently available fault prevalence data for heating, ventilation, and air-conditioning (HVAC) systems, and (2) we conducted dozens of interviews with subject matter experts and stakeholders to determine the HVAC fault data that would be of greatest value. Through the literature review and interviews, we discovered unmet needs for empirical data on the prevalence of faults at the desired level of granularity, consistency, and scale; this lack of data leads us to recommend future work studying commercial buildings’ HVAC fault prevalence, with robust fault taxonomy and a variety of meaningful fault prevalence metrics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault Detection on Seismic Structural Images Using a Nested Residual U-Net

Automatic identification of faults on seismic structural images is a challenging yet crucial task in quantitative seismic interpretation. Human picking or attribute-based fault detection methods may misidentify faults on noisy, complex seismic images. In this work, we develop a new automatic fault detection method using a nested residual U-shaped convolutional neural network. Each of the encoders and decoders in this neural network is a residual U-Net, leading to a nested architecture. The final fault map results from the fusion of three fault maps with low, medium, and high fault resolutions. We demonstrate the excellent fault-detection capability of our nested neural network using a series of synthetic and field seismic images. We find that our approach produces clearer and more interpretable fault maps than the current state-of-the-art U-Net fault detection method, particularly on noisy seismic images. Our new automatic fault detection method can facilitate reliable quantitative seismic interpretation on field seismic images.

58 GEOSCIENCES↗

New features of the ECH control system on DIII-D and impact of power modulation on collector loading

In order to increase the reliability and improve the availability of electron cyclotron heating (ECH) and current drive during a plasma shot, an adaptive gyrotron command generator has been designed and implemented in all gyrotron systems on the DIII-D tokamak. This adaptive real-time generator is able to detect imminent faults, including gyrotron body overcurrent faults that can develop in a few microseconds, block faults, and restart RF generation within 10–30 ms, faster than the DIII-D energy confinement time. The adoption of this adaptive generator has substantially improved the performance of a depressed-collector gyrotron with recurrent body current faults, and has assisted the ECH system to achieve a record reliability of 95% during the last experimental campaign. The impact of power modulation on the collector loading of a depressed-collector gyrotron has been experimentally studied using calorimetry and collector maps taken by a diagnostic developed in-house. While lowering the modulation duty cycle kept the collector power constant as a result of low beam-wave efficiency during the modulation low state, an observed power redistribution inside the collector increased the peak collector power density, which reached levels above the manufacturer power density limit for low duty cycles.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Small-Signal Stability of Grid-Forming Converters Under Fault Conditions

Threshold virtual impedance (TVI)-based current limiting for grid-forming converters (GFMs) has gained great interest due to its ability to maintain voltage source behaviour during faults. However, sequence component extraction (SCE) and negative-sequence control (NSC) are often overlooked in small-signal stability assessments during faults. This paper develops small-signal sequence impedance models for GFMs under four well-known SCE methods based on TVI current limiting control during symmetrical fault conditions. Using the developed impedance models, the impacts of SCE and NSC, and the voltage and current control loop bandwidths, on system stability during faults are investigated. Additionally, since negative-sequence TVI (TVI-) is typically added along with its positive-sequence counterpart, which is often inductive, inductive and resistive TVI- are examined. The findings suggest that a higher voltage or current control loop bandwidth has a negative impact on system stability, while SCE and NSC largely reduce the stable range for voltage and current control loop bandwidth during faults, and that the severity of such impacts is determined by the particular SCE method. Furthermore, it is observed that inductive TVI- significantly degrades system stability, while resistive TVI- can enhance stability when suitable SCE methods are appropriately selected and designed. Matlab/Simulink electromagnetic transient simulations validate these analytical results.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Grid Forming Control of PMSG-based Wind Turbines under Fault Conditions

Grid-forming control is widely envisioned as core technology ensuring stable operation of future power systems with increasing deployment of converter-interfaced renewable generation. However, research on grid forming control of wind turbines, especially under faults, is still in its early stages. In this context, this paper augments dual-port grid-forming control for type IV wind turbines with auxiliary controls to enable reliable fault ride through capabilities. In particular, the proposed control does not require a dc chopper or mode switching to grid-following control. Instead, energy-balancing dual-port GFM control is augmented with active rotor speed damping control and threshold virtual impedance for current limiting during faults. Different operating conditions of wind turbines are considered in a detailed electromagnetic transient simulation study to validate the effectiveness of the proposed control.

Lyu, Xue↗

Dynamic test input generation for multiple-fault isolation

Recent work is Causal Reasoning has provided practical techniques for multiple fault diagnosis. These techniques provide a hypothesis/measurement diagnosis cycle. Using probabilistic methods, they choose the best measurements to make, then update fault hypotheses in response. For many applications such as computers and spacecraft, few measurement points may be accessible, or values may change quickly as the system under diagnosis operates. In these cases, a hypothesis/measurement cycle is insufficient. A technique is presented for a hypothesis/test-input/measurement diagnosis cycle. In contrast to generating tests a priori for determining device functionality, it dynamically generates tests in response to current knowledge about fault probabilities. It is shown how the mathematics previously used for measurement specification can be applied to the test input generation process. An example from an efficient implementation called Multi-Purpose Causal (MPC) is presented.

Schaefer, Phil↗

Systems and methods for global cyber-attack or fault detection model

An industrial asset may have monitoring nodes that generate current monitoring node values representing a current operation of the industrial asset. An abnormality detection computer may detect when a monitoring node is currently being attacked or experiencing a fault based on a current feature vector, calculated in accordance with current monitoring node values, and a detection model that includes a decision boundary. A model updater (e.g., a continuous learning model updater) may determine an update time-frame (e.g., short-term, mid-term, long-term, etc.) associated with the system based on trigger occurrence detection (e.g., associated with a time-based trigger, a performance-based trigger, an event-based trigger, etc.). The model updater may then update the detection model in accordance with the determined update time-frame (and, in some embodiments, continuous learning).

Xu, Rui↗

Mini-Ckpts: Surviving OS Failures in Persistent Memory

Concern is growing in the high-performance computing (HPC) community on the reliability of future extreme-scale systems. Current efforts have focused on application fault-tolerance rather than the operating system (OS), despite the fact that recent studies have suggested that failures in OS memory are more likely. The OS is critical to a system's correct and efficient operation of the node and processes it governs -- and in HPC also for any other nodes a parallelized application runs on and communicates with: Any single node failure generally forces all processes of this application to terminate due to tight communication in HPC. Therefore, the OS itself must be capable of tolerating failures. In this work, we introduce mini-ckpts, a framework which enables application survival despite the occurrence of a fatal OS failure or crash. Mini-ckpts achieves this tolerance by ensuring that the critical data describing a process is preserved in persistent memory prior to the failure. Following the failure, the OS is rejuvenated via a warm reboot and the application continues execution effectively making the failure and restart transparent. The mini-ckpts rejuvenation and recovery process is measured to take between three to six seconds and has a failure-free overhead of between 3-5% for a number of key HPC workloads. In contrast to current fault-tolerance methods, this work ensures that the operating and runtime system can continue in the presence of faults. This is a much finer-grained and dynamic method of fault-tolerance than the current, coarse-grained, application-centric methods. Handling faults at this level has the potential to greatly reduce overheads and enables mitigation of additional fault scenarios.

Fiala, David↗

Flexible $I_{Q}\!\!-\!\!V$ Scheme of a DFIG for Rapid Voltage Regulation of a Wind Power Plant

This paper proposes a flexible reactive current-to-voltage (I Q -V) scheme of a doubly-fed induction generator (DFIG) for the rapid voltage regulation of a wind power plant (WPP). In the proposed scheme, the WPP controller dispatches different voltage set points to the DFIGs depending on their rotor voltage margins. The DFIGs inject different reactive power with the flexible I Q -V schemes implemented in the rotor-side and grid-side converters. The I Q -V characteristic, which consists of the gain and width of a linear band and I Q capability, varies with time depending on the I Q capability of the converters and a voltage dip at the point of interconnection (POI). To increase the I Q capability during a fault, the active current is reduced in proportion to a voltage dip. If the I Q capability and/or the POI voltage dip are large, the I Q -V gain is set to be high, thereby providing rapid voltage regulation. To avoid an overvoltage after the fault clearance, a rapid I Q reduction scheme is implemented in the WPP and DFIG controllers. The performance of the proposed flexible scheme was verified under scenarios with various disturbances. In conclusion, the proposed scheme can help increase wind power penetration without jeopardizing voltage stability.

17 WIND ENERGY↗

Creating dynamic equivalent PV circuit models with impedance spectroscopy for arc-fault modeling.

Article 690.11 in the 2011 National Electrical Code{reg_sign} (NEC{reg_sign}) requires new photovoltaic (PV) systems on or penetrating a building to include a listed arc fault protection device. Currently there is little experimental or empirical research into the behavior of the arcing frequencies through PV components despite the potential for modules and other PV components to filter or attenuate arcing signatures that could render the arc detector ineffective. To model AC arcing signal propagation along PV strings, the well-studied DC diode models were found to inadequately capture the behavior of high frequency arcing signals. Instead dynamic equivalent circuit models of PV modules were required to describe the impedance for alternating currents in modules. The nonlinearities present in PV cells resulting from irradiance, temperature, frequency, and bias voltage variations make modeling these systems challenging. Linearized dynamic equivalent circuits were created for multiple PV module manufacturers and module technologies. The equivalent resistances and capacitances for the modules were determined using impedance spectroscopy with no bias voltage and no irradiance. The equivalent circuit model was employed to evaluate modules having irradiance conditions that could not be measured directly with the instrumentation. Although there was a wide range of circuit component values, the complex impedance model does not predict filtering of arc fault frequencies in PV strings for any irradiance level. Experimental results with no irradiance agree with the model and show nearly no attenuation for 1 Hz to 100 kHz input frequencies.

99 GENERAL AND MISCELLANEOUS↗

Behavior of Single-Line-Ground Faults in Inverter-Based Resource Dominated Grids Explained

It has been observed by protection engineers that it is difficult for a protective relay to identify the faulted phase during a single-line-ground (SLG) fault in a power system with a high ingression of inverter-based resources (IBR) using currents (phase or sequence). Further studies using electromagnetic transient (EMT) simulation show that the initial operating conditions of the IBRs influence the response of phase currents during an SLG fault. In this letter, we conduct a quantitative analysis using sequence components. We find that the pre-fault condition determines the relative position of the current contributed by the grid versus that from the IBR, and further dictates which phase has the largest magnitude during an SLG condition. Finally, this finding is further verified by the EMT simulation results.

electromagnetic transient simulation↗

Searching for Grid-Forming Technologies That Do Not Impact Protection Systems: A promising technology

The design of legacy-line protection elements has been guided by the behavior of synchronous machines during faults. Because of the significant field-winding inductance and rotating mass, the magnitude, angular frequency, and phase angle of the back-electromotive force (EMF) voltage waveforms of synchronous machines remain practically constant for several hundreds of milliseconds after a fault occurs. Furthermore this has facilitated the engineering of the memory-polarization technique in mho distance elements, which has been effective for machine-dominant power grids. However, this assumption is no longer held for inverter-based resources (IBRs) because of the lack of field winding and moment of inertia in power electronics devices. Notably, the negative-sequence directional overcurrent protection and the quadrilateral distance elements have been impacted by early IBRs with grid-following (GFL) controls because they did not inject negative-sequence currents during asymmetrical faults.