Search NASASearch

SEARCH · Search NASA

Results for “filaments observation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

282 records · Page 16

Fast Growth of Ga2O3 on Highly Offcut (100)-Oriented Substrates

Beta-Ga2O3 has emerged as a leading candidate for next-generation power electronics, radio frequency (RF) switches, and extreme environment electronics due to a wide band gap (4.6 - 4.9 eV), high dopability (approximately 40 meV activation energy for an isolated silicon donor), and melt growth characteristics resulting in commercially available 4-inch substrates and commercial demonstrations of 6-inch substrates by multiple techniques. The (100) surface of Ga2O3 is highly desirable from a device and epitaxy standpoint - bulk growth of (100) material is more scalable than (010), the surface is nearly lattice-matched to p-type partner NiO, and Al2O3 incorporates at higher concentrations without phase separation. More importantly, the impact ionization coefficients along the [100] direction are low, leading to the highest possible critical fields. This is advantageous compared to the current state of the art, (001), due to reduced surface defects and increased possible breakdown voltage. However, the epitaxial growth rate on (100) surfaces is less than 10% of other faces due to weak bonding and favorable desorption, and on-axis (100) growth easily forms twin domains. Recent demonstrations have shown growth rate improvements from 0.4 nm/min to 1.5 nm/min by growing on (100) wafers that are offcut 6 degrees in the -c direction. These films show step-flow growth from (20-1) step-edges and high electron mobility due to suppressed twins. Despite these exciting results, offcuts greater than 6 degrees have not been explored due to the waste associated with grinding and polishing large offcuts. In this talk we will discuss the molecular beam epitaxy (MBE) growth and properties of Beta-Ga2O3 grown on (100) substrates offcut in the -c direction up to 13.4 degrees. These large offcuts are enabled by edge-fed film-defined growth (EFG) where the offcut is grown into the surface by pulling the crystal through the EFG die with the seed crystal rotated by the desired offcut angle. We will demonstrate that 13.4 degrees offcut substrates still exhibit a terraced (100) surface, and that a >10x increase (>5 nm/min) in growth rate is achieved. As previously reported on lower offcuts, we observe reversal of substrate twin domains around the (001) direction at the substrate-epilayer interface. We will discuss electrical properties including record-low (by MBE) unintentional doping densities of < 5E15 cm-3 and critical breakdown field in Schottky barrier diodes comparable with state-of-the-art (001) Ga2O3 without edge termination.

36 MATERIALS SCIENCE

Shakeup and shakeoff spectra in the electron capture decay of atomic 7 Be

The most stringent laboratory-based experimental limits on the existence of submegaelectronvolt sterile neutrinos are currently set by decay spectroscopy of radioactive 7 Be embedded into superconducting sensors. The systematic uncertainties are dominated by the modeling of the electron shakeup and shakeoff spectra that are not based on state-of-the-art atomic theory and do not include electron correlations or relativistic effects. We have used the multiconfiguration Dirac-Fock formalism to obtain correlated wave functions ab initio and compute all single and double shake processes in the electron capture decay of atomic 7 Be . The simulations can explain some but not all of the observed spectral features, likely because the wave functions are modified by the Ta sensor material that the 7 Be is embedded into. The new models also show that the 𝐿/𝐾 electron capture ratio of 7 Be in Ta has previously been slightly underestimated revising the previous value of 0.070(7) to a new value of 0.0756(20).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Anomalous Spin‐Optical Helical Effect in Ti‐Based Kagome Metal

The kagome lattice stands as a rich platform for hosting a wide array of correlated quantum phenomena, ranging from charge density waves and superconductivity to electron nematicity and loop current states. Direct detection of loop currents in kagome systems has remained a formidable challenge due to their intricate spatial arrangements and the weak magnetic field signatures they produce, and this has made their identification experimentally subtle. This has left their existence and underlying mechanisms a topic of intense debate. In this work, we uncover signatures compatible with loop currents: spin handedness-selective signals that surpass conventional dichroic, spin, and spin-dichroic responses. We observe this phenomenon in the kagome metal CsTi 3 ⁢Bi 5 and we call it the anomalous spin-optical helical effect. This effect arises from the coupling of light's helicity with spin-orbital electron correlations, thereby providing an indirect yet sensitive approach to probe loop-current–related electronic correlations in quantum materials. Our discovery not only enriches the debate surrounding loop currents but also offers new experimental strategies to exploit the electronic phases of quantum materials via light–matter interaction.

anomalous spin-optical helical effect

Study of Key 57 Ni ⁢(𝑝,𝛾)⁢ 58 Cu Resonances to Understand 44 Ti Nucleosynthesis in Supernovae

An important validation of nucleosynthesis models of core-collapse supernovae is the comparison of radioisotope predictions to abundances inferred from observations of 𝛾 rays emitted in remnants. One such isotope, 44 Ti, is especially sensitive to the 57 Ni ⁢(𝑝,𝛾)⁢ 58 Cu reaction rate. Despite this importance, no experimentally constrained rate exists for this reaction. It is thus crucial to determine this rate. GRETINA ORRUBA: Dual Detectors for Experimental Structure Studies (GODDESS) was used along with the first use of the Enge split-pole spectrograph at Notre Dame to measure structure properties of 58 Cu via the 58 Ni ⁢( 3 He,𝑡)⁢ 58 Cu reaction. Here, the combined analysis of these complementary data sets allows for precise determination of 58 Cu level energies, and spins are constrained from analysis of the 𝛾-ray decay. 44 Ti yields were found to change by over 25% compared to previous estimates in model calculations using the new experimentally constrained reaction rate.

energy levels

Purcell enhancement of directional edge photocurrent in a van der Waals self-cavity

Cavities provide a means to manipulate the optical and electronic responses of quantum materials by selectively enhancing light-matter interaction at specific frequencies and momenta. While cavities typically involve external structures, exfoliated flakes of van der Waals (vdW) materials can form intrinsic self-cavities due to their small finite dimensions, confining electromagnetic fields into plasmonic cavity modes, characterized by standing-wave current distributions. While cavity-enhanced phenomena are well-studied at optical frequencies, the impact of self-cavities on nonlinear electronic responses—such as directional photocurrent—remains largely unexplored, particularly in the terahertz regime, critical for emerging ultrafast optoelectronic technologies. Here, we report a self-cavity-induced Purcell enhancement of directional photocurrents in the vdW semimetal WTe 2 . Using ultrafast optoelectronic circuitry, we measured coherent near-field THz emission resulting from nonlinear photocurrents excited at the sample edges. We observed enhanced emission at finite frequencies, tunable via excitation fluence and sample geometry, which we attribute to plasmonic interference effects controlled by the cavity boundaries. We developed an analytical theory that captures the cavity resonance conditions and spectral response across multiple devices. Our findings establish WTe 2 as a bias-free, geometry-tunable THz emitter and demonstrate the potential of self-cavity engineering for controlling nonlinear, nonequilibrium dynamics in quantum materials.

condensed-matter physics

Assembly bias and local Primordial non-Gaussianity from DESI DR1 quasars

The analysis of the large-scale clustering of quasars (QSO) observed by the Dark Energy Spectroscopic Instrument (DESI) represents a promising avenue for constraining local Primordial non-Gaussianity (PNG), parameterized by f NL . The signal to be constrained is the scale-dependent bias induced in the 2-point clustering of the considered tracer sample. The resulting constraints on f NL , however, are fully degenerate with the local PNG bias parameter b ϕ , dependent on the assembly bias parameter p. Using IllustrisTNG hydrodynamical simulations, we select a QSO sample reflecting the selection criteria and properties of DESI QSOs, and provide a robust prior for p, and thus for b ϕ , building on the findings of Fondi et al. 2024. We find a distribution with mean p̅ ≃ 1.4 with weak redshift dependence, stable to selection noise and consistent with the expected recent merger history typical of quasar-hosting halos. By comparing with the CAMELS simulations we demonstrate that this prior is robust to astrophysical assumptions and cosmic variance. Finally, applying this prior to the DESI DR1 dataset, we derive updated constraints on local PNG, obtaining f NL = -3.3±9.2.

cosmological parameters from LSS

Single-Nucleon Transfer on Unstable 59 Cu Probes the NiCu Cycle in Astrophysical X-Ray Bursts

Recent models of the rapid proton (𝑟⁢𝑝) capture process indicate that a competition between the 59 Cu⁢(𝑝,𝛾) ⁢60 Zn and 59 Cu⁢(𝑝,𝛼) ⁢56 Ni reactions may result in the formation of a nickel-copper (NiCu) cycle that traps the flux of material between 56 Ni and 60 Zn . Here, in this work, we report the identification of 15 proton-unbound levels in 60 Zn , populated via 59 Cu⁢(𝑑,𝑛) transfer, which govern the rate of the 59 Cu⁢(𝑝,𝛾)⁢ 60 Zn reaction in XRBs. Precise excitation energies for levels in 60 Zn were obtained from observed 𝛾 decays, and spectroscopic factors were determined from angle-integrated cross sections. Incorporating these results into stellar-model calculations, we find that with experimentally constrained uncertainties a NiCu cycle in XRBs is indeed possible, though we limit its branching strength to less than 38%. While modest, such a branching has significant impact on the light curve, motivating further studies of the relevant rates. Our calculations also indicate that a significant NiCu cycle leads to an increase in the amount of odd-𝐴 nuclei in the burst ashes, which may affect Urca cooling processes in neutron star crusts.

direct reactions

Search for New Physics via Low-Energy Electron Recoils with a 4.2 Tonne-Year Exposure from the LZ Experiment

We report results from searches for new physics models through electron recoils using data collected by the LUX-ZEPLIN experiment during its first two science runs, with a total exposure of 4.2 tonne−years. The observed data are consistent with a background-only hypothesis. Constraints are derived for electromagnetic interactions of solar neutrinos, solar axionlike particles (ALPs), mirror dark matter, and the absorption of bosonic dark matter candidates. The inverse Primakoff process for 57 Fe deexcitation solar ALPs is considered for the first time. These results represent the most stringent constraints to date on keV-scale Primakoff and 57 Fe solar ALPs, bosonic dark matter, mirror dark matter, and neutrino millicharge, while remaining competitive for the other signal models investigated.

Axion-like particles

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science

SPT clusters with DES and HST weak lensing. II. Cosmological constraints from the abundance of massive halos

We present cosmological constraints from the abundance of galaxy clusters selected via the thermal Sunyaev-Zel’dovich (SZ) effect in South Pole Telescope (SPT) data with a simultaneous mass calibration using weak gravitational lensing data from the Dark Energy Survey (DES) and the Hubble Space Telescope (HST). The cluster sample is constructed from the combined SPT-SZ, SPTpol ECS, and SPTpol 500d surveys, and comprises 1,005 confirmed clusters in the redshift range 0.25–1.78 over a total sky area of 5200 deg 2 . We use DES Year 3 weak-lensing data for 688 clusters with redshifts 𝑧 < 0.95 and HST weak-lensing data for 39 clusters with 0.6 < 𝑧 < 1.7. The weak-lensing measurements enable robust mass measurements of sample clusters and allow us to empirically constrain the SZ observable-mass relation without having to make strong assumptions about, e.g., the hydrodynamical state of the clusters. For a flat Λ⁢ CDM cosmology, and marginalizing over the sum of massive neutrinos, we measure Ω m = 0.286 ± 0.032, 𝜎 8 = 0.817 ± 0.026, and the parameter combination 𝜎 8 ⁢(Ω m /0.3) 0.25 = 0.805 ± 0.016. Our measurement of 𝑆 8 ≡ 𝜎 8 ⁢$\sqrt{Ω_{m}/0.3}$ = 0.795 ± 0.029 and the constraint from Planck CMB anisotropies (2018 TT, TE, EE+lowE) differ by 1.1⁢𝜎. In combination with that Planck dataset, we place a 95% upper limit on the sum of neutrino masses ∑𝑚 𝜈 < 0.18 eV. When additionally allowing the dark energy equation of state parameter 𝑤 to vary, we obtain 𝑤 = −1.45 ± 0.31 from our cluster-based analysis. In combination with Planck data, we measure 𝑤 =−1.3⁢4$^{+0.22}_{−0.15}$, or a 2.2⁢𝜎 difference with a cosmological constant. We use the cluster abundance to measure 𝜎8 in five redshift bins between 0.25 and 1.8, and we find the results to be consistent with structure growth as predicted by the Λ⁢ CDM model fit to Planck primary CMB data.

79 ASTRONOMY AND ASTROPHYSICS

The Dark Energy Survey supernova program: a reanalysis of cosmology results and evidence for evolving dark energy with an updated Type Ia supernova calibration

We present improved cosmological constraints from a re-analysis of the Dark Energy Survey (DES) 5-year sample of Type Ia supernovae (DES-SN5YR). This re-analysis includes an improved photometric cross-calibration, recent white dwarf observations to cross-calibrate between DES and low-redshift surveys, retraining the salt3 light-curve model and fixing a numerical approximation in the host-galaxy colour law. Our fully recalibrated sample, which we call DES-Dovekie, comprises ~1600 likely Type Ia SNe from DES and ~200 low-redshift SNe from other surveys. With DES-Dovekie, we obtain Ω m = 0.330 ± 0.015 in flat Lambda-cold dark matter (⁠ΛCDM) which changes Ω m by –0.022 compared to DES-SN5YR. Combining DES-Dovekie with cosmic microwave background data from Planck, Atacama Cosmology Telescope, and South Pole Telescope and the DESI DR2 measurements in a flat CDM cosmology, we find ω 0 = –0.803 ± 0.054 and ω a = –0.72 ± 0.21⁠. Our results hold a significance of 3.2σ, reduced from 4.2σ for DES-SN5YR, to reject the null hypothesis that the data are compatible with the cosmological constant. This significance is equivalent to a Bayesian model preference odds of approximately 5:1 in favour of the flat ω 0 ω a CDM model. Using generally accepted thresholds for model preference, our updated data exhibits only a weak preference for evolving dark energy.

dark energy

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI