Search NASA⌕ Search

SEARCH · Search NASA

Results for “flexure”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Prediction of properties of intraply hybrid composites

Equations based on the mixtures rule are presented for predicting the physical, thermal, hygral, and mechanical properties of unidirectional intraply hybrid composites (UIHC) from the corresponding properties of their constituent composites. Bounds were derived for uniaxial longitudinal strengths, tension, compression, and flexure of UIHC. The equations predict shear and flexural properties which agree with experimental data from UIHC. Use of these equations in a composites mechanics computer code predicted flexural moduli which agree with experimental data from various intraply hybrid angleplied laminates (IHAL). It is indicated, briefly, how these equations can be used in conjunction with composite mechanics and structural analysis during the analysis/design process.

Chamis, C. C.↗

Ultra-high modulus organic fiber hybrid composites

An experimental organic fiber, designated Fiber D, was characterized, and its performance as a reinforcement for composites was investigated. The fiber has a modulus of 172 GPa, tensile strength of 3.14 GPa, and density of 1.46 gm/cu cm. Unidirectional Fiber D/epoxy laminates containing 60 percent fiber by volume were evaluated in flexure, shear, and compression, at room temperature and 121 C in both the as fabricated condition and after humidity aging for 14 days at 95 percent RH and 82 C. A modulus of 94.1 GPa, flexure strength of 700 MPa, shear strength of 54 MPa, and compressive strength of 232 MPa were observed at room temperature. The as-fabricated composites at elevated temperature and humidity aged material at room temperature had properties 1 to 20 percent below these values. Combined humidity aging plus evaluated temperature testing resulted in even lower mechanical properties. Hybrid composite laminates of Fiber D with Fiber FP alumina or Thornel 300 graphite fiber were also evaluated and significant increases in modulus, flexure, and compressive strengths were observed.

Champion, A. R.↗

Vibration damping characteristics of graphite/epoxy composites for large space structures

Limited data on extensional and flexural damping of small specimens of graphite/epoxy and unreinforced epoxy resin were obtained. Flexural damping was measured using a forced vibration technique based on resonant flexural vibration of shaker excited double cantilever specimens. Extensional damping was measured by subjecting similar specimens to low frequency sinusoidal oscillation in a servohydraulic tensile testing machine while plotting load versus extensional strain. Damping was found to vary slowly and continuously over the frequency range 0.01 - 1000 Hz, and no drastic transitions were observed. Composite damping was found to be less than neat resin damping. Comparison of small specimen damping values with assembled column damping values seems to indicate that, for those materials, material damping is more important than joint damping. The data reported was limited not by the test apparatus, but by signal conditioning and data acquisition. It is believed that filtering of the strain gage signals and the use of digital storage with slow playback will make it possible to extend the frequency and amplitude ranges significantly.

Gibson, R. F.↗

Compression behavior of unidirectional fibrous composite

The longitudinal compression behavior of unidirectional fiber composites is investigated using a modified Celanese test method with thick and thin test specimens. The test data obtained are interpreted using the stress/strain curves from back-to-back strain gages, examination of fracture surfaces by scanning electron microscope, and predictive equations for distinct failure modes including fiber compression failure, Euler buckling, delamination, and flexure. The results show that the longitudinal compression fracture is induced by a combination of delamination, flexure, and fiber tier breaks. No distinct fracture surface characteristics can be associated with unique failure modes. An equation is described which can be used to extract the longitudinal compression strength knowing the longitudinal tensile and flexural strengths of the same composite system.

Sinclair, J. H.↗

Pressure suit joint analyzer

A measurement system for simultaneously measuring torque and angular flexure in a pressure suit joint is described. One end of a joint under test is held rigid. A torque transducer is pivotably supported on the other movable end of a joint. A potentiometer is attached to the transducer by an arm. The wiper shaft of the potentiometer is gripped by a reference arm that rotates the wiper shaft the same angle as the flexure of joint. A signal is generated by the potentiometer which is representative of the joint flexure. A compensation circuit converts the output of the transducer to a signal representative of joint torque.

Vykukal, H. C.↗

The negative gravity field over the 85 deg E ridge

Two north-south ridges in the basement topography of the Bay of Bengal may be observed on an isopach map at 85 and at 90 deg E. Free-air gravity anomaly profiles across the region show a strong gravity low (about -60 mGal) over the 85 deg E ridge, and a gravity high over the other. Using a simple two-stage loading model, the negative gravity anomaly over the 85 deg E ridge is explained as a direct consequence of sediment loading, and the flexural rigidity of the lithosphere when the ridge was formed is estimated to have been about 180 times less than the flexural rigidity during the sediment loading. An approximate relationship between flexural rigidity and crustal age shows that the 85 deg E ridge was formed on relatively young lithosphere, 5-15 million years old, and that it was buried when the lithosphere was 40-80 million years old. The alteration of the gravity field by a thick layer of sediments may occur in other large sedimentary basins or along continental margins.

Liu, C.-S.↗

Bathymetric prediction from Seasat altimeter data

The linear response function technique is used to analyze two 1300 km tracks of Seasat altimeter data and corresponding bathymetry in the Musician Seamounts region north of Hawaii. A predictive filter is developed which can operate on Seasat altimetry in poorly surveyed oceanic regions to indicate the presence of major bathymetric anomalies. Modelling of the bathymetry-geoid correlation in the Musician region is attempted using the elastic plate model. The flexural rigidity of the plate is not well constrained by the data but appears to be in the range 5 x 10 to the 21st N m up to 5 x 10 to the 22nd N m at the time of loading. Since the Musician Seamounts and the crust on which they lie are both Late Cretaceous in age, this value represents the effective flexural rigidity of very young lithosphere that was 'frozen in' at the time of volcanism. The modelling indicates that the general form of a predictive filter will strongly depend on various geologic parameters, especially the effective flexural rigidity.

Dixon, T. H.↗

Thermal aging of graphite/polyimide composites

Celion 6000/PMR-15, Celion 6000/LARC-160, and Celion 6000/RK-99 graphite/polyimides were aged in circulating air ovens at temperatures of 202, 232, 260, and 288 C for various times, up to 15,000 h. Three unidirectional specimens were studied: short-beam-shear (SBS), flexure, and 153-mm square panels. The interior region of the square panels exhibited little or no property degradation. Based on the individually aged SBS specimen results, the relative thermal-oxidative stability from highest to lowest is as follows: PMR-15, LARC-160, RK-99, Celion 6000/PMR-15 and Celion 6000/LARC-160 laminates retained at least 80 percent of their initial flexural strengths for the duration of aging at each temperature. Celion 6000/RK-99 laminates exhibited a 20 to 50 percent loss of flexural strength at all aging temperatures. All three graphite/polyimide laminate materials degraded preferentially at the specimen edge perpendicular to the fibers.

Nelson, J. B.↗

Compressive behavior of unidirectional fibrous composites

The longitudinal compressive behavior of unidirectional fiber composites was investigated by using the Illinois Institute of Technology Research Institute (IITRI) test method with thick and thin test specimens. The test data obtained are interpreted by means of stress/strain curves from back-to-back strain gages, examination of fracture surfaces by scanning electron microscope, and predictive equations for distinct failure modes including fiber compression failure. Euler buckling, delamination, and flexure. The results show that longitudinal compressive fracture is induced by a combination of delamination, flexure, and fiber tier breaks. No distinct fracture surface characteristics can be associated with unique failure modes. An equation is described that can be used to extract the longitudinal compressive strength from the longitudinal tensile and flexural strengths of the same composite system.

Sinclair, J. H.↗

Turbine blade friction damping study

A lumped parameter method, implemented on a VAX 11/780 computer shows that the primary parameters affecting the performance of the friction damper of the first stage turbine of the SSME high pressure fuel pump are: the damper-blade coefficient of friction; the normal force applied to the friction interface; the amplitude of the periodic forcing function; the relative phase angle of the forcing functions for adjacent blades bridged by a damper (effectively, the engine order of the forcing function); and the amount of hysteretic damping that acts to limit the vibration amplitude of the blade in its resonance modes. The low order flexural resonance vibration modes of HPFTP blades without dampers, with production dampers, and with two types of lightweight experimental dampers were evaluated in high speed spin pit tests. Results agree with those of the analytical study in that blades fitted with production friction dampers experienced the airfoil-alone flexural resonance mode, while those without dampers or with lighter weight dampers did not. No blades fitted with dampers experienced the whole blade flexural resonance mode during high speed tests, while those without dampers did.

Dominic, R. J.↗

Mars - Thickness of the lithosphere from the tectonic response to volcanic loads

The response to loading of the elastic lithosphere of Mars by seven large volcanic features is estimated based on the hypothesis of a flexural origin for a definable set of load-concentric graben. From the locations of such graben, or from their absence, the lithospheric thickness and flexural rigidity are inferred. For the Tharsis montes, Alba Patera, and Elysium Mons, elastic lithospheric thicknesses at the time of loading range from 20 to 50 km, assuming a Young's modulus of a trillion dyn/sq cm. The thickness exceeded 120 km beneath Olympus Mons and Isidis Planitia. The corresponding ranges in flexural rigidity are approximately 10 to the 30th to 31st dyn cm and greater than 10 to the 32nd dyn cm, respectively. These results indicate a local thinning of the lithosphere beneath portions of the central regions of the Tharsis and Elysium volcanic provinces at the time of loading-induced fracturing.

Comer, R. P.↗

Strength and microstructure of Si3N4 sintered with ZrO2 additions

Densities greater than 99 percent of theoretical were obtained with stabilized ZrO2 additions to Si3N4. Material sintered at 2140 C under 2.5 MPa nitrogen overpressure with 3.8, 9.9, and 13.4 wt pct ZrO2 had a predominantaly equiaxed grain size ranging from 0.2 to 7.0 microns. At 1370 C, the latter composition exhibited a flexural strength of about 487 MPa, equal to that of a finer-grain-size, hot-pressed Si3N4 + ZrO2 material having excellent high-temperature static fatigue properties. Transmission electron microscopy of the sintered Si3N4 revealed a glassy grain-boundary phase at all three ZrO2 levels and partially crystalline triple points for the 9.9 and 13.4 wt pct ZrO2-containing materials. Slow crack growth was observed for 1370 C flexure tests and correlated with nonlinear load deflection traces for stresses greater than 503 MPa. The crystallization of the grain-boundary glass is insterpreted as beneficial to the attainment of high (1370 C) flexural strength.

Sanders, W. A.↗

Transitioning of power flow in beam models with bends

The propagation of power flow through a dynamically loaded beam model with 90 degree bends is investigated using NASTRAN and McPOW. The transitioning of power flow types (axial, torsional, and flexural) is observed throughout the structure. To get accurate calculations of the torsional response of beams using NASTRAN, torsional inertia effects had to be added to the mass matrix calculation section of the program. Also, mass effects were included in the calculation of BAR forces to improve the continuity of power flow between elements. The importance of including all types of power flow in an analysis, rather than only flexural power, is indicated by the example. Trying to interpret power flow results that only consider flexural components in even a moderately complex problem will result in incorrect conclusions concerning the total power flow field.

Hambric, Stephen A.↗

Mechanical strain isolator mount

Certain devices such as optical instruments must preserve their alignmental integrity while being subjected to mechanical strain. A mechanical strain isolator mount is provided to preserve the alignmental integrity of an alignment sensitive instrument. An alignment sensitive instrument is mounted on a rectangular base. Flexural legs are connected at their proximal ends to the rectangular base. Flexural legs are also spaced parallel to the sides. Mounting pads are connected to the legs at the distal end and the mechanical strain isolator mount is attached to the substrate by means of threaded bolts. When a mounting pad and its respective leg is subjected to lateral strain in either the X or Y direction via the substrate, the respective leg relieves the strain by bending in the direction of the strain. An axial strain on a mounting pad in the Z direction is relieved by a rotational motion of the legs in the direction of the strain. When the substrate is stress free, the flexural legs return to their original condition and thus preserve the original alignment integrity of the alignment sensitive instrument.

James, Gordon E.↗

Flexible thermal apparatus for mounting of thermoelectric cooler

A flexible heat transfer apparatus used to flexibly connect and thermally couple a thermoelectric cooler to an object to be cooled is disclosed. The flexible heat transfer apparatus consists of a pair of flexible corrugated sheets made from high thermal conductivity materials such as copper, aluminum, gold, or silver. The ridges of the corrugated sheets are oriented perpendicular to one another and bonded sandwich-fashion between three plates to define an upper section and a lower section. The upper section provides X flexure, the lower section provides Y flexure, and both sections together provide Z flexure.

Jones, Jack A.↗

Interpretation of the northern boundary of Ishtar Terra from Magellan images and altimetry

Part of the controversy on the origin of western Ishtar Terra (IT) concerns the nature of Uorsar Rupes (UR), the northern boundary of IT. In the hypothesis of lithospheric convergence and underthrusting, UR is held to be the main boundary thrust fault at the toe of an accretionary wedge. A topographic rise parallel to the scarp was interpreted as a flexural bulge similar to those of terrestrial subduction zones, and quantitative models of this feature seemed broadly consistent with the expected lithospheric structure of Venus. In the alternative mantle upwelling hypothesis for western IT, the outer margins of the highland are thought to be collapsing, and UR has been interpreted as a normal fault. Herein, Magellan images and altimetry are interpreted for this region and the hypothesis that a flexural signature can be distinguished is reassessed. The Magellan images of IT show evidence of crustal shortening adjacent to UR, but extension and burial dominate northwards. Altimetric profiles display the same long wavelength trends visible in Venera data, but no clear evidence of the lithospheric flexure. A model of regional extension and burial is herein favored, but regional compression cannot be ruled out.

Mueller, S.↗

Construction, wind tunnel testing and data analysis for a 1/5 scale ultra-light wing model

This report documents the construction, wind tunnel testing, and data analysis of a 1/5 scale ultra-light wing section. Wind tunnel testing provided accurate and meaningful lift, drag, and pitching moment data. This data was processed and graphically presented as follows: C(sub L) vs. gamma; C(sub D) vs. gamma; C(sub M) vs. gamma; and C(sub L) vs. C(sub D). The wing fabric flexure was found to be significant and its possible effects on aerodynamic data was discussed. The fabric flexure is directly related to wing angle of attack and airspeed. Different wing section shapes created by fabric flexure are presented with explanations of the types of pressures that act upon the wing surface. This report provides conclusive aerodynamic data for ultra-light wings.

James, Michael D.↗

Damage and failure mechanisms of continuous glass fiber reinforced polyphenylene sulfide

The damage that accompanies flexural deformation of a unidirectional glass fiber composite of polyphenylene sulfide was examined by AE and SEM. These complementary techniques were used to identify damage mechanisms at the microscale and correlate them with the macroscopic stress state in four-point bending. The flexural stress-strain curve was nominally linear to about 1.0 percent strain, but the onset of damage detectable by AE occurred at 0.3 percent strain. Two peaks in the AE amplitude distribution were observed at 35 dB and 60 dB. Low-amplitude events were detected along the entire length of the specimen, and correlation with direct observations of damage made by deforming the composite on the SEM stage suggested that these events arose from matrix cracking and fiber debonding concentrated at flaws on the composite. High amplitude events occurred primarily in the region of highest flexural stress between the inner loading points. They were attributed to fracture of glass fibers on the tension side and surface damage on the compressive side.

Chen, F.↗