Search NASA⌕ Search

SEARCH · Search NASA

Results for “fluorescent”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Fluorescence-coupled micropipette aspiration assay to examine calcium mobilization caused by red blood cell mechanosensing

Abstract Mechanical stimuli such as tension, compression, and shear stress play critical roles in the physiological functions of red blood cells (RBCs) and their homeostasis, ATP release, and rheological properties. Intracellular calcium (Ca 2+ ) mobilization reflects RBC mechanosensing as they transverse the complex vasculature. Emerging studies have demonstrated the presence of mechanosensitive Ca 2+ permeable ion channels and their function has been implicated in the regulation of RBC volume and deformability. However, how these mechanoreceptors trigger Ca 2+ influx and subsequent cellular responses are still unclear. Here, we introduce a fluorescence-coupled micropipette aspiration assay to examine RBC mechanosensing at the single-cell level. To achieve a wide range of cell aspirations, we implemented and compared two negative pressure adjusting apparatuses: a homemade water manometer (− 2.94 to 0 mmH 2 O) and a pneumatic high-speed pressure clamp (− 25 to 0 mmHg). To visualize Ca 2+ influx, RBCs were pre-loaded with an intensiometric probe Cal-520 AM, then imaged under a confocal microscope with concurrent bright-field and fluorescent imaging at acquisition rates of 10 frames per second. Remarkably, we observed the related changes in intracellular Ca 2+ levels immediately after aspirating individual RBCs in a pressure-dependent manner. The RBC aspirated by the water manometer only displayed 1.1-fold increase in fluorescence intensity, whereas the RBC aspirated by the pneumatic clamp showed up to threefold increase. These results demonstrated the water manometer as a gentle tool for cell manipulation with minimal pre-activation, while the high-speed pneumatic clamp as a much stronger pressure actuator to examine cell mechanosensing directly. Together, this multimodal platform enables us to precisely control aspiration and membrane tension, and subsequently correlate this with intracellular calcium concentration dynamics in a robust and reproducible manner.

Wang, Haoqing↗

Observation of Long-Lived UV-Induced Fluorescence from Environmental Materials Using the HVeV Detector as Developed for SuperCDMS

Here, we describe recent experiments using a SuperCDMS HVeV single-charge sensitive detector illuminated with an ultraviolet LED (275 nm) and a monochromatic laser(650 nm) using a dual fiber optic system installed in a small dilution refrigerator at Stanford University. We observed a population of fluorescence background events after UV exposure but not after exposure to the laser source. The fluorescence was likely due to scattered UV photons absorbed outside the detector. We discuss the possibility of fluorescence being a contributor to the low energy excess background observed in above-ground Dark Matter experiments.

36 MATERIALS SCIENCE↗

Synthesis and Characterization of Amorphous Lawsone Polymer Dots for Fluorescent Applications

In this work, a two-step hydrothermal/solvothermal process was developed to generate highly fluorescent lawsone polymer dots (LPDs) utilizing an inexpensive and abundant starting material, 2-hydroxy-1,4-napththoquinone (lawsone). This hydrothermal/solvothermal process produces LPDs that have excitation independent emission with well-defined electronic transitions. This two-step protocol provides a straightforward approach to remove unwanted small molecular fluorescence, which has plagued carbon dot systems, without the need for advanced chromatographic purification methods or steps. A series of spectroscopic, electrochemical, and theoretical experiments suggest that this process proceeds via a sequential dehydration and dehydrogenation pathway to cross-link the lawsone into a carbon dot structure. This polymerization process helps to stabilize and favor certain electronic transitions inherently present in the lawsone monomer. The generation of the LPDs results in a 2 order of magnitude increase in the emission intensity and a quantum yield of 37%. This behavior is likely the result of the cross-linked structure shielding these electronic states from deactivation caused by nonradiative processes such as vibrational coupling and excited state quenching from thermal deactivation and solvent collisions. This finding is consistent with a cross-linked enhanced emission (CEE) mechanism, as previously observed for other similar systems. The LPDs were then incorporated into a TiO2 photoanode and utilized as a photosensitizer in a dye-sensitized solar cell (DSSC) which showed an enhancement in photocurrent density over pure TiO2. We also prepared a derivative of the LPDs utilizing a diethylene triamine additive (nitrogen-doped lawsone polymer dots (N-LPDs)) using the same two-step protocol and demonstrated its potential as a fluorescence microscopy dye for imaging MDA-MB-231 cancer cells.

36 MATERIALS SCIENCE↗

Conical Intersection Accessibility Dictates Brightness in Red Fluorescent Proteins

Red fluorescent protein (RFP) variants are highly sought after for in-vivo imaging since longer wavelengths improve depth and contrast in fluorescence imaging. However, the lower energy emission wavelength usually correlates with a lower fluorescent quantum yield compared to their green emitting counterparts. To guide the rational design of bright variants, we have theoretically assessed two variants (mScarlet and mRouge) which are reported to have very different brightness. Using an α-CASSCF QM/MM framework (chromophore and all protein residues within 6 Å of it in the QM region, for a total of more than 450 QM atoms), we identify key points on the ground and first excited state potential energy surfaces. The brighter variant mScarlet has a rigid scaffold, and the chromophore stays largely planar on the ground state. The dimmer variant mRouge shows more flexibility and can accommodate a pre-twisted chromophore conformation which provides easier access to conical intersections. Notably, the main difference between the variants lies in the intersection seam regions, which appear largely inaccessible in mScarlet but partially accessible in mRouge. This observation is mainly related with changes in the cavity charge distribution, the hydrogen-bonding network involving the chromophore and a key ARG/THR mutation (which changes both charge and steric hindrance).

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Chromophore carbonyl twisting in fluorescent biosensors encodes direct readout of protein conformations with multicolor switching

Fluorescent labeling of proteins is a powerful tool for probing structure-function relationships with many biosensing applications. Structure-based rules for systematically designing fluorescent biosensors require understanding ligand-mediated fluorescent response mechanisms which can be challenging to establish. We installed thiol-reactive derivatives of the naphthalene-based fluorophore Prodan into bacterial periplasmic glucose-binding proteins. Glucose binding elicited paired color exchanges in the excited and ground states of these conjugates. X-ray structures and mutagenesis studies established that glucose-mediated color switching arises from steric interactions that couple protein conformational changes to twisting of the Prodan carbonyl relative to its naphthalene plane. Mutations of residues contacting the carbonyl can optimize color switching by altering fluorophore conformational equilibria in the apo and glucose-bound proteins. A commonly accepted view is that Prodan derivatives report on protein conformations via solvatochromic effects due to changes in the dielectric of their local environment. Here we show that instead Prodan carbonyl twisting controls color switching. These insights enable structure-based biosensor design by coupling ligand-mediated protein conformational changes to internal chromophore twists through specific steric interactions between fluorophore and protein.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Simultaneous quantification of uranium( VI ), samarium, nitric acid, and temperature with combined ensemble learning, laser fluorescence, and Raman scattering for real-time monitoring

In this work, laser-induced fluorescence spectroscopy (LIFS), Raman spectroscopy, and a stacked regression ensemble was developed for near real-time quantification of uranium(VI) (1–100 μg mL –1 ), samarium (0–200 μg mL –1 ) and nitric acid (0.1–4 M) with varying temperature (20 °C–45 °C). LIFS applications range from fundamental lab-scale studies to real-time process monitoring at industrial levels, such as nuclear reprocessing applications, provided the phenomena affecting the fluorescence spectrum are accounted for (e.g., absorption, quenching, complexation). Multiple chemometric models were examined and compared to a more traditional multivariate regression approach called partial least squares (PLS). Results obtained on synthetic samples selected using D-optimal experimental design indicated that a stacked regression method, which included ridge regression, random forest, PLS, and an eXtreme gradient boost algorithm, successfully measured uranium(VI) concentrations directly in nitric acid without measuring luminescence lifetimes or standard addition. The top model resulted in percent root-mean-square error of prediction values of 5.2, 1.9, 3.0, and 2.3% for U(VI), Sm 3+ , HNO 3 , and temperature, respectively. The approach may be useful for quantifying fluorescent fission products (e.g., Sm 3+ ) to provide information on burnup of irradiated nuclear fuel. This novel framework reinforces the applicability of LIFS for real-time applications in nuclear fuel cycle applications.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Fluorescent, phosphorescent, magnetic resonance contrast and radioactive tracer labelling of extracellular vesicles

This review focusses on the significance of fluorescent, phosphorescent labelling and tracking of extracellular vesicles (EVs) for unravelling their biology, pathophysiology, and potential diagnostic and therapeutic uses. Various labeling strategies, such as lipid membrane, surface protein, luminal, nucleic acid, radionuclide, quantum dot labels, and metal complex-based stains, are evaluated for visualizing and characterizing EVs. Direct labelling with fluorescent lipophilic dyes is simple but generally lacks specificity, while surface protein labelling offers selectivity but may affect EV-cell interactions. Luminal and nucleic acid labelling strategies have their own advantages and challenges. Here, each labelling approach has strengths and weaknesses, which require a suitable probe and technique based on research goals, but new tetranuclear polypyridylruthenium(II) complexes as phosphorescent probes have strong phosphorescence, selective staining, and stability. Future research should prioritize the design of novel fluorescent probes and labelling platforms that can significantly enhance the efficiency, accuracy, and specificity of EV labeling, while preserving their composition and functionality. It is crucial to reduce false positive signals and explore the potential of multimodal imaging techniques to gain comprehensive insights into EVs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluorescence intensity correlation imaging with high spatial resolution and elemental contrast using intense x-ray pulses

We theoretically investigate the fluorescence intensity correlation (FIC) of Ar clusters and Mo-doped iron oxide nanoparticles subjected to intense, femtosecond, and sub-femtosecond x-ray free-electron laser pulses for high-resolution and elemental contrast imaging. We present the FIC of Kα and Kαh emission in Ar clusters and discuss the impact of sample damage on retrieving high-resolution structural information and compare the obtained structural information with those from the coherent diffractive imaging (CDI) approach. We found that, while sub-femtosecond pulses will substantially benefit the CDI approach, few-femtosecond pulses may be sufficient for achieving high-resolution information with the FIC. Furthermore, we show that the fluorescence intensity correlation computed from the fluorescence of the Mo atoms in Mo-doped iron oxide nanoparticles can be used to image dopant distributions in the nonresonant regime.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low-cost production method for fluorescent particles for liquid flow velocimetry applications

Abstract In this Technical Note, we present a simple and low-cost production method for fluorescent particles perfectly suitable for velocimetry applications. We leverage the unique ability of Nile Red (NR) fluorophores to adsorb on the polymer surface and/or embed itself in between polymeric chains. The laboratory procedure to dye polyamide particles with NR and monetary advantages over commercially available fluorescent particles is outlined. Subsequently, the fluorescence behavior of the dyed particles is tested under a laser illumination source in polar and non-polar liquids. The distinct advantage of the emission spectrum of NR-dyed particles is demonstrated with sample test results.

42 ENGINEERING↗

Structural basis for ring-opening fluorescence by the RhoBAST RNA aptamer

Abstract Tagging RNAs with fluorogenic aptamers has enabled imaging of transcripts in living cells, revealing novel aspects of RNA metabolism and dynamics. While a diverse set of fluorogenic aptamers has been developed, a new generation of aptamers uses the ring-opening of spirocyclic rhodamine dyes to achieve robust performance in live mammalian cells. These fluorophores have two chemical states: a cell-permeable spirocyclic state and a fluorescent zwitterionic state. The SpyRho555 dye is mostly non-fluorescent in solution and becomes fluorescent in complex with the RhoBAST aptamer. To understand the basis for RhoBAST-SpyRho555 fluorogenicity, we have determined crystal structures of RhoBAST in complex with 5-carboxytetramethylrhodamine and a SpyRho555 analogue, MaP555. RhoBAST is organized by a perfect four-way junction that positions two loops to form the dye-binding pocket. The core of the ligand resides between a tri-adenine floor and a single guanine base, largely driven by π-stacking interactions. Importantly, the unpaired guanine interacts with the 3-position group of MaP555 to stabilize the open conformation, supported by mutagenesis data, and may play an active role in promoting the open conformation of the dye. This work has implications for the development of new fluorogenic aptamers with improved properties using structure-guided design approaches.

Biochemistry & Molecular Biology↗

Demonstrating Agreement between Radio and Fluorescence Measurements of the Depth of Maximum of Extensive Air Showers at the Pierre Auger Observatory

We show, for the first time, radio measurements of the depth of shower maximum ( X max ) of air showers induced by cosmic rays that are compared to measurements of the established fluorescence method at the same location. Using measurements at the Pierre Auger Observatory we show full compatibility between our radio and the previously published fluorescence dataset, and between a subset of air showers observed simultaneously with both radio and fluorescence techniques, a measurement setup unique to the Pierre Auger Observatory. Furthermore, we show radio X max resolution as a function of energy and demonstrate the ability to make competitive high-resolution X max measurements with even a sparse radio array. With this, we show that the radio technique is capable of cosmic-ray mass composition studies, both at Auger and at other experiments. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fluorescence Assay for Tolyporphins Amidst Abundant Chlorophyll in Crude Cyanobacterial Extracts

Abstract Tolyporphins are distinctive tetrapyrrole natural products found singularly in a filamentous cyanobacterial‐microbial holobiont (termed HT‐58‐2) from Micronesia. The absorption and fluorescence features of tolyporphins resemble those of chlorophyll a , complicating direct analysis of culture samples. Treatment of the crude (unfractionated) organic extract (CH 2 Cl 2 /2‐propanol, 1:1) of HT‐58‐2 cultures with NaBH 4 in methanol causes reduction of the peripheral ketone auxochromes, whereupon tolyporphins (predominantly 7,17‐dioxobacteriochlorins) exhibit a bathochromic shift ( λ abs ˜ 676 → ˜ 700 nm) and chlorophyll a (a 13 1 ‐oxochlorin) exhibits a hypsochromic shift ( λ abs 665 → 634 nm). Fluorescence excitation spectroscopy (at 368 and 491 nm with λ em 710 nm) enabled detection of reduced tolyporphins amidst abundant reduced chlorophyll a (1:19 ratio), a detection sensitivity >5 times that without reduction. The resulting assay combines simple sample preparation from non‐axenic cultures at microscale quantities (2 mL, 2 μ m ), absence of any fractionation procedures, and fluorescence detection. Tolyporphins were readily detected in cultures of HT‐58‐2 at reasonable growth periods in the absence of environmental stressors, which was not possible previously.

Nguyen, Kathy‐Uyen↗

Substituent effect on napthodithiophene-fused porphyrins: Understanding the unusual trend of fluorescence quantum yield quenching

A series of π-extended porphyrins containing thiophene units was prepared to investigate an unusual trend observed in the fluorescence quantum yield of naphtho[2,1-b:3,4-b']dithiophene-fused porphyrins. Monobenzoporphyrins carrying 2-thiophenyl (vinyl thiophene porphyrin) groups (2VTP, 2VTBr and Br2VTP) (numbering 2 and 3 refers to the position of sulfur on the thiophene ring) were synthesized through a Heck-based cascade reaction followed by a newly developed bromination method. These were converted to naphtho[2,1-b:3,4-b']dithiophene-fused porphyrin derivatives (FBr2VTP and F2VTBr) via ring closure with an intramolecular Scholl reaction. Increasingly larger Stokes shifts with a higher number of bromo groups were observed in the unfused π-extended molecular systems, reflecting the heavy atom effect. Fluorescence spectroscopy further confirmed the unusual trend seen in the previous work: structural rigidification in naphtho[2,1-b:3,4-b']dithiophene-fused porphyrins leads to longer fluorescence lifetimes but unexpectedly lowers the quantum yield. Adding one bromo group to the naphtho[2,1-b:3,4-b']dithiophene unit does not change this trend. Furthermore, the presence of two bromo groups prevents the quantum yield from dropping. DFT, TDDFT, and NICS analyses suggest a drastic change in aromaticity in the pyrrole ring where the naphtho[2,1-b:3,4-b']dithiophene is fused in FBr2VTP, which might contribute to the quantum yield reductions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Computational microscopy for fast widefield deep-tissue fluorescence imaging using a commercial dual-cannula probe

A solid-glass cannula serves as a micro-endoscope that can deliver excitation light deep inside tissue while also collecting emitted fluorescence. Then, we utilize deep neural networks to reconstruct images from the collected intensity distributions. By using a commercially available dual-cannula probe, and training a separate deep neural network for each cannula, we effectively double the field of view compared to prior work. We demonstrated ex vivo imaging of fluorescent beads and brain slices and in vivo imaging from whole brains. We clearly resolved 4 µm beads, with FOV from each cannula of 0.2 mm (diameter), and produced images from a depth of ∼1.2 mm in the whole brain, currently limited primarily by the labeling. Since no scanning is required, fast widefield fluorescence imaging limited primarily by the brightness of the fluorophores, collection efficiency of our system, and the frame rate of the camera becomes possible.

42 ENGINEERING↗

FLIMJ: An open-source ImageJ toolkit for fluorescence lifetime image data analysis

In the field of fluorescence microscopy, there is continued demand for dynamic technologies that can exploit the complete information from every pixel of an image. One imaging technique with proven ability for yielding additional information from fluorescence imaging is Fluorescence Lifetime Imaging Microscopy (FLIM). FLIM allows for the measurement of how long a fluorophore stays in an excited energy state, and this measurement is affected by changes in its chemical microenvironment, such as proximity to other fluorophores, pH, and hydrophobic regions. This ability to provide information about the microenvironment has made FLIM a powerful tool for cellular imaging studies ranging from metabolic measurement to measuring distances between proteins. The increased use of FLIM has necessitated the development of computational tools for integrating FLIM analysis with image and data processing. To address this need, we have created FLIMJ, an ImageJ plugin and toolkit that allows for easy use and development of extensible image analysis workflows with FLIM data. Built on the FLIMLib decay curve fitting library and the ImageJ Ops framework, FLIMJ offers FLIM fitting routines with seamless integration with many other ImageJ components, and the ability to be extended to create complex FLIM analysis workflows. Building on ImageJ Ops also enables FLIMJ’s routines to be used with Jupyter notebooks and integrate naturally with science-friendly programming in, e.g., Python and Groovy. We show the extensibility of FLIMJ in two analysis scenarios: lifetime-based image segmentation and image colocalization. We also validate the fitting routines by comparing them against industry FLIM analysis standards.

47 OTHER INSTRUMENTATION↗

Development of High Energy Resolution Fluorescence Detection Methods for Advanced Microscale X-ray Absorption Fine Structure Analysis of Critical Elements (Final Report)

This project is developing High-Energy Resolution Fluorescence Detection (HERFD) X-ray Absorption Fine-Structure Spectroscopy (XAFS) at the hard X-ray microprobe beamline at GSECARS beamline 13-ID-E, at the Advanced Photon Source at Argonne National Laboratory. This enhancement will improve sensitivity and spectral interpretation limitations of conventional XAFS which uses energy dispersive solid-state detectors (SSD) to measure the total fluorescence yield (TFY-XAFS). By using high-quality Si and Ge crystal analyzers to select X-ray fluorescence (XRF) from specific emission lines, background signals from other elements or X-ray scattering that can paralyze SSDs can be nearly eliminated, improving the sensitivity to the oxidation and chemical state of dilute species even though the solid angle of the analyzers is relatively small. Furthermore, by using analyzers of low-strain Si or Ge, the energy selection can be smaller than the natural widths of the core electron level. We are particularly interested in applying these enhanced sensitivities to Lanthanide series of rare-earth elements, which are typically at concentrations at or below 10 ppm, and where spectral overlaps with the 3rd row transition metals degrade sensitivity.

47 OTHER INSTRUMENTATION↗

Upgrading Linear Fluorescent Fixtures to LED in Schools

Lighting is a key component to creating a functional and high-quality learning environment for students and staff. Light-emitting diode or LED lighting fixtures have gained traction in common commercial building applications and quality replacement options for common fixture types are widely available. Compared to most fluorescent lighting systems, using LEDs can reduce energy consumption and therefore decrease carbon dioxide emissions, reduce maintenance and operation cost, and improve the visual appearance and lighting quality of the classroom and school environments. When additional controls are considered, more energy can be saved and some controls, like dimming, can offer amenities to occupants. As LEDs become an even more prominent lighting technology, fluorescent equipment may become challenging or expensive to replace. Additionally, school buildings are typically in use for many decades; maintaining a long-term view can be important when deciding which upgrade path to take. This fact sheet provides guidance on the various factors to consider when deciding on an LED upgrade for fluorescent lighting systems.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inactivation of Fluorescent Lipid Bilayers by Irradiation With 300 keV Electrons Using Liquid Cell Transmission Electron Microscopy

Liquid cell transmission electron microscopy allows for imaging of samples in a fully hydrated state at high resolution and has the potential for visualizing static or dynamic biological structures. However, the ionizing nature of the electron beam makes it difficult to discern real physiological dynamics from radiation induced artifacts within liquid cell samples. Electron flux thresholds for achieving high resolution structures from biological samples frozen in ice have been described extensively by the cryo-electron microscopy field, while electron flux thresholds which do not result in a functional change for biological samples within the hydrated environment of a transmission electron microscope liquid cell is less clear. Establishing these functional thresholds for biologically relevant samples is important for accurate interpretation of results from liquid cell experiments. Here we demonstrate the electron damage threshold of fluorescently tagged lipid bilayers by quantifying the change in fluorescence before and after electron exposure. We observe the reduction of fluorescent signal in bilayers by 25% after only 0.0005 e − /Å 2 and a reduction of over 90% after 0.01 e − /Å 2 . These results indicate that the loss of function occurs at irradiation thresholds far below a typical single high resolution (scanning) transmission electron microscopy image and orders of magnitude below fluxes used for preserving structural features with cryo-electron microscopy.

Moser, Trevor↗