Electronics for a focal plane crystal spectrometer

The HEAO-B program forced the usual constraints upon the spacecraft experiment electronics: high reliability, low power consumption, and tight packaging at reasonable cost. The programmable high voltage power supplies were unique in both application and simplicity of manufacture. The hybridized measurement chain is a modification of that used on the SAS-C program; the charge amplifier design in particular shows definite improvement in performance over previous work.

Goeke, R. F.↗

Focal plane transport assembly controls for the High Energy Astronomy Observatory X-ray telescope

The High Energy Astronomy Observatory - Mission B (HEAO-B) is a satellite observatory for the purpose of performing a detailed X-ray survey of the celestial sphere. Measurements will be made of stellar radiation in the range of 0.2 to 20 keV. The central part of the Observatory is an X-ray telescope, into the focus of which a variety of imaging instruments and spectrographs may be introduced. The telescope has a resolution of about 1 arc second, so that the instruments must be placed with extreme precision. This is obtained by a mechanical system of toggles and stops and a motor drive system controlled by a position sensing potentiometer with a resolution of about 1.5 degrees

Carpenter, C.↗

Improved charge injection device and a focal plane interface electronics board for stellar tracking

An improved Charge Injection Device (CID) stellar tracking sensor and an operating sensor in a control/readout electronics board were developed. The sensor consists of a shift register scanned, 256x256 CID array organized for readout of 4x4 subarrays. The 4x4 subarrays can be positioned anywhere within the 256x256 array with a 2 pixel resolution. This allows continuous tracking of a number of stars simultaneously since nine pixels (3x3) centered on any star can always be read out. Organization and operation of this sensor and the improvements in design and semiconductor processing are described. A hermetic package incorporating an internal thermoelectric cooler assembled using low temperature solders was developed. The electronics board, which contains the sensor drivers, amplifiers, sample hold circuits, multiplexer, analog to digital converter, and the sensor temperature control circuits, is also described. Packaged sensors were evaluated for readout efficiency, spectral quantum efficiency, temporal noise, fixed pattern noise, and dark current. Eight sensors along with two tracker electronics boards were completed, evaluated, and delivered.

Michon, G. J.↗

Lead sulfide - Silicon MOSFET infrared focal plane development

A process for directly integrating photoconductive lead sulfide (PbS) infrared detector material with silicon MOS integrated circuits has been developed primarily for application in long (greater than 10,000 detector elements) linear arrays for pushbroom scanning applications. The processing technology is based on the conventional PMOS and CMOS technologies with a variation in the metallization. Results and measurements on a fully integrated eight-element multiplexer are shown.

Barrett, J. R.↗

Focal plane optics in far-infrared and submillimeter astronomy

The construction of airborne observatories, high mountain-top observatories, and space observatories designed especially for infrared and submillimeter astronomy has opened fields of research requiring new optical techniques. A typical far-IR photometric study involves measurement of a continuum spectrum in several passbands between approx 30 microns and 1000 microns and diffraction-limited mapping of the source. At these wavelengths, diffraction effects strongly influence the design of the field optics systems which couple the incoming flux to the radiation sensors (cold bolometers). The Airy diffraction disk for a typical telescope at submillimeter wavelengths approx 100 microns-1000 microns is many millimeters in diameter; the size of the field stop must be comparable. The dilute radiation at the stop is fed through a Winston nonimaging concentrator to a small cavity containing the bolometer. The purpose of this paper is to review the principles and techniques of infrared field optics systems, including spectral filters, concentrators, cavities, and bolometers (as optical elements), with emphasis on photometric systems for wavelengths longer than 60 microns.

Hildebrand, R. H.↗

Space infrared telescope facility (SIRTF) focal plane

The Infrared Array Camera (IRAC), Multiband Imaging Photometer (MIP), and the Infrared Spectrometer (IRS) of the Space Infrared Telescope Facility (SIRTF) are described. The configuration and capabilities of the SIRTF are discussed. The small silicon array module, the germanium array module, and bolometer module of MIP, which is designed to provide sensitivity limited only by natural background and telescope emissions over the 3-200 micron spectral range, and allow diffraction limited imaging, super resolution techniques, mapping, and surveying, are examined. The objectives and design of the IRAC, which is constructed for two-dimensional photometry and imaging over a wavelength region from 2-30 microns and to perform extragalactic, galactic and solar system astronomy, are studied. The use of the IRS to study the dynamical and physical phenomena of the universe in the 2.5-200 micron range is analyzed.

Ramos, R.↗

Focal plane optics in far-infrared and submillimeter astronomy

The construction of airborne observatories, high mountain-top observatories, and space observatories designed especially for infrared and submillimeter astronomy has opened fields of research requiring new optical techniques. A typical far-IR photometric study involves measurement of a continuum spectrum in several passbands between approx 30 microns and 1000 microns and diffraction-limited mapping of the source. At these wavelengths, diffraction effects strongly influence the design of the field optics systems which couple the incoming flux to the radiation sensors (cold bolometers). The Airy diffraction disk for a typical telescope at submillimeter wavelengths approx 100 microns-1000 microns is many millimeters in diameter; the size of the field stop must be comparable. The dilute radiation at the stop is fed through a Winston nonimaging concentrator to a small cavity containing the bolometer. The purpose of this paper is to review the principles and techniques of infrared field optics systems, including spectral filters, concentrators, cavities, and bolometers (as optical elements), with emphasis on photometric systems for wavelengths longer than 60 microns.

Hildebrand, R. H.↗

Tests of HgCdTe-on-sapphire focal plane arrays

The general architecture of the imaging array, some merits of HgCdTe-on-sapphire as a detector material, and the current status of the laboratory tests and the Short Wave Infrared (SWIR) camera are described.

Hereld, M.↗

Design and performance of 4 x 5120-element visible and 2 x 2560-element shortwave infrared multispectral focal planes

Two solid-state sensors for use in remote sensing instruments operating in the pushbroom mode are examined. The design and characteristics of the visible/near-infrared (VIS/NIR) device and the short-wavelength infrared (SWIR) device are described. The VIS/NIR is a CCD imager with four parallel sensor lines, each 1024 pixel long; the chip design and filter system of the VIS/NIR are studied. The performance of the VIS/NIR sensor with mask and its system performance are measured. The SWIR is a dual-band line imager consisting of palladium silicide Schottky-barrier detectors coupled to CCD multiplexers; the performance of the device is analyzed. The substrate materials and layout designs used to assemble the 4 x 5120-element VIS/NIR array and the 2 x 2560-element SWIR array are discussed, and the planarity of the butted arrays are verified using a profilometer. The optical and electrical characteristics, and the placement and butting accuracy of the arrays are evaluated. It is noted that the arrays met or exceed their expected performance.

Tower, J. R.↗

Intensified-CCD focal plane detector for space applications A second generation

An intensified-CCD detector system developed for space applications from commercially available components is described. This detector uses components which are readily available and are mechanically, thermally, and optically coupled to produce the final compact system. The CCD is cooled using a Peltier-effect thermoelectric cooler to reduce thermal noise. The image is formed on the photocathode of a proximity-focused image intensifier and is transferred fiber-optically from the intensifier to the CDD. Various photocathode and window materials are used to optimize the system for use within the wavelength range extending from the far UV to the near IR. The basic design, including the image intensifier, intensifier-CCD interface, CCD array, cooling, electronics, and mounting, and the detector performance are described in detail.

Torr, M. R.↗

The focal plane reception pattern calculation for a paraboloidal antenna with a nearby fence

A computer simulation program is described which is used to estimate the effects of a proximate diffraction fence on the performance of paraboloid antennas. The computer program is written in FORTRAN. The physical problem, mathematical formulation and coordinate references are described. The main control structure of the program and the function of the individual subroutines are discussed. The Job Control Language set-up and program instruction are provided in the user's instruction to help users execute the present program. A sample problem with an appropriate output listing is made available as an illustration of the usage of the program.

Schmidt, Richard F.↗

Focal plane array technologies for NASA space systems

A development status evaluation is presented for solid-state self-scanned imaging arrays applicable to NASA space science missions, giving attention to the visible and IR spectral range (0.5-1000 microns). Shortward of 1.1 micron, Si CCDs will continue to be used. Beyond 10 microns, the challenge for NASA researchers lies in the development of a class of detectors that can dispense with the conventional cooling to below 10 K. Above 25 microns, extrinsic Ge detectors will be used, and beyond 200 microns, a novel extrinsic material such as GaAs will have to be developed for this application.

Cutts, James A.↗

The Stellar X-ray Polarimeter - A focal plane polarimeter for the Spectrum X-Gamma mission

This paper describes an X-ray polarimeter that will be flown on the Spectrum X-Gamma mission. The instrument exploits three distinct physical processes to measure polarization: Bragg reflection from a graphite crystal, Thomson scattering from a metallic lithium target, and photoemission from a cesium iodide photocathode. These three methods allow polarization measurements over an energy band from 0.3 to 12 keV. The polarimeter will make possible sensitive measurements of several hundred known X-ray sources. X-ray polarization measurements will make it possible to constrain the geometry of gas flow in X-ray binaries, identify nonthermal emission in supernova remnants, test current models for X-ray emission in radio pulsars, determine the radiation mechanisms in active galactic nuclei, and search for inertial frame dragging (Lense-Thirring effect) around the putative black hole in Cygnus X-1.

Kaaret, P.↗

An abuttable CCD imager for visible and X-ray focal plane arrays

A frame-transfer silicon charge-coupled-device (CCD) imager has been developed that can be closely abutted to other imagers on three sides of the imaging array. It is intended for use in multichip arrays. The device has 420 x 420 pixels in the imaging and frame-store regions and is constructed using a three-phase triple-polysilicon process. Particular emphasis has been placed on achieving low-noise charge detection for low-light-level imaging in the visible and maximum energy resolution for X-ray spectroscopic applications. Noise levels of 6 electrons at 1-MHz and less than 3 electrons at 100-kHz data rates have been achieved. Imagers have been fabricated on 1000-Ohm-cm material to maximize quantum efficiency and minimize split events in the soft X-ray regime.