Search NASA⌕ Search

SEARCH · Search NASA

Results for “forced cooling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Direct observation of anisotropic growth of water films on minerals driven by defects and surface tension

Knowledge of the occurrences of water films on minerals is critical for global biogeochemical and atmospheric processes, including element cycling and ice nucleation. The underlying mechanisms controlling water film growth are, however, misunderstood. Using infrared nanospectroscopy, amplitude-modulated atomic force microscopy, and molecular simulations, we show how water films grow from water vapor on hydrophilic mineral nanoparticles. We imaged films with up to four water layers that grow anisotropically over a single face. Growth usually begins from the near edges of a face where defects preferentially capture water vapor. Thicker films produced by condensation cooling completely engulf nanoparticles and form thicker menisci over defects. The high surface tension of water smooths film surfaces and produces films of inhomogeneous thickness. Nanoscale topography and film surface energy thereby control anisotropic distributions and thicknesses of water films on hydrophilic mineral nanoparticles.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Measurement of the Emittance for the CeC Project

Coherent Electron Cooling (CeC) experiment was carried out at RHIC [1]. It required small emi ance of 10-15 MeV electron beam with high peak current. In most cases the emi ance was measured by either quadrupole or solenoid scan. For a low-energy beam with high peak current the measurements are affected by space charge forces. To overcome these difficul es the pepper-pot [2,3] or slit scan [4] can be used.

43 PARTICLE ACCELERATORS↗

Numerical Simulation of a Natural Convection–Driven Air-Cooled Reactor Cavity Cooling System Experiment

Ensuring the efficient removal of decay heat from the reactor vessel is essential for the safety of advanced reactor technologies. Several Generation-IV concepts incorporate variations in the reactor vessel cooling systems to achieve this objective. High-temperature gas-cooled reactors utilize a reactor cavity cooling system (RCCS), a passive ex-vessel system designed to operate without active components or external power during accident conditions. The RCCS removes decay heat primarily through radiative and convective heat transfer mechanisms. Here, this study presents a comprehensive validation of a computational fluid dynamics Reynolds-averaged Navier-Stokes model for the University of Wisconsin-Madison air-cooled RCCS facility. Validation was conducted for both high- and low-power natural convection cases under a uniform heating profile. Near-wall resolution was found to be critical for accurately modeling natural convection in the RCCS; employing an all-𝑦 + wall treatment resulted in wall temperature discrepancies exceeding 50 °⁢𝐶 compared to a wall-resolved mesh. Thermal-hydraulic behaviors under natural and forced convection conditions were compared within the heated cavity and RCCS. A turbulence model sensitivity analysis indicated that low-Reynolds number k-ɛ, k-ω shear stress transport (SST), and Reynolds stress transport models produce similar wall temperature predictions. A buoyancy modeling sensitivity study revealed that the Boussinesq approximation significantly underpredicted thermal-hydraulic behavior in the RCCS. Based on these findings, modeling recommendations are provided. The validated data set along with identified sensitivities refine the modeling of natural convection in the RCCS. The information produced by this study supports RCCS design, optimization, and safety evaluations, enabling the calibration and verification of reduced-order thermal-hydraulic models.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Interactions Between Climate Mean and Variability Drive Future Agroecosystem Vulnerability

ABSTRACT Agriculture is crucial for global food supply and dominates the Earth's land surface. It is unknown, however, how slow but relentless changes in climate mean state, versus random extreme conditions arising from changing variability , will affect agroecosystems' carbon fluxes, energy fluxes, and crop production. We used an advanced weather generator to partition changes in mean climate state versus variability for both temperature and precipitation, producing forcing data to drive factorial‐design simulations of US Midwest agricultural regions in the Energy Exascale Earth System Model. We found that an increase in temperature mean lowers stored carbon, plant productivity, and crop yield, and tends to convert agroecosystems from a carbon sink to a source, as expected; it also can cause local to regional cooling in the earth system model through its effects on the Bowen Ratio. The combined effect of mean and variability changes on carbon fluxes and pools was nonlinear, that is, greater than each individual case. For instance, gross primary production reduces by 9%, 1%, and 13% due to change in mean temperature, change in temperature variability, and change in both temperature mean and variability, respectively. Overall, the scenario with change in both temperature and precipitation means leads to the largest reduction in carbon fluxes (−16% gross primary production), carbon pools (−35% vegetation carbon), and crop yields (−33% and −22% median reduction in yield for corn and soybean, respectively). By unambiguously parsing the effects of changing climate mean versus variability and quantifying their nonadditive impacts, this study lays a foundation for more robust understanding and prediction of agroecosystems' vulnerability to 21st‐century climate change.

54 ENVIRONMENTAL SCIENCES↗

Use Cases and Model Development of Thermal Storage Coupling for Advanced Nuclear Reactors

This report discusses the different options for coupling thermal energy storage (TES) systems to advanced nuclear power plants (A-NPPs) in order to enable flexible and hybrid plant operation. An advanced light-water reactor (ALWR) and a high-temperature gas-cooled reactor (HTGR) were selected as the initial use cases for demonstrating a thermally balanced energy storage coupling design for thermal power extraction. Cost functions for the A-LWR were derived from the fully balanced models that were developed based on three different coupling options with three different thermal energy bypass ratios. For the next steps, cost functions for the HTGR will also be derived, and additional nuclear reactors (e.g., a liquid-cooled fast reactor [LFR] or molten-salt reactor [MSR]) will be evaluated for coupling with TES in similar fashion, including the evaluation of their steady-state condition models and cost functions. The models presented herein showcase several design considerations, focusing on optimal deployment methodologies for achieving steady-state operation with minimum disruption to the nuclear power generation cycle. This report presents the results of steady state models developed using Aspen HYSYS®, wherein the thermal energy bypass for an NPP-TES coupling was varied up to 50%. The various components were sized using Aspen Process Economic Analyzer (APEA) and Aspen Exchanger Design and Rating (EDR), when applicable. Cost functions from these models were developed using the latest publicly available data obtained from APEA V11. The current steady-state models and cost functions provide a baseline for additional work focusing on dynamic operation and process optimization by using Idaho National Laboratory (INL)’s Framework for Optimization of Resources and Economics (FORCE) tools to evaluate the technoeconomic viability and transient operations of TES-coupled A-NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Spontaneous Symmetry–Breaking of Nonequilibrium Steady–States Caused by Nonlinear Electrical Transport

Negative differential resistance (NDR) in certain materials has been attributed to spontaneous emergence of symmetry-breaking electrical current density localization from a previously homogeneous distribution, which is postulated to occur due to the nonequilibrium thermodynamic force of minimization of entropy production. However, this phenomenon has not been quantitatively predicted based on intrinsic material properties and an applied electrical stimulus. Herein an instability criterion is derived for localization of current density and temperature from a thermal fluctuation in a parallel conductor model of a thin film that is subject to Newton's law of cooling. The conditions for steady–state electro-thermal localization is predicted, verifying a decrease in entropy production upon localization. Electro-thermal localization accompanied by a decrease of entropy production is confirmed in a multiphysics simulation of current flow in a thin film. The instability criterion predicts conditions for spontaneous current density localization, relating symmetry breaking fundamentally to dynamical instability via Local Activity theory.

36 MATERIALS SCIENCE↗

Oxide evolution on the SiC layer of TRISO particles during extended air oxidation

Tristructural isotropic (TRISO) fuel particles have been primarily developed for high-temperature gas-cooled nuclear reactors and can be subjected to oxidizing environments for extended periods in an off-normal accident scenario. Surrogate TRISO fuel particles were oxidized in air at 1,000 or 1,100 °C for up to 120 h. Here, the oxide scale morphology and thickness were studied via scanning electron microscopy, focused ion beam, and atomic force microscopy. TRISO particles oxidized at 1,100 °C exhibited a highly crystalline oxide scale, which led to significant cracking and irregularly shaped closed porosity, whereas those oxidized at 1,000 °C possessed a primarily amorphous oxide scale, which contained small, rounded internal pores and no larger defects. The observed phenomena deviated from the expected behavior based on models for oxide growth on flat-plate and fiber SiC. The oxidation kinetics of TRISO fuel particles in high-temperature air were investigated without mechanically deforming the surface and were analyzed with respect to oxide morphology.

36 MATERIALS SCIENCE↗

SAS4A/SASSYS-1 Commercial Grade Dedication Example Report for a Generic Sodium Pool-Type Fast Reactor Application

In the U.S., a key component of the commercialization of advanced reactors is completion of a license application, which must ultimately be approved by the Nuclear Regulatory Commission (NRC). The approval of the license application by the NRC is contingent on satisfactory demonstration of the design basis and the response of the advanced reactor design to transient and accident scenarios using accepted codes and methods. This report describes the qualification and dedication requirements that the advanced reactor safety analysis system software SAS4A/SASSYS-1 are expected to need to fulfill to be used for sodium-cooled pool-type fast reactor licensing. The qualification and dedication requirements are identified through performance critical characteristics and evaluation model acceptance criteria representative of the advanced reactor design considered for licensing. This document captures, additionally, the verification process developed to demonstrate that the software fulfills the qualification and dedication requirements for a generic sodium-cooled pool-type fast reactor as part of the commercial grade dedication process. Like most software that has primarily existed in the research and development space, the most significant challenge facing SAS4A/SASSYS-1 for use in a licensing framework is the availability of a documentation basis describing the code pedigree. SAS4A/SASSYS-1 has been used for licensing of the fast flux test facility (FFTF) and the JOYO sodium-cooled fast reactor in Japan, as well as the design of the CRBR Plant. However, the historical verification and validation (V&V) activities supporting SAS4A/SASSYS-1 development do not align with modern software quality assurance (SQA) and V&V requirements. Two approaches to use of SAS4A/SASSYS-1 in a commercial licensing framework have been identified: commercial-grade dedication (CGD) and software qualification. The methods and requirements prescribed in the ASME NQA-1-2008/2009 Standard and Regulatory Guide 1.203 on the evaluation model development and assessment process (EMDAP) have been used as guidance to define the CGD and qualification processes, respectively. A qualification and dedication requirements matrix has been developed which utilizes fundamental software verification. In this process, software verification is defined as a software quality process aimed at defining software requirement specifications, developing software design documentation, and performing and documenting acceptance testing of the code against requirements. A key element of software qualification and dedication includes determination of software acceptance with respect to critical characteristics relevant to the functional requirements of the software. To assist with identification of cross-cutting transient phenomena and functional requirements, domestic SFR vendor designs have been reviewed to identify a reference SFR design. For this report, the reference design is defined as a pool-type reactor with metal alloy fuel, a liquid-metal intermediate heat transport system, and passive decay heat rejection systems. Given this reference, a series of high-level cross-cutting phenomena was identified for a general class of single-fault undercooling or reactivity insertion transients that scopes the design basis space, with the goal of assisting with prioritization of documentation development efforts for key transient models in SAS: 1) Reactivity feedback response prior to scram; 2) System-wide thermal inertia; 3) Transition in natural circulation flow regime in heat removal systems; 4) Decay heat generation; 5) Steady-state fuel characterization; 5) Clad/fuel behavior at elevated temperatures; 6) Point kinetics and decay heat; 7) Pump coastdown behavior; 8) Core flow redistribution in loss of forced convection; 9) Pool stratification. As a demonstration of CGD of SAS4A/SASSYS-1 for a sodium pool reactor, a software qualification and dedication gap analysis as it relates to code documentation has been performed. This effort leverages the framework established as part of the SAS4A/SASSYS-1 SQA Program. This CGD demonstration provides a framework that vendors can build upon to demonstrate the applicability of the SAS4A/SASSYS-1 software for licensing a sodium-cooled pool-type fast reactor.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

3D CFD Model Validation Using Benchmark Data of 1/16th Scaled VHTR Upper Plenum and Development of Wall Heat-Transfer Correlation For Laminar Flow

With support from the U.S. Department of Energy-Office of Nuclear Energy’s (DOE-NE’s) Nuclear Energy Advanced Modeling and Simulation (NEAMS) program, an effort has been pursued to support high-temperature gas-cooled reactor (HTGR) technology development and its modeling and simulation needs. There is a particular need for advanced modeling and simulation tools to predict thermal-fluid behavior in the nuclear reactor primary system, especially in the core and the lower and upper plena, during safety-related transients. In this report, two main such activities are presented relevant to the HTGRs: (1) three-dimensional (3D) computational fluid dynamics (CFD) validation using benchmark data from the upper plenum of Texas A&M University’s 1/16th scaled very-high-temperature gas-cooled reactor (VHTR), and (2) development of wall heat-transfer correlation for laminar flow in a wall-heated pipe. The CFD tool validation exercises can be helpful to choose the models and CFD tools to simulate and design specific components of the HTRGs such as upper plenum where jet mixing is a complex phenomenon. In a loss of forced circulation event, the laminar flow can be observed during the development of natural circulation flow. This work includes the development and validation of heat transfer correlations for laminar flow using the Nek5000 CFD code due to limited available experimental data for laminar flow conditions to guide low-order models (1D). In this report, the flow characteristics of a single isothermal jet discharging into the upper plenum was investigated using the Nek5000 Large-Eddy Simulation (LES) CFD tool. Several numerical simulations were performed for various jet-discharged Reynolds numbers ranging from 3,413 to 12,819. A grid-independent study was performed. The numerical results of mean velocity, root-mean-square fluctuating velocity, and Reynolds stress were compared against the benchmark data. Good agreement was obtained between simulated and measured data for axial mean velocities, except near the upper plenum hemisphere. The maximum predicted errors for axial mean velocities at various normalized coolant channel diameter heights of 1, 5, and 10 are 1.56%, 1.88%, and 3.82%, respectively. In addition, the predicted root-mean-square fluctuating velocity and Reynolds stress are qualitatively in agreement with the experimental data. The Nek5000 code was used to develop wall-heat transfer correlation for laminar flow in a cylindrical tube. Several simulations were performed for various Reynolds flow and wall-heat fluxes. A new heat transfer correlation was developed using data from Nek5000 simulation results and regression functions in Matlab. The developed heat transfer correlation is valid for various Reynolds flows from 200 to 2000. The predicted R² value for model fit was 0.875, which ensures that 87.5% of the model data lies on the Nek5000 data. Moreover, a machine learning (ML) tool was used to train and test the Nek5000 data. A good fit of the ML-based model was observed with the test data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Perspective on the oil-dominated gas hydrate plugging conceptual picture as applied to transient Shut-In/Restart

Gas hydrate formation is rarely an issue during continuous production conditions. Unplanned and/or extended shut-downs comprise the majority of scenarios where overlapping concern and uncertainty for gas hydrate blockages exist. To date, most experimental studies and theoretical analysis of gas hydrate formation derive from the steady-state conceptual picture. Yet, significant distinctions induced by phase separation and prolonged cooling suggest an altered conceptual picture is required for transient shut-in/restart operations. To address this outstanding issue, this work presents a conceptual picture for the base case of a non-surface active hydrocarbon undergoing cold restart without enacted mitigation efforts. First, phase separation upon shut-in leads to the localization of gas hydrate ingredients due to fluids density differences and pipeline inclination. Cooling to the seafloor temperature, then, induces gas hydrate film formation at the hydrocarbon interface and maximizes subcooling, resulting in rapid and confined gas hydrate growth occurring upon restart. Furthermore, this ultimately leads to plugging dominated by the deposition of porous, low conversion gas hydrate masses. Direct visual observations and results from Raman spectroscopy, hydrate contact angle and film growth, micromechanical force apparatus, rocking cell, and flow loop studies support the mechanisms outlined within each step. Similar to the influence provided by the original Colorado School of Mines steady-state conceptual picture that was introduced about 15 years ago, this transient counterpart builds a foundation that could inspire new directions of hydrate research and analysis in areas where uncertainty abounds.

02 PETROLEUM↗

New Clues to the Evolution of Dwarf Carbon Stars From Their Variability and X-Ray Emission

As main-sequence stars with C > O, dwarf carbon (dC) stars are never born alone but inherit carbon-enriched material from a former asymptotic giant branch (AGB) companion. In contrast to M dwarfs in post-mass-transfer binaries, C 2 and/or CN molecular bands allow dCs to be identified with modest-resolution optical spectroscopy, even after the AGB remnant has cooled beyond detectability. Accretion of substantial material from the AGB stars should spin up the dCs, potentially causing a rejuvenation of activity detectable in X-rays. Indeed, a few dozen dCs have recently been found to have photometric variability with periods under a day. However, most of those are likely post-common-envelope binaries, spin–orbit locked by tidal forces, rather than solely spun-up by accretion. Here, we study the X-ray properties of a sample of the five nearest-known dCs with Chandra. Two are detected in X-rays, the only two for which we also detected short-period photometric variability. We suggest that the coronal activity detected so far in dCs is attributable to rapid rotation due to tidal locking in short binary orbits after a common-envelope phase, late in the thermally pulsing (TP) phase of the former C-AGB primary (TP-AGB).

79 ASTRONOMY AND ASTROPHYSICS↗

Numerical Analysis and Flow Induced Vibration Studies in Pressurized Helium Gas Cooling Channels

Los Alamos National Laboratory (LANL) is working with NorthStar Medical Radioisotopes (NMR) on their efforts to produce Mo-99 from the irradiation of Mo-100 targets. The NMR target consists of an Inconel window that allows the electron beam to penetrate and irradiate a stack of Mo-100 discs. The irradiation process generates large amounts of heat and is cooled using pressurized helium gas flowing at 400 g/s. LANL provides both numerical analysis support and experimental support. Computational fluid dynamics (CFD) simulations for both 300 g/s and 400 g/s are performed on the NMR target to analyze the helium flow through the NMR system. The pressure drop, the mass flow rate through each of the disc and window channels and the force applied on the first disc are some of the quantities estimated using CFD. These results will be combined with Monte Carlo N-Particle (MCNP) estimates of heat flux into the system from the electron beam to perform conjugate heat transfer analysis (CHT). The experiments presented in this report focus on the effect of the flow induced vibrations from helium flowing through the coolant gaps between the discs. There is concern that the flow induced vibrations may lead to excessive mass loss of the enriched Mo-100 discs, and the goal would be to mitigate the mass loss. This work presents benchtop tests of flow through a subset of the target stack which involves high speed imaging and displacement measurements used to estimate disc vibration, as well as mass loss.

42 ENGINEERING↗

Model form and sensitivity analysis of CALPHAD-based nucleation models in b-stabilized Ti alloys

Accurate prediction of α-phase nucleation and growth in β-stabilized titanium alloys is crucial for designing heat treatments to optimize mechanical properties in additively manufactured lightweight components. Ideally, predictions of nucleation and growth would incorporate both top-down observations of past experimental heat treatments and bottom-up modeling of phase transformations; however, the appropriate method of combining these information sources is not self-evident. Combining top-down and bottom-up information requires a unified form of model that can connect between spatiotemporal scales, as well as sets of fitting parameters that can be identified by each data source. The selection of which parameters to fit to which data source can be made based on expert opinion, or by performing a sensitivity analysis. In solid-solid nucleation, direct observation of the nucleation and growth process is challenging. Most data on the heat treatment-controlled phase transformations are not in-situ. To predict the process and outcome of the nucleation, growth and coarsening of precipitates, theoretical models of the nucleation pathway are used to bridge the gap. Many sources of uncertainty affect the modeling of this nucleation process. It can be influenced by small variations in the thermomechanical processing history, chemical composition, and initial microstructure. If molecular dynamics (MD) simulations are used to determine thermodynamic quantities and inform CALPHAD modeling, additional uncertainty can be introduced and accounted for using Bayesian methods. Top-down uncertainties require additional steps to quantify. The influence of nucleation model form on the sensitivity of predictions to input parameters and physical conditions is the focus of this study. Classical nucleation theory (CNT) allows modeling to formulate the nucleation as homogeneous or, more commonly, heterogeneous. Non-classical nucleation models are also increasingly explored as a means of reconciling top-down and bottom-up data. In this study, the sensitivity of the intragranular nucleation of α in a β-annealed, slow-cooled aging (BASCA) heat treatment of β-stabilized Ti5553 alloy is explored using CNT and both heterogeneous and homogeneous assumptions. The Kampmann-Wagner Numerical model of precipitate nucleation and growth is employed. Using open-source tools (pyCalphad and thermodynamic modeling of TiMo as a surrogate system, a sensitivity analysis is performed to measure variations in key parameters, including chemical driving force, interfacial energy, and diffusivity, as they relate to predictions of precipitate number density. The inclusion of top-down and bottom-up data in selection of nucleation model form is discussed.

Rodriguez Negron, A. M.↗

Searching for axion forces with spin precession in atoms and molecules

We propose to use atoms and molecules as quantum sensors of axion-mediated monopole-dipole forces. We show that electron spin precession experiments using atomic and molecular beams are well-suited for axion searches thanks to the presence of co-magnetometer states and single-shot temporal resolution. Experimental strategies to detect axion gradients from localised sources and the earth are presented, taking ACME III as a prototype example. Other possibilities including atomic beams, and laser-cooled atoms and molecules are discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lacustrine leaf wax hydrogen isotopes indicate strong regional climate feedbacks in Beringia since the last ice age

The Late-Quaternary climate of Beringia remains unresolved despite the region's role in modulating glacial-interglacial climate and as the likely conduit for human dispersal into the Americas. In this work, we investigate Beringian temperature change using an ~32,000-year lacustrine record of leaf wax hydrogen isotope ratios (δ2Hwax) from Arctic Alaska. Based on Monte Carlo iterations accounting for multiple sources of uncertainty, the reconstructed summertime temperatures were ~3 °C colder (range: –8 to +3 °C) during the Last Glacial Maximum (LGM; 21-25 ka) than the pre-industrial era (PI; 2–0.1 ka). This ice-age summer cooling is substantially smaller than in other parts of the Arctic, reflecting altered atmospheric circulation and increased continentality which weakened glacial cooling in the region. Deglacial warming was punctuated by abrupt events that are largely synchronous with events seen in Greenland ice cores that originate in the North Atlantic but which are also controlled locally, such as by the opening of the Bering Strait between 13.4 and 11 ka. Our reconstruction, together with climate modeling experiments, indicates that Beringia responds more strongly to North Atlantic freshwater forcing under modern-day, open-Bering Strait conditions than under glacial conditions. Furthermore, a 2 °C increase (Monte Carlo range: –1 to +5 °C) over the anthropogenic era reverses a 6 °C decline (Monte Carlo range: –10 to 0 °C) through the Holocene, indicating that recent warming in Arctic Alaska has not surpassed peak Holocene summer warmth.

54 ENVIRONMENTAL SCIENCES↗

Maximizing the Use of Ductless Mini-Splits in Homes with Existing Central or Zonal Heating and Cooling Equipment

In the residential retrofit application, ductless mini-split heat pumps (DHP) are often reported to hold high-energy savings potential, depending on the system they are supplementing or replacing. However, of late, there have been a number of studies and analyses indicating these energy savings are not being achieved. The primary goal of this project was to determine the most cost effective (lowest cost for the most energy saved) and persistent (e.g. automated, hard to change, etc.) solution for controlling a ductless heat pump in an existing home with central forced air furnace. Various control strategies were tested at the Pacific Northwest National Laboratory Lab Homes to compare the energy savings between the different energy efficient control strategies. A maximum of 40% energy savings was realized by using the ductless mini-split as the primary heat source with the central air conditioning unit as the secondary source.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Understanding Recent Global Hydroclimate Change Using Multivariate Detection and Attribution Techniques and GCM Experiments

The observed slowdown in the rate of global average surface temperature (T) warming during the post-1998 decade (referred to at the time as the “global warming hiatus”) posed a challenge for climate researchers because it was not captured in global climate models projection. Observational and modeling evidence hinted that that leveling of the T trend was linked with the simultaneous appearance of cold surface temperature in the eastern equatorial Pacific that formed a protracted La Niña-like state, a phenomenon known as the Inter-decadal Pacific Oscillation (IPO). It was however not clear whether the concurrent equatorial Pacific cooling was a regional response to the rise in atmospheric greenhouse gas levels or anthropogenic aerosols that is not captured by the climate models or whether it was an unrelated, serendipitous manifestation of a natural phenomenon, internal to the climate system. To resolve this issue, we proposed in this project to develop and apply fingerprinting methods to differentiate between the observed climate response to various external forcing agents and the manifestations of internal climate variability. The project also sought to find out if climate models are able to reproduce the change signals detected in key observational phenomena and if they can be used to investigate the underlying processes. As such we examined changes in global hydroclimate variability and in an outstanding example of regional hydroclimate change, namely the multi-decadal 20 th century change in Sahel rainfall.

54 ENVIRONMENTAL SCIENCES↗

Contrasting aerosol effects on longwave cloud forcing in South East Asia and Amazon simulated with Community Atmosphere Model version 5.3

Aerosols modify cloud microphysical and radiative properties and thus impact the shortwave (SW) and longwave cloud forcing (LWCF). This study first reports the finding of contrasting aerosol effects on LWCF in South East Asia and Amazon in the Community Atmosphere Model version 5.3 (CAM5.3), which corresponds to the sum of LW indirect and semi-direct effects investigated in Ghan et al., (2012). A series of numerical experiments is conducted to decompose the complex aerosol effects on LWCF. Our analysis indicates that the cooling (negative aerosol effects on LWCF) in Amazon is due mainly to the aerosol effects on warm clouds and the inhibition of vertical motion by the aerosol-induced radiative cooling. In contrast, the warming (positive aerosol effects on LWCF) in South East Asia is due mainly to the aerosol effect on homogeneous freezing, thus reducing the ice particle size and prolonging the existence of ice cloud. Our results emphasize that a comprehensive analysis of integrated aerosol effects on both warm and ice clouds is necessary for better understanding the aerosol effects on LWCF.

54 ENVIRONMENTAL SCIENCES↗