Search NASA⌕ Search

SEARCH · Search NASA

Results for “frames”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Frame Synchronization Without Attached Sync Markers

A new frame synchronizer was presented. It eliminates the need to transmit attached sync markers (ASMs). In approximately 10 iterations, the decoder can distinguish between sync and non-sync states.

Attached Sync Markers (ASMs)↗

Recent Advances in Registration, Integration and Fusion of Remotely Sensed Data: Redundant Representations and Frames

In recent years, sophisticated mathematical techniques have been successfully applied to the field of remote sensing to produce significant advances in applications such as registration, integration and fusion of remotely sensed data. Registration, integration and fusion of multiple source imagery are the most important issues when dealing with Earth Science remote sensing data where information from multiple sensors, exhibiting various resolutions, must be integrated. Issues ranging from different sensor geometries, different spectral responses, differing illumination conditions, different seasons, and various amounts of noise need to be dealt with when designing an image registration, integration or fusion method. This tutorial will first define the problems and challenges associated with these applications and then will review some mathematical techniques that have been successfully utilized to solve them. In particular, we will cover topics on geometric multiscale representations, redundant representations and fusion frames, graph operators, diffusion wavelets, as well as spatial-spectral and operator-based data fusion. All the algorithms will be illustrated using remotely sensed data, with an emphasis on current and operational instruments.

Fusion↗

The Evolution of the Galaxy Rest-Frame Ultraviolet Luminosity Function Over the First Two Billion Years

We present a robust measurement and analysis of the rest-frame ultraviolet (UV) luminosity function at z = 4 to 8. We use deep Hubble Space Telescope imaging over the CANDELS/GOODS fields, the Hubble Ultra Deep Field and the Hubble Frontier Field deep parallel observations near the Abell 2744 and MACS J0416.1- 2403 clusters. The combination of these surveys provides an effective volume of 0.6-1.2 ×10(exp 6) Mpc(exp 3) over this epoch, allowing us to perform a robust search for bright (M(sub UV) less than −21) and faint (M(sub UV) = −18) galaxies. We select galaxies using a well-tested photometric redshift technique with careful screening of contaminants, finding a sample of 7446 galaxies at 3.5 less than z less than 8.5, with more than 1000 galaxies at z of approximately 6 - 8. We measure both a stepwise luminosity function for galaxies in our redshift samples, as well as a Schechter function, using a Markov Chain Monte Carlo analysis to measure robust uncertainties. At the faint end our UV luminosity functions agree with previous studies, yet we find a higher abundance of UV-bright galaxies at z of greater than or equal to 6. Our bestfit value of the characteristic magnitude M* is consistent with −21 at z of greater than or equal to 5, different than that inferred based on previous trends at lower redshift. At z = 8, a single power-law provides an equally good fit to the UV luminosity function, while at z = 6 and 7, an exponential cutoff at the bright-end is moderately preferred. We compare our luminosity functions to semi-analytical models, and find that the lack of evolution in M* is consistent with models where the impact of dust attenuation on the bright-end of the luminosity function decreases at higher redshift, though a decreasing impact of feedback may also be possible. We measure the evolution of the cosmic star-formation rate (SFR) density by integrating our observed luminosity functions to M(sub UV) = −17, correcting for dust attenuation, and find that the SFR density declines proportionally to (1 + z)((exp −4.3)(+/-)(0.5)) at z greater than 4, consistent with observations at z greater than or equal to 9. Our observed luminosity functions are consistent with a reionization history that starts at redshift of approximately greater than 10, completes at z greater than 6, and reaches a midpoint (x(sub HII) = 0.5) at 6.7 less than z less than 9.4. Finally, using a constant cumulative number density selection and an empirically derived rising star-formation history, our observations predict that the abundance of bright z = 9 galaxies is likely higher than previous constraints, though consistent with recent estimates of bright z similar to 10 galaxies.

Galaxy↗

Comparison of Realizations of the Terrestrial Reference Frame

IGN and DGFI both generated realizations of the terrestrial reference frame under the auspices of the IERS from combination of the same space geodetic data. We compared the IGN and DGFI TRFs with a GSFC CALC/SOLVE TRF. WRMS position and velocity differences for the 40 most frequently observed sites were 2-3 mm and 0.3-0.4 mm/year. There was a scale difference of 0.39/0.09 ppb between the IGN/DGFI realizations and the GSFC solution. When we fixed positions and velocities to either the IGN or DGFI values in CALC/SOLVE solutions, the resulting EOP estimates were not significantly different from the estimates from a standard TRF solution.

Comparison↗

SPC-3186 Rev 8 Reactor Support Frame and Outer Shield Build to Print Fabrication Specification

Idaho National Laboratory (INL) is developing a microreactor to produce electrical power utilizing a small nuclear core under the Microreactor Application Research Validation and Evaluation (MARVEL) program. This procurement specification defines the requirements for fabrication of the Reactor Support Frame (RSF) and Outer Shield.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

A 28 nm multiply-accumulate ASIC architecture for on-chip data compression in MHz frame rate X-ray and electron pixel detectors

Modern X-ray detector systems urgently require compact, efficient, and fast data compression schemes to handle the transmission of big data from pixel arrays, enabling frame rates in the MHz regime. Here, in this work, a data compression ASIC that implements a streaming fixed-length lossy compression scheme is introduced and analyzed, proving the feasibility and benefits of on-chip compression. The compression scheme utilizes a vector matrix product logic, which performs a number of floating-point multiplications, additions, and accumulations. The logic is verified, synthesized, and shown to fit in the area resource available for the X-ray detector under study, which comprises 192 × 168 pixels each of 12-bit width, and having a total area of 20 mm× 20 mm, about 2 mm× 20 mm of which are available for the digital logic. Several system architectures, precisions, and compression ratios ranging from 100 to 250 were analyzed to pave the way for on-chip fixed-length compression (e.g., principal component analysis, singular value decomposition) and data reduction (e.g., azimuthal integration) for X-ray and electron detectors.

Data compression↗

First results from a high-frame-rate, multi-GHz ionizing particle detection system geared toward accelerator diagnostic applications

An integrated detection system, consists of a thin diamond sensor incorporated into a compact signal loop, coupled in turn to an application-specific integrated circuit readout chip, has been tested for the first time, using ps-duration electron pulses from the Next Linear Collider Test Accelerator at the SLAC National Accelerator Laboratory. For readout frame rates as high as 120 kHz, the detection system is shown to achieve a linear dynamic range of 10 3 and a bandwidth of 4–5 GHz, with no ringing seen on the tail of the output pulse. These results represent the best-performing multi-GHz ionizing particle detection system achieved to date.

Ferezghi, Mohammadreza Mohseni [University of Cali↗

Attosecond time delays in the body frame for photodetachment from molecular anions

Attosecond time delays in molecular photoionization at low energies are dominated by the contribution of the Coulomb phase, which diverges as the energy of the photoelectron decreases towards zero. With calculations on core-electron ejection from CN – and C 2 – we demonstrate that in photodetachment of molecular anions the absence of the long-range Coulomb interaction in the final state can reveal the delays of narrow low-energy shape resonances that do not generally occur in photoionization. Delays of several femtoseconds can be associated with such resonances. Finally, the angular dependence of photodetachment time delays in the body frame is highly sensitive to short-range anisotropies in the electron-molecule interaction as well as to the initial state.

74 ATOMIC AND MOLECULAR PHYSICS↗

Native frames: An approach for separating sequential and concerted three-body fragmentation

Disentangling sequential and concerted three-body fragmentation has been a longstanding endeavor in studies of molecular dynamics. To accomplish this goal, we recently introduced a novel method to separate sequential from concerted breakup, where the sequential events are analyzed in their native frames [J. Rajput et al., Phys. Rev. Lett. 120, 103001 (2018)]. The essence of this method is the use of the Jacobi coordinates' conjugate momenta to reduce the dimensionality of the multibody fragmentation in combination with a clear signature for sequential breakup. To demonstrate this method, we employ coincidence momentum imaging to study the strong-field dissociative ionization of OCS into O + +C + + S + , which typically undergoes concerted fragmentation or sequential breakup involving either a metastable CO 2+ or CS 2+ molecule. We identify sequential breakup using a uniform distribution as a function of the angle between the conjugate momenta, associated with the first and second fragmentation steps, which is due to the rotation of the intermediate molecule in the fragmentation plane. Furthermore, by exploiting this uniform distribution, we separate the sequential and concerted distributions in any plot created from the measured momenta.

Atomic & molecular processes in external fields↗

Nonlocal nucleon matrix elements in the rest frame

Extracting parton structure from lattice quantum chromodynamics (QCD) calculations requires studying the coordinate scale 𝑧 3 dependence of the matrix elements of bilocal operators. The most significant contribution comes from the 𝑧 3 dependence induced by ultraviolet (UV) renormalization of the Wilson line. We demonstrate that the next-to-leading order perturbative calculations of the renormalization factor can describe, to a few percent accuracy, the logarithm of the lattice QCD rest frame matrix elements with separations up to distances of 0.6 fm on multiple lattice spacings. The residual discrepancies can be modeled by a leading effect from the structure of the nucleon.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CFD Modeling of High-Flux Plate-and-Frame Membrane modules for industrial carbon capture

In this work, we explore the use of CO2-selective flat sheet membranes for capturing CO2 from point sources. We employ Computational Fluid Dynamics (CFD) models to design high-flux plate-and-frame membrane modules to achieve uniform flow distribution among membrane elements, minimize dead-end zones, and ease the common concentration polarization issue for gas separation membranes. The goal is to drive membrane technology improvements by providing better module designs for given membrane properties and operating conditions.

Dosso, Cheick↗

Calculation of Velocities from Explosive Shot Test Fast-Frame Imagery

A cylinder of the experimental HE is detonated inside of an aquarium and sequential fast-frame images are taken of the resulting shock wave. We wish to use the sequence of images to extract quantitative data regarding the detonation velocity and velocity of the shock wave which can then be used to tune the parameters of the equation of state for the experimental HE material.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

CFD Modeling of High-Flux Plate-and-Frame Membrane Modules for Industrial Carbon Capture

In this work, we explore the use of CO2-selective flat sheet membranes for capturing CO2 from point sources. We employ Computational Fluid Dynamics (CFD) models to design high-flux plate-and-frame membrane modules to achieve uniform flow distribution among membrane elements, minimize dead-end zones, and ease the common concentration polarization issue for gas separation membranes. The goal is to drive membrane technology improvements by providing better module designs for given membrane properties and operating conditions.

Dosso, Cheick↗

Mounted Accelerometer Frequency Response of Adhesive Products and Aluminum Frame Quick Mounts

An accelerometer mounting technique has large implications on the frequency range and accuracy of the measurement, with stiffness and the mass relative to the monitored structure as the primary concerns. The International Organization for Standardization (ISO) gives an extensive list in 5348:2021, detailing mounting methods, and provides recommendations for testing mounts that are not specifically defined. In the nuclear industry on the laboratory scale, there is a need for vibration measurements for predictive maintenance and process monitoring that are nondestructive and capable of working in high-temperature environments. Commercial adhesive products with easy application and removal were tested as nondestructive methods, while quick mounts to a commonly used aluminum frame were tested as nondestructive and have potential applicability in high-temperature environments. The sinusoidal excitation method was used, measuring frequencies from 50 Hz to 10 kHz in one-third octave band intervals, utilizing three accelerometers and comparing the results to those obtained with the stud-mounting method. Using the lowest ±3 dB threshold across each accelerometer, foam dots and poster strips were not successful, and foam tapes were accurate up to 2000 Hz, hose clamps and zip ties up to 800 Hz, and a custom 3D printed mount up to 1000 Hz. Knowing the limitations of each mounting technique allows for accurate measurements within the appropriate range.

47 - OTHER INSTRUMENTATION↗