Development of a 1200-hertz alternator and controls for space power systems
Design and testing of 1200-Hz alternator and voltage and frequency controls for Brayton space power systems
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Design and testing of 1200-Hz alternator and voltage and frequency controls for Brayton space power systems
The first-year progress for the project of precise measurements of the density and critical phenomena of helium near phase transitions is summarized below: (1) completion of a cryogenic sample probe for the proposed measurements, and the rehabilitation of a designated laboratory at Caltech for this project; (2) construction and testing of a superconducting niobium cavity; (3) acquisition of one phase-locked-loop system for high-resolution frequency control and read- out; (4) setting up high-resolution thermometry (HRT) for temperature readout and control; (5) developing new approaches for calibrating the coefficient between the resonant frequency shift (delta f) and the helium density (rho), as well as for measuring the effect of gravity on T(sub lambda) to a much better precision; (6) programming of the interface control of all instruments for automatic data acquisition; and (7) improving data analyses and fitting procedures.
The multiaxis control problem is addressed within the context of the optimal pilot model. The problem is developed to provide efficient adaptation of the optimal pilot model to complex aircraft systems and real world, multiaxis tasks. This is accomplished by establishing separability of the longitudinal and lateral control problems subject to the constraints of multiaxis attention and control allocation. Control solution adaptation to the constrained single axis attention allocations is provided by an optimal control frequency response algorithm. An algorithm is developed to solve the multiaxis control problem. The algorithm is then applied to an attitude hold task for a bare airframe fighter aircraft case with interesting multiaxis properties.
Quasi-optical oscillators were proposed a little more than ten years ago as a means of developing the power levels needed for applications at millimeter frequencies using large numbers of individual semiconductor devices each of which produces only a modest amount of power [J.W. Mink, IEEE Trans. MTT., vol. 34, p. 273, 19861. An operating system was demonstrated soon after [Z.B. Popovic et. al, Int. J. Infrared and Millimeter Waves, v. 9, p. 647, 1988] in the form of a so-called grid oscillator. This device constituted a rectangular array of oscillating devices that are mutually coupled so that they oscillator coherently. The interconnecting lines in one direction serve as radiators so that the oscillators radiate directly, and the radiated fields add. Subsequently, coupled oscillators using resonant transmission line lengths was demonstrated by Mortazawi and Itoh [IEEE Trans. MTT., vol. 38, p. 86,1990). In recent work, coupled-oscillator power combiners have received less attention, with amplifier/combiners receiving more attention. Specific weaknesses of spatial-combining oscillators have motivated this transition. Namely, the oscillators employ low-Q resonators (resulting in low signal quality) and no clear means of modulation has been identified until recently. In this presentation, we review coupled-oscillator combiners in broad terms, indicating the features that make particular systems viable. We indicate how these features can be reconciled to functional requirements for system applications. Comparisons are drawn between two approaches to obtain mutual coupling: One employs low-Q oscillator circuits at each site, with concomitantly high propensity for the oscillators to couple. The other approach employs moderate-Q oscillators at each site with the concomitant requirement to tune the oscillators so that they share a range of frequencies over which they can couple and lock. In either case, precise frequency control and modulation can be achieved through locking to an external frequency source that ensures high quality signals. A recent development in coupled-oscillator arrays provides a means for beam-steering the radiation field of coupled oscillators through de-tuning of the edge elements in the array. This detuning introduces a progressive phase shift across the oscillator array. This 0 suggests architectures that can replace the functionality of a phased array without the cost 0 incurred by phase shifters. A comprehensive theory of the phase interactions among devices in such arrays is under development [e.g., Pogorzelski, York, and Maccarini, 1998 AP-S International Symposium, Atlanta, GA. June, 19981.
The research and development under this project was focused on the following three major objectives: Objective 1: Identification of critical in-vessel SMR components for remote monitoring and development of their low-order dynamic models, along with a simulation model of an integral pressurized water reactor (iPWR). Objective 2: Development of an experimental flow control loop with motor-driven valves and pumps, incorporating data acquisition and on-line monitoring interface. Objective 3: Development of stationary and transient signal processing methods for electrical signatures, machinery vibration, and for characterizing process variables for equipment monitoring. This objective includes the development of a data analysis toolbox. The following is a summary of the technical accomplishments under this project: - A detailed literature review of various SMR types and electrical signature analysis of motor-driven systems was completed. A bibliography of literature is provided at the end of this report. Assistance was provided by ORNL in identifying some key references. - A review of literature on pump-motor modeling and digital signal processing methods was performed. - An existing flow control loop was upgraded with new instrumentation, data acquisition hardware and software. The upgrading of the experimental loop included the installation of a new submersible pump driven by a three-phase induction motor. All the sensors were calibrated before full-scale experimental runs were performed. - MATLAB-Simulink model of a three-phase induction motor and pump system was completed. The model was used to simulate normal operation and fault conditions in the motor-pump system, and to identify changes in the electrical signatures. - A simulation model of an integral PWR (iPWR) was updated and the MATLAB-Simulink model was validated for known transients. The pump-motor model was interfaced with the iPWR model for testing the impact of primary flow perturbations (upsets) on plant parameters and the pump electrical signatures. Additionally, the reactor simulation is being used to generate normal operation data and data with instrumentation faults and process anomalies. A frequency controller was interfaced with the motor power supply in order to vary the electrical supply frequency. The experimental flow control loop was used to generate operational data under varying motor performance characteristics. Coolant leakage events were simulated by varying the bypass loop flow rate. The accuracy of motor power calculation was improved by incorporating the power factor, computed from motor current and voltage in each phase of the induction motor.- A variety of experimental runs were made for steady-state and transient pump operating conditions. Process, vibration, and electrical signatures were measured using a submersible pump with variable supply frequency. High correlation was seen between motor current and pump discharge pressure signal; similar high correlation was exhibited between pump motor power and flow rate. Wide-band analysis indicated high coherence (in the frequency domain) between motor current and vibration signals. - Wide-band operational data from a PWR were acquired from AMS Corporation and used to develop time-series models, and to estimate signal spectrum and sensor time constant. All the data were from different pressure transmitters in the system, including primary and secondary loops. These signals were pre-processed using the wavelet transform for filtering both low-frequency and high-frequency bands. This technique of signal pre-processing provides minimum distortion of the data, and results in a more optimal estimation of time constants of plant sensors using time-series modeling techniques.
Tetrode-driven transistor crystal oscillator with frequency controlled by variation of second base current of tetrode operating in reverse mode
The operation of a 5-msec, quasi-continuous wave (CW) 10-Hz repetition-rate pulsed single-frequency Nd:YAG oscillator with a feedback stabilized frequency bandwidth of less than 200 kHz is described. The major problems associated with frequency stabilization for quasi-CW operation, frequency chirp and maintenance of the frequency control signal, are described, and the design of a wide-bandwidth frequency locking system with a search and chirp compensation loop is given. This frequency stabilized oscillator is a potentially useful laser source for atmospheric wind velocity measurements by coherent lidar Doppler velocimetry, which require a laser source with less than 1 MHz linewidth, and also has applications in high-resolution nonlinear spectroscopic studies at Fourier-transform-limited linewidths.
Optimum performance of large space antennas requires very fine control of the shape of the antenna surface since the shape affects both frequency control and pointing accuracy. A significant factor affecting the antenna shape is the temperature of the structure and the resulting deformation. To accurately predict the temperature of the structure, it is necessary first to accurately predict thermal loads. As the structure orbits the Earth, the thermal loads change constantly so that the thermal-structural response varies continuously throughout the orbit. The results from recent applications of integrated finite element methodology to heat load determination and thermal-structural analysis of large space structures are given. Four areas are concentrated on: (1) the characteristics of the integrated finite element methodology, (2) fundamentals of orbital heat load calculation, (3) description and comparison of some radiation finite elements, and (4) application of the integrated finite-element approach to the thermal-structural analysis of an orbiting truss structure.
Cavity-modulation tuning system maintains resonance of hydrogen-maser cavity automatically, stabilizing maser frequency, without introducing undesirable frequency modulation. System tunes maser cavity rapidly by modulating one of physical characteristics of cavity affecting resonant frequency. Frequency-controlling components of tuning system placed at maser cavity, within maser vacuum. Thermal environment well controlled, and device insensitive to driving signal. Features contribute to stability of maser frequency.
Active control of high-frequency (greater than 500 Hz) combustion instability has been demonstrated in the NASA single-nozzle combustor rig at United Technologies Research Center. The combustor rig emulates an actual engine instability and has many of the complexities of a real engine combustor (i.e. actual fuel nozzle and swirler, dilution cooling, etc.) In order to demonstrate control, a high-frequency fuel valve capable of modulating the fuel flow at up to 1kHz was developed. Characterization of the fuel delivery system was accomplished in a custom dynamic flow rig developed for that purpose. Two instability control methods, one model-based and one based on adaptive phase-shifting, were developed and evaluated against reduced order models and a Sectored-1-dimensional model of the combustor rig. Open-loop fuel modulation testing in the rig demonstrated sufficient fuel modulation authority to proceed with closed-loop testing. During closed-loop testing, both control methods were able to identify the instability from the background noise and were shown to reduce the pressure oscillations at the instability frequency by 30%. This is the first known successful demonstration of high-frequency combustion instability suppression in a realistic aero-engine environment. Future plans are to carry these technologies forward to demonstration on an advanced low-emission combustor.
Buildings are responsible for more than 73% of the total electricity use in the United States and one-third of the building electricity use is attributed to heating, ventilation and air-conditioning (HVAC) systems. If properly used, buildings could offer significant frequency control reserves to the power grid. This paper presents laboratory test results demonstrating the potential to use variable-speed packaged rooftop units for frequency regulation services. The test unit along with the proposed feedback control represents an add-on solution that requires minimum control upgrades to enable the provision of ancillary services. Test results show that HVAC systems can provide high-quality frequency regulation services with performance scores of up to 0.95. A first-order economic analysis also reveals significant economic benefits for building owners to participate in ancillary services.
Rapid recovery of power flow, possibly after a blackout, is a crucial need arising in scenarios that are increasingly becoming more frequent; here, solutions for rapid viability of power while the grid is being restored are urgently needed to keep critical infrastructure (CI) online. Increasingly, after the initial recovery phase, sustenance of reliable power requires assistive services to the grid for long periods of time. Even though the need is urgent, there is only sparse effort present toward a comprehensive framework/strategy for making power rapidly viable with an emphasis on sustained grid ancillary services; which is the focus of this proposal. The proposed concept envisions four phases. In the first phase, when a large portion of power is disrupted (see Figure 1(a)), emphasis is on bringing CI online with the objective of maximizing the time horizon of power viability using resources available at the CI. In the second phase (Figure 1(b)), neighborhood resources are tightly coordinated that forms the CI’s central-core (CC) to provide guaranteed viability of CI over a longer horizon. In the third phase, self-organizing power networks are expanded in a distributed layer supporting the central-core (Figure 1(c)). In the fourth phase, separate CI-networks coalesce and are controlled in a coordinated fashion to provide grid ancillary services (AS), such as primary frequency control and enhancing grid resiliency. With time, system efficiencies and penetration of renewables increase, while the time-horizon of guaranteed sustenance of CI is maximized. Under proposed work, the concept will be instantiated with a focus on medical centers as CI. Comprehensive power hardware in the loop strategies and emulated field tests will guide and validate devised solutions. A strong T2M effort to commercialize resulting technology is outlined. The proposed technology will be transformative for the grid. It will fundamentally change the way large contingencies are managed where power systems and critical infrastructure transition from being fragile to being robust using intelligent, self-organizing control for coordinating resources, enhanced resiliency and use of sustainable energy sources.
Explore the source record for details and available documents.
We report that the gyrotropic properties of a rotating magnetized plasma are derived analytically. Mechanical rotation leads to a new cutoff for wave propagation along the magnetic field, and polarization rotation above this cutoff is the sum of the classical magneto-optical Faraday effect and the mechanico-optical polarization drag. Exploiting the very large effective group index near the cutoff, we expose here that polarization drag can be 10 4 larger than Faraday rotation at GHz frequency. The rotation leads to weak absorption while allowing direct frequency control, demonstrating the unique potential of rotating plasmas for nonreciprocal elements. The very large rotation frequency of a dense non-neutral plasma could enable unprecedented gyrotropy in the THz regime.
An object of this invention is to provide robust nonlinear controllers for robotic operations in unstructured environments based upon a new class of closed loop sliding control methods, sometimes denoted terminal sliders, where the new class will enforce closed-loop control convergence to equilibrium in finite time. Improved performance results from the elimination of high frequency control switching previously employed for robustness to parametric uncertainties. Improved performance also results from the dependence of terminal slider stability upon the rate of change of uncertainties over the sliding surface rather than the magnitude of the uncertainty itself for robust control. Terminal sliding mode control also yields improved convergence where convergence time is finite and is to be controlled. A further object is to apply terminal sliders to robot manipulator control and benchmark performance with the traditional computed torque control method and provide for design of control parameters.
Frequency control from the demand side presents a novel and viable way to complement control by traditional generators. This paper presents simulation tests of a previously developed load controller in a large interconnected system model. The controller was implemented as a user defined model in PowerWorld software. WECC system model was used. The simulation tests include comparison of situation with and without control, sensitivities to controller location, control gain parameters, and type of end-use loads. The performance is measured in terms of frequency and intertie power flow deviations after a large generator outage.
The project examined next-generation power distribution systems with high levels of power- electronics-interfaced distributed energy resources (DERs) that include: renewable energy systems (RESs), energy-storage devices, electric vehicles, fuel cells, small-scale diesel generators, and controllable loads. The project developed a comprehensive distribution- network management framework that unifies real-time voltage and frequency control with network-wide energy management under an integrated framework. The aim of the project was to: i) systematically optimize network-wide operation and congruently regulate voltages and frequency in the face of high volatility induced by rapidly varying RES and uncontrolled loads; ii) facilitate high renewable integration beyond 50% on an energy basis; iii) meet power-quality requirements and operational constraints; and, iv) respect response, ramp- time, and hold-time requirements for synthetic frequency and regulating reserves via fast- and longer-term dynamic energy management.
Experimental results of terminal shock and restart control system tests of a two-dimensional, twin-duct mixed compression inlet are presented. High-response (110-Hz bandwidth) overboard bypass doors were used, both as the variable to control shock position and as the means of disturbing the inlet airflow. An inherent instability in inlet shock position resulted in noisy feedback signals and thus restricted the terminal shock position control performance that was achieved. Proportional-plus-integral type controllers using either throat exit static pressure or shock position sensor feedback gave adequate low-frequency control. The inlet restart control system kept the terminal shock control loop closed throughout the unstart-restart transient. The capability to restart the inlet was non limited by the inlet instability.