Search NASA⌕ Search

SEARCH · Search NASA

Results for “full scale testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Development of Energy Absorbing Subfloor Concepts to Improve Crashworthiness of eVTOL Aircraft

To help ensure safe transportation within electric Vertical Take-off and Landing (eVTOL) vehicles the National Aeronautics and Space Administration (NASA) has been developing novel energy absorbing (EA) design technologies to improve crashworthiness within the unique design constraints of these vehicles. As part of this effort, a series of lightweight energy absorbing subfloor concepts were developed for potential use within eVTOL vehicle design. The capability of the subfloor designs was first evaluated through finite element (FE) model simulation in both component and vehicle level impact conditions. Knowledge gained from these analyses were used to iterate upon the design prior to fabrication. Fabrication and testing of the subfloor designs has begun and will be used to verify predicted capability. Results from FE model analysis was used to down select to a final subfloor geometry for additional component level optimization and full-scale test validation.

Crashworthiness↗

Design, fabrication, and test of a full-scale graphite/epoxy metering truss for the space telescope

This paper presents the work performed in a program sponsored by MSFC-NASA in which a full-scale graphite/epoxy metering truss was designed, fabricated and tested. The primary requirement was to provide a structure that was dimensionally stable in a transient temperature environment. Structural element characterization requiring measurements in the microstrain region are described along with resulting strength, stiffness and coefficient of thermal expansion data. The full-scale tests included static, dynamic and thermal-vacuum dimensional stability evaluations.

Oken, S.↗

Thrust performance of a variable-geometry, divergent exhaust nozzle on a turbojet engine at altitude

A variable geometry, low aspect ratio, nonaxisymmetric, two dimensional, convergent-divergent exhaust nozzle was tested at simulated altitude on a turbojet engine to obtain baseline axial, dry thrust performance over wide ranges of operating nozzle pressure ratios, throat areas, and internal expansion area ratios. The thrust data showed good agreement with theory and scale model test results after the data were corrected for seal leakage and coolant losses. Wall static pressure profile data were also obtained and compared with one dimensional theory and scale model data. The pressure data indicate greater three dimensional flow effects in the full scale tests than with models. The leakage and coolant penalties were substantial, and the method to determine them is included.

Straight, D. M.↗

Full-scale crash-test evaluation of two load-limiting subfloors for general aviation airframes

Three six place, low wing, twin engine general aviation airplane test specimens were crash tested at the Langley Impact Dynamics Research Facility under controlled free flight conditions. One structurally unmodified airplane was the base line specimen for the test series. The other two airplanes were structurally modified to incorporate load limiting (energy absorbing) subfloor concepts into the structure for full scale crash test evaluation and for comparison with the unmodified airplane test results. Typically, the lowest floor accelerations, the lowest anthropomorphic dummy responses, and the least seat crushing of standard and load limiting seats occurred in the airplanes modified with load limiting subfloors, wherein the greatest structural crushing of the subfloor took place. The better performing of the two load limiting subfloor concepts reduced the peak airplane floor accelerations to -25g to -30g as compared with approximately -40g to -55g for the unmodified airplane structure.

Carden, H. D.↗

Method of curved models and its application to the study of curvilinear flight of airships. Part I

In the first part of this paper we shall present the theoretical side of the problem of constructing curved model forms and the method of testing the model. In the second part we shall present a detailed account of the first experiments according to the given method, carried out with a curved model of the nonrigid airship V-2, and a comparison of the experimental results with some data of full-scale tests made with this airship in 1933.

Gourjienko, G A↗

Using Numerical Modeling to Simulate Space Capsule Ground Landings

Experimental work is being conducted at the National Aeronautics and Space Administration s (NASA) Langley Research Center (LaRC) to investigate ground landing capabilities of the Orion crew exploration vehicle (CEV). The Orion capsule is NASA s replacement for the Space Shuttle. The Orion capsule will service the International Space Station and be used for future space missions to the Moon and to Mars. To evaluate the feasibility of Orion ground landings, a series of capsule impact tests are being performed at the NASA Langley Landing and Impact Research Facility (LandIR). The experimental results derived at LandIR provide means to validate and calibrate nonlinear dynamic finite element models, which are also being developed during this study. Because of the high cost and time involvement intrinsic to full-scale testing, numerical simulations are favored over experimental work. Subsequent to a numerical model validated by actual test responses, impact simulations will be conducted to study multiple impact scenarios not practical to test. Twenty-one swing tests using the LandIR gantry were conducted during the June 07 through October 07 time period to evaluate the Orion s impact response. Results for two capsule initial pitch angles, 0deg and -15deg , along with their computer simulations using LS-DYNA are presented in this article. A soil-vehicle friction coefficient of 0.45 was determined by comparing the test stopping distance with computer simulations. In addition, soil modeling accuracy is presented by comparing vertical penetrometer impact tests with computer simulations for the soil model used during the swing tests.

Heymsfield, Ernie↗

Performance and loads data from a hover test of a full-scale advanced technology XV-15 rotor

A hover test of a full-scale, composite, advanced technology XV-15 rotor was conducted at the Outdoor Aerodynamic Research Facility at Ames Research Center. The primary objective of the test was to obtain accurate measurements of the hover performance of this rotor system. Data were acquired for rotor tip Mach numbers ranging from 0.35 to 0.73. The rotor was tested with several alternate blade root and blade-tip configurations. Data are presented on rotor performance, rotor-wake downwash velocities, and rotor system loads.

Felker, Fort F.↗

LEAPTech/HEIST Experiment Test and Evaluation Summary

The Leading Edge Asynchronous Propeller Technology (LEAPTech) project tested the Hybrid-Electric Integrated Systems Testbed (HEIST) and was intended for a general aviation sized aircraft with Distributed Electric Propulsion (DEP) to show large improvements with regards to efficiency, emissions, safety and operating costs. The wing was designed for high loading to improve ride quality and show improved takeoff and landing characteristics. The full-scale test article wing had a 31-foot-span, had integrated electric motors, was mounted on a truck 20 ft. above ground and driven in a simulated flight test environment at various velocities up to 70 miles per hour. The simulated flight test varied primarily angle of attack and flap settings. These tests were conducted to obtain data and verify blown wing performance primarily with regards to lift. The experimental test results are presented.

electric propulsion↗

1- by 1-Foot Supersonic Wind Tunnel Sidewall Flowfield Compression Plate Study

A method for locally increasing the dynamic pressure in the test section of a supersonic wind tunnel is investigated from a theoretical, computational and experimental perspective, culminating in a reduced-scale, proof-of-concept test at Mach 3.44. Symmetric, variable-angle compression plates along the test section sidewalls generate oblique shockwaves to elevate the test section dynamic pressure (q). The experimental effort utilizes boundary-layer pitot rakes to sample the incoming flow near the floor, pitot and static rakes to measure the high-q core flow and numerous surface taps to map out the static pressure distribution along the floor, ceiling and sidewalls. A reliable and robust starting procedure is developed to establish supersonic flow in the test section and behind the compression plates. A characterization of the incoming floor boundary layer reveals previously documented features (such as a bulge toward the centerline) and an unexpected (and as-yet-unexplained) thickening of the boundary layer with increasing Reynolds number around total pressures of 40–60 psia. The high-q core flow is characterized for eight compression plate angles (4.0–8.0°), eight tunnel total pressures (20–139 psia) and three axial stations (24.95–27.35 inches). The peak dynamic pressure rise exceeds expectations. At conditions relevant to full-scale testing (6.0° and 139 psia), the dynamic pressure increases by a factor of 1.73, the Mach number becomes 2.85 and the total pressure drops imperceptibly. Basic distortion metrics show transverse non-uniformity of less than 5 %. Limited spatial resolution in the static rake measurements warrants additional, higher fidelity testing or computational analysis. Surface-mounted, fast-response instrumentation suggests minimal unsteadiness in the flow, less than a few percent of the mean (comparable to the sensor accuracy).

Wind tunnel testing, test techniques/methods, dyna↗

DC-10 composite vertical stabilizer ground test program

A review of the structural configuration and ground test program is presented. Particular emphasis is placed on the testing of a full-scale stub box test subcomponent and full span ground test unit. The stub box subcomponent was tested in an environmental chamber under ambient, cold/wet, and hot/wet conditions. The test program included design limit static loads, fatigue spectrum loading to approximately two service lifetimes (with and without damage), design limit damage tolerance tests, and a final residual strength test to a structural failure. The first full-scale ground test unit was tested under ambient conditions. The test unit was to have undergone static, fatigue, and damage tolerance tests but a premature structural failure occurred at design limit load during the third limit load test. A failure theory was developed which explains the similarity in types of failure and the large load discrepancy at failure between the two test articles. The theory attributes both failures to high stress concentrations at the edge of the lower rear spar access opening. A second full-scale ground test unit has been modified to incorporate the various changes resulting from the premature failure. The article has been assembled and is active in the test program.

Palmer, J. M., Jr.↗

Cumulative Measurement Errors for Dynamic Testing of Space Flight Hardware

Located at the NASA Johnson Space Center in Houston, TX, the Six-Degree-of-Freedom Dynamic Test System (SDTS) is a real-time, six degree-of-freedom, short range motion base simulator originally designed to simulate the relative dynamics of two bodies in space mating together (i.e., docking or berthing). The SDTS has the capability to test full scale docking and berthing systems utilizing a two body dynamic docking simulation for docking operations and a Space Station Remote Manipulator System (SSRMS) simulation for berthing operations. The SDTS can also be used for nonmating applications such as sensors and instruments evaluations requiring proximity or short range motion operations. The motion base is a hydraulic powered Stewart platform, capable of supporting a 3,500 lb payload with a positional accuracy of 0.03 inches. The SDTS is currently being used for the NASA Docking System testing and has been also used by other government agencies. The SDTS is also under consideration for use by commercial companies. Examples of tests include the verification of on-orbit robotic inspection systems, space vehicle assembly procedures and docking/berthing systems. The facility integrates a dynamic simulation of on-orbit spacecraft mating or de-mating using flight-like mechanical interface hardware. A force moment sensor is used for input during the contact phase, thus simulating the contact dynamics. While the verification of flight hardware presents unique challenges, one particular area of interest involves the use of external measurement systems to ensure accurate feedback of dynamic contact. The measurement systems for the test facility have two separate functions. The first is to take static measurements of facility and test hardware to determine both the static and moving frames used in the simulation and control system. The test hardware must be measured after each configuration change to determine both sets of reference frames. The second function is to take dynamic measurements during hardware motion and contact. While performing dynamic testing of an active docking system, researchers found that the data from the motion platform, test hardware and two external measurement systems exhibited frame offsets and rotational errors. While the errors were relatively small when considering the motion scale overall, they substantially exceeded the individual accuracies for each component. After evaluating both the static and dynamic measurements, researchers found that the static measurements introduced significantly more error into the system than the dynamic measurements even though, in theory, the static measurement errors should be smaller than the dynamic. In several cases, the magnitude of the errors varied widely for the static measurements. Upon further investigation, researchers found the larger errors to be a consequence of hardware alignment issues, frame location and measurement technique whereas the smaller errors were dependent on the number of measurement points. This paper details and quantifies the individual and cumulative errors of the docking system and describes methods for reducing the overall measurement error. The overall quality of the dynamic docking tests for flight hardware verification was improved by implementing these error reductions.

Winnitoy, Susan↗

Beryllium heat shield technology in the area of thermal protection devices

For future space applications, it is important that thermal protection systems be reusable for space shuttle flights. Beryllium offers a unique combination of properties for use as a heat shield material (stiffness, lightweight, ability to absorb heat). In order to adequately test these properties, it was necessary to fabricate heat shields. The concept used was a two-section test panel 99.1 x 99.1 cm (39 x 39 inch) with each section made of two 0.051 cm (0.020 inch) thick beryllium corrugations brazed together as a mirror image, with titanium (Ti-6Al-4V) used as standoffs to support the panel structure. The work prior to fabrication included brazability of both beryllium and titanium, forming of beryllium and titanium, machining processes involving beryllium and chem-milling beryllium. Sub-scale samples were made of all details before actual fabrication of the large panel. The full scale test panel was hot-formed at 950 K, chem-milled to 0.041 + or - 0.005 cm (0.016 + or - 0.002 inches), trimmed, vacuum brazed, drilled and assembled.

Muhl, A. E.↗

Design, development, and test of Shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems (TPS) for the Shuttle/Centaur were designed to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort, where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid-hydrogen (LH2) tank and radiation shields only for the liquid-oxygen (LO2) tank. A double-walled vacuum bulkhead separated the two tanks. The LH2 tank had one 1.9 cm-thick layer of foam on the forward bulkhead and two layers on the larger-area sidewall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay gave total prelaunch heating rates of 29.5 and 12.9 kW for the LH2 and LO2 tanks, respectively. Calorimeter tests on a representative sample of the LH2 tank sidewall TPS indicated that the measured unit heating one would rapidly decrease from the prelaunch rate of about 300 W/sq m to a desired rate less than 4 W/sq m once on-orbit.

Macneil, Peter N.↗

Wind-tunnel investigation of the heat transfer to the X-15 airplane

Paper describes the wind tunnel test program which has provided a picture of the general distribution of heat transfer coefficients over the X-15 airplane. The tunnel tests have emphasized the importance of the interactions of the flow fields of components and have shown that in some cases, where the local flow direction and total pressure can be reasonably closely inferred, use of experimental pressures to compute flow conditions yields very good predictions of heat transfer rate. There are still some regions of the airplane for which the heat transfer could not be adequately studied because of the size or construction of the model. Such local regions will not necessarily limit the operation of the airplane but will require evaluation in the full-scale tests. (author)

Feller, William V↗

Design, development and test of shuttle/Centaur G-prime cryogenic tankage thermal protection systems

The thermal protection systems for the shuttle/Centaur would have had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort. The thermal protection systems selected used a helium-purged polyimide foam beneath three rediation shields for the liquid-hydrogen tank and radiation shields only for the liquid-oxygen tank (three shields on the tank sidewall and four on the aft bulkhead). A double-walled vacuum bulkhead separated the two tanks. The liquid-hydrogen tank had one 0.75-in-thick layer of foam on the forward bulkhead and two layers on the larger area sidewall. Full scale tests of the flight vehicle in a simulated shuttle cargo bay that was purged with gaseous nitrogen gave total prelaunch heating rates of 88,500 Btu/hr and 44,000 Btu/hr for the liquid-hydrogen and -oxygen tanks, respectively. Calorimeter tests on a representative sample of the liquid-hydrogen tank sidewall thermal protection system indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of approx 100 Btu/hr/sq ft to a desired rate of less than 1.3 Btu/hr/sq ft once on orbit.

Knoll, Richard H.↗

Development and test of the Shuttle/Centaur cryogenic tankage thermal protection system

The Thermal Protection System (TPS) for the Shuttle/Centaur had to provide fail-safe thermal protection during prelaunch, launch ascent, and on-orbit operations as well as during potential abort where the Shuttle and Centaur would return to earth. The TPS selected used a helium-purged polyimide foam beneath three radiation shields for the liquid hydrogen (LH2) tank and radiation shields only for the liquid oxygen (LO2) tank (three shields on the tank sidewall and four on the aft bulkhead). An evacuated common intermediate bulkhead separated the two tanks. The LH2 tank had one 1.9-cm thick layer of foam on the forward bulkhead and two layers on the larger area side-wall. Full scale tests of the flight vehicle in a simulated Shuttle cargo bay, that was purged with gaseous nitrogen, gave total prelaunch heating rates of 25.9 kW and 12.9 kW for LH2 and LO2 tanks, respectively. Calorimeter tests on a representative LH2 tank sidewall TPS sample indicated that the measured unit heating rate would rapidly decrease from the prelaunch rate of 300 W/sq m to a desired rate of less than 4 W/sq m once on-orbit.

Knoll, R. H.↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Surface tension propellant control for Viking 75 Orbiter

The paper describes the selection, development and qualification of the surface tension system and includes results of low-g drop tower tests of scale models, 1-g simulation tests of low-g large ullage settling and liquid withdrawal, structural qualification tests, and propellant surface tension/contact angle studies. Subscale testing and analyses were used to evaluate the ability of the system to maintain or recover the desired propellant orientation following possible disturbances during the Viking mission. This effort included drop tower tests to demonstrate that valid wick paths exist for moving any displaced propellant back over the tank outlet. Variations in surface tension resulting from aging, temperature, and lubricant contamination were studied and the effects of surface finish, referee fluid exposure, aging, and lubricant contamination on contact angle were assessed. Results of movies of typical subscale drop tower tests and full scale slosh tests are discussed.

Dowdy, M. W.↗