Search NASA⌕ Search

SEARCH · Search NASA

Results for “functionally graded material”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

On Development and Wear Behavior of Microwave-Processed Functionally Graded Ni-SiC Clads on SS-304 Substrate

In this study, the functionally graded Ni-SiC claddings with gradual change in SiC contents were deposited on SS-304 substrate using microwave hybrid heating technique. Experimental trials were carried out inside a multimode domestic microwave device at 2.45 GHz and 900 W. The optimal exposure time of 900 W microwave power was varied with compositional gradient, and it was from 300 to 360 s. The developed functionally graded clad (FGC) was characterized by SEM/EDS, XRD and Vicker’s micro-hardness. Microstructural analysis results revealed that the FGC of approximately 2 mm thickness was developed and was free from any type of interfacial cracks and visible porosity. The maximum micro-hardness was at the top FGC layer, and its value was 1025 ± 30 HV. Three types of single-layer claddings were also developed to compare the tribological behavior of FGC. FGC exhibited 32 and 1.2 times more wear resistance than SS-304 substrate and Ni + 30% SiC layer, respectively. In the case of FGC, wear mainly occurs due to debonding of carbide particles from the matrix, while plastic deformation and strong abrasion are responsible for material loss in the case of the SS-304 substrate.

36 MATERIALS SCIENCE↗

Hemithoracic Intensity Modulated Radiation Therapy After Pleurectomy/Decortication for Malignant Pleural Mesothelioma: Toxicity, Patterns of Failure, and a Matched Survival Analysis

Purpose: To investigate safety, efficacy, and recurrence after hemithoracic intensity modulated radiation therapy after pleurectomy/decortication (PD-IMRT) and after extrapleural pneumonectomy (EPP-IMRT). Methods and Materials: In 2009-2013, 24 patients with mesothelioma underwent PD-IMRT to the involved hemithorax to a dose of 45 Gy, with an optional integrated boost; 22 also received chemotherapy. Toxicity was scored with the Common Terminology Criteria for Adverse Events v4.0. Pulmonary function was compared at baseline, after surgery, and after IMRT. Kaplan-Meier analysis was used to calculate overall survival (OS), progression-free survival (PFS), time to locoregional failure, and time to distant metastasis. Failures were in-field, marginal, or out of field. Outcomes were compared with those of 24 patients, matched for age, nodal status, performance status, and chemotherapy, who had received EPP-IMRT. Results: Median follow-up time was 12.2 months. Grade 3 toxicity rates were 8% skin and 8% pulmonary. Pulmonary function declined from baseline to after surgery (by 21% for forced vital capacity, 16% for forced expiratory volume in 1 second, and 19% for lung diffusion of carbon monoxide [P for all = .01]) and declined still further after IMRT (by 31% for forced vital capacity [P=.02], 25% for forced expiratory volume in 1 second [P=.01], and 30% for lung diffusion of carbon monoxide [P=.01]). The OS and PFS rates were 76% and 67%, respectively, at 1 year and 56% and 34% at 2 years. Median OS (28.4 vs 14.2 months, P=.04) and median PFS (16.4 vs 8.2 months, P=.01) favored PD-IMRT versus EPP-IMRT. No differences were found in grade 4-5 toxicity (0 of 24 vs 3 of 24, P=.23), median time to locoregional failure (18.7 months vs not reached, P not calculable), or median time to distant metastasis (18.8 vs 11.8 months, P=.12). Conclusions: Hemithoracic intensity modulated radiation therapy after pleurectomy/decortication produced little high-grade toxicity but led to progressive declines in pulmonary function; OS and PFS were better in PD-IMRT compared with EPP-IMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Mathematics Integrated with Computer Science through Scratch: Curricular Modules for the Middle Grades

A project funded by the National Science Foundation, Computer Science Integrated with Mathematics in Middle Schools (CSIMMS) (DRL-1640039), brought middle-school mathematics teachers together with university computer science (CS) faculty and STEM education faculty to design, develop, and test curriculum modules in which CS is integrated into instruction for middle-school general-mathematics courses. The project developed integrated math/CS curriculum modules (for grades 6, 7, and 8), complete with student tasks and teacher materials to guide classroom implementation. Across the project, sixteen teachers from four middle schools representing different school contexts (both urban and suburban, serving students from a range of demographic and socioeconomic backgrounds) participated as members of the design team and trial testers of the math/CS modules. All modules underwent multiple years of testing and refinement, with extensive input from the teachers who co-designed and implemented them. Approximately 50-100 middle-school students participated in the classes of those who taught each year. The modules in this volume feature a range of models for integrating mathematics and computer science at the 6th and 7th grade levels. All modules foreground the teaching of grade-level mathematics content, with computer science functioning to motivate and/or reinforce these ideas.

Andrews larson, Christine↗

Open-Shell Donor–Acceptor Conjugated Polymers with High Electrical Conductivity

Conductive polymers largely derive their electronic functionality from chemical doping, processes by which redox and charge-transfer reactions form mobile carriers. While decades of research have demonstrated fundamentally new technologies that merge the unique functionality of these materials with the chemical versatility of macromolecules, doping and the resultant material properties are not ideal for many applications. Here, it is demonstrated that open-shell conjugated polymers comprised of alternating cyclopentadithiophene and thiadiazoloquinoxaline units can achieve high electrical conductivities in their native “undoped” form. Spectroscopic, electrochemical, electron paramagnetic resonance, and magnetic susceptibility measurements demonstrate that this donor–acceptor architecture promotes very narrow bandgaps, strong electronic correlations, high-spin ground states, and long-range π-delocalization. A comparative study of structural variants and processing methodologies demonstrates that the conductivity can be tuned up to 8.18 S cm -1 . This exceeds other neutral narrow bandgap conjugated polymers, many doped polymers, radical conductors, and is comparable to commercial grades of poly(styrene-sulfonate)-doped poly(3,4-ethylenedioxythiophene). X-ray and morphological studies trace the high conductivity to rigid backbone conformations emanating from strong π-interactions and long-range ordered structures formed through self-organization that lead to a network of delocalized open-shell sites in electronic communication. The results offer a new platform for the transport of charge in molecular systems.

36 MATERIALS SCIENCE↗

Use of the Charlson Combined Comorbidity Index To Predict Postradiotherapy Quality of Life for Prostate Cancer Patients

Purpose: To determine the impact of pretreatment comorbidity on late health-related quality of life (HRQoL) scores after patients have undergone combined radiotherapy for prostate cancer, including high-dose rate brachytherapy boost and hormonal deprivation therapy. Methods and Materials: Results from the European Organization for Research and Treatment of Cancer QLQ-C30 questionnaire survey of 158 patients 5 years or more after completion of therapy were used from consecutively accrued subjects treated with curative radiotherapy at our institution, with no signs of disease at the time of questionnaire completion. HRQoL scores were compared with the Charlson combined comorbidity index (CCI), using analysis of covariance and multivariate regression models together with pretreatment factors including tumor stage, tumor grade, pretreatment prostate-specific antigen level, neoadjuvant hormonal treatment, diabetes status, cardiovascular status, and age and Charlson score as separate variables or the composite CCI. Results: An inverse correlation between the two HRQoL domains, long-term global health (QL) and physical function (PF) scores, and the CCI score was observed, indicating an impact of comorbidity in these function areas. Selected pretreatment factors poorly explained the variation in functional HRQoL in the multivariate models; however, a statistically significant impact was found for the CCI (with QL and PF scores) and the presence of diabetes (with QL and emotional function). Cognitive function and social function were not statistically significantly predicted by any of the pretreatment factors. Conclusions: The CCI proved to be valid in this context, but it seems useful mainly in predicting long-term QL and PF scores. Of the other variables investigated, diabetes had more impact than cardiovascular morbidity on HRQoL outcomes in prostate cancer.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Sample problems for Section III, Division 5 design by inelastic analysis of Grade 91 components

This report works through two sample design analyses of representative Grade 91 components using the ASME Boiler & Pressure Vessel Code Section III, Division 5, Appendix HBB-T rules for the strain and deformation and creep-fatigue design criteria using a design by inelastic analysis approach. The component geometries and loadings were selected to span a wide variety of potential applications. The sample components are an endplate geometry, which is fairly representative of typical pressure vessel construction, and a core block, representing a critical component in a heat pipe microreactor, which has a complicated geometry and complex thermal stress history. These sample problems serve several functions. First, they are complete worked examples of how to apply the current design by inelastic analysis rules. Second, they serve as test cases to evaluate the current rules and provide feedback on how they could be optimized to deal with complicated component geometries or to be better automated in modern finite element analysis software. Finally, the analysis here uses an inelastic constitutive model for Grade 91 developed by Argonne National Laboratory and proposed for inclusion in the ASME Boiler & Pressure Vessel Code Section III, Division 5 rules as a reference constitutive model. Using this constitutive model in the sample problem analyses tests the model in the context of the ASME Code rules. The final conclusions of this report are that the material model and the current Code rules are satisfactory, but that the Code rules could be optimized to simplify automation and reduce over conservatism. Future work should address the specific optimization topics discussed in this report.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Report summarizing demonstration of thermal conductivity measurement methods for coated zirconium cladding

Thermal diffusivity measurements on Zirconium-based cladding materials have historically been a challenge due to the difficulty to measure on specimens with curved geometries, including nuclear grade Zircaloy cladding materials. In this work, we first used Laser Flash Analysis methods to measure the thermal diffusivity of Zircaloy tubes, which show good agreement with Zircaloy plates in this work, as well as previously published data. The consistent results proved the applicability of the Laser Flash Analysis setup for investigating thermal diffusivity of Zircaloy tubes. We further investigate the hydrogen effect on thermal diffusivity of Zircaloy tubes. Hydrogen plays significant roles in temperature dependent thermal diffusivity trends of Zircaloy tube. For low hydrogen concentration, where hydride dissolved into single phase α-Zr at higher temperature, thermal diffusivity is relatively unchanged at low temperature at two phase regions (α-Zr and δ-hydride), and it increases as a function of temperature at single phase α-Zr region. For high hydrogen concentration, where phase transformation (α-Zr + δ-hydride → α-Zr + β-Zr) occurs at 567 °C, thermal diffusivity decreases as a function of temperature below 567 °C before the transformation (α-Zr and δ-hydride), while increase at higher temperature after the transformation (α-Zr and β-Zr).

36 MATERIALS SCIENCE↗

An investigation of a multi-layered oscillating heat pipe additively manufactured from Ti-6Al-4V powder

Here, a laser powder bed fusion (L-PBF) additive manufacturing (AM) method was employed for fabricating a multi-layered, Ti-6Al-4V oscillating heat pipe (ML-OHP). The 50.8 × 38.1 × 15.75 mm 3 ML-OHP consisted of four inter-connected layers of circular mini-channels, as well an integrated, hermetic-grade fill port. A series of experiments were conducted to characterize the ML-OHP thermal performance by varying power input (up to 50 W), working fluid (water, acetone, Novec™ 7200, and n-pentane), and operating orientation (vertical bottom-heating, horizontal, and vertical top-heating). The ML-OHP was found to operate effectively for all working fluids and orientations investigated, demonstrating that the OHP can function in a multi-layered form, and further indicating that one can ‘stack’ multiple, interconnected OHPs within flat media for increased thermal management. The ML-OHP evaporator size was found to depend on the layer-wise heat penetration which subsequently depends on power input and the ML-OHP design and material selection. Using neutron radiography, electron scanning microscopy and surface metrology, the ML-OHP channel structure was characterized and found to possess sintered Ti-6Al-4V powder along its periphery. The sintered channel surface, although a byproduct of the L-PBF manufacturing process, was found to behave as a secondary wicking structure for enhanced capillary pumping and wall/fluid heat transfer within the OHP. With the newfound capabilities of AM, many high heat flux thermal management devices, specifically those that employ mini- or micro-channels, can be ‘re-invented’ to possess embedded channels with atypical geometries, arrangements and surface conditions.

42 ENGINEERING↗

Clinical Outcomes and Patterns of Disease Recurrence After Intensity Modulated Proton Therapy for Oropharyngeal Squamous Carcinoma

Purpose: A single-institution prospective study was conducted to assess disease control and toxicity of proton therapy for patients with head and neck cancer. Methods and Materials: Disease control, toxicity, functional outcomes, and patterns of failure for the initial cohort of patients with oropharyngeal squamous carcinoma (OPC) treated with intensity modulated proton therapy (IMPT) were prospectively collected in 2 registry studies at a single institution. Locoregional failures were analyzed by using deformable image registration. Results: Fifty patients with OPC treated from March 3, 2011, to July 2014 formed the cohort. Eighty-four percent were male, 50% had never smoked, 98% had stage III/IV disease, 64% received concurrent therapy, and 35% received induction chemotherapy. Forty-four of 45 tumors (98%) tested for p16 were positive. All patients received IMPT (multifield optimization to n=46; single-field optimization to n=4). No Common Terminology Criteria for Adverse Events grade 4 or 5 toxicities were observed. The most common grade 3 toxicities were acute mucositis in 58% of patients and late dysphagia in 12%. Eleven patients had a gastrostomy (feeding) tube placed during therapy, but none had a feeding tube at last follow-up. At a median follow-up time of 29 months, 5 patients had disease recurrence: local in 1, local and regional in 1, regional in 2, and distant in 1. The 2-year actuarial overall and progression-free survival rates were 94.5% and 88.6%. Conclusions: The oncologic, toxicity, and functional outcomes after IMPT for OPC are encouraging and provide the basis for ongoing and future clinical studies.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

North Central Cancer Treatment Group Phase I Trial N057K of Everolimus (RAD001) and Temozolomide in Combination With Radiation Therapy in Patients With Newly Diagnosed Glioblastoma Multiforme

Background: The mammalian target of rapamycin (mTOR) functions within the PI3K/Akt signaling pathway as a critical modulator of cell survival. On the basis of promising preclinical data, the safety and tolerability of therapy with the mTOR inhibitor RAD001 in combination with radiation (RT) and temozolomide (TMZ) was evaluated in this Phase I study. Methods and Materials: All patients received weekly oral RAD001 in combination with standard chemoradiotherapy, followed by RAD001 in combination with standard adjuvant temozolomide. RAD001 was dose escalated in cohorts of 6 patients. Dose-limiting toxicities were defined during RAD001 combination therapy with TMZ/RT. Results: Eighteen patients were enrolled, with a median follow-up of 8.4 months. Combined therapy was well tolerated at all dose levels, with 1 patient on each dose level experiencing a dose-limiting toxicity: Grade 3 fatigue, Grade 4 hematologic toxicity, and Grade 4 liver dysfunction. Throughout therapy, there were no Grade 5 events, 3 patients experienced Grade 4 toxicities, and 6 patients had Grade 3 toxicities attributable to treatment. On the basis of these results, the recommended Phase II dosage currently being tested is RAD001 70 mg/week in combination with standard chemoradiotherapy. Fluorodeoxyglucose (FDG) positron emission tomography scans also were obtained at baseline and after the second RAD001 dose before the initiation of TMZ/RT; the change in FDG uptake between scans was calculated for each patient. Fourteen patients had stable metabolic disease, and 4 patients had a partial metabolic response. Conclusions: RAD001 in combination with RT/TMZ and adjuvant TMZ was reasonably well tolerated. Changes in tumor metabolism can be detected by FDG positron emission tomography in a subset of patients within days of initiating RAD001 therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Poor Baseline Pulmonary Function May Not Increase the Risk of Radiation-Induced Lung Toxicity

Purpose: Poor pulmonary function (PF) is often considered a contraindication to definitive radiation therapy for lung cancer. This study investigated whether baseline PF was associated with radiation-induced lung toxicity (RILT) in patients with non-small cell lung cancer (NSCLC) receiving conformal radiation therapy (CRT). Methods and Materials: NSCLC patients treated with CRT and tested for PF at baseline were eligible. Baseline predicted values of forced expiratory volume in 1 sec (FEV1), forced vital capacity (FVC), and diffusion capacity of lung for carbon monoxide (DLCO) were analyzed. Additional factors included age, gender, smoking status, Karnofsky performance status, coexisting chronic obstructive pulmonary disease (COPD), tumor location, histology, concurrent chemotherapy, radiation dose, and mean lung dose (MLD) were evaluated for RILT. The primary endpoint was symptomatic RILT (SRILT), including grade ≥2 radiation pneumonitis and fibrosis. Results: There was a total of 260 patients, and SRILT occurred in 58 (22.3%) of them. Mean FEV1 values for SRILT and non-SRILT patients were 71.7% and 65.9% (P=.077). Under univariate analysis, risk of SRILT increased with MLD (P=.008), the absence of COPD (P=.047), and FEV1 (P=.077). Age (65 split) and MLD were significantly associated with SRILT in multivariate analysis. The addition of FEV1 and age with the MLD-based model slightly improved the predictability of SRILT (area under curve from 0.63-0.70, P=.088). Conclusions: Poor baseline PF does not increase the risk of SRILT, and combining FEV1, age, and MLD may improve the predictive ability.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Phase I Trial of Hypofractionated Intensity-Modulated Radiotherapy With Temozolomide Chemotherapy for Patients With Newly Diagnosed Glioblastoma Multiforme

Purpose: To determine the maximal tolerated biologic dose intensification of radiotherapy using fractional dose escalation with temozolomide (TMZ) chemotherapy in patients with newly diagnosed glioblastoma multiforme. Methods and Materials: Patients with newly diagnosed glioblastoma multiforme after biopsy or resection and with adequate performance status, bone marrow, and organ function were eligible. The patients underwent postoperative intensity-modulated radiotherapy (IMRT) with concurrent and adjuvant TMZ. All patients received a total dose of 60 Gy to the surgical cavity and residual tumor, with a 5-mm margin. IMRT biologic dose intensification was achieved by escalating from 3 Gy/fraction (Level 1) to 6 Gy/fraction (Level 4) in 1-Gy increments. Concurrent TMZ was given at 75 mg/m{sup 2}/d for 28 consecutive days. Adjuvant TMZ was given at 150-200 mg/m{sup 2}/d for 5 days every 28 days. Dose-limiting toxicity was defined as any Common Terminology Criteria for Adverse Events, version 3, Grade 3-4 nonhematologic toxicity, excluding Grade 3 fatigue, nausea, and vomiting. A standard 3+3 Phase I design was used. Results: A total of 16 patients were accrued (12 men and 4 women, median age, 69 years; range, 34-84. The median Karnofsky performance status was 80 (range, 60-90). Of the 16 patients, 3 each were treated at Levels 1 and 2, 4 at Level 3, and 6 at Level 4. All patients received IMRT and concurrent TMZ according to the protocol, except for 1 patient, who received 14 days of concurrent TMZ. The median number of adjuvant TMZ cycles was 7.5 (range, 0-12). The median survival was 16.2 months (range, 3-33). One patient experienced vision loss in the left eye 7 months after IMRT. Four patients underwent repeat surgery for suspected tumor recurrence 6-12 months after IMRT; 3 had radionecrosis. Conclusions: The maximal tolerated IMRT fraction size was not reached in our study. Our results have shown that 60 Gy IMRT delivered in 6-Gy fractions within 2 weeks with concurrent and adjuvant TMZ is tolerable in selected patients with a T{sub 1}-weighted enhancing tumor <6 cm.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

PolyMat: an efficient Matlab code for multi-material topology optimization

We introduce a Matlab implementation of topology optimization for compliance minimization on unstructured polygonal finite element meshes that efficiently accommodates many materials and many volume constraints. Leveraging the modular structure of the educational code, PolyTop, we extend it to the multi-material version, PolyMat, with only a few modifications. First, a design variable for each candidate material is defined in each finite element. Next, we couple a Discrete Material Optimization interpolation with the existing penalization and introduce a new parameter such that we can employ continuation and smoothly transition from a convex problem without any penalization to a non-convex problem in which material mixing and intermediate densities are penalized. Mixing that remains due to the density filter operation is eliminated via continuation on the filter radius. To accommodate flexibility in the volume constraint definition, the constraint function is modified to compute multiple volume constraints and the design variable update is modified in accordance with the Zhang-Paulino-Ramos Jr. (ZPR) update scheme, which updates the design variables associated with each constraint independently. The formulation allows for volume constraints controlling any subset of the design variables, i.e., they can be defined globally or locally for any subset of the candidate materials. Borrowing ideas for mesh generation on complex domains from PolyMesher, we conclude which design variables are associated with each local constraint of arbitrary geometry. A number of examples are presented to demonstrate the many material capability, the flexibility of the volume constraint definition, the ease with which we can accommodate passive regions, and how we may use local constraints to break symmetries or achieve graded geometries.

79 ASTRONOMY AND ASTROPHYSICS↗

Quality of Life and Toxicity From Passively Scattered and Spot-Scanning Proton Beam Therapy for Localized Prostate Cancer

Purpose: To report quality of life (QOL)/toxicity in men treated with proton beam therapy for localized prostate cancer and to compare outcomes between passively scattered proton therapy (PSPT) and spot-scanning proton therapy (SSPT). Methods and Materials: Men with localized prostate cancer enrolled on a prospective QOL protocol with a minimum of 2 years' follow-up were reviewed. Comparative groups were defined by technique (PSPT vs SSPT). Patients completed Expanded Prostate Cancer Index Composite questionnaires at baseline and every 3-6 months after proton beam therapy. Clinically meaningful differences in QOL were defined as ≥0.5 × baseline standard deviation. The cumulative incidence of modified Radiation Therapy Oncology Group grade ≥2 gastrointestinal (GI) or genitourinary (GU) toxicity and argon plasma coagulation were determined by the Kaplan-Meier method. Results: A total of 226 men received PSPT, and 65 received SSPT. Both PSPT and SSPT resulted in statistically significant changes in sexual, urinary, and bowel Expanded Prostate Cancer Index Composite summary scores. Only bowel summary, function, and bother resulted in clinically meaningful decrements beyond treatment completion. The decrement in bowel QOL persisted through 24-month follow-up. Cumulative grade ≥2 GU and GI toxicity at 24 months were 13.4% and 9.6%, respectively. There was 1 grade 3 GI toxicity (PSPT group) and no other grade ≥3 GI or GU toxicity. Argon plasma coagulation application was infrequent (PSPT 4.4% vs SSPT 1.5%; P=.21). No statistically significant differences were appreciated between PSPT and SSPT regarding toxicity or QOL. Conclusion: Both PSPT and SSPT confer low rates of grade ≥2 GI or GU toxicity, with preservation of meaningful sexual and urinary QOL at 24 months. A modest, yet clinically meaningful, decrement in bowel QOL was seen throughout follow-up. No toxicity or QOL differences between PSPT and SSPT were identified. Long-term comparative results in a larger patient cohort are warranted.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Dielectric and ferroelectric response of compositionally graded bilayer and trilayer composites of BaTiO{sub 3} and 0.975BaTiO{sub 3}-0.025Ba(Cu{sub 1/3}Nb{sub 2/3})O{sub 3}

In this paper, we report the dielectric and ferroelectric response of compositionally graded bilayer and trilayer composites consisting of BaTiO{sub 3} (BT) and 0.975BaTiO{sub 3}-0.025Ba(Cu{sub 1/3}Nb{sub 2/3})O{sub 3} (BTBCN). Two types of graded bilayer samples were synthesized, one with same thickness of BT and BTBCN while other with different layer thicknesses. The graded trilayer sample consisted of BT layer sandwiched between two BTBCN layers of equal thickness. Scanning electron microscopy and transmission electron microscopy images showed a sharp interface with needle-shape domains across the interface. The domain size on BT side was found to be larger than that on BTBCN side. The temperature dependence of dielectric response for all composite systems was found to exhibit shifting in characteristic Curie peak compared to constituent material which was associated to coupling between layers. Moreover, the differences in grain size, tetragonality, domain mobility of each layer was found to perturb the electrical response of composite. The polarization mismatch between uncoupled BT and BTBCN established internal electric field in composite specimen and defined new polarization states in each layer by perturbing free energy functional of the composite specimen. Dynamic hysteresis behaviors and power-law scaling relations of all specimens were determined from polarization-electric field hysteresis loop measurements as a function of frequency. All systems were found to exhibit similar dynamic scaling relationships. Hysteresis area <A>, P{sub r}, and E{sub C} decreased with increasing frequency due to delayed response but increased with increasing applied electric field due to enhancement of driving force. Trilayer system was found to exhibit strong internal-bias field and double hysteresis behavior. The coupling effect resulting due to polarization mismatch between layers had substantial influence on the dynamic hysteresis behavior and power-law scaling relations.

36 MATERIALS SCIENCE↗

Development of Monitoring Techniques for Laser Powder Bed Additive Manufacturing of Metal Structures (Progress Report)

The Transformational Challenge Reactor (TCR) program is leveraging additive manufacturing (AM) technologies to fabricate nuclear grade components to be assembled into a fully functional microreactor core. Compared to traditional manufacturing technologies, additive manufacturing technologies allow (1) observation of the manufacturing process at a much higher resolution in real time using in situ monitoring technologies to capture the sensor signature that scientifically describes each event occurring over time and space, and (2) validation of the manufacturing process quality using domain-informed data analytics techniques as a potential qualification and certification methodology for the final component. This report provides an update on the program work on laser powder bed fusion in-situ process monitoring and associated data analytics results. Examples are provided to illustrate the progress. Elements of the Digital Thread and data management are discussed in the main document, and an extensive supplemental material section is provided detailing the Digital Platform, as well as its implementation and components. In conclusion the path forward for the next fiscal year is discussed.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Phase II Trial of Radiosurgery to Magnetic Resonance Spectroscopy-Defined High-Risk Tumor Volumes in Patients With Glioblastoma Multiforme

Purpose: To determine the efficacy of a Gamma Knife stereotactic radiosurgery (SRS) boost to areas of high risk determined by magnetic resonance spectroscopy (MRS) functional imaging in addition to standard radiotherapy for patients with glioblastoma (GBM). Methods and Materials: Thirty-five patients in this prospective Phase II trial underwent surgical resection or biopsy for a GBM followed by SRS directed toward areas of MRS-determined high biological activity within 2 cm of the postoperative enhancing surgical bed. The MRS regions were determined by identifying those voxels within the postoperative T2 magnetic resonance imaging volume that contained an elevated choline/N-acetylaspartate ratio in excess of 2:1. These voxels were marked, digitally fused with the SRS planning magnetic resonance image, targeted with an 8-mm isocenter per voxel, and treated using Radiation Therapy Oncology Group SRS dose guidelines. All patients then received conformal radiotherapy to a total dose of 60 Gy in 2-Gy daily fractions. The primary endpoint was overall survival. Results: The median survival for the entire cohort was 15.8 months. With 75% of recursive partitioning analysis (RPA) Class 3 patients still alive 18 months after treatment, the median survival for RPA Class 3 has not yet been reached. The median survivals for RPA Class 4, 5, and 6 patients were 18.7, 12.5, and 3.9 months, respectively, compared with Radiation Therapy Oncology Group radiotherapy-alone historical control survivals of 11.1, 8.9, and 4.6 months. For the 16 of 35 patients who received concurrent temozolomide in addition to protocol radiotherapeutic treatment, the median survival was 20.8 months, compared with European Organization for Research and Treatment of Cancer historical controls of 14.6 months using radiotherapy and temozolomide. Grade 3/4 toxicities possibly attributable to treatment were 11%. Conclusions: This represents the first prospective trial using selective MRS-targeted functional SRS combined with radiotherapy for patients with GBM. This treatment is feasible, with acceptable toxicity and patient survivals higher than in historical controls. This study can form the basis for a multicenter, randomized trial.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Electrocatalytic Hydrogenation of Biomass-Derived Organics: A review

Sustainable energy generation calls for a shift away from centralized, high-temperature, energy-intensive processes to decentralized, low-temperature conversions that can be powered by electricity produced from renewable sources. Electrocatalytic conversion of biomass-derived feedstocks would allow carbon recycling of distributed, energy-poor resources in the absence of sinks and sources of high-grade heat. Selective, efficient electrocatalysts that operate at low temperatures are needed for electrocatalytic hydrogenation (ECH) to upgrade the feedstocks. For effective generation of energy-dense chemicals and fuels, two design criteria must be met: (i) a high H:C ratio via ECH to allow for high-quality fuels and blends, and (ii) a lower O:C ratio in the target molecules via electrochemical decarboxylation/deoxygenation to improve the stability of fuels and chemicals. The goal of this review is to determine whether the following questions have been sufficiently answered in open literature, and if not, what additional information is required: (1) What organic functionalities are accessible for electrocatalytic hydrogenation under a set of reaction conditions? How do substitutions and functionalities impact the activity and selectivity of ECH? (2) What material properties cause an electrocatalyst to be active for ECH? Can general trends in ECH be formulated based on the type of electrocatalyst? (3) What is the impact of reaction (electrolyte concentration, pH, operating potential) and reactor type conditions?

Catalysts, redox reactions, hydrocarbons, Aromatic↗