Search NASA⌕ Search

SEARCH · Search NASA

Results for “gamma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Performance of the AstroPix Prototype Module for the Barrel Imaging Calorimeter at the ePIC Detector and in Space-Based Payloads

AstroPix is a high-voltage CMOS (HV-CMOS) monolithic active pixel sensor originally developed to enable precision gamma-ray imaging and spectroscopy in the medium-energy regime (~100 keV–100 MeV) based on the groundwork laid by ATLASpix and MuPix. It features a 500 μm pixel pitch, in-pixel amplification and digitization, and low power consumption (~3-4 mW/cm2), making it scalable for large-area, multilayer telescope detector planes. The detectors have a designed dynamic range of 25 keV to 700 keV. With these features, AstroPix meets the requirements of future space-based high-energy telescopes and the imaging layers of the Barrel Imaging Calorimeter (BIC) in the Electron-Proton/Ion Collider (ePIC) detector at the future Electron-Ion Collider (EIC). For the space-based payload, AstroPix is being integrated into sounding rocket and balloon payloads to demonstrate the technical readiness of the devices. For BIC, AstroPix-based imaging layers interleaved within the lead/scintillating-fiber (Pb/SciFi) sampling calorimeter provide granular shower imaging, enabling key performance features such as electron/pion or gamma/neutral pion separation. As part of the ongoing detector R&D efforts, we have been testing various AstroPix_v3 configurations: the single chip, a quad-chip assembly, a three-layer stack of quad chips, and a 9-chip module that represents the smallest prototype unit of the BIC imaging layer. This presentation will highlight recent performance test results from these AstroPix detector configurations.

Kim, Bobae (ORCID:0000000295396815)↗

SNM Radiation Signature Classification Using Different Semi-Supervised Machine Learning Models

The timely detection of special nuclear material (SNM) transfers between nuclear facilities is an important monitoring objective in nuclear nonproliferation. Persistent monitoring enabled by successful detection and characterization of radiological material movements could greatly enhance the nuclear nonproliferation mission in a range of applications. Supervised machine learning can be used to signal detections when material is present if a model is trained on sufficient volumes of labeled measurements. However, the nuclear monitoring data needed to train robust machine learning models can be costly to label since radiation spectra may require strict scrutiny for characterization. Therefore, this work investigates the application of semi-supervised learning to utilize both labeled and unlabeled data. As a demonstration experiment, radiation measurements from sodium iodide (NaI) detectors are provided by the Multi-Informatics for Nuclear Operating Scenarios (MINOS) venture at Oak Ridge National Laboratory (ORNL) as sample data. Anomalous measurements are identified using a method of statistical hypothesis testing. After background estimation, an energy-dependent spectroscopic analysis is used to characterize an anomaly based on its radiation signatures. In the absence of ground-truth information, a labeling heuristic provides data necessary for training and testing machine learning models. Supervised logistic regression serves as a baseline to compare three semi-supervised machine learning models: co-training, label propagation, and a convolutional neural network (CNN). In each case, the semi-supervised models outperform logistic regression, suggesting that unlabeled data can be valuable when training and demonstrating value in semi-supervised nonproliferation implementations.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Evaluation of Machine Learning Techniques for Isotope Identification Contextualized by Training and Testing Spectral Similarity

Precise gamma-ray spectral analysis is crucial in high-stakes applications, such as nuclear security. Research efforts toward implementing machine learning (ML) approaches for accurate analysis are limited by the resemblance of the training data to the testing scenarios. The underlying spectral shape of synthetic data may not perfectly reflect measured configurations, and measurement campaigns may be limited by resource constraints. Consequently, ML algorithms for isotope identification must maintain accurate classification performance under domain shifts between the training and testing data. To this end, four different classifiers (Ridge, Random Forest, Extreme Gradient Boosting, and Multilayer Perceptron) were trained on the same dataset and evaluated on twelve other datasets with varying standoff distances, shielding, and background configurations. A tailored statistical approach was introduced to quantify the similarity between the training and testing configurations, which was then related to the predictive performance. Wilcoxon signed-rank tests revealed that the OVR-wrapped XGB significantly outperformed the other algorithms, with confidence levels of 99.0% or above for the 133Ba, 60Co, 137Cs, and 152Eu sources. The findings from this work are significant as they outline techniques to promote the development of robust ML-based approaches for isotope identification.

domain adaptation↗

Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol

Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10 10 Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of 241 Am.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

AFRRI TRIGA Reactor Neutron and Gamma Dose Characterization Preliminary Results

Integral Experiment Request (IER) 484 is part of a series of dose characterization and nuclear accident dosimeter (NAD) exercises performed under the Department of Energy (DOE) Nuclear Criticality Safety Program (NCSP). The Armed Forces Radiobilogy Research Institute (AFRRI) 1.1 MW Training, Research, Isotopes, General Atomics (TRIGA) Mark-F reactor is the third facility to undergo a dose study to establish reference dose values. A preliminary measurement was performed earlier this year, where a variety of foils were irradiated and activation gamma rays were measured using a high-purity germanium (HPGe) detector. The data was taken and analyzed to calculate the neutron spectrum in the irradiation facility. This paper will present preliminary results of the neutron dose measured. The characterization of the AFRRI dose field is planned in August.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Pixel Array Germanium Detectors for Nuclear Physics (Final Technical Report)

The Department of Energy (DOE) Office of Nuclear Physics supports the development and maintenance of germanium gamma-ray detector arrays at national laboratories and universities. Germanium gamma-ray detectors provide state-of-the-art gamma-ray energy resolution, making them critical for gamma-ray and x-ray spectroscopy in Nuclear Physics. Furthermore, detector segmentation and charge-signal waveform processing enables 3-dimensional (3D) measurement of gamma-ray interaction locations needed for the highest-fidelity Nuclear Physics experiments. Attaining and maintaining excellent gamma-ray energy resolution depends largely on the naturally excellent charge-collection properties of germanium crystals. However, the optimal method for achieving the best practical 3D spatial resolution within the detector volume at high counting rates is less clear.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response of a high-pressure 4 He scintillation detector to nuclear recoils up to 9 MeV

Helium-4-based scintillation detector technology is emerging as a strong alternative to pulse-shape discrimination-capable organic scintillators for fast neutron detection and spectroscopy, particularly in extreme gamma-ray environments. The 4 He detector is intrinsically insensitive to gamma radiation, as it has a relatively low cross-section for gamma-ray interactions, and the stopping power of electrons in the 4 He medium is low compared to that of 4 He recoil nuclei. Consequently, gamma rays can be discriminated by simple energy deposition thresholding instead of the more complex pulse shape analysis. The energy resolution of 4 He scintillation detectors has not yet been well-characterized over a broad range of energy depositions, which limits the ability to deconvolve the source spectra. In this work, an experiment was performed to characterize the response of an Arktis S670 4 He detector to nuclear recoils up to 9 MeV. The 4 He detector was positioned in the center of a semicircular array of organic scintillation detectors operated in coincidence. Deuterium–deuterium and deuterium–tritium neutron generators provided monoenergetic neutrons, yielding geometrically constrained nuclear recoils ranging from 0.0925 to 8.87 MeV. The detector response provides evidence for scintillation linearity beyond the previously reported energy range. Finally, the measured response was used to develop an energy resolution function applicable to this energy range for use in high-fidelity detector simulations needed by future applications.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Impact of corrosion layer composition and thermal pretreatment on the radiolytic generation of molecular hydrogen from aluminum alloys

To fully evaluate the feasibility of extending the dry storage of aluminum-clad spent nuclear fuel (ASNF) in helium-backfilled cannisters, the amount of radiation-induced molecular hydrogen (H 2 ) generated and the impact of absorbed radiation dose on the ASNF corrosion layer composition must be accurately assessed. Here, in this study, we report a slowing in the rate of radiolytic H 2 generation for pre-corroded AA1100 and AA6061 aluminum alloy coupons irradiated to up to 53 MGy of absorbed cobalt-60 gamma dose. By exploring a variety of thermal pretreatment conditions for AA6061 coupons, we find that the “steady-state” yield of H 2 depends more on the aluminum alloy used than on the treatments applied prior to dry storage. Scanning electron microscopy and positron annihilation lifetime spectroscopy techniques also provided evidence for gamma radiation-induced defects in the corrosion layers of the investigated aluminum alloy coupons for high absorbed doses (~50 MGy), the consequences of which on cladding integrity and H 2 generation should be explored in future works.

38 - RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCL↗

Absolute efficiency response of the γ-ray spectrometer GRETINA for high-energy γ rays up to 6 MeV

GRETINA (Gamma-Ray Energy Tracking In-beam Nuclear Array), a state-of-the-art γ-ray tracking spectrometer, has been instrumental in advancing nuclear structure studies, particularly in experiments using fast beams of rare isotopes where the γ rays emitted in flight are subject to large Doppler shifts. This work presents an experimental determination of the γ-ray detection efficiency of GRETINA at energies up to 6 MeV. The high-energy γ rays originated from states that were populated in nucleon-removal reactions from a projectile beam at an intermediate beam energy of about 85 MeV/nucleon. Utilizing γ-γ coincidences, efficiency values were extracted in-beam and translated into a source efficiency at rest employing GEANT4 Monte Carlo simulations. A systematic discrepancy in the efficiency of the forward-positioned detectors was identified which is attributed to specific dead-time effects caused by high-energy light-particle events prevalent at forward angles, generating signals in the Ge crystals that saturate the preamplifier’s first stage. Furthermore, this study provides refined efficiency benchmarks for in-beam experiments, improving the accuracy of quantitative γ-ray spectroscopy analyses with GRETINA and GRETA (Gamma Ray Energy Tracking Array) in the future.

GRETINA↗

Identification, isolation, and characterization of a novel type of Fukushima-derived microparticle

Abstract In the course of the Fukushima nuclear accident, radionuclides were released in various forms, including so-called radiocesium-bearing microparticles (CsMP). So far, four types of CsMP were described: Type A is smaller in size (< 10 μm), Types B, C, and D are larger (> 100 μm). In this work, we present a novel type of CsMP (proclaimed Type E). Three particles of Type E were extracted from a contaminated blade of grass that was sampled 1.5 km from the Fukushima Daiichi nuclear power plant in late 2011. They were located using autoradiography, isolated using an optical microscope and micromanipulator, and characterized using scanning electron microscopy, energy dispersive x-ray spectroscopy, and low-level gamma-ray spectrometry. Type E CsMPs are 10–20 μm in size and exhibit an unusually low and barely detectable 137 Cs activity of only ≤ 10 mBq per particle. Their brittle and fragile character may indicate a high surface tension.

137Cs↗

An analysis of gamma-ray data collected at traffic intersections in Northern Virginia

Gamma-ray spectral data were collected from sensors mounted to traffic signals around Northern Virginia. The data were collected over a span of approximately fifteen months. A subset of the data were analyzed manually and subsequently used to train machine-learning models to facilitate the evaluation of the remaining 50k anomalous events identified in the dataset. We describe the analysis approach used here and discuss the results in terms of radioisotope classes and frequency patterns over day-of-week and time-of-day spans. Data from this work has been archived and is available for future and ongoing research applications.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of active interrogation methods for source location in a scattering and absorbing medium, consisting of PGNAA, and an AmBe quasi-forward biased directional source

Source location of Special Nuclear Material (SNM) encompassing 95% 235 U and 239 Pu is identified by utilizing a directional source from Patent No: US20190013109A1 using Prompt Gamma Neutron Activation Analysis (PGNAA) and neutron spectroscopy simulated with Monte-Carlo N-Particle transport 6.2 (MCNP). BC-408, HPGe, LaBr 3 detector arrays were used to identify the location of the SNM using total counts incident on each detector, and PGNAA photopeaks from HPGe and LaBr 3 detector arrays in a polyethylene shield. The conducted simulations varied the volume and location of the SNM in the MCNP input files to observe how the source location method behaved. PGNAA photopeaks used for source identification include 61 keV from fission, 2.223 MeV prompt gamma from hydrogen, 511 keV annihilation, and a single and double escape peaks from the prompt gamma interaction from hydrogen. The capabilities of each detector systems to acquire well resolved photopeaks with a 1% relative error or less, and total relative error for F4 and F8 tallies were less than 0.015% relative error. Source predictions of the SNM with uneven amounts of polyethylene shielding between the source and detectors was observed to overpredict and give invalid source location predictions. Source locations of the SNM with even amounts of polyethylene material between the source and each detector were found to be valid. With a 1 Ci 241 Am source activity, it was determined that 1630 s were needed to obtain the results for each detector system with the quasi-forward directional AmBe source. Coupling source and material identification together would increase acquisition time but would only require one system to determine.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Separation of rare earth element radioisotopes by reverse-phase high-speed counter-current chromatography

Analytical scale purification of rare earth element (REE) radioisotopes is typically accomplished using cation-exchange resins (e.g. AG 50W-X8) and high-performance liquid chromatography (HPLC). Despite the variety of improvements made since the development of this separation process in the 1950s, nearest neighbor separations remain a challenge, as does the issue of irreversible sample adsorption. Herein, we report a study that evaluates the potential of high-speed counter-current chromatography (HSCCC) as an alternative method for purifying REE elements, with specific reference to separations of fission product REE of interest to nuclear forensics. Complementary HSCCC REE separation experiments, one spiked with radiotracer and REE fission product activity, allowed for in depth analysis of resulting fractions from both an elemental (inductively coupled plasma atomic emission spectroscopy, ICP-AES) and radiological (gamma-ray spectrometry, beta counting) purity perspective. The highly reproducible nature of separation profiles generated from HSCCC instruments was leveraged to simplify work-up of samples containing radioisotopes. Subsequent radioanalytical evaluation revealed minimal carryover of Eu into neighboring Sm and Tb fractions (as indicated by presence of 150Eu), and trace contamination of the Tb fraction with Y (as indicated by presence of 91Y). Subtle differences in stationary phase retention across the two columns were reflected in significant variations in decontamination factors of duplicate parallel separations. Furthermore, these differences paired with obtained distribution of radioisotopes provided valuable insights into future improvements. Collectively, this study represents a significant step forward in development of HSCCC technology for task specific REE radioisotope purification.

07 ISOTOPE AND RADIATION SOURCES↗

Mixed-Material Scintillators (MMSS Quarterly Report FY20Q2)

This project aims to invent, model, and prototype mixed-material scintillator systems (MMSSs), a new class of radiation detectors that use heterogenous internal structures of different scintillating materials to detect additional properties of radiation. These internal structures can be produced using additive manufacture (3D printing) of scintillator, a currently emerging application of additive manufacture technology. MMSSs combine the low cost and complexity of conventional scintillation detectors with capabilities currently only available in more expensive and complex detectors. By identifying promising MMSS designs, this project will enable a new class of detectors to meet DNN’s mission needs for SNM detection. This quarter, we delivered one the MMSS Particle-ID Modeling report, a major deliverable of this project. This report describes our results on simulations of the particle-ID (PID) class of detectors. We found that these detectors outperform competing approaches for neutron-gamma discrimination, neutron source pointing, and neutron spectroscopy. Further highlights of the report are described below. During this quarter, We alerted HQ to a change in schedule for the remaining simulations planned for this project: we plan to put off further simulation and reporting of the position-resolving (PR) detector class until July. This change in schedule has allowed us to go into additional detail in the PID work that is both very promising and motivates our upcoming proposal. The other active task in this project is prototyping 3D-printed scintillators with the aim of realizing the designs we’ve simulated. On that front, we had three focuses: measuring the light output, increasing the size of printed parts, and combining blue and green scintillators. We succeeded in measuring the light output, showing an output of 30% of commercial standard. This result leaves room for improvement but is within striking distance of where we need to be. We were on track to demonstrate a key requirement for increasing the size of parts and also to show combined green/blue prints before the laboratory moved to a Minimum Safe (MinSafe) Operations posture as a result of local Shelter In Place orders due to Covid-19.

42 ENGINEERING↗