Play Fairway Analysis CA-NV-OR: Figures on 2km Grids
Various data sets displayed on a 2km grid for the Play Fairway Analysis CA-NV-OR area.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Various data sets displayed on a 2km grid for the Play Fairway Analysis CA-NV-OR area.
The dynamic analysis of a grid structure hung from the ceiling by two steel wires is described. The method of approach uses the discrete mass model system. The concept of the bifilar pendulum is used in writing the equation of motion. Assumptions are made with regard to the bar stiffnesses in the vertical and horizontal planes. The discrete mases are assumed to be connected by inextensible massless strings that do not provide any torsion or bending. The modal frequencies obtained by this method are compared with those obtained from the finite element model.
Distributed energy resources and the number of relays are expected to rise in modern electrical grids; consequently, relay misoperations are also expected to grow. Relays can detect electrical fault types using an internal algorithm and can display the result using light indicators on the front of the relay. However, some relays’ internal algorithms for predicting types of electrical faults could be improved. This study assesses a relay’s external and internal algorithms with an Advanced Synchronized Time Digital Grid Twin (ASTDGT) testbed with paired relays. A misoperation relay analysis focused on measuring the accuracy of using the boundary admittance (the external algorithm) versus the set-default (the internal algorithm) relay method to determine the electrical fault types was performed. In this study, the internal and external relay algorithms were assessed with a synchronized time digital grid twin testbed using a real-time simulator. This testbed evaluated two sets of logic at the same time with the digital grid twin and paired relays in the loop. Different types of electrical faults were simulated, and the relays’ recorded events and electrical fault light indicator states were collected from the human–machine interfaces. This ASTDGT testbed with paired relays successfully evaluated the relay algorithm misoperations. The boundary admittance method had an accuracy of 100% for line-to-line, line-to-ground, and line-to-line ground faults.
The Large Hadron Collider (LHC), operating at the international CERN Laboratory in Geneva, Switzerland, is leading Big Data driven scientific explorations. ATLAS, one of the largest collaborations ever assembled in the the history of science, is at the forefront of research at the LHC. To address an unprecedented multi-petabyte data processing challenge, the ATLAS experiment is relying on a heterogeneous distributed computational infrastructure. To manage the workflow for all data processing on hundreds of data centers the PanDA (Production and Distributed Analysis)Workload Management System is used. An ambitious program to expand PanDA to all available computing resources, including opportunistic use of commercial and academic clouds and Leadership Computing Facilities (LCF), is realizing within BigPanDA and megaPanDA projects. These projects are now exploring how PanDA might be used for managing computing jobs that run on supercomputers including OLCF’s Titan and NRC-KI HPC2. The main idea is to reuse, as much as possible, existing components of the PanDA system that are already deployed on the LHC Grid for analysis of physics data. The next generation of PanDA will allow many data-intensive sciences employing a variety of computing platforms to benefit from ATLAS experience and proven tools in highly scalable processing.
Local Fourier analysis is a useful tool for predicting and analyzing the performance of many efficient algorithms for the solution of discretized PDEs, such as multigrid and domain decomposition methods. The crucial aspect of local Fourier analysis is that it can be used to minimize an estimate of the spectral radius of a stationary iteration, or the condition number of a preconditioned system, in terms of a symbol representation of the algorithm. In practice, this is a “minimax” problem, minimizing with respect to solver parameters the appropriate measure of work, which involves maximizing over the Fourier frequency. Often, several algorithmic parameters may be determined by local Fourier analysis in order to obtain efficient algorithms. Analytical solutions to minimax problems are rarely possible beyond simple problems; the status quo in local Fourier analysis involves grid sampling, which is prohibitively expensive in high dimensions. In this paper, we propose and explore optimization algorithms to solve these problems efficiently. Finally, several examples, with known and unknown analytical solutions, are presented to show the effectiveness of these approaches.
This report describes one methodology of projecting energy consumption of the US residential and commercial building sectors using NREL's ResStock™ and ComStock™ as well as growth rates derived from EIA's Annual Energy Outlook (AEO). The impetus for this work is to provide an intermediate method for compiling demand-side sectoral energy projections that is suitable for grid-scale analysis, such as NREL's Standard Scenarios. ResStock and ComStock are physics-based and statistically representative building stock models of the US residential and commercial sector, respectively. Using the 2012 actual meteorological year (AMY) weather data, the sectoral energy baselines are simulated and then segmented along key dimensions (e.g., geography, dwelling/building type). The segmented results are then scaled using the corresponding annual growth rates derived from the 2021 AEO reference case to produce energy projections out to 2050. The compiled result is a demand-side grid model (dsgrid) data set suitable for use in NREL's large-scale grid models, such as the Regional Energy Deployment System (ReEDS). This simple projection method does not endogenously represent how the building stock could evolve through time. Most notably, it does not reflect large-scale electrification, for example, the conversion of space heating, water heating, clothes drying, and cooking from primary fossil fuels to electricity, as this is not part of AEO's reference case assumptions. Nonetheless this approach is more resolved and potentially extensible compared to the current method used by Standard Scenarios's reference case, which augments a sector's total load based on a single growth rate from AEO.
The computer program user's manual for the ADPACAPES (Advanced Ducted Propfan Analysis Code-Average Passage Engine Simulation) program is included. The objective of the computer program is development of a three-dimensional Euler/Navier-Stokes flow analysis for fan section/engine geometries containing multiple blade rows and multiple spanwise flow splitters. An existing procedure developed by Dr. J. J. Adamczyk and associates at the NASA Lewis Research Center was modified to accept multiple spanwise splitter geometries and simulate engine core conditions. The numerical solution is based upon a finite volume technique with a four stage Runge-Kutta time marching procedure. Multiple blade row solutions are based upon the average-passage system of equations. The numerical solutions are performed on an H-type grid system, with meshes meeting the requirement of maintaining a common axisymmetric mesh for each blade row grid. The analysis was run on several geometry configurations ranging from one to five blade rows and from one to four radial flow splitters. The efficiency of the solution procedure was shown to be the same as the original analysis.
Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of a conceptual microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.
Flexibility is the capability of the power grid to maintain a balance between electricity generation and variable demand. This study presents preliminary results evaluating the impact of geothermal district heating systems on the flexibility of microgrid in Tuttle, Oklahoma. Heating demand profiles were modeled using EnergyPlus for the district that includes two schools and 250 single-family houses. Then, geothermal energy production was modeled using GEOPHIRES to estimate how much heating demand in the district can be supplied by five different geothermal system scenarios. The results indicated that geothermal energy production varied depending on the resource temperature at different depths, system configurations, and flow rates. For the grid flexibility analysis, electricity consumptions in the five geothermal systems were estimated for pump operations to circulate water from the wells to radiators, while electricity consumption by air-source heat pump in the base case was estimated to supply the same heating load. Electricity consumption in the geothermal systems was significantly lower than those in base cases. The electricity saved by the geothermal system was then incorporated into the microgrid electrical load profiles where variable renewable electricity generation is significantly high. The results visually showed that geothermal district heating system can improve grid flexibility as a baseload during the winter season. The results also highlighted potential opportunities to save energy costs that will be further analyzed in future study.
This project aims to develop multi-scale building energy data, potentially improving the representation of the U.S. buildings sector in GCAM-USA, an U.S.-focused human-energy-Earth systems model. Existing building energy datasets are typically limited to national or regional levels, which constrains the ability of models to capture fine-scale human-energy-Earth systems interactions and reduces their relevance for decision-making on issues such as energy security, resilience, and energy planning. By leveraging AI and advanced data integration methods, this work fuses multiple existing datasets to enhance the physical and geographic representation of both residential and commercial building energy use. So far, progress includes processing residential building data, designing the data structure for commercial buildings, and testing AI approaches for integrating datasets and addressing spatial-temporal gaps. This effort can not only advances GCAM-USA’s capability in modeling the buildings sector but also supports broader DOE missions, such as developing digital testbeds, enhancing grid resilience analysis, and improving building–energy system modeling at decision-relevant scales.
The increasing penetration of renewable energy resources such as solar and wind via power electronic inverters is challenging grid dynamics, as well as grid planning, operation, and protection. Recently, the North American Electric Reliability Corporation (NERC) has reported a series of similar events of the unintended loss of solar generation in Southern California over a large geographic area following the transmission-level disturbances. These events highlight the importance of understanding the characteristics of the transmission-side disturbances propagating into the distribution systems and their impacts on the operation of inverter-based resources. In this paper, a real-time electromagnetic simulation testbed is constructed for real-time electromagnetic simulations to generate realistic transmission-level disturbances and investigate their impacts on the solar PV operation under different fault types and locations, solar penetration levels, and loading levels. Through the simulation analysis and grid strength assessment, it is found that the grid strength at points of integration (POIs) of solar PVs significantly affects the transient stability of solar generators. Particularly, undesirable transient stability events are more likely to occur at the weak POIs following the transmission-level disturbances. Moreover, undesirable transient stability events become severer when the transmission-level disturbance is closer to the weak POIs or the disturbances become more serious. Additionally, the impact of the transmission-level disturbances on the solar PVs at the weak POIs exacerbate with the increasing solar penetration levels and loading levels. Thus, it is important to study and develop new technologies for grid planning, operation, and protection in weak grid conditions to address the emerging issues of integrating the high penetration of solar PVs and other IBRs.
The Distribution System Operator with Transactive (DSO+T) study investigates the engineering and economic performance of a transactive energy retail market coordinating a high penetration of customer-side flexible energy assets. The study seeks to answer whether such an implementation is cost effective for customers, recovers sufficient revenue for DSOs, and is equally applicable and beneficial to a range of flexible asset types, renewable generation scenarios, and market assumptions. This report volume provides a detailed set of results for the DSO+T study extending results presented in Volumes 1, 2, and 4. The engineering and economic performance of the transactive energy scheme is presented for two separate flexible asset deployments: flexible loads (HVAC units and residential water heaters) and behind-the-meter batteries. The results of each transactive case are compared to a business-as-usual case. These cases are subject to two different renewable generation scenarios, a moderate renewable generation scenario, representative of current levels of renewable generation deployment, and a future high renewables scenario, including the increased deployment of rooftop solar photovoltaic and electric vehicles. The transactive coordination scheme is shown to produce effective and stable control and decrease peak loads 9–15%. The resulting annual demand flexibility provides net economic savings of $3.3–5.0B per year for a region the size of Texas. Detailed analysis shows that net benefits were seen for a range of distribution system operator, customer, and flexible asset types. Both participating customer (with transactive flexible assets) and nonparticipating customers (with nonflexible assets) see reductions in annual utility bills and net annual energy expenses in the range of 10–16%.
The purpose of this study is the development of a three-dimensional Euler/Navier-Stokes flow analysis for fan section/engine geometries containing multiple blade rows and multiple spanwise flow splitters. An existing procedure developed by Dr. J. J. Adamczyk and associates and the NASA Lewis Research Center was modified to accept multiple spanwise splitter geometries and simulate engine core conditions. The procedure was also modified to allow coarse parallelization of the solution algorithm. This document is a final report outlining the development and techniques used in the procedure. The numerical solution is based upon a finite volume technique with a four stage Runge-Kutta time marching procedure. Numerical dissipation is used to gain solution stability but is reduced in viscous dominated flow regions. Local time stepping and implicit residual smoothing are used to increase the rate of convergence. Multiple blade row solutions are based upon the average-passage system of equations. The numerical solutions are performed on an H-type grid system, with meshes being generated by the system (TIGG3D) developed earlier under this contract. The grid generation scheme meets the average-passage requirement of maintaining a common axisymmetric mesh for each blade row grid. The analysis was run on several geometry configurations ranging from one to five blade rows and from one to four radial flow splitters. Pure internal flow solutions were obtained as well as solutions with flow about the cowl/nacelle and various engine core flow conditions. The efficiency of the solution procedure was shown to be the same as the original analysis.
This report summarizes a rigorous valuation analysis methodology used by the Distribution System Operator with Transactive (DSO+T) study to estimate the financial benefits and costs of adopting Transactive Energy coordination of distributed energy resources for key stakeholders (for example distribution system operators and customers). This was achieved by modeling the value exchanges between stakeholders and determining the annualized costs and revenues experienced by stakeholders, enabling the evaluation of overall impact on stakeholder’s annualized cash flow. Extensive work was conducted developing methods to estimate the operating costs of distribution system operators at a level of granularity that would allow the financial impact of implementing a transactive energy approach to be estimated. This work included developing parametric models for labor and software costs, distribution system capital and maintenance costs, growth rates, and factors to determine annualized costs of capital investments. Simulation results were used to calculate wholesale energy costs and revenues from retail sales. Valuation analysis methods were also developed for other stakeholders including customers, the transmission system operator, independent system operator, and generators. The resulting capability allows a complete mapping of the flow of financial value between stakeholders that can be directly integrated with the results of demand flexibility simulations. Example results are provided for a business-as-usual case and compared to a transactive energy case as well as to actual cost data.
Combined Heat and Power (CHP) systems, as a proven technology, provide numerous benefits to the plant owner by saving electricity bill, reducing carbon dioxide emissions, and improving electricity service reliability. However, their integration into the distribution grid faces many barriers including the complexity of grid code requirements and the lack of technical expertise in commercial and small industrial plants to interface with the utility and accelerate the interconnection process. To solve these issues, this study proposes a converter-interfaced solution for CHP integration. Simulations including various fault scenarios and load flow under different grid conditions are carried out to compare technical performances of the proposed solution with directly-coupled CHP. Results show that the generator size of converter-interfaced CHP can be reduced by approximately 25% and it also provides advantageous features such as reduced stress level under fault conditions and a better dynamic stability margin. In addition, a power factor controller is designed and reactive power from CHP is dispatched in such a way that the CHP plant is compliant with power factor requirements from utilities under all operating conditions.
A technoeconomic analysis of grid to low temperature electrolysis (Grid-LTE), photovoltaic to low temperature electrolysis (PV-LTE), concentrating solar power to high temperature electrolysis (CSP-HTSE) and a concentrating solar power with PV to high temperature electrolysis (CSP-PV-HTSE) centralized hydrogen production systems are analyzed to assess the economics of system and to provide a baseline for comparing these technologies against hydrogen production cost targets. A framework integrating the system advisor model (SAM) and US Department of Energy hydrogen production models (H2A) is developed to assess these systems. The hydrogen levelized cost given current and future assumptions for technology cost and performance is evaluated at optimal system configurations. The framework described in this report integrates SAM with H2A electrolyzer technologies and provides analysts a detailed technoeconomic method to analyze concentrating and photovoltaic solar technologies to produce energy that are directly coupled to LTE and HTSEs that use that energy to split water into hydrogen and oxygen. The baseline hydrogen levelized cost (HLCs) for the GRID-LTE, PV-LTE, CSP-HTSE, and CSP-PV-HTSE systems in Daggett, CA are 2.82, 3.86, 3.68, and 2.90 $\$$USD 2016/kg H2 and 2.50, 2.13, 2.84, 2.15 $\$$USD 2016/kg H2 in the 2020 and 2050 scenarios respectively. To achieve the $\$$2/kg H2 target in locations with excellent solar resources, cost parameters values aligned with aggressive R&D targets will need to be achieved for all the systems configurations. In Daggett, PV costs of $\$$0.68 /Wac or moderate ATB PV CAPEX projections result in HLCs of $\$$2 /kg H2. Similarly for PV-MSALT-HTSE systems, $\$$0.60 /Wac result in $\$$2/kg H2. For the MSALT-HTSE systems, better than aggressive 2050 ATB salt tower CAPEX projections would be needed to reach $\$$2/kg H2. Molten salt tower capital costs of $\$$2400/kW would enable $\$$2/kg H2 in 2050.
This article proposes a nonisolated dc converter-based energy router (dc-ER) and its operating strategy. Here, the intent is to integrate energy storage (ES), distributed generation (DG), local load, and dc power grid in an autonomous and more efficient way. The ES/DG power ports are coupled with each other in partial-type connections, which obtains higher voltage supply gain and direct input–output power transmission. High-voltage supply gain allows a wide solar power tracking range and the possibility of optimal battery charging/discharging. Direct input–output power transmission improves the energy conversion efficiency. In this article, the operating modes of dc-ER are first analyzed, followed by the optimal hardware design counting the DG current ripple minimization and the limitation caused by the power flow direction. Second, the mathematical model of dc-ER is deduced. The hierarchical control is then proposed to manage port energy in a flexible manner. The stability is analyzed by using impedance modeling. Finally, experimental and simulation results verify the superiorities of the proposed topology in terms of flexible operating mode transition and high-power conversion efficiency.
The value of improving wind power forecasting accuracy at different electricity market operation timescales was analyzed by simulating the IEEE 118-bus test system as modified to emulate the generation mixes of the Midcontinent, California, and New England independent system operator balancing authority areas. The wind power forecasting improvement methodology and error analysis for the data set were elaborated. Production cost simulation was conducted on the three emulated systems with a total of 480 scenarios, considering the impacts of different generation technologies, wind penetration levels, and wind power forecasting improvement timescales. The static operational flexibility of the three systems was compared through the diversity of generation mix, the percentage of must-run baseload generators, as well as the available ramp rate and the minimum generation levels. The dynamic operational flexibility was evaluated by the real-time upward and downward ramp capacity. Simulation results show that the generation resource mix plays a crucial role in evaluating the value of improved wind power forecasting at different timescales. In addition, the changes in annual operational electricity generation costs were mostly influenced by the dominant resource in the system. Lastly, the impacts of pumped-storage resources, generation ramp rates, and system minimum generation level requirements on the value of improved wind power forecasting were also analyzed.