Search NASA⌕ Search

SEARCH · Search NASA

Results for “heating systems”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Recovery act: development of design and simulation tool for hybrid geothermal heat pump system

The ground source heat pump (GSHP) system is one of the most energy efficient HVAC technologies in the current market. However, the heat imbalance may degrade the ability of the ground loop heat exchanger (GLHX) to absorb or reject heat. The hybrid GSHP system, which combines a geothermal well field with a supplemental boiler or cooling tower, can balance the loads imposed on the ground loop heat exchangers to minimize its size while retaining superior energy efficiency. This paper presents a recent simulation-based study with an intention to compare multiple common control strategies used in hybrid GSHP systems, including fixed setpoint, outside air reset, load reset, and wetbulb reset. A small office in Oklahoma City conditioned by a hybrid GSHP system was simulated with the latest version of eQUEST 3.7[1]. The simulation results reveal that the hybrid GSHP system has the excellent capability to meet the cooling and heating setpoints during the occupied hours, balance thermal loads on the ground loop, as well as improve the thermal comfort of the occupants with the undersized well field.

15 GEOTHERMAL ENERGY↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Space shuttle/food system study. Volume 2, Appendix A: Active heating system-screening analysis. Appendix B: Reconstituted food heating techniques analysis

Technical data are presented which were used to evaluate active heating methods to be incorporated into the space shuttle food system design, and also to evaluate the relative merits and penalties associated with various approaches to the heating of rehydrated food during space flight. Equipment heating candidates were subject to a preliminary screening performed by a selection rationale process which considered the following parameters; (1) gravitational effect; (2) safety; (3) operability; (4) system compatibility; (5) serviceability; (6) crew acceptability; (7) crew time; (8) development risk; and (9) operating cost. A hot air oven, electrically heated food tray, and microwave oven were selected for further consideration and analysis. Passive, semi-active, and active food preparation approaches were also studied in an effort to determine the optimum method for heating rehydrated food. Potential complexity, cost, vehicle impact penalties, and palatability were considered in the analysis. A summary of the study results is provided along with cost estimates for each of the potential sytems

Source record↗

Carbon nanotube heat-exchange systems

A carbon nanotube heat-exchange system (10) and method for producing the same. One embodiment of the carbon nanotube heat-exchange system (10) comprises a microchannel structure (24) having an inlet end (30) and an outlet end (32), the inlet end (30) providing a cooling fluid into the microchannel structure (24) and the outlet end (32) discharging the cooling fluid from the microchannel structure (24). At least one flow path (28) is defined in the microchannel structure (24), fluidically connecting the inlet end (30) to the outlet end (32) of the microchannel structure (24). A carbon nanotube structure (26) is provided in thermal contact with the microchannel structure (24), the carbon nanotube structure (26) receiving heat from the cooling fluid in the microchannel structure (24) and dissipating the heat into an external medium (19).

42 ENGINEERING↗

Final Report, Materials for Industrial Heat Recovery Systems, Tasks 3 and 4 Materials for Heat Recovery in Recovery Boilers

The DOE-funded project on materials for industrial heat recovery systems included four research tasks: materials for aluminum melting furnace recuperator tubes, materials and operational changes to prevent cracking and corrosion of the co-extruded tubes that form primary air ports in black liquor recovery boilers, the cause of and means to prevent corrosion of carbon steel tubes in the mid-furnace area of recovery boilers, and materials and operational changes to prevent corrosion and cracking of recovery boiler superheater tubes. Results from studies on the latter two topics are given in this report while separate reports on results for the first two tasks have already been published. Accelerated, localized corrosion has been observed in the mid-furnace area of kraft recovery boilers. This corrosion of the carbon steel waterwall tubes is typically observed in the vicinity of the upper level of air ports where the stainless clad co-extruded wall tubes used in the lower portion of the boiler are welded to the carbon steel tubes that extend from this transition point or “cut line” to the top of the boiler. Corrosion patterns generally vary from one boiler to another depending on boiler design and operating parameters, but the corrosion is almost always found within a few meters of the cut line and often much closer than that. This localized corrosion results in tube wall thinning that can reach the level where the integrity of the tube is at risk. Collection and analysis of gas samples from various areas near the waterwall surface showed reducing and sulfidizing gases were present in the areas where corrosion was accelerated. However, collection of samples from the same areas at intervals over a two year period showed the gaseous environment in the mid-furnace section can cycle between oxidizing and reducing conditions. These fluctuations are thought to be due to gas flow instabilities and they result in an unstable or a less protective scale on the carbon steel tubes. Also, these fluctuating air flow patterns can result in deposition of black liquor on the wall tubes, and during periods when deposition is high, there is a noticeable increase in the concentrations of sulfur-bearing gases like hydrogen sulfide and methyl mercaptan. Laboratory studies have shown that chromized and aluminized surface treatments on carbon steel improve the resistance to sulfidation attack. Studies of superheater corrosion and cracking have included laboratory analyses of cracked tubes, laboratory corrosion studies designed to simulate the superheater environment and field tests to study the movement of superheater tubes and to expose a corrosion probe to assess the corrosion behavior of alternate superheater alloys, particularly alloys that would be used for superheaters operating at higher temperatures and higher pressures than most current boilers. In the laboratory corrosion studies, samples of six alternate materials were immersed in an aggressive, low melting point salt mixture and exposed for times up to 336 h, at temperatures of 510, 530 or 560°C in an inert or reactive cover gas. Using weight change and results of metallographic examination, the samples were graded on their resistance to the various environments. For the superheater corrosion probe studies, samples of the same six materials were exposed on an air-cooled corrosion probe exposed in the superheater section of a recovery boiler for 1000 h. Post exposure examination showed cracking and/or subsurface attack in the samples exposed at the higher temperatures with the attack being more severe for samples 13 exposed above the first melting temperature of the deposits that collected on the superheater tubes. From these superheater studies, a ranking was developed for the six materials tested. The task addressing cracking and corrosion of primary air port tubes that was part of this project produced results that have been extensively implemented in recovery boilers in North America, the Nordic countries and many other parts of the world. By utilizing these results, boilers are being operated under more demanding conditions with fewer outages and reduced safety concerns about boiler explosions resulting from failed tubes in the lower boiler. The results of studies on the mid-furnace tube corrosion task and the superheater corrosion and cracking task have become available much more recently, and, consequently, the extent of implementation is far more limited. However, boiler operators are utilizing some of the operational information to minimize corrosion in the mid-furnace area. With construction of new boilers that are designed to operate at higher temperatures and pressures, the guidance on selection of superheater tube materials will almost certainly influence the selection of materials for the more critical areas of the superheaters.

36 MATERIALS SCIENCE↗

Novel concept for detection of a fluid flow fault in a pumped fluid heat rejection system

A pumped fluid heat rejection system (HRS) requires continuous flow of the working fluid to ensure that the components controlled by the HRS stay within their allowable temperature limits. An interruption of flow could result in violations of hardware qualification limits and mission failure. Some of these violations can happen within a few hours. Hence, quick detection of a flow fault to invoke mitigation measures is very critical. In typical pumped fluid HRS, dual or triple pumps are employed to switch the backup units in case the primary unit were to fail. The key metric for the selection of a fault detection system is that it should detect the fault much before the fault’s impact on the thermal health of the HRS controlled components is realized. A trade study was conducted to select such a system for the Europa Clipper Mission to Europa, a moon of Jupiter that is planned for a launch in 2023. Out of the several concepts studied, the most attractive one was a novel and simple concept that uses a low power film heater attached to a section of the HRS tubing. While the fluid flows at its nominal rate, the high thermal coupling of the flowing fluid leads to the tube being close to the fluid’s temperature. However, when the flow stops, the heater warms the small thermal mass of the tubing to a high temperature in a short span of time (~15 minutes). This large temperature rise would then imply that the flow must have stopped. This paper will describe the various concepts considered, the chosen concept, its implementation, and the results of developments tests to validate its performance.

Schmidt, Tyler↗

Electrocaloric heat transfer system

Disclosed is a heat transfer system with a module that includes a peripheral frame (10) and an electrocaloric element (46) disposed in an opening in the peripheral frame. The electrocaloric element includes an electrocaloric film (46), a first electrode (48) on a first side of the electrocaloric film, and a second electrode (50) on a second side of the electrocaloric film. First and second electrically conductive elements (24, 25) are disposed adjacent to first and second surfaces of the peripheral frame, and provide an electrical connection to the first and second electrodes.

Xie, Wei↗

Compressor system with heat recovery

A system includes a first working fluid compressor configured to pressurize a working fluid, and a prime mover coupled to the first working fluid compressor and configured to provide a mechanical input into the first working fluid compressor. An exhaust assembly is coupled to the prime mover and is configured to receive exhaust heat from the prime mover, the exhaust assembly including a generator configured to generate electric current based on the exhaust heat received by the exhaust assembly. A second working fluid compressor includes an electric motor electrically and synchronously coupled to the generator and configured to pressurize the working fluid.

Torrey, David Allan↗

Mutual Influence of Capillary Pumps in Heat-Pipe Systems with Different Evaporator Loads

Thermal management systems that are not hermetically sealed have been developed for use in spacecraft; in such systems, scientific equipment and instruments operate in open space. Accordingly, new methods of thermal regulation have been developed: axial and loop heat pipes; and honeycomb thermal panels with embedded axial heat pipes. Heat transfer in heating systems with heat pipes is based on evaporation and condensation in a two-phase loop. The working fluid moves under the action mainly of capillary forces that appear in capillary channels or honeycomb structures for axial heat pipes and in the porous heated medium (capillary pump) of the loop heat pipes.

42 ENGINEERING↗

Energy Analysis of Combi Heat Pump System Configurations for Space Conditioning and Domestic Hot Water Heating in Residential Buildings

Combi heat pump systems, also referred to multifunctional variable refrigerant flow heat recovery (MF-VRFHR) systems, are specifically designed for residential applications to manage both space conditioning and domestic hot water (DHW). They have attracted attention due to their potential for energy conservation through heat recovery. The incorporation of a hot water tank introduces various system configurations, each characterized by distinct pros and cons related to energy efficiency, system stability, and maintenance. Despite this, a critical gap exists as the specific energy performance remains unquantified under diverse operational modes (e.g., heating mode and heat recovery mode). This paper aims to bridge this gap by conducting a comprehensive comparative analysis of two prevalent system configurations while considering feasible proposed control logics. Configuration 1 integrates a separate hot water tank and a refrigerant-to-water heat exchanger (HEX), also known as a Hydro Kit while Configuration 2 incorporates a refrigerant-wrapped hot water tank. To facilitate this analysis, we developed high-fidelity system models for both configurations in Modelica, capturing system dynamics and detailed control sequences effectively. These system models were built upon the TIL library for HVAC equipment components and the Buildings library for residential building thermal load calculations. The validation of the simulation testbed utilized data from experiments conducted in the PNNL lab home for Configuration 1. To establish the simulation testbed for Configuration 2, we extended the modeling setup derived from Configuration 1. This extension specifically involved substituting the separate hot water tank and Hydro Kit with a refrigerant-wrapped hot water tank of similar sizing sourced from an actual product. The simulation analysis of heating-only and heat recovery modes reveals that Configuration 2 not only saves energy and maintains warmer tank temperatures but also demonstrates faster water heating capabilities. This is attributed to decreased energy loss and improved heat transfer. The study encompasses a wide range of scenarios, considering diverse thermal loads and water usage patterns across heating and heat recovery modes. Overall, the comprehensive results indicate that Configuration 2 achieves energy savings ranging from 3.5% to 12.2% compared to Configuration 1, depending on factors such as water usage patterns, thermal loads, and operational modes.

Configuration, Comparison, Multi-functional, Resid↗

Experimental solar heating-cooling system model tests of a full-scale building system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable - heating and/or cooling load of a building, collected solar energy - with experimental equipment. The system model was based on the loads and components used in the Solar Building Test Facility (SBTF) which includes a 1394 square meter solar collector field, at NASA-Langley. Operations covered 5 continuous days under summer conditions. For the system model, up to 55% of the simulated collected solar energy was used for the building load. This amount constituted 35% of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, 75% of the collected solar energy would be used. This amount would supply approximately 50% of the building cooling load.

Namkoong, D.↗

Tests of a reduced-scale experimental model of a building solar heating-cooling system

An experimental solar heating and cooling system model has been built and operated, combining elements that are programmable (e.g., heating and cooling load of a building and collected solar energy) with experimental equipment. The experimental system model was based on the loads and components used in the Solar Building Test Facility (SBTF), which includes a 1394 sq m solar collector field at NASA Langley. These tests covered 5 continuous days under summer conditions. For the system model up to 55 percent of the simulated collected solar energy was used for the building load. This amount of solar energy supplied 35 percent of the building cooling load. Heat loss was significant. If tank heat loss were eliminated, which would make it similar to the actual SBTF, 75 percent of the collected solar energy would be used. This amount would supply approximately 50 percent of the building cooling load. A higher fraction of solar energy is possible with a more performance-optimized system.

Namkoong, D.↗

A simulation-based study on different control strategies for variable speed pump in distributed ground source heat pump systems

Most commercial ground source heat pump systems (GSHP) in the United States are in a distributed configuration. These systems circulate water or an anti-freeze solution through multiple heat pump units via a central pumping system, which usually uses variable speed pump(s). Variable speed pumps have potential to significantly reduce pumping energy use; however, the energy savings in reality could be far away from its potential due to improper pumping system design and controls. In this paper, a simplified hydronic pumping system was simulated with the dynamic Modelica models to evaluate three different pumping control strategies. This includes two conventional control strategies, which are to maintain a constant differential pressure across either the supply and return mains, or at the most hydraulically remote heat pump; and an innovative control strategy, which adjusts system flow rate based on the demand of each heat pump. The simulation results indicate that a significant overflow occurs at part load conditions when the variable speed pump is controlled to main a constant differential pressure across the supply and return mains of the piping system. On the other hand, an underflow occurs at part load conditions when the variable speed pump is controlled to maintain a constant differential pressure across the furthest heat pump. The flow-demand-based control can provide needed flow rate to each heat pump at any given time, and with less pumping energy use than the two conventional controls. Finally, a typical distributed GSHP system was studied to evaluate the energy saving potential of applying the flow-demand-based pumping control strategy. This case study shows that the annual pumping energy consumption can be reduced by 62% using the flow-demand-based control compared with that using the conventional pressure-based control to maintain a constant differential pressure a cross the supply and return mains.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Cryogenic Heat Transfer System

Disclosed herein is a cryogenic heat transfer system capable of transferring 50 W or more at cryogenic temperatures of 100.degree. K or less for use with cryocooler systems. In an embodiment, a cryogenic heat transfer system comprises a refrigerant contained within an inner chamber bound by a condenser in fluid communication with an evaporator through at least one flexible conduit, the condenser in thermal communication with the cold station of a cryocooler, and the evaporator positionable in thermal communication with a heat source, typically a radiation shield of a cryogenic chamber. A process to remove heat from a cryogenic chamber is also disclosed.

Chui, Talso C.↗