Search NASA⌕ Search

SEARCH · Search NASA

Results for “high precision”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Precision Measurement of the W Mass

Using proton-antiproton collision data corresponding to an integrated luminosity of 8.8 fb-1 collected in Tevatron Run 2, CDF performed a high precision measurement of the W mass. This result, 80433.5±6.4±6.9 MeV, is the most precise so far, and shows a discrepancy of 76 with Standard Model expectations.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A self-supervised robotic system for autonomous contact-based spatial mapping of semiconductor properties

Integrating robotically driven contact-based material characterization techniques into self-driving laboratories can enhance measurement quality, reliability, and throughput. While deep learning models support robust autonomy, current methods lack reliable pixel-precision positioning and require extensive labeled data. To overcome these challenges, we propose an approach for building self-supervised autonomy into contact-based robotic systems that teach the robot to follow domain expert measurement principles at high throughputs. We demonstrate the performance of this approach by autonomously driving a 4-DOF robotic probe for 24 hours to characterize semiconductor photoconductivity at 3025 uniquely predicted poses across a gradient of drop-casted perovskite film compositions, achieving throughputs of more than 125 measurements per hour. Spatially mapping photoconductivity onto each drop-casted film reveals compositional trends and regions of inhomogeneity, valuable for identifying manufacturing defects. With this self-supervised neural network–driven robotic system, we enable high-precision and reliable automation of contact-based characterization techniques at high throughputs, thereby allowing measurement of previously inaccessible yet important semiconductor properties for self-driving laboratories.

Science & Technology - Other Topics↗

Precision-controlled ultrafast electron microscope platforms. A case study: Multiple-order coherent phonon dynamics in 1T-TaSe2 probed at 50 fs–10 fm scales

We report on the first detailed beam tests attesting the fundamental principle behind the development of high-current-efficiency ultrafast electron microscope systems where a radio frequency (RF) cavity is incorporated as a condenser lens in the beam delivery system. To allow for the experiment to be carried out with a sufficient resolution to probe the performance at the emittance floor, a new cascade loop RF controller system is developed to reduce the RF noise floor. Temporal resolution at 50 fs in full-width-at-half-maximum and detection sensitivity better than 1% are demonstrated on exfoliated 1T-TaSe2 system under a moderate repetition rate. To benchmark the performance, multi-terahertz edge-mode coherent phonon excitation is employed as the standard candle. The high temporal resolution and the significant visibility to very low dynamical contrast in diffraction signals via high-precision phase-space manipulation give strong support to the working principle for the new high-brightness femtosecond electron microscope systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Calibration-free analysis of Li isotope ratios using laser ablation and laser absorption spectroscopy

We introduce a rapid, calibration-free, all-optical method for high-precision lithium isotope ratio measurements in solid materials using laser ablation combined with tunable laser absorption spectroscopy. A new asynchronous acquisition method is used to acquire time-resolved, high-resolution spectra of the 6Li and 7Li D1 and D2 transitions near 671 nm. Isotope ratios and atomic column densities are extracted from measured spectra via a physics-based fitting model including hyperfine structure. Under 1 Torr air, spectra recorded = 0.75 ms after plasma onset exhibit narrow linewidths corresponding to Doppler temperatures = 400 K, enabling resolution of the isotope peaks with high signal-to-noise ratios. Analysis of LiAlO2 samples with varying 6Li:7Li ratios demonstrates isotopic precisions of 0.6–1.7% for spectra acquired in 30 s. Isotope ratios determined from the spectral fits show accuracy within –0.3% to –1.7% of reference ICP-MS measurements without requiring calibration to external standards. By eliminating sample preparation and enabling spatially resolved isotopic mapping, this method offers a rapid analysis approach to lithium isotope determination in solid materials relevant to nuclear energy, safeguards, and geochemistry.

Phillips, Mark C.↗

Review on robot-assisted polishing: Status and future trends

Nowadays, precision components have been extensively used in various industries such as biomedicine, photonics, and optics. To achieve nanometric surface roughness, high-precision polishing is mandatory. Compared with the conventional polishing techniques, the robot-assisted polishing has the advantages of flexible working ranges and low cost. Therefore, it has been more widely deployed in demanding polishing tasks. However, few review articles were found on this topic to provide a general progress on the development of the robot-assisted polishing technology. Here in this paper reviews the recent advancement of the robot-assisted polishing. Firstly, the integration of robots with various polishing techniques is overviewed, followed by the introduction of the research status of constant force control in robot-assisted polishing. Then, the errors in typical robot-assisted polishing systems are analyzed, together with the corresponding compensation methods. At last, the future trends in the development of robot-assisted polishing are discussed. This review is intended as a roadmap for researchers or engineers who are interested in robot-assisted polishing or machining.

36 MATERIALS SCIENCE↗

Multi-orbital-phase and Multiband Characterization of Exoplanetary Atmospheres with Reflected Light Spectra

Direct imaging of widely separated exoplanets from space will obtain their reflected light spectra and measure atmospheric properties. Previous calculations have shown that a change in the orbital phase would cause a spectral signal, but whether this signal may be used to characterize the atmosphere has not been shown. We simulate starshade-enabled observations of the planet 47 UMa b, using the present most realistic simulator Starshade Imaging Simulation Toolkit for Exoplanet Reconnaissance to estimate the uncertainties due to residual starlight, solar glint, and exozodiacal light. We then use the Bayesian retrieval algorithm ExoReL{sup R} to determine the constraints on the atmospheric properties from observations using a Roman- or Habitable Exoplanet Observatory (HabEx)-like telescope, comparing the strategies to observe at multiple orbital phases or in multiple wavelength bands. With a ∼20% bandwidth in 600–800 nm on a Roman-like telescope, the retrieval finds a degenerate scenario with a lower gas abundance and a deeper or absent cloud than the truth. Repeating the observation at a different orbital phase or at a second 20% wavelength band in 800–1000 nm, with the same integration time and thus degraded signal-to-noise ratio (S/N), would effectively eliminate this degenerate solution. Single observation with a HabEx-like telescope would yield high-precision constraints on the gas abundances and cloud properties, without the degenerate scenario. These results are also generally applicable to high-contrast spectroscopy with a coronagraph with a similar wavelength coverage and S/N, and can help design the wavelength bandwidth and the observation plan of exoplanet direct-imaging experiments in the future.

79 ASTRONOMY AND ASTROPHYSICS↗

Diagnostic Systems in the Muon $g-2$ experiment at Fermilab

The muon anomalous magnetic moment, $a_\mu=\frac{g-2}{2}$, is a low-energy observable which can be both measured and computed to high precision, making it a sensitive test of the Standard Model and a probe for new physics. This anomaly was measured with a precision of $0.20$~parts per million (ppm) by the Fermilab's Muon g-2 (E989) experiment. The final goal of the E989 experiment is to reach a precision of $0.14$~ppm. The experiment is based on the measurement of the muon spin anomalous precession frequency, $\omega_a$, based on the arrival time distribution of high-energy decay positrons observed by 24 electromagnetic calorimeters, placed around the inner circumference of a $14$~m diameter storage ring, and on the precise knowledge of the storage ring magnetic field and of the beam time and space distribution. Achieving this level of precision requires strict control over systematics, which is ensured through several diagnostic devices. At the accelerator level, these devices monitor the quality of the injected beam (e.g., verifying that it has the correct momentum), while at the detector level, they track both the magnetic field and the gain of the calorimeters. In this work the devices and techniques used by the E989 experiment will be presented.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Road to PROSPECT-II

The Precision Reactor Oscillation and SPECTrum (PROSPECT) experiment is based in a segmented liquid scintillator antineutrino detector situated approximately 7 meters from the highly enriched High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory. Its main goal is to investigate short-baseline antineutrino oscillations. The first phase of data collection, known as PROSPECT-I, was held from 2018 to 2019 and was used for several high-precision analyses, including multiple measurements of the $^{235}U$ antineutrino spectrum and searches for $eV$-scale sterile antineutrino oscillations. The collaboration is now preparing for the second phase, PROSPECT-II, which features an upgraded detector design. This advancement will enhance sensitivity and statistical power, allowing for a broader range of analyses beyond those achieved in PROSPECT-I. As we transition into this new phase, new questions have arisen concerning background simulation and its potential differences from those conducted during the initial phase of the experiment. Moreover, it is essential to ascertain, through simulations, the positive effects that an improved detector could have on the study of oscillations. This information is crucial for justifying the proposed enhancements, and I will cover all of this in the talk.

43 PARTICLE ACCELERATORS↗

Report of the Frontier for Rare Processes and Precision Measurements

This is the Snowmass 2021 Rare and Precision Frontier Report. The Rare Processes and Precision Measurements Frontier, referred to as the ``Rare and Precision Frontier", or RPF, encompasses searches for extremely rare processes or tiny deviations from the Standard Model (SM) that can be studied with intense sources and high-precision detectors. Our community studies have identified several unique research opportunities that may pin down the scales associated with New Physics (NP) interactions and constrain the couplings of possible new degrees of freedom. Searches for rare flavor transition processes and precision measurements are indispensable probes of flavor and fundamental symmetries, and provide insights into physics that manifests itself at higher energy or through weaker interactions than those directly accessible at high-energy colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A measurement of proton-carbon forward scattering in a proof-of-principle test of the EMPHATIC spectrometer

The next generation of long-baseline neutrino experiments will be capable of precision measurements of neutrino oscillation parameters, precision neutrino-nucleus scattering, and unprecedented sensitivity to physics beyond the Standard Model. Reduced uncertainties in neutrino fluxes are necessary to achieve high precision and sensitivity in these future precise neutrino measurements. New measurements of hadron-nucleus interaction cross sections are needed to reduce uncertainties of neutrino fluxes. We report measurements of the differential cross-section as a function of scattering angle for proton-carbon interactions with a single charged particle in the final state at beam momenta of 20, 30, and 120 GeV/c. These measurements are the result of a beam test for EMPHATIC, a hadron-scattering and hadron-production experiment. The total, elastic and inelastic cross-sections are also extracted from the data and compared to previous measurements. These results can be used in current and future long-baseline neutrino experiments, and demonstrate the feasibility of future measurements by an upgraded EMPHATIC spectrometer.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Interferometric measurements of refractive index and dispersion at high pressure

Abstract We describe a high precision interferometer system to measure the pressure dependence of the refractive index and its dispersion in the diamond anvil cell (DAC). The reflective Fabry–Perot fringe patterns created by both a white light and a monochromatic beam are recorded to determine both the sample thickness and its index at the laser wavelength and to characterize the dispersion in the visible range. Advances in sample preparation, optical setup, and data analysis enable us to achieve $$10^{-4}$$ 10 - 4 random uncertainty, demonstrated with an air sample, a factor of five improvement over the best previous DAC measurement. New data on $${\text{H}}_{2}\text{O}$$ H 2 O liquid water and ice VI up to 2.21 GPa at room temperature illustrate how higher precision measurements of the index and its optical dispersion open up new opportunities to reveal subtle changes in the electronic structure of water at high pressure.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Measurement of inclusive electrons from open heavy-flavor hadron decays in p + p collisions at s = 200 GeV with the STAR detector

We report a new measurement of the production cross section for inclusive electrons from open heavy-flavor hadron decays as a function of transverse momentum (p T ) at midrapidity (|y| < 0.7) in p + p collisions at √s = 200 GeV. Overall, the result is presented for 2.5 < P T < 10 GeV/c with an improved precision above 6 GeV/c with respect to the previous measurements, providing more constraints on perturbative QCD calculations. Moreover, this measurement also provides a high-precision reference for measurements of nuclear modification factors for inclusive electrons from open-charm and -bottom hadron decays in heavy-ion collisions.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Spin Structure Program at Jefferson Lab

High performance polarized beam and targets at JLab enabled an extensive program to measure nucleon spin structure functions with high precision. This talk will highlight the recent JLab spin experiments, including the measurement of the neutron spin asymmetry (A1n) in the valance quark (high-x) region and the measurement of the neutron spin moment d2 in medium-high Q2 region to study quark-gluon correlations. Recent results on spin moments at low Q2 (spin sum rules and spin polarizabilities) for both the proton and neutron will also be presented

Chen, Jian-Ping↗

Vexcel Imaging's Suitability for Automatic Verification

Accurate, independently verified geospatial data is essential for automated calibration, validation, and operational decision-making. This study evaluated the positional accuracy of Vexcel Imaging™’s UltraCam® Osprey imagery (7.5 cm GSD) using globally distributed Continuously Operating Reference Stations (CORS) as independent control. Despite manufacturer claims of 15 cm horizontal accuracy, residual errors were consistently one to two orders of magnitude larger, with no subset of imagery meeting precision thresholds. These discrepancies cannot be explained by normal photogrammetric or environmental factors and raise concerns about the reliability of the imagery for high-precision tasks. The results demonstrate that Vexcel imagery, in its current form, is unsuitable for workflows requiring rigorous spatial accuracy or automated verification. At the same time, the reproducible validation framework developed in this study establishes a scalable method for assessing commercial imagery, ensuring that future products can be independently and objectively verified before operational adoption.

47 OTHER INSTRUMENTATION↗

Muon Campus at Fermilab

The Muon Campus at Fermilab provides world class accelerator infrastructure supporting the next generation intensity frontier experiments. The anti-proton source from the Tevatron era was converted to the present day Muon Campus at the end of the collider program in 2011. Currently, the Muon Campus delivers highly polarized muon beams to the Muon g-2 experiment and in a few years, it will provide muon beams to the Mu2e experiment. The Muon g-2 experiment is a high precision test of the standard model; it is precise enough to measure QED, Weak, and QCD Standard Model contributions.The Muon g-2 experiment looks for a significant deviation from the Standard Model whereas the Mu2e experiment looks for rare processes using high intensity muon beams. The Muon g-2 experiment has measured the anomalous magnetic moment of muons to an unprecedented 460 ppb precision with Run 1 data. The experiment has completed 5 runs, accumulating 19$\times$ Brookhaven E821 data set. The Mu2e experiment has completed the construction phase and first beam to the Diagnostic Absorber was run on April 14, 2022. Installation and commissioning of the Mu2e experiment will begin in 2023 and beam commissioning and physics run is currently planned for 2026.

43 PARTICLE ACCELERATORS↗

Precision measurement of the electron energy-loss function in tritium and deuterium gas for the KATRIN experiment

Abstract The KATRIN experiment is designed for a direct and model-independent determination of the effective electron anti-neutrino mass via a high-precision measurement of the tritium $$\upbeta $$ β -decay endpoint region with a sensitivity on $$m_\nu $$ m ν of 0.2 $$\hbox {eV}/\hbox {c}^2$$ eV / c 2 (90% CL). For this purpose, the $$\upbeta $$ β -electrons from a high-luminosity windowless gaseous tritium source traversing an electrostatic retarding spectrometer are counted to obtain an integral spectrum around the endpoint energy of 18.6 keV. A dominant systematic effect of the response of the experimental setup is the energy loss of $$\upbeta $$ β -electrons from elastic and inelastic scattering off tritium molecules within the source. We determined the energy-loss function in-situ with a pulsed angular-selective and monoenergetic photoelectron source at various tritium-source densities. The data was recorded in integral and differential modes; the latter was achieved by using a novel time-of-flight technique. We developed a semi-empirical parametrization for the energy-loss function for the scattering of 18.6-keV electrons from hydrogen isotopologs. This model was fit to measurement data with a 95% $$\hbox {T}_2$$ T 2 gas mixture at 30 K, as used in the first KATRIN neutrino-mass analyses, as well as a $$\hbox {D}_2$$ D 2 gas mixture of 96% purity used in KATRIN commissioning runs. The achieved precision on the energy-loss function has abated the corresponding uncertainty of $$\sigma (m_\nu ^2)< {{10}^{-2}}{\hbox {eV}^{2}}$$ σ ( m ν 2 ) < 10 - 2 eV 2 [1] in the KATRIN neutrino-mass measurement to a subdominant level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The NuMI Flux Prediction at ICARUS

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long-baseline neutrino oscillation experiment seeking to probe fundamental symmetries within the structure of the Pontecorvo-Maki-Nakagawa-Sakata (PMNS) mixing matrix, and perform precision measurements its parameters including the neutrino mass ordering via the sign of $\Delta m^2_{31}$, and the charge-parity violating phase, $\delta_{CP}$. To make these measurements with high precision, DUNE will require external $\nu$-Ar scattering cross section data as a crucial input to the oscillation fit. Imaging Cosmic And Rare Underground Signals (ICARUS) is a 476 t liquid argon neutrino detector located at Fermi National Accelerator Laboratory (FNAL) where it is serving as the far detector for the Short-Baseline Neutrino (SBN) program along the Booster Neutrino Beam (BNB) axis. ICARUS additionally lies 795 m downstream and 100.1 mrad off-axis of the Neutrinos at the Main Injector (NuMI) neutrino beam. From this position, ICARUS is exposed to a large flux of NuMI (anti-)electron and (anti-)muon neutrinos, and poses a unique opportunity to provide high-statistics measurements of quasi-elastic and single pion-production cross sections for four neutrino flavors ($\nu_{\mu}$, $\nu_{e}$, $\bar{\nu}_{\mu}$, $\bar{\nu}_{e}$). This dissertation is centered around accurately characterizing the models and estimating their precision for use in making these measurements. This includes identifying major sources of uncertainty in the models such that they can be properly propagated to the cross section measurements. Specifically, this work focused on the model of the NuMI beamline and its impact on the neutrino fluxes, but also delved into the detector response model and its impact on reconstructed observables in the detector. Significant efforts were made to improve the characterization to enhance precision and thus reduce the level of propagated uncertainty. In particular, the NuMI flux was determined to be composed of 57% $\nu_{\mu}$, 38% $\bar{\nu}_{\mu}$, 3% $\nu_{e}$, and 2% $\bar{\nu}_{e}$ while the horns are operating in the positive-particle focusing configuration. The total uncertainty on the $\nu_{\mu} + \bar{\nu}_{\mu}$ ($\nu_{e} + \bar{\nu}_{e}$) flux while operating in the forward horn operating mode was determined to be 10.84% (9.04%). Compared to the on-axis flux, mesons that eventually decay to neutrinos more frequently reinteract within the NuMI structure, resulting in elevated uncertainty as these processes are not well-constrained by existing hadron interaction cross section measurements. Covariance matrices were calculated to propagate the flux uncertainty characterization to NuMI analyses.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗