Search NASA⌕ Search

SEARCH · Search NASA

Results for “high spatial resolution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

High-Resolution PET Detector. Final report

The objective of this project was to develop an understanding of the limits of performance for a high resolution PET detector using an approach based on continuous scintillation crystals rather than pixelated crystals. The overall goal was to design a high-resolution detector, which requires both high spatial resolution and high sensitivity for 511 keV gammas. Continuous scintillation detectors (Anger cameras) have been used extensively for both single-photon and PET scanners, however, these instruments were based on NaI(Tl) scintillators using relatively large, individual photo-multipliers. In this project we investigated the potential of this type of detector technology to achieve higher spatial resolution through the use of improved scintillator materials and photo-sensors, and modification of the detector surface to optimize the light response function.We achieved an average spatial resolution of 3-mm for a 25-mm thick, LYSO continuous detector using a maximum likelihood position algorithm and shallow slots cut into the entrance surface.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-G-BRB-10: New Generation of High Frame-Rate and High Spatial-Resolution EPID QA System for Full-Body MLC-Based Robotic Radiosurgery

Purpose: To systematically investigate an ultra-high spatial-resolution amorphous silicon flat-panel electronic portal imaging device (EPID) for MLC-based full-body robotic radiosurgery geometric and dosimetric quality assurance (QA). Methods: The high frame-rate and ultra-high spatial resolution EPID is an outstanding detector for measuring profiles, MLC-shaped radiosurgery field aperture verification, and small field dosimetry. A Monte Carlo based technique with a robotic linac specific response and calibration is developed to convert a raw EPID-measured image of a radiosurgery field into water-based dose distribution. The technique is applied to measure output factors and profiles for 6MV MLC-defined radiosurgery fields with various sizes ranging from 7.6mm×7.7mm to 100mm×100.1mm and the results are compared with the radiosurgery diode scan measurements in water tank. The EPID measured field sizes and the penumbra regions are analyzed to evaluate the MLC positioning accuracy. Results: For all MLC fields, the EPID measured output factors of MLC-shaped fields are in good agreement with the diode measurements. The mean output difference between the EPID and diode measurement is 0.05±0.87%. The max difference is −1.33% for 7.6mm×7.7mm field. The MLC field size derived from the EPID measurements are in good agreement comparing to the diode scan result. For crossline field sizes, the mean difference is −0.17mm±0.14mm with a maximum of −0.35mm for the 30.8mm×30.8mm field. For inline field sizes, the mean difference is +0.08mm±0.18mm with a maximum of +0.45mm for the 100mm×100.1mm field. The high resolution EPID is able to measure the whole radiation field, without the need to align the detector center perfectly at field center as diode or ion chamber measurement. The setup time is greatly reduced so that the whole process is possible for machine and patient-specific QA. Conclusion: The high spatial-resolution EPID is proved to be an accurate and efficient tool for QA of MLC-equipped robotic radiosurgery system.

60 APPLIED LIFE SCIENCES↗

Spatial resolution of a spherical x-ray crystal spectrometer at various magnifications

A high spatial resolution of a few μm is often required for probing small-scale high-energy-density plasmas using high resolution x-ray imaging spectroscopy. This resolution can be achieved by adjusting system magnification to overcome the inherent limitation of the detector pixel size. Laboratory experiments on investigating the relation between spatial resolution and system magnification for a spherical crystal spectrometer are presented. Tungsten Lβ{sub 2} rays from a tungsten-target micro-focus x-ray tube were diffracted by a Ge 440 crystal, which was spherically bent to a radius of 223 mm, and imaged onto an x-ray CCD with 13-μm pixel size. The source-to-crystal (p) and crystal-to-detector (q) distances were varied to produce spatial magnifications (M = q/p) ranging from 2 to 10. The inferred instrumental spatial width reduces with increasing system magnification M. However, the experimental measurement at each M is larger than the theoretical value of pixel size divided by M. Future work will focus on investigating possible broadening mechanisms that limit the spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Application of pan-sharpening algorithm for correlative multimodal imaging using AFM-IR

The coupling of atomic force microscopy with infrared spectroscopy (AFM-IR) offers the unique capability to characterize the local chemical and physical makeup of a broad variety of materials with nanoscale resolution. However, in order to fully utilize the measurement capability of AFM-IR, a three-dimensional dataset (2D map with a spectroscopic dimension) needs to be acquired, which is prohibitively time-consuming at the same spatial resolution of a regular AFM scan. In this paper, we provide a new approach to process spectral AFM-IR data based on a multicomponent pan-sharpening algorithm. This approach requires only a low spatial resolution spectral and a limited number of high spatial resolution single wavenumber chemical maps to generate a high spatial resolution hyperspectral image, greatly reducing data acquisition time. As a result, we are able to generate high-resolution maps of component distribution, produce chemical maps at any wavenumber available in the spectral range, and perform correlative analysis of the physical and chemical properties of the samples. We highlight our approach via imaging of plant cell walls as a model system and showcase the interplay between mechanical stiffness of the sample and its chemical composition. We believe our pan-sharpening approach can be more generally applied to different material classes to enable deeper understanding of that structure-property relationship at the nanoscale.

36 MATERIALS SCIENCE↗

Time stamping of single optical photons with 10 ns resolution

High spatial and temporal resolution are key features for many modern applications, e.g. mass spectrometry, probing the structure of materials via neutron scattering, studying molecular structure, etc. Fast imaging also provides the capability of coincidence detection, and the further addition of sensitivity to single optical photons with the capability of timestamping them further broadens the field of potential applications. Here, photon counting is already widely used in X-ray imaging, where the high energy of the photons makes their detection easier.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Five Micron High Resolution MALDI Mass Spectrometry Imaging with Simple, Interchangeable, Multi-Resolution Optical System

High-spatial resolution mass spectrometry imaging (MSI) is crucial for the mapping of chemical distributions at the cellular and subcellular level. In this work, we improved our previous laser optical system for matrix-assisted laser desorption ionization (MALDI)-MSI, from ~9 μm practical laser spot size to a practical laser spot size of ~4 μm, thereby allowing for 5 μm resolution imaging without oversampling. This is accomplished through a combination of spatial filtering, beam expansion, and reduction of the final focal length. Most importantly, the new laser optics system allows for simple modification of the spot size solely through the interchanging of the beam expander component. Using 10×, 5×, and no beam expander, we could routinely change between ~4, ~7, and ~45 μm laser spot size, in less than 5 min. We applied this multi-resolution MALDI-MSI system to a single maize root tissue section with three different spatial resolutions of 5, 10, and 50 μm and compared the differences in imaging quality and signal sensitivity. We also demonstrated the difference in depth of focus between the optical systems with 10× and 5× beam expanders. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spectroscopic setup for submicrometer-resolution mapping of low-signal absorption and luminescence using photothermal heterodyne imaging and photon-counting techniques

A spectroscopic setup that enables one to map the absorption and photoluminescence with submicrometer spatial resolution and high sensitivity is described. Here a photothermal heterodyne imaging pump/probe technique is employed for absorption mapping, and low-signal, spatially resolved photoluminescence is recorded using photon counting. High-spatial-resolution mapping is accomplished by using high-numerical-aperture microscope objective focusing laser beams (pump and probe) into a submicrometer spot and raster-scanning sample mounted on the nanopositioning translation stage. Performance of the setup is illustrated by mapping absorption and luminescence of the hafnium oxide film with embedded hafnium nanoparticles and multilayer dielectric grating. In both cases submicrometer spatial resolution is demonstrated and possible physical mechanisms leading to image contrast on a submicrometer scale is discussed

47 OTHER INSTRUMENTATION↗

Coronal Heating and the Need for High-Resolution Observations

Despite excellent progress in recent years in understanding coronal heating, there remain many crucial questions that are still unanswered. Limitations in the observations are one important reason. Both theoretical and observational considerations point to the importance of small spatial scales, impulsive energy release, strong dynamics, and extreme plasma nonuniformity. As a consequence, high spatial resolution, broad temperature coverage, high temperature fidelity, and sensitivity to velocities and densities are all critical observational parameters. Current instruments lack one or more of these properties, and this has led to considerable ambiguity and confusion. In this talk, I will discuss recent ideas about coronal heating and emphasize that high spatial resolution observations, especially spectroscopic observations, are needed to make major progress on this important problem.

Klimchuk, James A.↗

Nanoscale Antiferromagnetic Domain Imaging using Full-Field Resonant X-ray Magnetic Diffraction Microscopy

The physical properties of magnetic materials frequently depend not only on the microscopic spin and electronic structures, but also on the structures of mesoscopic length scales that emerge, for instance, from domain formations, or chemical and/or electronic phase separations. However, experimental access to such mesoscopic structures is currently limited, especially for antiferromagnets with net zero magnetization. Here, full-field microscopy and resonant magnetic X-ray diffraction are combined to visualize antiferromagnetic (AF) domains of the spin–orbit Mott insulator Sr 2 IrO 4 with area over ≈0.1 mm 2 and with spatial resolution as high as ≈150 nm. With the unprecedented wide field of views and high spatial resolution, an intertwining of two AF domains on a length comparable to the measured average AF domain wall width of 545 nm is revealed. This mesoscopic structure comprises a substantial portion of the sample surface, and thus can result in a macroscopic response unexpected from its microscopic magnetic structure. In particular, the symmetry analysis presented in this work shows that the inversion symmetry, which is preserved by the microscopic AF order, becomes ill-defined at the mesoscopic length scale. We report this result underscores the importance of this novel technique for a thorough understanding of the physical properties of antiferromagnets.

36 MATERIALS SCIENCE↗

HPC-EPIC for High Resolution Simulations of Environmental and Sustainability Assessment

Multiple concerns over the impact of wide scale changes in land management have motivated comprehensive analyses of environmental sustainability of food and biofuel production. These call for high-resolution, spatial-temporal information of lands using tools that enable comprehensive analyses of natural resources for decision-making. Most agroecosystem simulation models are point models with a user interface that allows users to provide inputs and examine results for agricultural field scale analyses, and they aren’t able to meet the needs of the regional and national simulation with high spatial resolutions. We describe an efficient computational approach over deployment of the Environmental Policy Integrated Climate (EPIC) model at high-resolution scales using a high performance computing (HPC) technique in this study. We concentrate on an integrated procedure for executing millions of simulations required, but also address building databases for model initialization and forcing the simulations, and post-processing model outputs.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

X-ray near-field multi-slice ptychography for in-situ imaging

Abstract In-situ imaging of chemical reactions can provide valuable insight into nanoparticle growth and structural evolution. Hard X-ray imaging is an excellent tool for this purpose, as it combines high spatial resolution with high penetration depth, allowing for realistic reaction environments. While far-field ptychography is a well-established method at synchrotron radiation sources, its near-field analog has received less attention. In this work we show that near-field multi-slice ptychography is a competitive method for high-resolution in-situ imaging by studying the formation of gold nanocages via galvanic replacement. Our work extends near-field X-ray ptychography to sub-50 nm spatial resolution by using multilayer Laue lenses. These high numerical aperture optics enable to distinguish sample layers that are separated by less than 100 µm by multi-slicing techniques.

Science & Technology - Other Topics↗

Optical design of an imaging spectral radiometer for earth resources applications.

Description of the optics, thermal compensation measures, and calibration procedures for a scanning imaging spectroradiometer to be used in earth resources sensing applications. The spectral range covered extends from 4000 to 8500 A. Two possible modes of operation include (1) a high-spatial-resolution terrestrial survey mode with moderate spectral resolution, and (2) a high-spectral-resolution ocean survey mode with decreased spatial resolution. Two high-aperture f/1.4 objective lenses (providing fields of view of 10 and 25 deg) are interchangeable to give added flexibility in planning experiments with this instrument. A diffraction grating disperses the spectrum which is then scanned by the image sensor.

Harris, T. I.↗

Advances in High Resolution Ultrafast Scintillators for Fast timing Applications

Scintillation detectors exhibiting high spatial resolution and fast timing capabilities are of vital importance for synchrotron sources. These detectors may be exposed to a variety of X-ray energies (up to 140 keV) and used in high frame rate applications. Here, we describe the advances in the development of thin-film LuI3:Ce scintillators for higher energy X-ray imaging, with fast timing and high spatial resolution. When grown in a single crystalline form, these scintillators are bright, producing 115 000 photons/MeV. However, to achieve high spatial resolution, these scintillators are grown in thin-film form with a microcolumnar structure, controllable to column diameters of <1-30 mu m. Thus, a much thicker scintillator layer (10 mu m-3 mm or higher) may be grown, providing superior X-ray absorption while achieving high resolutions of 50 mu m or better, at the cost of reduced light yield. To study the timing characteristics of the scintillator, time-resolved X-ray excited optical luminescence (TR-XEOL) was performed on two different sets of three samples of LuI3 at the 1-BM beamline of the Advanced Photon Source at Argonne National Laboratory. Besides, we report timing measurements obtained using a photomultiplier tube (PMT) and oscilloscope at Radiation Monitoring Devices (RMD) Inc. Using the TR-XEOL, we determined the decay constants of LuI3 as a function of Ce doping, recording a fast decay component as low as 3.6 ns (39%), one of the fastest values recorded in inorganic scintillators. This fast decay opens up numerous novel applications, where ultrahigh frame rates are important using synchrotron X-rays. This article will discuss fabrication, characterization, and potential applications for this novel scintillator.

fast timing↗

X-ray Optics Development at MSFC

Development of high resolution focusing telescopes has led to a tremendous leap in sensitivity, revolutionizing observational X-ray astronomy. High sensitivity and high spatial resolution X-ray observations have been possible due to use of grazing incidence optics (paraboloid/hyperboloid) coupled with high spatial resolution and high efficiency detectors/imagers. The best X-ray telescope flown so far is mounted onboard Chandra observatory launched on July 23,1999. The telescope has a spatial resolution of 0.5 arc seconds with compatible imaging instruments in the energy range of 0.1 to 10 keV. The Chandra observatory has been responsible for a large number of discoveries and has provided X-ray insights on a large number of celestial objects including stars, supernova remnants, pulsars, magnetars, black holes, active galactic nuclei, galaxies, clusters and our own solar system.

X-ray optics↗

High-resolution imaging of solar system objects

A very extensive Io sodium imaging program beginning with the first images of the cloud and culminating in comprehensive characterization of the cloud's appearance and behavior as a function of both time and Io's orbital position now forms the basis for a collaborative modeling analysis and a continued observational study with emphasis on understanding how the cloud's behavior is diagnostic of spatial and temporal variations in the physical conditions of the inner Jovian magnetosphere. The sodium cloud was found to have a variety of systematic variations, a pronounced east-west orbital asymmetry, and temporal changes which could be diagnostic of time changes in both Io and its plasma environment. New comet imaging programs initiated at the 3.6-meter Canada-France-Hawaii Telescope draw upon both ultra high time resolution and high spatial resolution imaging capabilities. Seven observing runs between Dec. 1984 and May 1986 were devoted to observing Halley, Giacobini-Zinner, and several other comets. Among these observations were the first images of Halley through IHW filters, and images of Giacobini-Zinner during the ICE encounter which have been directly correlated with ICE magnetic field measurements.

Goldberg, B. A.↗

THE INFRARED NUCLEAR EMISSION OF SEYFERT GALAXIES ON PARSEC SCALES: TESTING THE CLUMPY TORUS MODELS

We present subarcsecond resolution mid-infrared (mid-IR) photometry in the wavelength range from 8 to 20 {mu}m of 18 Seyfert galaxies, reporting high spatial resolution nuclear fluxes for the entire sample. We construct spectral energy distributions (SEDs) that the active galactic nucleus (AGN) dominates, relatively uncontaminated by starlight, adding near-IR measurements from the literature at similar angular resolution. We find that the IR SEDs of intermediate-type Seyferts are flatter and present higher 10 to 18 {mu}m ratios than those of Seyfert 2 galaxies. We fit the individual SEDs with clumpy dusty torus models using the in-house-developed BayesClumpy tool. We find that the clumpy models reproduce the high spatial resolution measurements. Regardless of the Seyfert type, even with high spatial resolution data, near- to mid-IR SED fitting poorly constrains the radial extent of the torus. For the Seyfert 2 galaxies, we find that edge-on geometries are more probable than face-on views, with a number of clouds along equatorial rays of N{sub 0} = 5-15. The 10 {mu}m silicate feature is generally modeled in shallow absorption. For the intermediate-type Seyferts, N{sub 0} and the inclination angle of the torus are lower than those of the Seyfert 2 nuclei, with the silicate feature appearing in weak emission or absent. The columns of material responsible for the X-ray absorption are larger than those inferred from the model fits for most of the galaxies, which is consistent with X-ray absorbing gas being located within the dust sublimation radius, whereas the mid-IR flux arises from an area farther from the accretion disk. The fits yield both the bolometric luminosity of the intrinsic AGN and the torus-integrated luminosity, from which we derive the reprocessing efficiency of the torus. In the models, the outer radial extent of the torus scales with the AGN luminosity, and we find the tori to be confined to scales less than 5 pc.

79 ASTRONOMY AND ASTROPHYSICS↗

Visualizing the Nanoscale Oxygen and Cation Transport Mechanisms during the Early Stages of Oxidation of Fe–Cr–Ni Alloy Using In Situ Atom Probe Tomography

Abstract Understanding the early stages of interactions between oxygen and material surfaces—especially at very high spatial resolutions—is highly beneficial for fields ranging from materials degradation, corrosion, geological sciences, forensics, and catalysis. The ability of in situ atom probe tomography (APT) is demonstrated to track the diffusion of oxygen and metal ions at nanoscale spatial resolution during the early stages of oxidation of a model Fe–Cr–Ni alloy. Using 18 O isotope tracers in these in situ APT experiments and complementary ex situ multimodal microscopy, spectroscopy, and computational simulations allows to precisely analyze the kinetics of oxidation and determine that outward cation diffusion to oxide/air interface is the primary mechanism for intragranular oxide growth in this alloy at 300 °C. This unique in situ isotopic tracer APT approach and the insights gained can be highly beneficial for studying early stages of gas–surface reactions in a broad array of materials.

36 MATERIALS SCIENCE↗

Theoretical investigation of the design and performance of a dual energy (kV and MV) radiotherapy imager

Purpose: In modern radiotherapy treatment rooms, megavoltage (MV) portal imaging and kilovoltage (kV) cone-beam CT (CBCT) imaging are performed using various active matrix flat-panel imager (AMFPI) designs. To expand the clinical utility of MV and kV imaging, MV AMFPIs incorporating thick, segmented scintillators and, separately, kV imaging using a beam’s eye view geometry have been investigated by a number of groups. Motivated by these previous studies, it is of interest to explore to what extent it is possible to preserve the benefits of kV and MV imaging using a single AMFPI design, given the considerably different x ray energy spectra used for kV and MV imaging. In this paper, considerations for the design of such a dual energy imager are explored through examination of the performance of a variety of hypothetical AMFPIs based on x ray converters employing segmented scintillators. Methods: Contrast, noise, and contrast-to-noise ratio performances were characterized through simulation modeling of CBCT imaging, while modulation transfer function, Swank factor, and signal performance were characterized through simulation modeling of planar imaging. The simulations were based on a previously reported hybrid modeling technique (accounting for both radiation and optical effects), augmented through modeling of electronic additive noise. All designs employed BGO scintillator material with thicknesses ranging from 0.25 to 4 cm and element-to-element pitches ranging from 0.508 to 1.016 mm. A series of studies were performed under both kV and MV imaging conditions to determine the most advantageous imager configuration (involving front or rear x ray illumination and use of a mirror or black reflector), converter design (pitch and thickness), and operating mode (pitch-binning combination). Results: Under the assumptions of the present study, the most advantageous imager design was found to employ rear illumination of the converter in combination with a black reflector, incorporate a BGO converter with a 0.508 mm pitch and a 2 cm thickness, and operate at full resolution for kV imaging and 2 × 2 binning mode for MV imaging. Such a dual energy imager design should provide soft tissue visualization at low, clinically practical doses under MV conditions, while helping to preserve the high spatial resolution and high contrast offered by kV imaging. Conclusions: The authors’ theoretical investigation suggests that a dual energy imager capable of largely preserving the desirable characteristics of both kV and MV imaging is feasible. Such an imager, when coupled to a dual energy radiation source, could facilitate simplification of current treatment room imaging systems (as well as their associated quality assurance), and facilitate more precise integration of kV and MV imaging information by virtue of reduced geometric uncertainties.

07 ISOTOPE AND RADIATION SOURCES↗