Search NASA⌕ Search

SEARCH · Search NASA

Results for “higher heating value”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Evaluation of advanced combustion concepts for dry NO sub x suppression with coal-derived, gaseous fuels

The emissions performance of a rich lean combustor (developed for liquid fuels) was determined for combustion of simulated coal gases ranging in heating value from 167 to 244 Btu/scf (7.0 to 10.3 MJ/NCM). The 244 Btu/scf gas is typical of the product gas from an oxygen blown gasifier, while the 167 Btu/scf gas is similar to that from an air blown gasifier. NOx performance of the rich lean combustor did not meet program goals with the 244 Btu/scf gas because of high thermal NOx, similar to levels expected from conventional lean burning combustors. The NOx emissions are attributed to inadequate fuel air mixing in the rich stage resulting from the design of the large central fuel nozzle delivering 71% of the total gas flow. NOx yield from ammonia injected into the fuel gas decreased rapidly with increasing ammonia level, and is projected to be less than 10% at NH3 levels of 0.5% or higher. NOx generation from NH3 is significant at ammonia concentrations significantly less than 0.5%. These levels may occur depending on fuel gas cleanup system design. CO emissions, combustion efficiency, smoke and other operational performance parameters were satisfactory. A test was completed with a catalytic combustor concept with petroleum distillate fuel. Reactor stage NOx emissions were low (1.4g NOx/kg fuel). CO emissions and combustion efficiency were satisfactory. Airflow split instabilities occurred which eventually led to test termination.

Beebe, K. W.↗

Solar cycle variations of electron density and temperature in the Venusian nightside ionosphere

The return of periapsis to low altitudes during the Summer and Fall of 1992 provided a unique opportunity for the Pioneer Venus Orbiter (PVO) to make in situ measurements in the Venusian ionosphere at much lower levels of solar activity (F10.7 approx. equals 120) than existed when periapsis was at low altitudes in 1979 and 1980 (F10.7 approx. equals 220). We present the observations of electron density (N(sub e)) and temperature (T(sub e)) made by the Orbiter Electron Temperature Probe (OETP) during the Entry Period. Empirical models of the N(sub e) and T(sub e) height variations are presented and compared with similar models based on OETP measurements made at solar maximum. The median N(sub e) at the ionospheric peak (approx. 140 km) was essentially unchanged from its solar maximum value, but the ionosphere was increasingly depleted at higher altitudes, reaching a factor of 7 lower densities at 200 km. T(sub e) was lower by almost a factor of 2 at 140 km but was rather significantly enhanced at higher altitudes; exceeding its solar maximum values by a factor of 1.3 at 200 km and a factor of 2 at 500 km. In general these results support the earlier conclusions that the nightside upper ionosphere is depleted at lower levels of solar activity by a reduction of the nightward ion flow. The lack of N(sub e) variation near the peak (between solar maximum and entry) suggests that nightward ion transport does not play as large a role in the peak formation as does local ion production by energetic particles. The decrease does local ion production by energetic particles. The decrease in T(sub e) at low altitudes suggests that the low densities of the upper ionosphere at the time of PVO entry could no longer support the conduction of heat from the dayside ionosphere, thus allowing the lower nightside ionosphere to cool by collisions with ions and neutrals, and by heat conduction to the cooler regions below.

Theis, Robert F.↗

Status of Analysis and Manufacturability of Superconducting Wires with Low AC Losses

Superconductors can carry an order-of-magnitude higher current than room temperature copper wires and can do so with two orders-of-magnitude lower alternating current (AC) electrical losses. These advantages underlie our estimates that turboelectric propulsion of large aircraft can be enabled by superconducting machines. However, even the much smaller losses of superconductors pose thermal management issues at the low temperatures required for superconductivity, and predicting those losses and validating the predictions has been a developing process at NASA Glenn Research Center over the last decade. Since Glenn’s earliest assessments of the feasibility of fully superconducting machines for turboelectric propulsion, the available models of AC losses in superconductors have changed significantly, as well as the state of development of superconducting wire for the coils of electric machines. While the models available to us have improved significantly, the value of the AC losses predicted by these models have only increased as more fidelity was developed. The fabrication of medium temperature superconducting wires (Tc near 40 K) has advanced, and wires can be produced with finer filaments and tighter twisting than a decade ago. However, the ideal wire configurations, developed decades ago for low temperature superconductors (Tc < 25 K), still elude manufacturers of medium and high temperature (Tc > 77 K) superconductors. This report discusses the developments, the current limitations, and the expectations that future configurations of superconducting wire can yet be produced that will provide suitably low AC losses for the aircraft propulsion application. The report presents a basic discussion of the types of AC losses in superconductors, followed by a discussion of the evolution of our understanding of the practical consequences of those AC losses. Next, there is a discussion of the superconducting wire configurations that have been developed, which were partially guided by that understanding. A brief discussion of the modes of removing the heat produced by the losses is presented. Lastly, a comparison is presented between losses in currently available MgB2 wire and other important cases, including copper at room temperature, copper at liquid hydrogen temperature, and expected future MgB2 wire. Room temperature copper has 100 times the loss of today’s MgB2 and 300 times the expected loss of future MgB2. That implies we can expect much higher efficiency from fully superconducting machines than from machines with copper stators, and high efficiency targets remain the driver behind investment in MgB2 development and medium temperature superconductor research.

superconducting motors↗

A future, intense source of negative hydrogen ions

By directly heating lithium hydride in a vacuum, up to 18 micro-A/sq cm of negative hydrogen has been obtained from the crystal lattice. The amount of ion current extracted and analyzed is closely related to the temperature of the sample and to the rate at which the temperature is changed. The ion current appears to be emission limited and saturates with extraction voltage. For a fixed extraction voltage, the ion current could be maximized by placing a grid between the sample surface and the extraction electrode. Electrons accompanying the negative ions were removed by a magnetic trap. A Wein velocity filter was designed and built to provide definitive mass analysis of the extracted ion species. This technique when applied to other alkali hydrides may produce even higher intensity beams possessing low values of emittance.

Siefken, Hugh↗

Using Thermal Desktop to Determine Equivalent Solar Hours on Spacecraft Surfaces

Equivalent solar hours (ESH) are the duration of exposure of a surface to solar radiation, particularly ultraviolet (UV) radiation. Since UV light causes degradation to optical properties of thermal control surfaces, the determination of ESH is important to calculate end of life (EOL) optical properties for spacecraft external surfaces. A higher ESH value generally correlates to greater UV degradation experienced by the surface, resulting in an increase in solar absorptivity. This paper details a novel approach for calculating ESH using Thermal Desktop. Since the ESH value is useful for thermal analysts, this technique is beneficial to quickly perform the analysis internally with tools readily available without relying on external support and funding. The example presented in this paper shows how this method was developed and used for NASA's lunar Gateway spacecraft. This method of analysis is used to calculate ESH for the transit, assembly in orbit, and operational phases for Gateway, utilizing each of the program’s planned configurations throughout its 15-year lifetime. ESH values were calculated using the Monte-Carlo ray tracing capability of Thermal Desktop using both direct solar heating and indirect solar heating due to reflections from other surfaces. The output of this analysis includes an ESH gradient map across the spacecraft. Post-processing of these results enabled identification of the average and maximum ESH on critical surfaces such as radiators. The final ESH values for each surface are then used for determination of EOL optical properties.

Thermal Control↗

Apparatus for Measuring Total Emissivity of Small, Low-Emissivity Samples

An apparatus was developed for measuring total emissivity of small, lightweight, low-emissivity samples at low temperatures. The entire apparatus fits inside a small laboratory cryostat. Sample installation and removal are relatively quick, allowing for faster testing. The small chamber surrounding the sample is lined with black-painted aluminum honeycomb, which simplifies data analysis. This results in the sample viewing a very high-emissivity surface on all sides, an effect which would normally require a much larger chamber volume. The sample and chamber temperatures are individually controlled using off-the-shelf PID (proportional integral derivative) controllers, allowing flexibility in the test conditions. The chamber can be controlled at a higher temperature than the sample, allowing a direct absorptivity measurement. The lightweight sample is suspended by its heater and thermometer leads from an isothermal bar external to the chamber. The wires run out of the chamber through small holes in its corners, and the wires do not contact the chamber itself. During a steady-state measurement, the thermometer and bar are individually controlled at the same temperature, so there is zero heat flow through the wires. Thus, all of sample-temperature-control heater power is radiated to the chamber. Double-aluminized Kapton (DAK) emissivity was studied down to 10 K, which was about 25 K colder than any previously reported measurements. This verified a minimum in the emissivity at about 35 K and a rise as the temperature dropped to lower values.

Tuttle, James↗

Upflowing ionospheric ions in the auroral region

Observations of upflowing ionospheric ions are obtained nearly simultaneously by DE 1 and DE 2 over the nightside auroral regions. At low altitudes, the mean value of the net upward ion number flux is of the order of 10 exp 9/sq cm per sec. The ionosphere is predominantly O(+), and the flux of ions with energy greater than 5 eV is a very small fraction (less than 1 percent) of the total ion flux. At high altitudes, the upflowing ions are accelerated by a parallel electric field and heated (with characteristic energies of hundreds of electron volts). Comparing upflowing fluxes at high and low altitudes yields an estimated height of the bottom of the auroral acceleration region of 1400-1700 km for the region of peak potential drop. This low-altitude acceleration could either be from a parallel electric field or from perpendicular acceleration. The fluxes at the edges of the arc are mostly H(+) thus implying a higher-altitude base of the acceleration region at the edges where the potential drop is lower.

Lu, G.↗

Heat and Momentum Transfer Studies in High Reynolds Number Wavy Films at Normal and Reduced Gravity Conditions

We examined the effect of the gas flow on the liquid film when the gas flows in the countercurrent direction in a vertical pipe at normal gravity conditions. The most dramatic effect of the simultaneous flow of gas and liquid in pipes is the greatly increased transport rates of heat, mass, and momentum. In practical situations this enhancement can be a benefit or it can result in serious operational problems. For example, gas-liquid flow always results in substantially higher pressure drop and this is usually undesirable. However, much higher heat transfer coefficients can be expected and this can obviously be of benefit for purposes of design. Unfortunately, designers know so little of the behavior of such two phase systems and as a result these advantages are not utilized. Due to the complexity of the second order boundary model as well as the fact that the pressure variation across the film is small compared to the imposed gas phase pressure, the countercurrent gas flow affect was studied for the standard boundary layer model. A different stream function that can compensate the shear stress affect was developed and this stream function also can predict periodic solutions. The discretized model equations were transformed to a traveling wave coordinate system. A stability analysis of these sets of equations showed the presence of a Hopf bifurcation for certain values of the traveling wave velocity and the shear stress. The Hopf celerity was increased due to the countercurrent shear. For low flow rate the increases of celerity are more than for the high flow rate, which was also observed in experiments. Numerical integration of a traveling wave simplification of the model also predicts the existence of chaotic large amplitude, nonperiodic waves as observed in the experiments. The film thickness was increased by the shear.

Balakotaiah, V.↗

Thermocapillary Flow and Aggregation of Bubbles on a Solid Wall

During the electrolytic evolution of oxygen bubbles forming on a vertically oriented transparent tin oxide electrode, bubbles were found to be mutually attractive. The mechanism of the aggregation had never been explained satisfactorily until Guelcher et al. attributed it to thermocapillary flow. The gradient of surface tension of the liquid at the bubble's surface, which was established because of reaction heat and ohmic heat loss at the electrode wall, drives flow of the liquid adjacent to each bubble; the bubble "pumps" fluid along its surface away from the wall. Fluid flows toward the bubble to conserve mass and entrains nearby bubbles in the flow pattern. The same logic would apply when two bubbles of equal size are adjacent to each other on a warm wall. Each bubble drives thermocapillary flow and hence entrains the other in its flow pattern, which drives the aggregation. Our objective here is to perform experiments where the temperature gradient at the wall is well known and controlled. The theory can be quantitatively tested by studying aggregation of bubble pairs of equal size, and by varying system parameters such as temperature gradient, bubble size and fluid viscosity. The results are then compared with the theory in a quantitatively rigorous manner. We demonstrate that the theory without adjustable parameters is capable of quantitatively modeling the rate of aggregation of two bubbles. The equations governing the thermocapillary flow around a single stationary bubble on a heated or cooled wall in a semi-infinite domain were solved. Both Reynolds number and Marangoni number were much less than unity. The critical result is that liquid in the vicinity of a warm wall flows toward a stationary collector bubble. Consequently the thermocapillary flow around the stationary bubble entrains another bubble toward itself. The bubbles undergo hindered translation parallel to the wall with velocity U while the fluid flow field is described with u. Two velocities were equated by using a wall hindrance parameter q: U = qu [1] which shows the velocity of bubble is proportional to the entraining velocity. The hindrance parameter q can experimentally be measured independently. q can also be calculated by solving the equations of motion for a bubble translating parallel to a solid wall. The experimental cell is cylindrical with an ID of 10 cm and consists of a 1 cm deep main cell filled with silicone oil and flanked by two thermal reservoirs. The upper thermal reservoir was heated and the lower thermal reservoir was cooled so that the bubbles aggregate. Two types of silicone oil (eta = 0.02 and 0.50 Pa s) were used. Two equal sized air bubbles were injected into the cell with a syringe. The center-to-center distance of bubbles was observed through a microscope. Bubble radius ranged from 0.40 mm to 0.65 mm and the temperature gradients along with the cell ranged from 1400 to 5000 K/m. The bubbles aggregated when heat flows from the wall to the fluid. The velocities of bubbles were in the range of 1 - 10 microns/s. The separation r decreased more quickly when the temperature gradient was higher, bubble size was larger, and the oil viscosity was lower. r decreased more rapidly as the bubbles approached each other. Dimensionless time was arbitrarily set to be zero when the dimensionless center-to-center distance between the bubbles was 4. All the bubble trajectories fall onto one line, especially in the range of dimensionless distance from 4 to 3. This means the relative movement of the bubble pair is proportional to the temperature gradient and bubble size and it is inversely proportional to the viscosity of the oil. This result strongly suggests that the thermocapillary flow-based aggregation mechanism is correct. A value of q can be estimated by fitting the scaled data to Eq. [1]. A best fit value of q was obtained as q = 0.26 with a standard deviation of 0.03. Independent experimental results for q for a 0.5 mm radius bubble, give values of q in the range 0.11 to 0.23. The value of q obtained from solving the equations of motion reveals q has values in the range 0.23 - 0.30. Since the full scale of possible values of q is zero to one, the maximum deviation of independently determined values of q from the best fit value was 15% of this full scale. Thus reasonable quantitative agreement between theory and experiment has been obtained.

Kasumi, Hiroki↗

Development of Ceramic Fibers for Reinforcement in Composite Materials

Refinements of the vertical arc fiberizing apparatus resulted in its ability to fiberize very different refractory glasses having wide ranges of properties. Although the apparatus, was originally designed as a laboratory research tool for the evaluation of many compositions daily, up to one quarter pound of fibers of a single composition could be produced in an 8-hour day. Fibers up to six and a half feet long were produced with the apparatus. Studies were conducted of two methods of fiberizing refractory glasses requiring rapid freezing from the melt. The first method consisted of fiberizing droplets of molten glass passing through an annular nozzle. The second method consisted of reconstructing the annular nozzle in. the shape of a horseshoe to achieve a shorter delay in blasting a molten droplet from the tip of a rod. Both methods were judged feasible for producing fibers of glasses requiring rapid freezing. The first method would be more amenable to volume fiber production. Studies of induction heating for fiber formation did not lead to its designation as a very efficient heating method. Problems. remain to be solved, in the design of a suitable susceptor for a higher heating rate, in protecting the susceptor from oxidation with an inert gas, in contamination of the melt from a refractory crucible, and in the protective radiation shielding of the induction concentrator coil. It is not considered practical to continue studies of this heating method. In the course of this program 151 refractory glass compositions were evaluated for fiber, forming characteristics. Of the various types of materials studied, the following showed promise in producing acceptable refractory fibers: sIlica- spinel (magnesium aluminate), silica- spinel-zirconia, silica-zirconia, silica-zinc spinel, aluminum phosphate glasses, and fluoride glasses. Compositions which did not produce acceptable fibers were high zirconia materials, barium spinels, and calcium aluminates. Improvements in the. testing apparatus for single fiber tensile strength increased the precision. of tests conducted on nine fibers. The highest mean tensile strength, a value of 295,000 pounds per square inch, was obtained with R-141 fibers. Treatment of R-74 fibers with anhydrous Linde A-1100 silane finish improved its mean fiber tensile strength by 25 percent. The lapse of time after fiber formation had no measurable effect on tensile strength. A static heating test conducted with various high melting fibers indicated that Fiberfrax and R-108 underwent no significant changes in bulk volume or resiliency on exposure to 2750 degrees Fahrenheit (1510 degrees Centigrade) in an oxidizing atmosphere. For fiber-resin composition fabrication, ten fiber materials were selected on the bases of high fiber yield, fusion temperature, and type of composition. Fiberfrax, a commercial ceramic fiber, was included for comparison. A new, more effective method of removing pellets from blown fibers was developed. The de-pelletized fibers were treated with a silane finish and felted into ten-inch diameter felts prior to resin impregnation. Composites containing 30 percent by weight of CTL 91-LD phenolic resin were molded under high pressure from the impregnated felts and post-cured to achieve optimum properties. Flexural strength, flexural modules of elasticity, and punch shear strength tests were conducted on the composite specimens. The highest average flexural strength obtained was 19,958 pounds per square inch with the R-74-fiber-resin composite. This compares very favorably with the military specification of 13,000 pounds per square inch flexural strength for randomly oriented fiber reinforced composites. The highest punch shear strength (11,509 pounds per square inch) was obtained with the R-89 fiber-resin composite. The effects of anhydrous fiber finishes on composite strength were not clearly indicated. Plasma arc tests at a heat flux of 550 British Thermal Units per square foot per second on eight composite materials indicated ablation rates generally equivalent to Fiberglas-Micarta No. 259-2. The composite reinforced with R-99 fibers had an average ablation rate of 0.008 inch per second and appears quite promising on the basis of these tests. Preliminary studies for processing fibers into yarn and fabric were conducted with R-99 fibers. The use of certain organic gums aided in 2 fabricating by hand several relatively strong yarns and a crude fabric swatch. This indicated the practicality of developing techniques for processing these fibers into yarn and fabric without significant damage to the fibers.

Gates, L. E.↗

Phase transformations in SrAl2Si2O8 glass

Bulk glass of SrAl2Si2O8 composition crystallized at temperatures below 1000 C into hexacelsian, a hexagonal phase which undergoes a reversible, rapid transformation to an orthorhombic phase at 758 C, and at higher temperatures crystallized as celsian, a monoclinic phase. The glass transition temperature and crystallization onset temperature were determined to be 883 C and 1086 C, respectively, from DSC at a heating rate of 20 C/min. Thermal expansion of the various phases and density and bend strengths of cold isostatically pressed glass powder bars, sintered at various temperatures, were measured. The kinetics of the hexacelsian-to-celsian transformation for SrAl2Si2O8 were studied. Hexacelsian flakes were isothermally heat treated at temperatures from 1025-1200 C for various times. Avrami plots were determined by quantitatively measuring the amount of monoclinic celsian formed at various times using x ray diffraction. The Avrami constant was determined to be 1.1, suggesting a diffusionless, one dimensional transformation mechanism. The activation energy was determined from an Arrhenius plot of 1n k vs. 1/T to be 125 kilocal/mole. This value is consistent with a mechanism which transforms the layered hexacelsian structure to a three dimensional framework celsian structure and involves the breaking of Si-O bonds.

Drummond, Charles H., III↗

Petrologic model of the northern Mississippi Embayment based on satellite magnetic and ground-based geophysical data

A petrologic model of the northern Mississippi Embayment, derived from gravity, seismic and rift data, is evaluated by converting the model to a magnetization model which is compared with satellite magnetic anomaly models. A magnetization contrast of approximately -0.54 A/m, determined from the petrologic model of the embayment compares favorably to values of -0.62 A/m and -0.45 A/m from a Magsat United States Apparent Magnetization Contrast Map and a published POGO magnetization contrast model, respectively. The petrologic model suggests that the magnetic anomaly low associated with the Mississippi Embayment may be largely due to the intrusion under non-oxidizing conditions of low Curie temperature gabbroic material at the base of the crust of the embayment. Near-surface mafic plutons, bordering the Mississippi Valley Graben, appear from aeromagnetic data to have higher magnetizations than the deeper gabbroic material; however, it is impossible to ascertain if this is due to compositional differences or similar material at shallower (lower temperature) depths. These results indicate that variations in the Curie temperatures of intrusions accompanying rifting may account for a large part of the wide range of magnetic anomalies associated with presently inactive rifts with normal heat flow.

Thomas, H. H.↗

Properties of Graphite Fiber Reinforced Copper Matrix Composites for Space Power Applications

The thermal and mechanical properties of pitch-based graphite fiber reinforced copper matrix (Gr/Cu) composites usable for space applications such as radiator fins were investigated. Thermal conductivity was measured as a function of fiber volume fraction and architecture. Results showed for unidirectional P-100 Gr/Cu composites, the longitudinal thermal conductivity was nearly independent of fiber volume fraction. Transverse thermal conductivities (perpendicular to the fibers) were strongly affected by the fiber volume fraction with higher volume fractions resulting in lower thermal conductivities. The effect of architecture on thermal conductivity followed the cosine squared law for simple architectures. Insufficient data are available currently to model more complex architectures, but adding fibers in the direction of the heat flow increases the thermal conductivity as low conductivity plies are supplemented by high conductivity plies. Thermal expansion tests were conducted on the Gr fibers and Gr/Cu composites. The results show a considerable thermal expansion mismatch between the fibers and the Cu matrix. The longitudinal thermal expansion showed a strong dependence on the architecture of the Gr/Cu composites. The composites also show a thermal expansion hysteresis. The hysteresis was eliminated by an engineered interface. Mechanical testing concentrated on the dynamic modulus and strength of the composites. The dynamic modulus of the Gr/Cu composites was 305 GPa up to 400 C, a value equivalent to Be. The strengths of the composites were less than expected, but this is attributed to the poor bond across the interface between the Gr fibers and Cu matrix. Testing of composites with an engineered interface is expected to yield strengths nearer the values predicted by the rule of mixtures.

Ellis, David L.↗

Development of an Extreme High Temperature n-type Ohmic Contact to Silicon Carbide

We report on the initial demonstration of a tungsten-nickel (75:25 at. %) ohmic contact to silicon carbide (SiC) that performed for up to fifteen hours of heat treatment in argon at 1000 C. The transfer length method (TLM) test structure was used to evaluate the contacts. Samples showed consistent ohmic behavior with specific contact resistance values averaging 5 x 10-4 -cm2. The development of this contact metallization should allow silicon carbide devices to operate more reliably at the present maximum operating temperature of 600 C while potentially extending operations to 1000 C. Introduction Silicon Carbide (SiC) is widely recognized as one of the materials of choice for high temperature, harsh environment sensors and electronics due to its ability to survive and continue normal operation in such environments [1]. Sensors and electronics in SiC have been developed that are capable of operating at temperatures of 600 oC. However operating these devices at the upper reliability temperature threshold increases the potential for early degradation. Therefore, it is important to raise the reliability temperature ceiling higher, which would assure increased device reliability when operated at nominal temperature. There are also instances that require devices to operate and survive for prolonged periods of time above 600 oC [2, 3]. This is specifically needed in the area of hypersonic flight where robust sensors are needed to monitor vehicle performance at temperature greater than 1000 C, as well as for use in the thermomechanical characterization of high temperature materials (e.g. ceramic matrix composites). While SiC alone can withstand these temperatures, a major challenge is to develop reliable electrical contacts to the device itself in order to facilitate signal extraction

Evans, Laura J.↗

Transition and Turbulence Modeling for Blunt-Body Wake Flows

Aerobraking has been proposed as an efficient means of decelerating spacecraft for planetary missions. Most current aerobrake designs feature a blunt forebody shielding the payload from the intense heat generated during atmospheric entry. Although this forebody will absorb the largest portion of the heat pulse, accurate prediction of heating in the near wake is of great importance, since large local heating values can occur at points of shear-layer impingement. In order to address the various issues associated with these blunt-body wake flowfields, the Advisory Group for Aerospace Research and Development (AGARD) formed Working Group 18 in 1992. One of the objectives of this activity was to examine real-gas effects in high-speed flow fields around a 70 deg. blunted cone. To date, many researchers have conducted experiments using this geometry in various facilities, such as the Large Energy National Shock (LENS) tunnel at Cubric/Calspan and the HEG shock tunnel at DLR-Goettingen. Several computational studies have also been conducted in concert with these tests. Many of the experimental results have indicated the possible presence of a transitional shear layer through a large increase in heat transfer downstream of the reattachment point. The presence of transition could in fact lead to much higher peak heating than if the separated flow is entirely laminar or turbulent. In the shock-tunnel tests, however, it is difficult to separate such viscous-flow phenomena from real-gas effects. In order to help make this distinction, Horvath et al. recently conducted a set of experiments in the NASA Langley 20-Inch Mach 6 Tunnel, and compared the results to laminar Navier-Stokes calculations. They found heat-transfer distributions similar to those obtained in the high-enthalpy facilities, with the measured peak heating along the sting support markedly greater than that predicted by the laminar computations. These trends point to the need to find transitional and turbulent computational solutions for these flowfields.

Nance, Robert P.↗

The compositional structure and the effects of exothermicity in an unpremixed planar jet flame

Results are presented of direct numerical simulations (DNS) of a randomly perturbed compressible, spatially developing planar jet under the influence of a finite rate Arrhenius chemical reaction of the type F + O yields Product + Heat. The objectives of the simulations are to assess the compositional structure of the flame and to determine the influence of reaction exothermicity by means of statistical sampling of the data generated by DNS. It is shown that even with this idealized kinetics model, the simulated results exhibit features in accordance with experimental data. These results indicate that the Damkoehler number is an important parameter in determining the statistical composition of the reacting field, and that the results are insensitive to the mechanism by which this parameter is varied. It is demonstrated that as the intensity of mixing is increased and the effect of finite rate chemistry is more pronounced, the magnitudes of the ensemble mean and rms of the product mass fraction decrease, and those of the reactants mass fraction increase. Also, at higher mixing rates the joint probability density functions of the reactants' mass fractions shift towards higher values within the composition domain indicating a lower reactedness. These trends are consistent with those observed experimentally and are very useful in portraying the statistical structure of non-equilibrium diffusion flames. The DNS generated data are also utilized to examine the applicability of the 'laminar diffusion flamelet model' in predicting the rate of the reactant conversion with finite rate chemistry. This examination indicates that the bounds of the product formation scale reasonably well with those obtained by the flamelet model. However, in the range of the relatively low values of the Damkoehler numbers considered, the scatter of the results is substantially more than that to be completely determined by the closure.

Steinberger, C. J.↗

Erosion Data from the MISSE 8 Polymers Experiment After 2 Years of Space Exposure on the International Space Station

The Polymers Experiment was exposed to the low Earth orbit (LEO) space environment for 2.14 and 2.0 years as part of the Materials International Space Station Experiment 8 (MISSE 8) and the Optical Reflector Materials Experiment-III (ORMatE-III), respectively. The experiment contained 42 samples, which were flown in either ram, wake, or zenith orientations. The primary objective was to determine the effect of solar exposure on the atomic oxygen erosion yield (Ey) of fluoropolymers. This paper provides an overview of the experiment with details on the polymers flown, the characterization techniques used, the atomic oxygen fluence for each exposure orientation, and the LEO Ey results. The Ey values for the fluoropolymers range from 1.45 x 10(exp -25) cm(exp 3)/atom for white Tedlar Registered Trademark (polyvinyl fluoride with white titanium dioxide pigment) flown in the ram orientation to 6.32 x 10(exp -24) cm(exp 3)/atom for aluminized-Teflon Registered Trademark fluorinated ethylene propylene (Al-FEP) flown in the zenith orientation. Erosion yield data for FEP flown in ram, wake and zenith orientations are compared, and the Ey was found to be highly dependent on orientation, hence environmental exposure. Teflon FEP had an order of magnitude higher Ey when flown in the zenith direction (6.32 x10(exp -24) cm(exp3)/atom) as compared to the ram direction (2.37 x 10(exp -25) cm(exp 3)/atom). The Ey of FEP was found to increase with a direct correlation to the solar exposure/AO fluence ratio showing the effect of solar radiation and/or heating due to solar exposure on FEP erosion. In addition, back-surface carbon painted FEP (C-FEP) flown in the zenith orientation had a significantly higher Ey than clear FEP or Al-FEP further indicating that heating has a significant impact on the erosion of FEP, particularly in the zenith orientation.

Solar radiation↗

Demonstration of Oxygen and Carbon Monoxide Propellants for Mars Missions

Currently, proposed planetary exploration missions must be small, with low costs and a short development time. Relatively high-risk technologies are being accepted for such missions if they meet these guidelines. For a Mars sample-return mission, one of the higher risk technologies is the use of return propellants produced from indigenous materials such as the Martian atmosphere. This consists of 96 percent carbon dioxide, which can be processed into oxygen and carbon monoxide. This year, the NASA Lewis Research Center completed the experimental evaluation and subscale technology development of an oxygen/carbon monoxide propellant combination. Previous research included ignition characterization, combustion performance, and heat transfer characterization with gaseous propellants at room temperature. In this year s tests, we studied the ignition characteristics and combustion of oxygen and carbon monoxide at near liquid temperatures. The mixture ratio boundaries for oxygen and carbon monoxide were determined as a function of propellant temperature in a spark torch igniter. With both propellants at room temperature, the ignition range was between 0.50 and 1.44; and with both propellants chilled to near-liquid temperatures, it was between 2.4 and 3.1. Statistical analysis of the mean value of the ignition boundaries provided models that describe the combination of oxygen temperature, carbon monoxide temperature, and mixture ratio that resulted in ignition. This range is the larger boxed area shown in the figure. The smaller boxed area indicates the range at which there is a 90-percent confidence that ignition will occur. The relatively small range at only 90-percent confidence indicates that using the oxygen/carbon monoxide combination as its own ignition source may not be the best design for a remote engine operating on Mars. Tests also were performed in a simulated small rocket engine that used oxygen/hydrogen combustion gases as the ignition source for oxygen/carbon monoxide. In these experiments, the oxygen/carbon monoxide was successfully ignited in eight of eight tests at a mixture ratio of 0.52. In addition, the oxygen/carbon monoxide maintained steady combustion after the oxygen/hydrogen ignition source was removed, verifying that the oxygen/carbon monoxide rocket engine should continue to be included in mission plans as return propulsion from Mars.

Linne, Diane L.↗