Search NASA⌕ Search

SEARCH · Search NASA

Results for “image collection simulation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

HIGH-PRECISION ASTROMETRY WITH A DIFFRACTIVE PUPIL TELESCOPE

Astrometric detection and mass determination of Earth-mass exoplanets require sub-{mu}as accuracy, which is theoretically possible with an imaging space telescope using field stars as an astrometric reference. The measurement must, however, overcome astrometric distortions, which are much larger than the photon noise limit. To address this issue, we propose to generate faint stellar diffraction spikes using a two-dimensional grid of regularly spaced small dark spots added to the surface of the primary mirror (PM). Accurate astrometric motion of the host star is obtained by comparing the position of the spikes to the background field stars. The spikes do not contribute to scattered light in the central part of the field and therefore allow unperturbed coronagraphic observation of the star's immediate surroundings. Because the diffraction spikes are created on the PM and imaged on the same focal plane detector as the background stars, astrometric distortions affect equally the diffraction spikes and the background stars and are therefore calibrated. We describe the technique, detail how the data collected by the wide-field camera are used to derive astrometric motion, and identify the main sources of astrometric error using numerical simulations and analytical derivations. We find that the 1.4 m diameter telescope, 0.3 deg{sup 2} field we adopt as a baseline design achieves 0.2 {mu}as single measurement astrometric accuracy. The diffractive pupil concept thus enables sub-{mu}as astrometry without relying on the accurate pointing, external metrology, or high-stability hardware required with previously proposed high-precision astrometry concepts.

79 ASTRONOMY AND ASTROPHYSICS↗

National Security Science and Technology Initiative: Air Cargo Screening

The non-intrusive inspection (NII) of consolidated air cargo carried on commercial passenger aircraft continues to be a technically challenging, high-priority requirement of the Department of Homeland Security's Science and Technology Directorate (DHS S&T), the Transportation Security Agency and the Federal Aviation Administration. The goal of deploying a screening system that can reliably and cost-effectively detect explosive threats in consolidated cargo without adversely affecting the flow of commerce will require significant technical advances that will take years to develop. To address this critical National Security need, the Battelle Memorial Institute (Battelle), under a Cooperative Research and Development Agreement (CRADA) with four of its associated US Department of Energy (DOE) National Laboratories (Oak Ridge, Pacific Northwest, Idaho, and Brookhaven), conducted a research and development initiative focused on identifying, evaluating, and integrating technologies for screening consolidated air cargo for the presence of explosive threats. Battelle invested $8.5M of internal research and development funds during fiscal years 2007 through 2009. The primary results of this effort are described in this document and can be summarized as follows: (1) Completed a gap analysis that identified threat signatures and observables, candidate technologies for detection, their current state of development, and provided recommendations for improvements to meet air cargo screening requirements. (2) Defined a Commodity/Threat/Detection matrix that focuses modeling and experimental efforts, identifies technology gaps and game-changing opportunities, and provides a means of summarizing current and emerging capabilities. (3) Defined key properties (e.g., elemental composition, average density, effective atomic weight) for basic commodity and explosive benchmarks, developed virtual models of the physical distributions (pallets) of three commodity types and three explosive benchmarks combinations, and conducted modeling and simulation studies to begin populating the matrix of commodities, threats, and detection technologies. (4) Designed and fabricated basic (homogeneous) commodity test pallets and fabricated inert stimulants to support experiments and to validate modeling/simulation results. (5) Developed/expanded the team's capabilities to conduct full-scale imaging (neutron and x-ray) experiments of air cargo commodities and explosive benchmarks. (6) Conducted experiments to improve the collection of trace particles of explosives from a variety of surfaces representative of air cargo materials by means of mechanical (air/vibration/pressure), thermal, and electrostatic methods. Air cargo screening is a difficult challenge that will require significant investment in both research and development to find a suitable solution to ensure the safety of passengers without significantly hindering the flow of commodities. The initiative funded by Battelle has positioned this group to make major contributions in meeting the air cargo challenge by developing collaborations, developing laboratory test systems, improving knowledge of the challenges (both technical and business) for air cargo screening, and increasing the understanding of the capabilities for current inspection methods (x-ray radiography, x-ray backscatter, etc.) and potential future inspection methods (neutron radiography, fusion of detector modalities, advanced trace detection, etc.). Lastly, air cargo screening is still an issue that will benefit from collaboration between Department of Energy Laboratories and Battelle. On January 7, 2010, DHS Secretary Napolitano joined White House Press Secretary Robert Gibbs and Assistant to the President for Counterterrorism and Homeland Security John Brennan to announce several recommendations DHS has made to the President for improving the technology and procedures used to protect air travel from acts of terrorism. (This announcement followed the 25 Dec'09 Delta/Northwest Airlines Flight 253 terror attack.) Secretary Napolitano outlined five recommendations DHS will pursue to enhance the safety of the traveling public. One of the five recommendations, read as follows: 'Establish a partnership on aviation security between DHS and the Department of Energy and its National Laboratories in order to develop new and more effective technologies to deter and disrupt known threats and proactively anticipate and protect against new ways by which terrorists could seek to board an aircraft.' In conclusion, it appears very timely that Battelle and its DOE lab partners initiated a serious collaboration on the air cargo topic, and that we should continue to work toward future collaboration in response to the government's needs.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Oxide nucleation via threshold-driven volume instability in Ni oxidation

Oxide nucleation dictates the onset of metal oxidation, yet the atomistic pathways bridging initial oxygen adsorption to bulk phase transformation remain elusive. Here, we utilize in-situ atomic-resolution imaging to directly capture the nucleation of nickel oxide, revealing a threshold-driven, cooperative transformation of Ni into NiO. Our observations identify a distinct incubation period during which oxygen progressively accumulates in subsurface layers. Once a critical concentration and penetration depth are reached, a collective lattice reconfiguration is triggered, abruptly converting multiple Ni layers into NiO. Atomistic simulations corroborate this mechanism, identifying a cooperative lattice instability induced by subsurface oxygen saturation. These results establish subsurface oxygen incorporation as the missing mechanistic link between surface adsorption and three-dimensional oxide formation, providing an atomistic framework to understand and control reactive phase transformations in materials synthesis, catalysis, and degradation.

36 MATERIALS SCIENCE↗

Retrieving plasmonic near-field information: A quantum-mechanical model for streaking photoelectron spectroscopy of gold nanospheres

Streaked photoemission from nanostructures is characterized by size- and material-dependent nanometer-scale variations of the induced nanoplasmonic response to the electronic field of the streaking pulse and thus holds promise of allowing photoelectron imaging with both subfemtosecond temporal and nanometer spatial resolution. In order to scrutinize the driven collective electronic dynamics in 10–200-nm-diameter gold nanospheres, we calculated the plasmonic field induced by streaking pulses in the infrared and visible spectral range and developed a quantum-mechanical model for streaked photoemission by extreme ultraviolet pulses. Overall, our simulated photoelectron spectra reveal a significant amplitude enhancement and phase shift of the photoelectron streaking trace relative to calculations that exclude the induced plasmonic field. Both are most pronounced for streaking pulses tuned to the plasmon frequency and retrace the plasmonic electromagnetic field enhancement and phase shift near the nanosphere surface.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Effect of Satellite Formations and Imaging Modes on Global Albedo Estimation

We confirm the applicability of using small satellite formation flight for multi-angular earth observation to retrieve global, narrow band, narrow field-of-view albedo. The value of formation flight is assessed using a coupled systems engineering and science evaluation model, driven by Model Based Systems Engineering and Observing System Simulation Experiments. Albedo errors are calculated against bi-directional reflectance data obtained from NASA airborne campaigns made by the Cloud Absorption Radiometer for the seven major surface types, binned using MODIS' land cover map - water, forest, cropland, grassland, snow, desert and cities. A full tradespace of architectures with three to eight satellites, maintainable orbits and imaging modes (collective payload pointing strategies) are assessed. For an arbitrary 4-sat formation, changing the reference, nadir-pointing satellite dynamically reduces the average albedo error to 0.003, from 0.006 found in the static reference case. Tracking pre-selected waypoints with all the satellites reduces the average error further to 0.001, allows better polar imaging and continued operations even with a broken formation. An albedo error of 0.001 translates to 1.36 W/sq m or 0.4% in Earth's outgoing radiation error. Estimation errors are found to be independent of the satellites' altitude and inclination, if the nadir-looking is changed dynamically. The formation satellites are restricted to differ in only right ascension of planes and mean anomalies within slotted bounds. Three satellites in some specific formations show average albedo errors of less than 2% with respect to airborne, ground data and seven satellites in any slotted formation outperform the monolithic error of 3.6%. In fact, the maximum possible albedo error, purely based on angular sampling, of 12% for monoliths is outperformed by a five-satellite formation in any slotted arrangement and an eight satellite formation can bring that error down four fold to 3%. More than 70% ground spot overlap between the satellites is possible with 0.5deg of pointing accuracy, 2 Km of GPS accuracy and commands uplinked once a day. The formations can be maintained at less than 1 m/s of monthly (Delta)V per satellite.

BRDF↗

Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data

While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Toward Multi-scale Modeling and simulation of conduction in heterogeneous materials

This report summarizes a project in which the authors sought to develop and deploy: (i) experimental techniques to elucidate the complex, multiscale nature of thermal transport in particle-based materials; and (ii) modeling approaches to address current challenges in predicting performance variability of materials (e.g., identifying and characterizing physical- chemical processes and their couplings across multiple length and time scales, modeling information transfer between scales, and statically and dynamically resolving material structure and its evolution during manufacturing and device performance). Experimentally, several capabilities were successfully advanced. As discussed in Chapter 2 a flash diffusivity capability for measuring homogeneous thermal conductivity of pyrotechnic powders (and beyond) was advanced; leading to enhanced characterization of pyrotechnic materials and properties impacting component development. Chapter 4 describes success for the first time, although preliminary, in resolving thermal fields at speeds and spatial scales relevant to energetic components. Chapter 7 summarizes the first ever (as far as the authors know) application of TDTR to actual pyrotechnic materials. This is the first attempt to actually characterize these materials at the interfacial scale. On the modeling side, new capabilities in image processing of experimental microstructures and direct numerical simulation on complicated structures were advanced (see Chapters 3 and 5). In addition, modeling work described in Chapter 8 led to improved prediction of interface thermal conductance from first principles calculations. Toward the second point, for a model system of packed particles, significant headway was made in implementing numerical algorithms and collecting data to justify the approach in terms of highlighting the phenomena at play and pointing the way forward in developing and informing the kind of modeling approach originally envisioned (see Chapter 6). In both cases much more remains to be accomplished.

36 MATERIALS SCIENCE↗

The "Very Cool" James Webb Space Telescope!

For over twenty years, scientists, engineers, technicians, and other personnel have been working on the next generation space telescope. As a partnership between NASA (National Aeronautics and Space Administration), CSA (Canadian Space Agency), and ESA (European Space Angency), the James Webb Space Telescope will complement the previous research performed by the Hubble by utilizing a larger primary mirror, which will also be optimized for infrared wavelengths. This combination will allow JWST to collect data and take images of light having traveled over 13.7 billion light years. This presentation will focus on the mission, as well as the contamination control challenges during the integration and testing in the NASA Goddard Spacecraft Systems Development and Integration Facility (SSDIF), one of the largest cleanrooms in the world. Additional information will be presented regarding space simulation testing down to a cool 20 degrees Kelvin [-424 degrees Fahrenheit] that will occur at Johnson Space Center in Houston, TX, and more testing and integration to happen at Northrop Grumman Corp., in Redondo Beach, CA. Launch of the JWST is currently scheduled for the spring of 2019 at Ariane Spaceport in French Guiana, South America.

space sciences↗

Snapshot multifocal light field microscopy

Light field microscopy (LFM) is an emerging technology for high-speed wide-field 3D imaging by capturing 4D light field of 3D volumes. However, its 3D imaging capability comes at a cost of lateral resolution. In addition, the lateral resolution is not uniform across depth in the light field dconvolution reconstructions. To address these problems, here, we propose a snapshot multifocal light field microscopy (MFLFM) imaging method. The underlying concept of the MFLFM is to collect multiple focal shifted light fields simultaneously. We show that by focal stacking those focal shifted light fields, the depth-of-field (DOF) of the LFM can be further improved but without sacrificing the lateral resolution. Also, if all differently focused light fields are utilized together in the deconvolution, the MFLFM could achieve a high and uniform lateral resolution within a larger DOF. We present a house-built MFLFM system by placing a diffractive optical element at the Fourier plane of a conventional LFM. The optical performance of the MFLFM are analyzed and given. Both simulations and proof-of-principle experimental results are provided to demonstrate the effectiveness and benefits of the MFLFM. We believe that the proposed snapshot MFLFM has potential to enable high-speed and high resolution 3D imaging applications.

He, Kuan↗

Low-dose x-ray tomography through a deep convolutional neural network

Synchrotron-based X-ray tomography offers the potential of rapid large-scale reconstructions of the interiors of materials and biological tissue at fine resolution. However, for radiation sensitive samples, there remain fundamental trade-offs between damaging samples during longer acquisition times and reducing signals with shorter acquisition times. We present a deep convolutional neural network (CNN) method that increases the acquired X-ray tomographic signal by at least a factor of 10 during low-dose fast acquisition by improving the quality of recorded projections. Short exposure time projections enhanced with CNN show similar signal to noise ratios as compared with long exposure time projections and much lower noise and more structural information than low-dose fats acquisition without CNN. We optimized this approach using simulated samples and further validated on experimental nano-computed tomography data of radiation sensitive mouse brains acquired with a transmission X-ray microscopy. We demonstrate that automated algorithms can reliably trace brain structures in datasets collected with low dose-CNN. As a result, this method can be applied to other tomographic or scanning based X-ray imaging techniques and has great potential for studying faster dynamics in specimens.

60 APPLIED LIFE SCIENCES↗

Experimental study of the atmospheric neutrino backgrounds for p{yields}e{sup +}{pi}{sup 0} searches in water Cherenkov detectors

The atmospheric neutrino background for proton decay via p{yields}e{sup +}{pi}{sup 0} in ring imaging water Cherenkov detectors is studied with an artificial accelerator neutrino beam for the first time. In total, 3.14x10{sup 5} neutrino events corresponding to about 10 megaton-years of atmospheric neutrino interactions were collected by a 1000 ton water Cherenkov detector (KT). The KT charged-current single {pi}{sup 0} production data are well reproduced by simulation programs of neutrino and secondary hadronic interactions used in the Super-Kamiokande (SK) proton decay search. The obtained p{yields}e{sup +}{pi}{sup 0} background rate by the KT data for SK from the atmospheric neutrinos whose energies are below 3 GeV is 1.63{sub -0.33}{sup +0.42}(stat){sub -0.51}{sup +0.45}(syst)(megaton-year){sup -1}. This result is also relevant to possible future, megaton-scale water Cherenkov detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic retrieval of cloud liquid water fields from a single scanning microwave radiometer aboard a moving platform – Part 1: Field trial results from the Wakasa Bay experiment

Tomographic methods offer great potential for retrieving three-dimensional spatial distributions of cloud liquid water from radiometric observations by passive microwave sensors. Fixed tomographic systems require multiple radiometers, while mobile systems can use just a single radiometer. Part 1 (this paper) examines the results from a limited cloud tomography trial with a single-radiometer airborne system carried out as part of the 2003 AMSR-E validation campaign over Wakasa Bay of the Sea of Japan. During this trial, the Polarimetric Scanning Radiometer (PSR) and Microwave Imaging Radiometer (MIR) aboard the NASA P-3 research aircraft provided a useful dataset for testing the cloud tomography method over a system of low-level clouds. We do tomographic retrievals with a constrained inversion algorithm using three configurations: PSR, MIR, and combined PSR and MIR data. The liquid water paths from the PSR retrieval are consistent with those from the MIR retrieval. The retrieved cloud field based on the combined data appears to be physically plausible and consistent with the cloud image obtained by a cloud radar. We find that some vertically-uniform clouds appear at high altitudes in the retrieved field where the radar shows clear sky. This is likely due to the sub-optimal data collection strategy. This sets the stage for Part 2 of this study that aims to define optimal data collection strategies using observation system simulation experiments.

54 ENVIRONMENTAL SCIENCES↗

Overview of the MISSE-16 Mission and Preliminary Characterization of Novel Space Weathered Materials

The Materials International Space Station Experiment (MISSE) project is a series of experiments that began in 2001, involving the deployment of external experiment platforms on the International Space Station (ISS). Since then, more than 4,000 materials were tested yielding valuable data and insights into the performance of materials and coatings in the harsh space environment, as well as providing a platform for testing and validating new materials and technologies. The results of the MISSE experiments have contributed to the development of more durable and reliable spacecraft and equipment, as well as improving our understanding of the space environment and its effects on human space exploration. To gain deeper insights into the changes in material properties of both novel and heritage spacecraft materials over the course of a mission, we proposed to enhance the MISSE hardware. This was achieved by integrating a high-resolution camera that can capture both RGB and IR color data, along with an updated illumination scheme. The identical sets of selected materials were mounted on the Zenith, Ram, and Wake faces of the ISS to expose them to predominant vacuum ultraviolet (VUV), atomic oxygen, and high-energy electron conditions. In addition, we exposed flight duplicates of these materials to a simulated space environment, which included sequential exposure to the same irradiation species on the ground. This allowed us to study the effects of space exposure on the materials in a controlled manner and to compare their behavior in both real and simulated space environments. The MISSE-FF flight sample collection comprised different classes of polymers, including polyimides from the Kapton family, manufactured by E.I du Pont de Nemours and Co., Polyethylene terephthalate (PET) materials, liquid crystal polymers, PI/Polyhedral Oligomeric Silsesquioxanes (POSS), and carbon and glass fiber reinforced polymers. The experimental cadence during the MISSE-16 mission (~6 months) included daily images of each sample for the first week, weekly for the next 2 months, and monthly the remaining duration of the mission. This paper will focus on the flight duplicate as well as the postflight optical characterization of novel and heritage materials currently under observation on the MISSE-FF.

Jainisha R Shah↗

Demonstration of Broadband Contrast at 1.2 Lambda/D for the EXCEDE Phase-Induced Amplitude Apodization Coronagraph

The proposed coronagraph instrument on the EXCEDE (EXoplanetary Circumstellar Environments and Disk Explorer) mission study uses a Phase-Induced Amplitude Apodization (PIAA) coronagraph architecture to enable high-contrast imaging of circumstellar debris disks and giant planets at angular separations as close in as the habitable zone of nearby host stars. We report on the experimental results obtained in the vacuum chamber at the Lockheed Martin Advanced Technology Center in 10 percent broadband light centered about 650 nanometers, with a median contrast of 1 x 10 (sup -5) between 1.2 and 2.0 lambda /D simultaneously with 3 x 10 (sup -7) contrast between 2 and 11 =D between 2 and 11 lambda/D for a single-sided dark hole using a deformable mirror (DM) upstream of the PIAA coronagraph. The results are stable and repeatable as demonstrated by three measurements runs with DM settings set from scratch and maintained on the best 90 percent out of the 1000 collected frames. We compare the reduced experimental data with simulation results from modeling observed experimental limits; performance is consistent with uncorrected low-order modes not estimated by the Low Order Wavefront Sensor (LOWFS). Modeled sensitivity to bandwidth and residual tip/tilt modes is well-matched to the experiment.

Wavefront control↗

Heterodyne frequency-domain multispectral diffuse optical tomography of breast cancer in the parallel-plane transmission geometry

Purpose: The authors introduce a state-of-the-art all-optical clinical diffuse optical tomography (DOT) imaging instrument which collects spatially dense, multispectral, frequency-domain breast data in the parallel-plate geometry. Methods: The instrument utilizes a CCD-based heterodyne detection scheme that permits massively parallel detection of diffuse photon density wave amplitude and phase for a large number of source–detector pairs (10{sup 6}). The stand-alone clinical DOT instrument thus offers high spatial resolution with reduced crosstalk between absorption and scattering. Other novel features include a fringe profilometry system for breast boundary segmentation, real-time data normalization, and a patient bed design which permits both axial and sagittal breast measurements. Results: The authors validated the instrument using tissue simulating phantoms with two different chromophore-containing targets and one scattering target. The authors also demonstrated the instrument in a case study breast cancer patient; the reconstructed 3D image of endogenous chromophores and scattering gave tumor localization in agreement with MRI. Conclusions: Imaging with a novel parallel-plate DOT breast imager that employs highly parallel, high-resolution CCD detection in the frequency-domain was demonstrated.

60 APPLIED LIFE SCIENCES↗

High-dimensional multivariate autoregressive model estimation of human electrophysiological data using fMRI priors

Multivariate autoregressive (MVAR) model estimation enables assessment of causal interactions in brain networks. However, accurately estimating MVAR models for high-dimensional electrophysiological recordings is challenging due to the extensive data requirements. Hence, the applicability of MVAR models for study of brain behavior over hundreds of recording sites has been very limited. Prior work has focused on different strategies for selecting a subset of important MVAR coefficients in the model to reduce the data requirements of conventional least-squares estimation algorithms. Here we propose incorporating prior information, such as resting state functional connectivity derived from functional magnetic resonance imaging, into MVAR model estimation using a weighted group least absolute shrinkage and selection operator (LASSO) regularization strategy. The proposed approach is shown to reduce data requirements by a factor of two relative to the recently proposed group LASSO method of Endemann et al (Neuroimage 254:119057, 2022) while resulting in models that are both more parsimonious and more accurate. The effectiveness of the method is demonstrated using simulation studies of physiologically realistic MVAR models derived from intracranial electroencephalography (iEEG) data. The robustness of the approach to deviations between the conditions under which the prior information and iEEG data is obtained is illustrated using models from data collected in different sleep stages. This approach allows accurate effective connectivity analyses over short time scales, facilitating investigations of causal interactions in the brain underlying perception and cognition during rapid transitions in behavioral state.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Increasing sensitivity and angle-of-view of mid-wave infrared detectors by integration with dielectric microspheres

We observed up to 100 times enhancement of sensitivity of mid-wave infrared photodetectors in the 2–5 μm range by using photonic jets produced by sapphire, polystyrene, and soda-lime glass microspheres with diameters in the 90–300 μm range. By finite-difference time-domain (FDTD) method for modeling, we gain insight into the role of the microspheres refractive index, size, and alignment with respect to the detector mesa. A combination of enhanced sensitivity with angle-of-view (AOV) up to 20° is demonstrated for individual photodetectors. It is proposed that integration with microspheres can be scaled up for large focal plane arrays, which should provide maximal light collection efficiencies with wide AOVs, a combination of properties highly attractive for imaging applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-D-209-01: Dosimetry of Diagnostic Work Up Mammography

Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulation of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.

60 APPLIED LIFE SCIENCES↗