Search NASA⌕ Search

SEARCH · Search NASA

Results for “imaging data”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

On-Board Patient Positioning for Head-and-Neck IMRT: Comparing Digital Tomosynthesis to Kilovoltage Radiography and Cone-Beam Computed Tomography

Purpose: High-precision intensity-modulated radiotherapy demands high patient positioning accuracy. On-board digital tomosynthesis (DTS) provides three-dimensional (3D) image guidance for daily positioning with a lower imaging dose, faster acquisition, and more geometric flexibility than 3D cone-beam computed tomography (CBCT). This clinical study evaluated DTS as a daily imaging technique for patient positioning and compared the results with 3D CBCT and two-dimensional (2D) radiography. Methods and Materials: Head and neck cancer patients undergoing intensity-modulated radiotherapy were studied. For each session, the patient was positioned using laser marks. On-board imaging data sets, including 2D kilovoltage radiographs, DTS, and CBCT, were obtained to measure the daily patient positioning variations. The mean and standard deviations of the positioning variations in the translational and rotational directions were calculated. The positioning differences among 2D radiography, DTS, and CBCT were analyzed. Results: Image data sets were collected from 65 treatment fractions for 10 patients. The systematic patient positioning variation was <0.10 cm and 1.0 deg. one dimensionally. The random variations were 0.27-0.34 cm in the translational and 0.93{sup o}-1.99{sup o} in the rotational direction. The mean vector isocenter variation was 0.48 cm. DTS with 40 deg. and 20 deg. scan angles in the coronal or sagittal directions yielded the same results for patient positioning. DTS performance was comparable to that of CBCT, with positioning differences of <0.1 cm and 0.5{sup o}. The positioning difference between 2D radiography and DTS was {approx}0.1 cm and 0.2 cm in the vertical/longitudinal and lateral directions. Conclusion: Our results have demonstrated that DTS is a comparable 3D imaging technique to CBCT for daily patient positioning of head-and-neck patients as determined by manual registration of bony anatomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Epidural anesthesia needle guidance by forward-view endoscopic optical coherence tomography and deep learning

Epidural anesthesia requires injection of anesthetic into the epidural space in the spine. Accurate placement of the epidural needle is a major challenge. To address this, we developed a forward-view endoscopic optical coherence tomography (OCT) system for real-time imaging of the tissue in front of the needle tip during the puncture. We tested this OCT system in porcine backbones and developed a set of deep learning models to automatically process the imaging data for needle localization. A series of binary classification models were developed to recognize the five layers of the backbone, including fat, interspinous ligament, ligamentum flavum, epidural space, and spinal cord. The classification models provided an average classification accuracy of 96.65%. During puncture, it is important to maintain a safe distance between the needle tip and the dura mater. Regression models were developed to estimate that distance based on the OCT imaging data. Based on the Inception architecture, our models achieved a mean absolute percentage error of 3.05% ± 0.55%. Overall, our results validated the technical feasibility of using this novel imaging strategy to automatically recognize different tissue structures and measure the distances ahead of the needle tip during the epidural needle placement.

60 APPLIED LIFE SCIENCES↗

THREE-DIMENSIONAL RADIO AND X-RAY MODELING AND DATA ANALYSIS SOFTWARE: REVEALING FLARE COMPLEXITY

Many problems in solar physics require analysis of imaging data obtained in multiple wavelength domains with differing spatial resolution in a framework supplied by advanced three-dimensional (3D) physical models. To facilitate this goal, we have undertaken a major enhancement of our IDL-based simulation tools developed earlier for modeling microwave and X-ray emission. The enhanced software architecture allows the user to (1) import photospheric magnetic field maps and perform magnetic field extrapolations to generate 3D magnetic field models; (2) investigate the magnetic topology by interactively creating field lines and associated flux tubes; (3) populate the flux tubes with user-defined nonuniform thermal plasma and anisotropic, nonuniform, nonthermal electron distributions; (4) investigate the spatial and spectral properties of radio and X-ray emission calculated from the model; and (5) compare the model-derived images and spectra with observational data. The package integrates shared-object libraries containing fast gyrosynchrotron emission codes, IDL-based soft and hard X-ray codes, and potential and linear force-free field extrapolation routines. The package accepts user-defined radiation and magnetic field extrapolation plug-ins. We use this tool to analyze a relatively simple single-loop flare and use the model to constrain the magnetic 3D structure and spatial distribution of the fast electrons inside this loop. We iteratively compute multi-frequency microwave and multi-energy X-ray images from realistic magnetic flux tubes obtained from pre-flare extrapolations, and compare them with imaging data obtained by SDO, NoRH, and RHESSI. We use this event to illustrate the tool's use for the general interpretation of solar flares to address disparate problems in solar physics.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-E-T-398: Evaluation of Radiobiological Parameters Using Serial Tumor Imaging During Radiotherapy as An Inverse Ill-Posed Problem

Purpose: Combination of serial tumor imaging with radiobiological modeling can provide more accurate information on the nature of treatment response and what underlies resistance. The purpose of this article is to improve the algorithms related to imaging-based radiobilogical modeling of tumor response. Methods: Serial imaging of tumor response to radiation therapy represents a sum of tumor cell sensitivity, tumor growth rates, and the rate of cell loss which are not separated explicitly. Accurate treatment response assessment would require separation of these radiobiological determinants of treatment response because they define tumor control probability. We show that the problem of reconstruction of radiobiological parameters from serial imaging data can be considered as inverse ill-posed problem described by the Fredholm integral equation of the first kind because it is governed by a sum of several exponential processes. Therefore, the parameter reconstruction can be solved using regularization methods. Results: To study the reconstruction problem, we used a set of serial CT imaging data for the head and neck cancer and a two-level cell population model of tumor response which separates the entire tumor cell population in two subpopulations of viable and lethally damage cells. The reconstruction was done using a least squared objective function and a simulated annealing algorithm. Using in vitro data for radiobiological parameters as reference data, we shown that the reconstructed values of cell surviving fractions and potential doubling time exhibit non-physical fluctuations if no stabilization algorithms are applied. The variational regularization allowed us to obtain statistical distribution for cell surviving fractions and cell number doubling times comparable to in vitro data. Conclusion: Our results indicate that using variational regularization can increase the number of free parameters in the model and open the way to development of more advanced algorithms which take into account tumor heterogeneity, for example, related to hypoxia.

60 APPLIED LIFE SCIENCES↗

COOL–LAMPS. III. Discovery of a 25."9 Separation Quasar Lensed by a Merging Galaxy Cluster*

In the third paper from the COOL–LAMPS Collaboration, we report the discovery of COOL J0542-2125, a gravitationally lensed quasar at z = 1.84, observed as three images due to an intervening massive galaxy cluster at z = 0.61. The lensed quasar images were identified in a search for lens systems in recent public optical imaging data and have separations on the sky up to 25farcs9, wider than any previously known lensed quasar. The galaxy cluster acting as a strong lens appears to be in the process of merging, with two subclusters separated by ~1 Mpc in the plane of the sky, and their central galaxies showing a radial velocity difference of ~1000 km s-1. Both cluster cores show strongly lensed images of an assortment of background sources, as does the region between them. A preliminary strong lens model implies masses of $M_{<250kpc} = 1.79^{+0.16}_{-0.01}$ x $10^{14} M_⊙$ and $M_{<250kpc} = 1.48^{+0.04}_{-0.10}$ x $10^{14} M_⊙$ for the east and west subclusters, respectively. This line of sight is also coincident with an ROSAT ALL-sky Survey source, centered between the two confirmed cluster halos reminiscent of other major cluster-scale mergers. Archival and new follow-up imaging show flux variability in the quasar images of up to 0.4 mag within ~1 yr, and new multicolor imaging data reveal a 2σ detection of the underlying quasar host. A lens system with this configuration offers rare opportunities for a range of future studies of both the lensed quasar and its host and the foreground cluster merger causing the lensing.

79 ASTRONOMY AND ASTROPHYSICS↗

Detection of facilities in satellite imagery using semi-supervised image classification and auxiliary contextual observables

Detecting complex targets, such as facilities, in commercially available satellite imagery is a difficult problem that human analysts try to solve by applying world knowledge. Often there are known observables that can be extracted by pixel-level feature detectors that can assist in the facility detection process. Individually, each of these observables is not sufficient for an accurate and reliable detection, but in combination, these auxiliary observables may provide sufficient context for detection by a machine learning algorithm. We describe an approach for automatic detection of facilities that uses an automated feature extraction algorithm to extract auxiliary observables, and a semi-supervised assisted target recognition algorithm to then identify facilities of interest. We illustrate the approach using an example of finding schools in Quickbird image data of Albuquerque, New Mexico. We use Los Alamos National Laboratory's Genie Pro automated feature extraction algorithm to find a set of auxiliary features that should be useful in the search for schools, such as parking lots, large buildings, sports fields and residential areas and then combine these features using Genie Pro's assisted target recognition algorithm to learn a classifier that finds schools in the image data.

99 GENERAL AND MISCELLANEOUS↗

Effect of Background Emissivity on Gas Detection in Thermal Hyperspectral Imagery

Detecting and identifying weak gaseous plumes using thermal imaging data is complicated by many factors. These include variability due to atmosphere, ground and plume temper- ature, and background clutter. This paper presents an analysis of one formulation of the physics-based radiance model, which describes at-sensor observed radiance. The background emissivity and plume/ground temperatures are isolated, and their effects on net chemical signal are described. This analysis shows that the plume’s physical state, emission or absorption, is directly dependent on the background emissivity. It then describes what conditions on the background emissivity have inhibiting effects on the net chemical signal. These claims are illustrated by analyzing synthetic hyperspectral imaging data with the Adaptive Matched Filter using four chemicals and three distinct background emissivities. Two chemicals (Carbontetrachloride and Tetraflourosilane) in the analysis had a very strong relationship with the background emissivities: they exhibited absorbance over a small range of wavenumbers and the background emissivities showed a consistent ordering at these wavenumbers. Analysis of simulated hyperspectral images containing these chemicals showed complete agreement with the analysis of the physics-based model that described when the background emissivities would have inhibiting effects on gas detection. The other chemicals considered (Ammonia and Tributylphosphate) exhibited very complex absorbance structure across the longwave infrared spectrum. Analysis of images containing these chemicals revealed that the the analysis of the physics-based model did not hold completely for these complex chemicals but did suggest that gas detection was dominated by their dominant absorbance features. These results provide some explanation of the effect of the background emissivity on gas detection and a more general exploration of gas absorbance/background emissivity variability and their effects on gas detection is warranted. i

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Physical and Chemical Morphology of Passively Sampled Environmental Films

Environmental surface films are important mediators in the fate and transport of persistent organic pollutants (POP) via largely uncharacterized mechanisms. This work presents the first analysis of the physical and chemical morphology of passively sampled environmental films. The films are developed in urban, sub-urban, and metropolitan locations for timescales ranging from 1 to 52 weeks by exposing polished silicon wafers to collect passively deposited tropospheric particulate matter. The time-dependent spatial morphology of the films is analyzed by bright-field, scanning electron, and atomic force microscopies. Time-of-flight secondary ion mass spectrometry (ToF-SIMS) imaging data are analyzed to report the film’s chemical morphology and speciation. We find that the film matrix presents an extremely complex physical and chemical system. Deposited PM sizes span six orders of magnitude (millimeter to nanometer regimes), and surface coverages range from ca. 5 % for one week films and ca. 98 % for 52 week films. We observe significant amounts of mineral dust, biogenic organics, and occasional indications of flora growth (i.e., spores). The films exhibit nanoscale surface features indicative of small particulate depositions as well as films of (semi)volatile molecules. SIMS imaging reveals diverse and sometimes segregated chemical domains of hydrocarbons, inorganics, metals, and proteinaceous macromolecules. This work presents the first spatially resolved physical and chemical surface characterization of native environmental films, beginning a study of mechanisms by which these films form, persist, and mature in the environment.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Deep optical imaging of star-forming blue early-type galaxies: Color map structures and faint features indicative of recent mergers

Blue early-type galaxies with galaxy-scale ongoing star formation are interesting targets in order to understand the stellar mass buildup in elliptical and S0 galaxies in the local Universe. We study the star-forming population of blue early-type galaxies to understand the origin of star formation in these otherwise red and dead stellar systems. The legacy survey imaging data taken with the dark energy camera in the g, r, and z bands for 55 star-forming blue early-type galaxies were examined, and g – r color maps were created. We identified low surface brightness features near 37 galaxies, faint-level interaction signatures near 15 galaxies, and structures indicative of recent merger activity in the optical color maps of all 55 galaxies. These features are not visible in the shallow Sloan Digital Sky Survey imaging data in which these galaxies were originally identified. Low surface brightness features found around galaxies could be remnants of recent merger events. The star-forming population of blue early-type galaxies could be post-merger systems that are expected to be the pathway for the formation of elliptical galaxies. We hypothesize that the star-forming population of blue early-type galaxies is a stage in the evolution of early-type galaxies. The merger features will eventually disappear, fuel for star formation will cease, and the galaxy will move to the passive population of normal early-type galaxies.

79 ASTRONOMY AND ASTROPHYSICS↗

braggedgemodeling

braggedgemodeling (bem) is an open-source Python package for modeling neutron Bragg-edge imaging. It computes the wavelength-dependent total neutron cross-section of a material (coherent and incoherent elastic, coherent and incoherent inelastic scattering, and absorption) from its crystal structure, and implements the March-Dollase texture model and the Jorgensen peak profile, supporting quantitative analysis of energy-resolved neutron imaging data (phase, stress/strain, and texture). Published in the Journal of Open Source Software (2018).

Lin, Jiao [Oak Ridge National Laboratory (ORNL), O↗

Eight ultra-faint galaxy candidates discovered in year two of the dark energy survey

We report the discovery of eight new ultra-faint dwarf galaxy candidates in the second year of optical imaging data from the Dark Energy Survey (DES). Six of these candidates are detected at high confidence, while two lower-confidence candidates are identified in regions of non-uniform survey coverage. The new stellar systems are found by three independent automated search techniques and are identified as overdensities of stars, consistent with the isochrone and luminosity function of an old and metal-poor simple stellar population. The new systems are faint (M{sub V} > −4.7 mag) and span a range of physical sizes (17 pc < r{sub 1/2} < 181 pc) and heliocentric distances (25 kpc < D{sub ⊙} < 214 kpc). All of the new systems have central surface brightnesses consistent with known ultra-faint dwarf galaxies (μ ≳ 27.5 mag arcsec{sup −2}). Roughly half of the DES candidates are more distant, less luminous, and/or have lower surface brightnesses than previously known Milky Way satellite galaxies. Most of the candidates are found in the southern part of the DES footprint close to the Magellanic Clouds. We find that the DES data alone exclude (p < 10{sup −3}) a spatially isotropic distribution of Milky Way satellites and that the observed distribution can be well, though not uniquely, described by an association between several of the DES satellites and the Magellanic system. Our model predicts that the full sky may hold ∼100 ultra-faint galaxies with physical properties comparable to the DES satellites and that 20%–30% of these would be spatially associated with the Magellanic Clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Imaging on Z LDRD: Design and Development of Self-Emission and Debris Imagers

We present an overview of the design and development of optical self-emission and debris imaging diagnostics for the Z Machine at Sandia National Laboratories. These diagnostics were designed and implemented to address several gaps in our understanding of visibly emitting phenomenon on Z and the post-shot debris environment. Optical emission arises from plasmas that form on the transmission line that delivers energy to Z loads and on the Z targets themselves; however, the dynamics of these plasmas are difficult to assess without imaging data. Addressing this, we developed a new optical imager called SEGOI (Self-Emission Gated Optical Imager) that leverages the eight gated optical imagers and two streak cameras of the Z Line VISAR system. SEGOI is a low cost, side-on imager with a 1 cm field of view and 30-50 µm spatial resolution, sensitive to green light (540-600 nm). This report outlines the design considerations and development of this diagnostic and presents an overview of the first diagnostic data acquired from four experimental campaigns. SEGOI was fielded on power flow experiments to image plasmas forming on and between transmission lines, on an inertial confinement fusion experiment called the Dynamic Screw Pinch to image low density plasmas forming on return current posts, on an experiment designed to measure the magneto Rayleigh-Taylor instability to image the instability bubble trajectory and self-emission structures, and finally on a Magnetized Liner Inertial Fusion (MagLIF) experiment to image the emission from the target. The second diagnostic developed, called DINGOZ (Debris ImagiNG on Z), was designed to improve our understanding of the post-shot debris environment. DINGOZ is an airtight enclosure that houses electronics and batteries to operate a high-speed (10-400 kfps) camera in the Z Machine center section. We report on the design considerations of this new diagnostic and present the first high-speed imaging data of the post-shot debris environment on Z.

42 ENGINEERING↗

THE KINEMATICS AND PLASMA PROPERTIES OF A SOLAR SURGE TRIGGERED BY CHROMOSPHERIC ACTIVITY IN AR11271

We observe a solar surge in NOAA AR11271 using the Solar Dynamics Observatory (SDO) Atmospheric Imaging Assembly 304 A image data on 2011 August 25. The surge rises vertically from its origin up to a height of Almost-Equal-To 65 Mm with a terminal velocity of Almost-Equal-To 100 km s{sup -1}, and thereafter falls and fades gradually. The total lifetime of the surge was Almost-Equal-To 20 minutes. We also measure the temperature and density distribution of the observed surge during its maximum rise and find an average temperature and a density of 2.0 MK and 4.1 Multiplication-Sign 10{sup 9} cm{sup -3}, respectively. The temperature map shows the expansion and mixing of cool plasma lagging behind the hot coronal plasma along the surge. Because SDO/HMI temporal image data do not show any detectable evidence of significant photospheric magnetic field cancellation for the formation of the observed surge, we infer that it is probably driven by magnetic-reconnection-generated thermal energy in the lower chromosphere. The radiance (and thus the mass density) oscillations near the base of the surge are also evident, which may be the most likely signature of its formation by a reconnection-generated pulse. In support of the present observational baseline of the triggering of the surge due to chromospheric heating, we devise a numerical model with conceivable implementation of the VAL-C atmosphere and a thermal pulse as an initial trigger. We find that the pulse steepens into a slow shock at higher altitudes which triggers plasma perturbations exhibiting the observed features of the surge, e.g., terminal velocity, height, width, lifetime, and heated fine structures near its base.

79 ASTRONOMY AND ASTROPHYSICS↗

The feasibility of a regional CTDI{sub vol} to estimate organ dose from tube current modulated CT exams

Purpose: In AAPM Task Group 204, the size-specific dose estimate (SSDE) was developed by providing size adjustment factors which are applied to the Computed Tomography (CT) standardized dose metric, CTDI{sub vol}. However, that work focused on fixed tube current scans and did not specifically address tube current modulation (TCM) scans, which are currently the majority of clinical scans performed. The purpose of this study was to extend the SSDE concept to account for TCM by investigating the feasibility of using anatomic and organ specific regions of scanner output to improve accuracy of dose estimates. Methods: Thirty-nine adult abdomen/pelvis and 32 chest scans from clinically indicated CT exams acquired on a multidetector CT using TCM were obtained with Institutional Review Board approval for generating voxelized models. Along with image data, raw projection data were obtained to extract TCM functions for use in Monte Carlo simulations. Patient size was calculated using the effective diameter described in TG 204. In addition, the scanner-reported CTDI{sub vol} (CTDI{sub vol,global}) was obtained for each patient, which is based on the average tube current across the entire scan. For the abdomen/pelvis scans, liver, spleen, and kidneys were manually segmented from the patient datasets; for the chest scans, lungs and for female models only, glandular breast tissue were segmented. For each patient organ doses were estimated using Monte Carlo Methods. To investigate the utility of regional measures of scanner output, regional and organ anatomic boundaries were identified from image data and used to calculate regional and organ-specific average tube current values. From these regional and organ-specific averages, CTDI{sub vol} values, referred to as regional and organ-specific CTDI{sub vol}, were calculated for each patient. Using an approach similar to TG 204, all CTDI{sub vol} values were used to normalize simulated organ doses; and the ability of each normalized dose to correlate with patient size was investigated. Results: For all five organs, the correlations with patient size increased when organ doses were normalized by regional and organ-specific CTDI{sub vol} values. For example, when estimating dose to the liver, CTDI{sub vol,global} yielded a R{sup 2} value of 0.26, which improved to 0.77 and 0.86, when using the regional and organ-specific CTDI{sub vol} for abdomen and liver, respectively. For breast dose, the global CTDI{sub vol} yielded a R{sup 2} value of 0.08, which improved to 0.58 and 0.83, when using the regional and organ-specific CTDI{sub vol} for chest and breasts, respectively. The R{sup 2} values also increased once the thoracic models were separated for the analysis into females and males, indicating differences between genders in this region not explained by a simple measure of effective diameter. Conclusions: This work demonstrated the utility of regional and organ-specific CTDI{sub vol} as normalization factors when using TCM. It was demonstrated that CTDI{sub vol,global} is not an effective normalization factor in TCM exams where attenuation (and therefore tube current) varies considerably throughout the scan, such as abdomen/pelvis and even thorax. These exams can be more accurately assessed for dose using regional CTDI{sub vol} descriptors that account for local variations in scanner output present when TCM is employed.

60 APPLIED LIFE SCIENCES↗

Intermittent fluctuations in the Alcator C-Mod scrape-off layer

Fluctuations in the boundary region of the Alcator C-Mod tokamak have been analyzed using gas puff imaging data. It is found that the fluctuation amplitudes in the near scrape-off layer follow a normal distribution while the far scrape-off layer fluctuations are dominated by large amplitude bursts due to radial motion of blob-like structures and have a positively skewed and flattened amplitude probability distribution. Conditional averaging of the time series reveals burst wave forms with a fast rise and slow decay and exponentially distributed burst amplitudes and waiting times. Based on this, a stochastic model of the burst dynamics is constructed. The model predicts that fluctuation amplitudes should follow a Gamma distribution and that there is a parabolic relation between the skewness and the kurtosis moments of the fluctuations. This is shown to compare favorably with the gas puff imaging data over a range of line-averaged plasma densities.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Considerations for three-dimensional image reconstruction from experimental data in coherent diffractive imaging

Diffraction before destruction using X-ray free-electron lasers (XFELs) has the potential to determine radiation-damage-free structures without the need for crystallization. This article presents the three-dimensional reconstruction of the Melbournevirus from single-particle X-ray diffraction patterns collected at the LINAC Coherent Light Source (LCLS) as well as reconstructions from simulated data exploring the consequences of different kinds of experimental sources of noise. The reconstruction from experimental data suffers from a strong artifact in the center of the particle. This could be reproduced with simulated data by adding experimental background to the diffraction patterns. In those simulations, the relative density of the artifact increases linearly with background strength. This suggests that the artifact originates from the Fourier transform of the relatively flat background, concentrating all power in a central feature of limited extent. We support these findings by significantly reducing the artifact through background removal before the phase-retrieval step. Large amounts of blurring in the diffraction patterns were also found to introduce diffuse artifacts, which could easily be mistaken as biologically relevant features. Other sources of noise such as sample heterogeneity and variation of pulse energy did not significantly degrade the quality of the reconstructions. Larger data volumes, made possible by the recent inauguration of high repetition-rate XFELs, allow for increased signal-to-background ratio and provide a way to minimize these artifacts. The anticipated development of three-dimensional Fourier-volume-assembly algorithms which are background aware is an alternative and complementary solution, which maximizes the use of data.

47 OTHER INSTRUMENTATION↗

THE SLOAN BRIGHT ARCS SURVEY: DISCOVERY OF SEVEN NEW STRONGLY LENSED GALAXIES FROM z = 0.66-2.94

We report the discovery of seven new, very bright gravitational lens systems from our ongoing gravitational lens search, the Sloan Bright Arcs Survey (SBAS). Two of the systems are confirmed to have high source redshifts z = 2.19 and z = 2.94. Three other systems lie at intermediate redshift with z = 1.33, 1.82, 1.93 and two systems are at low redshift z = 0.66, 0.86. The lensed source galaxies in all of these systems are bright, with i-band magnitudes ranging from 19.73 to 22.06. We present the spectrum of each of the source galaxies in these systems along with estimates of the Einstein radius for each system. The foreground lens in most systems is identified by a red sequence based cluster finder as a galaxy group; one system is identified as a moderately rich cluster. In total, SBAS has now discovered 19 strong lens systems in the SDSS imaging data, 8 of which are among the highest surface brightness z {approx_equal} 2-3 galaxies known.

79 ASTRONOMY AND ASTROPHYSICS↗

Attenuation-based size metric for estimating organ dose to patients undergoing tube current modulated CT exams

Purpose: Task Group 204 introduced effective diameter (ED) as the patient size metric used to correlate size-specific-dose-estimates. However, this size metric fails to account for patient attenuation properties and has been suggested to be replaced by an attenuation-based size metric, water equivalent diameter (D{sub W}). The purpose of this study is to investigate different size metrics, effective diameter, and water equivalent diameter, in combination with regional descriptions of scanner output to establish the most appropriate size metric to be used as a predictor for organ dose in tube current modulated CT exams. Methods: 101 thoracic and 82 abdomen/pelvis scans from clinically indicated CT exams were collected retrospectively from a multidetector row CT (Sensation 64, Siemens Healthcare) with Institutional Review Board approval to generate voxelized patient models. Fully irradiated organs (lung and breasts in thoracic scans and liver, kidneys, and spleen in abdominal scans) were segmented and used as tally regions in Monte Carlo simulations for reporting organ dose. Along with image data, raw projection data were collected to obtain tube current information for simulating tube current modulation scans using Monte Carlo methods. Additionally, previously described patient size metrics [ED, D{sub W}, and approximated water equivalent diameter (D{sub Wa})] were calculated for each patient and reported in three different ways: a single value averaged over the entire scan, a single value averaged over the region of interest, and a single value from a location in the middle of the scan volume. Organ doses were normalized by an appropriate mAs weighted CTDI{sub vol} to reflect regional variation of tube current. Linear regression analysis was used to evaluate the correlations between normalized organ doses and each size metric. Results: For the abdominal organs, the correlations between normalized organ dose and size metric were overall slightly higher for all three differently (global, regional, and middle slice) reported D{sub W} and D{sub Wa} than they were for ED, but the differences were not statistically significant. However, for lung dose, computed correlations using water equivalent diameter calculated in the middle of the image data (D{sub W,middle}) and averaged over the low attenuating region of lung (D{sub W,regional}) were statistically significantly higher than correlations of normalized lung dose with ED. Conclusions: To conclude, effective diameter and water equivalent diameter are very similar in abdominal regions; however, their difference becomes noticeable in lungs. Water equivalent diameter, specifically reported as a regional average and middle of scan volume, was shown to be better predictors of lung dose. Therefore, an attenuation-based size metric (water equivalent diameter) is recommended because it is more robust across different anatomic regions. Additionally, it was observed that the regional size metric reported as a single value averaged over a region of interest and the size metric calculated from a single slice/image chosen from the middle of the scan volume are highly correlated for these specific patient models and scan types.

60 APPLIED LIFE SCIENCES↗