Search NASA⌕ Search

SEARCH · Search NASA

Results for “impact ionization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Ultraviolet and optical spectroscopy of the R Aquarii symmetrical jet

The first ultraviolet spectrum of the southwest (SW) component of the symmetrical jet in the R Aquarii binary system has been obtained in the range 1200-2000 A with the IUE. These results are compared to more encompassing spectra of the central H II region taken at the same time and also similar spectra of the northeast (NE) jet component obtained six months earlier. Moreover, optical spectra of both the NE and SW jet components in the range 3400-9800 A were obtained within about 6 months and about 1 month, respectively, of the ultraviolet spectra. These highly complementary observations argue that excitation of the symmetrical jet may be due to shock excitation as the jet components overtake and impact the previously ionized material associated with the expanding inner nebulosity. The problems with this shock model as well as problems with competing photoionization models are discussed. It is suggested that the jet components were ejected less than 90 years ago.

Hollis, J. M.↗

Environmental interactions of the Space Station Freedom electric power system

The Space Station Freedom will be operating in the Low Earth Orbit (LEO) environment. LEO environment operation results in different potential interactions with the Space Station systems including the Electric Power Systems (EPS). These potential interactions result in environmental effects which include neutral species effects such as atomic oxygen erosion, effects of micrometeroid and orbital debris impacts, plasma effects, ionizing radiation effects, and induced contamination degradation effects. The EPS design and its interactions with the LEO environment are described. The results of analyses and testing programs planned and performed thus far to resolve the environmental concerns related to the EPS and its function in the LEO environment are discussed.

Nahra, Henry K.↗

Characterization of polymer decomposition products by laser desorption mass spectrometry

Laser desorption mass spectrometry has been used to characterize the ash-like substances formed on the surfaces of polymer matrix composites (PMC's) during exposure on LDEF. In an effort to minimize fragmentation, material was removed from the sample surfaces by laser desorption and desorbed neutrals were ionized by electron impact. Ions were detected in a time-of-flight mass analyzer which allows the entire mass spectrum to be collected for each laser shot. The method is ideal for these studies because only a small amount of ash is available for analysis. Three sets of samples were studied including C/polysulfone, C/polyimide and C/phenolic. Each set contains leading and trailing edge LDEF samples and their respective controls. In each case, the mass spectrum of the ash shows a number of high mass peaks which can be assigned to fragments of the associated polymer. These high mass peaks are not observed in the spectra of the control samples. In general, the results indicate that the ash is formed from decomposition of the polymer matrix.

Pallix, Joan B.↗

Investigation of Possible Electromagnetic Disturbances caused by Spacecraft-Plasma Interactions at 4 Radii

The proposed Small Solar Probe mission features a close approach to the sun with a perihelion of 4 radii. Carbon molecules emitted from the spacecraft's heat shield will become ionized by electron impact and photoionization. The newly created ions and electrons may generate electromagnetic and electrostatic plasma waves which are possible sources of interference with in-situ plasma measurements.

computer simulations↗

Mass Spectrometers in Space!

Exploration of our solar system over several decades has benefitted greatly from the sensitive chemical analyses offered by spaceflight mass spectrometers. When dealing with an unknown environment, the broadband detection capabilities of mass analyzers have proven extremely valuable in determining the composition and thereby the basic nature of space environments, including the outer reaches of Earth s atmosphere, interplanetary space, the Moon, and the planets and their satellites. Numerous mass analyzer types, including quadrupole, monopole, sector, ion trap, and time-of-flight have been incorporated in flight instruments and delivered robotically to a variety of planetary environments. All such instruments went through a rigorous process of application-specific development, often including significant miniaturization, testing, and qualification for the space environment. Upcoming missions to Mars and opportunities for missions to Venus, Europa, Saturn, Titan, asteroids, and comets provide new challenges for flight mass spectrometers that push to state of the art in fundamental analytical technique. The Sample Analysis at Mars (SAM) investigation on the recently-launch Mars Science Laboratory (MSL) rover mission incorporates a quadrupole analyzer to support direct evolved gas as well as gas chromatograph-based analysis of martian rocks and atmosphere, seeking signs of a past or present habitable environment. A next-generation linear ion trap mass spectrometer, using both electron impact and laser ionization, is being incorporated into the Mars Organic Molecule Analyzer (MOMA) instrument, which will be flown to Mars in 2018. These and other mass spectrometers and mission concepts at various stages of development will be described.

Brinckerhoff, William B.↗

The Peregrine Ion Trap Mass Spectrometer (PITMS) Investigation Development and Pre-Flight Planning

The Peregrine Ion Trap Mass Spectrometer (PITMS) is a mass spectrometer instrument that operated during the Astrobotic Peregrine Mission-1 as part of the NASA Commercial Lunar Payload Services (CLPS) initiative. This paper describes the instrument and investigation design, development, and planning conducted by the PITMS team consisting of a successful partnership between NASA Goddard Space Flight Center (GSFC), The Open University (OU), NASA, and ESA. PITMS was designed to measure the abundance and temporal variability of volatile species in the near-surface lunar exosphere from a landed platform on the lunar surface. The PITMS instrument consisted of an ESA-provided Exospheric Mass Spectrometer (EMS; including sensor, electronics, controller, power supply boards) and a GSFC wrapper that provided structural elements, thermal control, and a deployable dust cover. PITMS was designed to operate as a passive sampler, where ambient gases would enter PITMS through an aperture, diffuse around the mass analyzer cavity, become ionized by electron impact and trapped in a radiofrequency field, then sequentially released to a detector to build a mass spectrum. PITMS was capable of measuring species with a massto-charge ratio (m/z) from 10 to 150 Da, with a mass resolution of approximately 0.5 amu. The PITMS science investigation was planned to be operated by GSFC with an international team of scientists. Though the mission did not achieve its lunar landing, information about the PITMS instrument and planning is provided to be able to understand and effectively use data that will be forthcoming from the investigation.

Barbara Cohen↗

Measurement and calculation of the Stark-broadening parameters for the resonance lines of singly ionized calcium and magnesium.

The electron-impact-broadened profiles of the resonance lines of singly ionized calcium and magnesium have been measured using an electromagnetically driven shock tube and a rapid-scanning Fabry-Perot spectrometer. For an electron density of 10 to the 17th power per cu cm and a temperature of 19,000 K, we found the Lorentzian half-width of the Ca+ line to be 0.086 A plus or minus 10% and of the Mg+ line to be 0.044 A plus or minus 10%. Using the quantum-mechanical theory of Barnes and Peach and our semiclassical calculation for the calcium lines, we found that the temperature dependence of the theoretical curves is close to that measured, although both theories predict actual values which are somewhat large.

Jones, W. W.↗

Cross sections for the production of energetic cations by electron impact on N2 and CO2

Dissociative ionization cross sections for the production of singly charged energetic ions by electron impact on N2 and CO2 have been measured. The ions were divided into two groups: one with energies less than 1 eV and the other with energies greater than 1 eV. The ions detected were N+ from N2 and C+, O+, and CO+ from CO2. The electron impact energy range, and cross section data on ions is given.

energetic cations↗

Ionization cross-sections for the production of positive ions from H2O by electron impact

Water is present in the atmospheres of 6 of the 9 planets. Cross section values for the direct and partial ionization of H2O by electron impact have been measured and compared with previously published data. The present measurements have been carried out from thresholds to 1 KeV by utilizing a crossed electron beam and molecular beam collision geometry and an improved ion extraction technique.

planetary atmospheres↗

Design and Development of 256x256 Linear Mode Low-Noise Avalanche Photodiode Arrays

A larger format photodiode array is always desirable for many LADAR imaging applications. However, as the array format increases, the laser power or the lens aperture has to increase to maintain the same flux per pixel thus increasing the size, weight and power of the imaging system. In order to avoid this negative impact, it is essential to improve the pixel sensitivity. The sensitivity of a short wavelength infrared linear-mode avalanche photodiode (APD) is a delicate balance of quantum efficiency, usable gain, excess noise factor, capacitance, and dark current of APD as well as the input equivalent noise of the amplifier. By using InA1As as a multiplication layer in an InP-based APD, the ionization coefficient ratio, k, is reduced from 0.40 (lnP) to 0.22, and the excess noise is reduced by about 50%. An additional improvement in excess noise of 25% was achieved by employing an impact-ionization-engineering structure with a k value of 0.15. Compared with the traditional InP structure, about 30% reduction in the noise-equivalent power with the following amplifier can be achieved. Spectrolab demonstrated 30-um mesa APD pixels with a dark current less than 10 nA and a capacitance of 60 fF at gain of 10. APD gain uninformity determines the usable gain of most pixels in an array, which is critical to focal plane array sensitivity. By fine tuning the material growth and device process, a break-down-voltage standard deviation of 0.1 V and gain of 30 on individual pixels were demonstrated in our 256x256 linear-mode APD arrays.

Yuan, Ping↗

Initial results of positron ionization mass spectrometry

The use of monoenergetic positrons for the ionization of organic molecules in the gas phase is described. The ionic products are analyzed with a time-of-flight mass spectrometer and detected to produce a mass spectrum. The ionization mechanisms which can be studied in this way include positron impact at energies above the ionization limit of the target molecules, positronium formation in the Ore gap energy range, and positron attachment at energies less than 1eV. The technique of positron ionization mass spectrometry (PIMS) may have analytical utility in that chemical selectivity is observed for one or more of these processes.

Donohue, D. L.↗

Can quasars ionize the intergalactic medium?

The intergalactic environmental impact of quasars is studied in the light of recent QSO observations, addressing in particular whether QSOs can ionize the IGM at z greater than 3.0. After deriving the expansion law for cosmological ionization fronts in a Friedmann universe, it is investigated whether the QSO population is sufficient for these ionized regions to overlap by z of roughly 3.5. The effects of cosmological I-fronts on Lyman-alpha clouds in QSO absorption spectra are discussed.

Donahue, Megan↗

Ejected electron distributions.

Differential cross sections for secondary electron production in atomic ionization by charged particle impact, using classical binary encounter approximation

Garcia, J. D.↗

The Addition of EI/CI Capability to the Mattauch-herzog Spectrograph with EOID

A modification was made to the Mattauch-Herzog Spectrograph with an electro-optical ion detector (EOID) previously designed and constructed, so that it would be capable of operating not only in the electron-impact (EI) mode of ionization, but also in the chemical ionization (CI) mode. This modification necessitated an effort in three specific design areas: (1) sample inlet; (2) ion source and analyzer regions; and (3) the pumping system. In addition, an appropriate electronics package had to be designed to control and operate the combined EI/CI source.

Fergusson, G. J.↗