Search NASA⌕ Search

SEARCH · Search NASA

Results for “inexpensive”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Apparatus for remote handling of materials

Apparatus for remote handling of materials are described. A closed housing is provided with first and second containers and first and second reservoirs for holding materials to be mixed. The materials are transferable from the reservoirs to the first container where they are mixed. The mixed materials are then conveyed from the first container to the second container preferably by dumping the mixed materials into a funnel positioned over the second container. The second container is then moved to a second position for analysis of the mixed materials. For example, the materials may be ignited and the flame analyzed. Access, such as a sight port, is provided in the housing at the analysis position. The device provides a simple and inexpensive apparatus for safely mixing a pyrophoric material and an oxidizer which together form a thermite type mixture that burns to produce a large quantity of heat and light.

Kimball, R. B.↗

Spacelab soft mockup comparative evaluation

An assessment of two proposed Spacelab configurations with diameters of 14 and 12 feet was conducted by using two inexpensive wooden mockups containing cardboard fixtures. Also examined was an alternate mounting arrangement for the 12-foot diameter configuration, taking advantage of conforming equipment racks to the cylinder walls. A volume comparison of the three configurations was made using a life sciences payload which is considered to be one of the more voluminous payloads. It was found that crew volume in the 12-foot baseline configuration appeared marginal for the life sciences payload, especially where crewmen were engaged in activities with competing demands. The 12-foot configurations of life sciences payloads offered little margin for stowage or equipment growth. Increased demands would necessitate longer module lengths. Similar results could be expected with other large volume payloads.

Watters, H.↗

Photomultiplier circuit including means for rapidly reducing the sensitivity thereof

A simple, reliable and inexpensive control circuit is described for rapidly reducing the bias voltage across one or more of the dynode stages of a photomultiplier, to substantially decrease its sensitivity to incoming light at those times where excess light intensity might damage the tube. The control circuit comprises a switching device, such as a silicon controlled rectifier (SCR), coupled between a pair of the electrodes in the tube, preferably the cathode and first dynode, or the first and second dynodes, the switching device operating in response to a trigger pulse applied to its gate to short circuit the two electrodes. To insure the desired reduction in sensitivity, two switching stages, the devices be employed between two of the electrode stages, the devices being operated simultaneously to short circuit both stages.

Mcclenahan, J. O.↗

Steady state thermal radiometers

A radiometer is described operating in a vacuum under steady state conditions. The front element is an aluminum sheet painted on the outer side with black or other absorptive material of selected characteristics. A thermocouple is bonded to the inner side of the aluminum sheet. That is backed by highly insulative layers of glass fiber and crinkled, aluminized Mylar polyester. Those layers are backed with a sturdy, polyester sheet, and the entire lamination is laced together by nylon cords. The device is highly reliable in that it does not drift out of calibration, and is significantly inexpensive.

Loose, J. D.↗

Stress wave riveting

The stress wave riveter deforms the rivet material by a high amplitude stress wave. Thus, the entire rivet is set in motion radially. The rivet expands rapidly and impacts the hole surface before the rivet tail begins to form. Unlike the oversqueezed rivets, therefore, it sets up uniform interference without distortion in the skins. Furthermore, the radial velocity is so high (over 200 in./sec) that upon impact with the hole surface it deforms the surface plastically. This is especially effective in aluminum skins. Thus the SWR combines the advantages of plastically deforming the hole and the economic advantage of a relatively nonprecision hole and inexpensive rivets like those used in oversqueezing. The additional advantage SWR offers is that it is a portable tool.

Leftheris, B. P.↗

A magnetic field measurement technique using a miniature transducer

The development, fabrication, and application of a magnetometer are described. The magnetometer has a miniature transducer and is capable of automatic scanning. The magnetometer described here is capable of detecting static magnetic fields as low as 1.6 A/m and its transducer has an active area 0.64 mm by 0.76 mm. Thin and rugged, the transducer uses wire, 0.05 mm in diameter, which is plated with a magnetic film, enabling measurement of transverse magnetic fields as close as 0.08 mm from a surface. The magnetometer, which is simple to operate and has a fast response, uses an inexpensive clip-on milliammeter (commonly found in most laboratories) for driving and processing the electrical signals and readout. A specially designed transducer holding mechanism replaces the XY recorder ink pen; this mechanism provides the basis for an automatic scanning technique. The instrument has been applied to the measurements of magnetic fields arising from remanent magnetization in experimental plated-wire memory planes and regions of magnetic activity in geological rock specimens.

Fales, C. L., Jr.↗

Use of hexafluoroethane to simulate the inviscid real-gas effects on blunt entry vehicles

Results are presented of an experimental and theoretical investigation of the use of equilibrium hexafluoroethane C2F6 as an undissociated test gas in a wind tunnel to simulate the inviscid aerodynamic characteristics of blunt bodies in high-speed flight where dissociation occurs. The results indicate that the use of C2F6 as a test gas in wind tunnels is a practical and relatively simple and inexpensive method of obtaining test conditions with large normal-shock density ratios. Equations for the thermodynamic and transport properties of C2F6 are also included.

Hunt, J. L.↗

Mars physical parameters as determined from Mariner 9 observations of the natural satellites

Derivation of values for the Mars gravity field, as well as the mass and spin axis direction, by processing combined radio and optical data taken with the Mariner 9 spacecraft. The optical data consists of 62 TV photographs of Phobos and Deimos taken during the Mars orbiting phase of Mariner 9. The radio data consists of apoapsis state vectors obtained from 195 one-revolution fits of the Doppler data. A first-order analytic theory is used to model both the satellites and the spacecraft's motion. However, the shallow resonance condition of Mariner 9's orbit necessitated development of a partial second-order theory to model the long-period perturbations which derive from Mars even-order tesseral harmonics. Use of an analytic theory allows rapid and inexpensive processing of both data types simultaneously. The results are in good agreement with those previously published from Mariner 9 Doppler and landmark data.

Born, G. H.↗

The advanced OPLE for search and rescue

Recent technological advances have made it possible to develop an advanced OMEGA position location experiment for a global search and rescue application. This application generated some new problem areas such as the OMEGA lane ambiguity, random access, location accuracy, real time processing, and size and weight of the Search and Rescue Communication (SARCOM). This experiment will demonstrate the feasibility of instantaneous alarm and position location by using a relatively inexpensive, battery operated, three-pound package. This package can transmit the alarm and position through a synchronous satellite to a search and rescue station in less than three minutes.

Morakis, J. C.↗

A transmission oscillator ultrasonic spectrometer

A continuous wave ultrasonic instrument capable of measuring very small changes in acoustic attenuation and phase velocity is described. This transmission oscillator ultrasonic spectrometer (TOUS) exhibits high sensitivity because it oscillates marginally. In spite of this high sensitivity, the TOUS system is relatively simple, compact, and inexpensive. These features suggest that the TOUS is suitable not only for precise laboratory measurements of the physical properties of materials, but also for field applications in nondestructive testing.

Conradi, M. S.↗

Video systems for real-time oil-spill detection

Three airborne television systems are being developed to evaluate techniques for oil-spill surveillance. These include a conventional TV camera, two cameras operating in a subtractive mode, and a field-sequential camera. False-color enhancement and wavelength and polarization filtering are also employed. The first of a series of flight tests indicates that an appropriately filtered conventional TV camera is a relatively inexpensive method of improving contrast between oil and water. False-color enhancement improves the contrast, but the problem caused by sun glint now limits the application to overcast days. Future effort will be aimed toward a one-camera system. Solving the sun-glint problem and developing the field-sequential camera into an operable system offers potential for color 'flagging' oil on water.

Millard, J. P.↗

Method for producing a uniform, low Reynolds number jet

In one attempt to produce a simple inexpensive nozzle, a 2-in. diam plate with 37 holes was investigated (Stadler, 1960), anticipating that the small jets emanating from the plate would combine to form a uniform stream. This experiment was unsuccessful because a uniform flow was not established until the flow had progressed many nozzle diameters downstream. However, an extension of this concept to a much larger number of very small jets, viz., a porous plate, did provide a method for producing a uniform, low Reynolds number jet almost immediately downstream of the nozzle (Greene, 1973). The method is described and some typical jet velocity profiles for nozzle Reynolds numbers from 50 to 1000 are given.

Greene, G. C.↗

Image reproduction with interactive graphics

Software application or development in optical image digital data processing requires a fast, good quality, yet inexpensive hard copy of processed images. To achieve this, a Cambo camera with an f 2.8/150-mm Xenotar lens in a Copal shutter having a Graflok back for 4 x 5 Polaroid type 57 pack-film has been interfaced to an existing Adage, AGT-30/Electro-Mechanical Research, EMR 6050 graphic computer system. Time-lapse photography in conjunction with a log to linear voltage transformation has resulted in an interactive system capable of producing a hard copy in 54 sec. The interactive aspect of the system lies in a Tektronix 4002 graphic computer terminal and its associated hard copy unit.

Buckner, J. D.↗

Fourier waveform analyzer

Real-time Fourier analysis is provided by "bucket brigade' charge-transfer shift register. Device is small, inexpensive integrated circuit which does analog-to-digital-to-analog conversion, data processing, and time delay.

Sutton, J. F.↗

Cryogenic line insulation made from prefabricated polyurethane shells

Prefabricated polyurethane foam insulation is inexpensive and easily installed on cryogenic lines. Insulation sections are semicircular half shells. Pair of half shells is placed to surround cryogenic line. Cylindrically-shaped knit sock is pulled over insulation then covered with polyurethane resin to seal system.

Lerma, G.↗