Search NASA⌕ Search

SEARCH · Search NASA

Results for “infusion”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Sympathoadrenal responses to cold and ketamine anesthesia in the rhesus monkey

The effect of cold exposure on the sympathoadrenal system is investigated in eight adult rhesus monekys with and without ketamine anesthesia. It is found that a 3 hr cold exposure (12 c) was associated with a 175 percent increase above control levels of norepinephrine (NE) and a 100 percent increase in epinephrine (E). Also observed were decreases in the core temperature, mean skin temperature, and mean body temperature. No change in the plasma levels of NE and E from the control values was found during continuous infusion of ketamine; while the core temperature, mean skin temperature, and mean body temperature all showed greater declines with the addition of ketamine infusion to the cold exposure. Water exposure (28 C) under ketamine anesthesia resulted in a reduction of the core temperature to 33 C within 1 hr. Plasma levels of NE and E were found to be unchanged from control values at core temperatures of 35 and 33 C. It is concluded that the administration of ketamine abolishes both the thermoregulatory response and the catecholamine response to acute cold exposure.

Kolka, M. A.↗

Vasopressin release induced by water deprivation - Effects of centrally administered saralasin

Uncertainty exists as to whether endogenous angiotensin activates brain mechanisms controlling vasopressin (AVP) secretion during dehydration. Various doses of saralasin were injected into a lateral cgrebroventricle (IVT) of conscious, male rats deprived of water for 48 h. The rats were killed at different times. The concentration of AVP in the plasma p(AVP), measured by radioimmunoassay, was unaffected by saralasin. IVT pretreatment with 1-Sar-8-Ile-angiotensin II blocked maximal AVP release by IVT angiotensin, but this pretreatment did not reduce p(AVP) after 24, 48 or 72 hr water deprivation. A 3-hour continuous IVT infusion of CSF or saralasin (10 micrograms/hour) into 48-hour water-deprived rats revealed equivalent p(AVP) concentration and urine volumes. When the infusions were continued for 3 h more with water available, control and saralasin-treated rats: (1) drank at similar rates, (2) excreted similar amounts of urine, and (3) reduced their p(AVP) concentration levels to the same extent. IVT saralasin did not affect p(AVP) concentration of rats dehydrated with hypertonic NaCl. Combined IVT saralasin and atropine reduced p(AVP) concentration of 48-hour water deprived rats about 30 percent (p less than 0.05). It is concluded that redundancy exists for sensing, integrating and releasing vasopressin in dehydrated rats.

Keil, L. C.↗

Applications of aerospace technology in biology and medicine

Utilization of National Aeronautics and Space Administration (NASA) technology in medicine is discussed. The objective is best obtained by stimulation of the introduction of new or improved commercially available medical products incorporating aerospace technology. A bipolar donor/recipient model of medical technology transfer is presented to provide a basis for the team's methodology. That methodology is designed to: (1) identify medical problems and NASA technology that, in combination, constitute opportunities for successful medical products; (2) obtain the early participation of industry in the transfer process; and (3) obtain acceptance by the medical community of new medical products based on NASA technology. Two commercial transfers were completed: the Stowaway, a lightweight wheelchair that provides mobility for the disabled and elderly in the cabin of commercial aircraft, and Micromed, a portable medication infusion pump for the reliable, continuous infusion of medications such as heparin or insulin. The marketing and manufacturing factors critical to the commercialization of the lightweight walker incorporating composite materials were studied. Progress was made in the development and commercialization of each of the 18 currently active projects.

Bass, B.↗

The Role of Vitamin D in the Bone Changes Associated with Simulated Weightlessness

The role of vitamin D in the change in bone metabolism was examined. The serum concentrations in rats sacrificed after 2, 5, 7, 10, 12 and 15 days of suspension was measured. Between days 1 and 5 of suspension and then gradually decreased towards normal between days 5 and 15. The time course of the changes in the circulating concentrations of 1,25(OH)2D and 24,25(OH)2D mirror almost precisely the changes in bone metabolism. The relationship between the changes in vitamin D metabolism and bone metabolism is investigated. Whether the bone changes are due to the change in serum concentration of 1,25(OH)2D or the changes in bone formation causing a reduction in Ca flux out of the serum pool and thereby suppressing 1,25(OH)2D production is examined. It is found that suspension had no effect on hormone concentration in the 1,25(OH)2D infused animals. Nevertheless, both vehicle and 1,25(OH)2D infused suspended rats exhibited the same reduction in bone mineral, and uptake of (45)Ca. It is suggested that the transitory reduction in circulating 1,25(OH)2D during suspension is not likely to cause the abnormalities in bone metabolism but rather that the changes in bone metabolism are primary and cause the fall in serum 1,25(OH)2D concentration. This supports the hypothesis that the metabolic abnormalities in bone associated with simulated weightlessness are due to the direct effect of unweighting on the bone.

Halloran, B. P.↗

Transpulmonary passage of venous air emboli

Twenty-seven paralyzed anesthetized dogs were embolized with venous air to determine the effectiveness of the pulmonary vasculature for bubble filtration or trapping. Air doses ranged from 0.05 to 0.40 ml/kg min in 0.05-ml increments with ultrasonic Doppler monitors placed over arterial vessels to detect any microbubbles that crossed the lungs. Pulmonary vascular filtration of the venous air infusions was complete for the lower air doses ranging from 0.05 to 0.30 ml/kg min. When the air doses were increased to 0.35 ml/kg min, the filtration threshold was exceeded with arterial spillover of bubbles occurring in 50 percent of the animals and reaching 71 percent for 0.40 ml/kg min. Significant elevations were observed in pulmonary arterial pressure and pulmonary vascular resistance. Systemic blood pressure and cardiac output decreased, whereas left ventricular end-diastolic pressure remained unchanged. The results indicate that the filtration of venous bubbles by the pulmonary vasculature was complete when the air infusion rates were kept below a threshold value of 0.30 ml/kg min.

Butler, B. D.↗

Role of carbonic anhydrase in bone - Partial inhibition of disuse atrophy of bone by parenteral acetazolamide

The effectiveness of orally and subcutaneously administered acetazolamide sodium in preventing denervation-induced bone loss in rats is examined. Male Sprague-Dawley rats were treated with acetazolamide either orally by incorporation of 0.2, 0.5, or 1.5 percent concentrations in their diet for 15 days, or subcutaneously by either injection of 0.5 ml/rat of a solution containing either 20 or 100 mg/ml of the drug twice daily for 15 days or by continuous infusion of 5, 50, 500, or 1000 mg/ml of acetazolamide sodium for 8 days using an osmotic minipump. The effects of acetazolamide on body weight, food consumption, and plasma calcium content are evaluated. It is observed that parenteral administration is equally effective as oral administration in partially preventing denervation-induced bone mass changes. The data reveal that approximately 50 percent protection occurs with daily doses of 1094, 129, and 8 mg/kg body weight for the oral, subcutaneous injection, and subcutaneous infusion methods, respectively.

Kenny, A. D.↗

Late Wenlock (middle Silurian) bio-events: Caused by volatile boloid impact/s

Late Wenlockian (late mid-Silurian) life is characterized by three significant changes or bioevents: sudden development of massive carbonate reefs after a long interval of limited reef growth; sudden mass mortality among colonial zooplankton, graptolites; and origination of land plants with vascular tissue (Cooksonia). Both marine bioevents are short in duration and occur essentially simultaneously at the end of the Wenlock without any recorded major climatic change from the general global warm climate. These three disparate biologic events may be linked to sudden environmental change that could have resulted from sudden infusion of a massive amount of ammonia into the tropical ocean. Impact of a boloid or swarm of extraterrestrial bodies containing substantial quantities of a volatile (ammonia) component could provide such an infusion. Major carbonate precipitation (formation), as seen in the reefs as well as, to a more limited extent, in certain brachiopods, would be favored by increased pH resulting from addition of a massive quantity of ammonia into the upper ocean. Because of the buffer capacity of the ocean and dilution effects, the pH would have returned soon to equilibrium. Major proliferation of massive reefs ceased at the same time. Addition of ammonia as fertilizer to terrestrial environments in the tropics would have created optimum environmental conditions for development of land plants with vascular, nutrient-conductive tissue. Fertilization of terrestrial environments thus seemingly preceded development of vascular tissue by a short time interval. Although no direct evidence of impact of a volatile boloid may be found, the bioevent evidence is suggestive that such an impact in the oceans could have taken place. Indeed, in the case of an ammonia boloid, evidence, such as that of the Late Wenlockian bioevents may be the only available data for impact of such a boloid.

Berry, W. B. N.↗

Characterization of blood drawn rapidly for use in blood volume expansion studies: An animal model for simulated weightlessness

It was demonstrated that up to 8ml of blood can be drawn from donar rats without significantly increasing volume and stress sensitive hormones, and thus can be used for volume expansion studies. Infusion of whole blood allows more physiological changes that can be seen with volume expansion by saline or other ionic solutions. The infusion of whole blood to induce hypervolemia may provide an improved model to study the fluid balance and control mechanisms operative in weightlessness. Blood samples were drawn as quickly as possible from femoral artery catheters chronically implanted in Sprague Dawley rats and analyzed for hematocrit, plasma sodium, potassium, osmolality, corticosterone, epinepherine, norepinephrine, and vasopressin. The levels were found to be comparable to those of normal rats.

Chenault, V. Michelle↗

In-flight demonstration of the Space Station Freedom Health Maintenance Facility fluid therapy system (E300/E05)

The Space Station Freedom (SSF) Health Maintenance Facility (HMF) will provide medical care for crew members for up to 10 days. An integral part of the required medical care consists of providing intravenous infusion of fluids, electrolyte solutions, and nutrients to sustain an ill or injured crew member. In terrestrial health care facilities, intravenous solutions are normally stored in large quantities. However, due to the station's weight and volume constraints, an adequate supply of the required solutions cannot be carried onboard SSF. By formulating medical fluids onboard from concentrates and station water as needed, the Fluid Therapy System (FTS) eliminates weight and volume concerns regarding intravenous fluids. The first full-system demonstration of FTS is continuous microgravity will be conducted in Spacelab-Japan (SL-J). The FTS evaluation consists of two functional objectives and an in-flight demonstration of intravenous administration of fluids. The first is to make and store sterile water and IV solutions onboard the spacecraft. If intravenous fluids are to be produced in SSF, successful sterilization of water and reconstituting of IV solutions must be achieved. The second objective is to repeat the verification of the FTS infusion pump, which had been performed in Spacelab Life Sciences - 1 (SLS-1). during SLS-1, the FTS IV pump was operated in continuous microgravity for the first time. The pump functioned successfully, and valuable knowledge on its performance in continuous microgravity was obtained. Finally, the technique of starting an IF in microgravity will be demonstrated. The IV technique requires modifications in microgravity, such as use of restraints for equipment and crew members involved.

Lloyd, Charles W.↗

Body position does not affect the hemodynamic response to venous air embolism in dogs

Current therapy for massive venous air embolism (VAE) includes the use of the left lateral recumbent (LLR) position. This recommendation is based on animal studies, conducted 50 years ago, which looked primarily at survival. Little is known, however, about the concomitant hemodynamic response after VAE in various body positions. The purpose of this study was to investigate the hemodynamic and cardiovascular changes in various body positions after VAE. Twenty-two mechanically ventilated supine mongrel dogs received a venous air infusion of 2.5 mL/kg at a rate of 5 mL/s. One minute after the infusion, 100% oxygen ventilation was commenced and the body position of the dogs was changed to either the LLR (n = 6), the LLR with the head 10 deg down (LLR-10 deg; n = 6) or the right lateral recumbent (RLR; n = 5) position. Five dogs were maintained in the supine position (SUP; n = 5). One dog died in every group except in the SUP group, where all the dogs recovered. There were no significant differences among the various body positions in terms of heart rate, mean arterial pressure, pulmonary artery pressure, central venous pressure, left ventricular end-diastolic pressure, or cardiac output. The acute hemodynamic changes occurring during the first 5-15 min after VAE recovered to 80% of control within 60 min. Our data suggest that body repositioning does not influence the cardiovascular response to VAE. Specifically, our data do not support the recommendation of repositioning into the LLR position for the treatment of VAE.

Mehlhorn, Uwe↗

Mission to Planet Earth Strategic Enterprise Plan 1996-2002

Mission to Planet Earth's (MTPE's) first Strategic Enterprise Plan, issued in May 1995, defined the Agency's major goals and objectives as well as constraints. This update of the Strategic Enterprise Plan identifies the following major changes: a focused Science Research Plan that integrates space-based and in situ observational critical science to address critical science uncertainties; a technology infusion plan to reduce the cost of future missions; a series of flight opportunities to infuse new science into the overall program; and a tighter coupling between NASA and NOAA to reduce costs and to improve the overall program. Three important new initiatives are also under development and are described briefly in this plan: MTPE Education Strategy, MTPE Commercial Strategy, and an emerging concept for an Integrated Global Observing Strategy. This first update to the MTPE Strategic Enterprise Plan captures these new developments, and takes a significant step forward in planning this complex Earth system science endeavor. The plan and other information on MTPE may be viewed via the Internet at http://www.hq.nasa.gov/office/mtpe/.

Source record↗

Method for Ultrasonic Imaging and Device for Performing the Method

A method for ultrasonic imaging of interior structures and flaws in a test specimen with a smooth or irregular contact surfaces, in which an ultrasonic transducer is coupled acoustically to the contact surface via a plurality of ultrasonic wave guides with equal delay times. The wave guides are thin and bendable, so they adapt to variations in the distance between the transducer and different parts of the contact surface by bending more or less. All parts of the irregular contact surface accordingly receive sound waves that are in phase, even when the contact surface is irregular, so a coherent sound wave is infused in the test specimen. The wave guides can be arranged in the form of an ultrasonic brush, with a flat head for coupling to a flat transducer, and free bristles that can be pressed against the test specimen. By bevelling the bristle ends at a suitable angle, shear mode waves can be infused into the test specimen from a longitudinal mode transducer.

Madaras, Eric I.↗

Demonstration of a Probabilistic Technique for the Determination of Economic Viability of Very Large Transport Configurations

Over the past few years, modem aircraft design has experienced a paradigm shift from designing for performance to designing for affordability. This report contains a probabilistic approach that will allow traditional deterministic design methods to be extended to account for disciplinary, economic, and technological uncertainty. The probabilistic approach was facilitated by the Fast Probability Integration (FPI) technique; a technique which allows the designer to gather valuable information about the vehicle's behavior in the design space. This technique is efficient for assessing multi-attribute, multi-constraint problems in a more realistic fashion. For implementation purposes, this technique is applied to illustrate how both economic and technological uncertainty associated with a Very Large Transport aircraft concept may be assessed. The assessment is evaluated with the FPI technique to determine the cumulative probability distributions of the design space, as bound by economic objectives and performance constraints. These distributions were compared to established targets for a comparable large capacity aircraft, similar in size to the Boeing 747-400. The conventional baseline configuration design space was determined to be unfeasible and marginally viable, motivating the infusion of advanced technologies, including reductions in drag, specific fuel consumption, wing weight, and Research, Development, Testing, and Evaluation costs. The resulting system design space was qualitatively assessed with technology metric "k" factors. The infusion of technologies shifted the VLT design into regions of feasibility and greater viability. The study also demonstrated a method and relationship by which the impact of new technologies may be assessed in a more system focused approach.

Mavris, Dimitri N.↗

Corticosterone, but not Glucose, Treatment Enables Fasted Adrenalectomized Rats to Survive Moderate Hemorrhage

Fed adrenalectomized rats survive the stress of hemorrhage and hypovolemia, whereas fasted adrenalectomized rats become hypotensive and hypoglycemic after the first 90 min and die within 4 hours (h). We have studied the effects of glucose and corticosterone (B) infusions after hemorrhage as well as treatment with B at the time of adrenalectomy on the capacity of chronically prepared, conscious, fasted, adrenalectomized rats to survive hemorrhage. We have also measured the magnitudes of vasoactive hormone responses to hemorrhage. Maintenance of plasma glucose concentrations did not sustain life; however, treatment of rats at the time of adrenalectomy with B allowed 100 percent survival, and acute treatment of adrenalectomized rats at the time of hemorrhage allowed about 50 percent survival during the 5-h posthemorrhage observation period. Rats in the acute B infusion group that died exhibited significantly increased plasma B and significantly decreased plasma glucose concentrations by 2 h compared to the rats that lived. Plasma vasopressin, renin, and norepinephrine responses to hemorrhage were markedly augmented in the adrenalectomized rats not treated with B, and plasma vasopressin concentrations were significantly elevated at 1 and 2 h in all of the rats that subsequently died compared to values in those that lived. We conclude that: 1) death after hemorrhage in fasted adrenalectomized rats is not a result of lack of glucose; 2) chronic and, to an extent, acute treatment of fasted adrenalectomized rats with B enables survival; 3) fasted adrenalectomized rats exhibit strong evidence of hepatic insufficiency which is not apparent in either fed adrenalectomized rats or B-treated fasted adrenalectomized rats; 4) death after hemorrhage in fasted adrenalectomized rats may result from hepatic failure as a consequence of marked splanchnic vasoconstriction mediated bv the actions of extraordinarily high levels of vasoactive hormones after hemorrhage; and 5) B appears to act to decrease the magnitude of response of vasoactive hormones after hemorrhage in fasted adrenatectomized rats.

Darlington, Daniel N.↗

Sensors 2000! Program: Advanced Biosensor and Measurement Systems Technologies for Spaceflight Research and Concurrent, Earth-Based Applications

Sensors 2000! (S2K!) is a specialized, integrated projects team organized to provide focused, directed, advanced biosensor and bioinstrumentation systems technology support to NASA's spaceflight and ground-based research and development programs. Specific technology thrusts include telemetry-based sensor systems, chemical/ biological sensors, medical and physiological sensors, miniaturized instrumentation architectures, and data and signal processing systems. A concurrent objective is to promote the mutual use, application, and transition of developed technology by collaborating in academic-commercial-govemment leveraging, joint research, technology utilization and commercialization, and strategic partnering alliances. Sensors 2000! is organized around three primary program elements: Technology and Product Development, Technology infusion and Applications, and Collaborative Activities. Technology and Product Development involves development and demonstration of biosensor and biotelemetry systems for application to NASA Space Life Sciences Programs; production of fully certified spaceflight hardware and payload elements; and sensor/measurement systems development for NASA research and development activities. Technology Infusion and Applications provides technology and program agent support to identify available and applicable technologies from multiple sources for insertion into NASA's strategic enterprises and initiatives. Collaborative Activities involve leveraging of NASA technologies with those of other government agencies, academia, and industry to concurrently provide technology solutions and products of mutual benefit to participating members.

Hines, J.↗

New Millennium EO3

The New Millennium Program (NMP) is a NASA technology program that focuses on the validation of advanced spacecraft and instrumentation technologies in space. This program specifically seeks technologies that could significantly benefit future space and Earth science missions by enabling new science capabilities and reducing life cycle costs. These technologies must also require a validation in space to mitigate risks to the first science users, and provide cross-cutting benefits to both NASA's Earth and Space Science enterprises. The NASA Office of Earth Science (OES) directed the NMP to focus the third Earth Observing mission, E03, on innovative measurement concepts that would facilitate remote sensing observations from orbits beyond conventional low-Earth orbit (LEO). These orbits include geosynchronous orbits, highly elliptical orbits, mid-Earth and high-Earth orbits, and other unique vantage points such as L1 and L2. To maximize the input from the Earth science community, a NASA Research Announcement (NRA) was released to solicit innovative measurement concepts for this NMP flight. Because the NMP is a technology validation program, rather than a conventional science program, the NRA required that these measurement concepts employ revolutionary technologies and/or measurement strategies that will enable future science missions from orbits beyond LEO. Another requirement was that a validation in space was needed to reduce real or perceived risks of this concept to future science users. The proposals submitted in response to this NRA were peer reviewed by the NASA OES. The measurement concepts selected through this process will be summarized in this presentation. The E03 measurement concept NRA did not solicit complete mission concepts or flight hardware. Instead, the selected investigators will join integrated project formulation teams to define the mission for the demonstration of the measurement technique and participate in mission design trades and implementation planning. The teams will define and document the measurement approach, the required technologies, the validation plan, the scalability of the design to future science missions, and the infusion path for the completely validated instrument. During this project formulation phase, the specific technologies required to implement each measurement concept will be solicited through an open technology solicitation, and the technology providers will be added to the integrated teams. Once a complete candidate mission concept has been formulated for each measurement concept, these concepts will be subjected to a comprehensive review. The Associate Administrator of the OES will use the results of this review to select a single concept for the E03 flight opportunity. That mission concept will enter its implementation phase, which is expected to last for less than 36 months before launch. During this phase, and after launch, the implementation team will work with the NMP to document and disseminate the information gathered during the flight qualification testing and operations of the measurement concept and its component technologies. This information will be archived and published, where appropriate, to encourage the rapid infusion of these validated technologies into future space and Earth science missions. I

Li, Fuk K.↗

Advanced Concepts, Technologies and Flight Experiments for NASA's Earth Science Enterprise

Over the last 25 years, NASA Langley Research Center (LaRC) has established a tradition of excellence in scientific research and leading-edge system developments, which have contributed to improved scientific understanding of our Earth system. Specifically, LaRC advances knowledge of atmospheric processes to enable proactive climate prediction and, in that role, develops first-of-a-kind atmospheric sensing capabilities that permit a variety of new measurements to be made within a constrained enterprise budget. These advances are enabled by the timely development and infusion of new, state-of-the-art (SOA), active and passive instrument and sensor technologies. In addition, LaRC's center-of-excellence in structures and materials is being applied to the technological challenges of reducing measurement system size, mass, and cost through the development and use of space-durable materials; lightweight, multi-functional structures; and large deployable/inflatable structures. NASA Langley is engaged in advancing these technologies across the full range of readiness levels from concept, to components, to prototypes, to flight experiments, and on to actual science mission infusion. The purpose of this paper is to describe current activities and capabilities, recent achievements, and future plans of the integrated science, engineering, and technology team at Langley Research Center who are working to enable the future of NASA's Earth Science Enterprise.

Meredith, Barry D.↗

A Multi-Mission Testbed for Advanced Technologies

The mission of the Center for Space Integrated Microsystem (CSIM) at the Jet Propulsion Laboratory is to develop advanced avionics systems for future deep space missions. The Advanced Micro Spacecraft (AMS) task is building a multi-mission testbed facility to enable the infusion of CSIM technologies into future missions. The testbed facility will also perform experimentation for advanced avionics technologies and architectures to meet challenging power, performance, mass, volume, reliability, and fault tolerance of future missions. The testbed facility has two levels of testbeds: (1) a Proof-of-Concept (POC) Testbed and (2) an Engineering Model Testbed. The methodology of the testbed development and the process of technology infusion are presented in a separate paper in this conference. This paper focuses only on the design, implementation, and application of the POC testbed. Additional information is contained in the original extended abstract.

Chau, S. N.↗