Search NASA⌕ Search

SEARCH · Search NASA

Results for “instrument method optimization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Unsupervised Process Anomaly Detection and Identification Using the Leave-One-Variable-Out Approach

Automated anomaly detection and identification can signal equipment issues and pinpoint causes in large-scale industrial systems. For systems with limited failure history, unsupervised machine learning methods can be utilized as they do not require past failures. This study introduces the leave-one-variable-out (LOVO) model, which masks one variable at a time to predict the others, learning underlying process correlations. Detection performance was assessed with synthetic and experimental data, while identification performance used only synthetic data due to its ability to generate labeled anomaly types. For detection using synthetic data, the LOVO model generally outperformed comparative models; while using experimental data, the comparative methods outperformed the LOVO model. However, the comparative methods required selecting a latent size, and these conclusions pertain to using the optimal size. In practice, it would not be feasible to always select the optimal value, and incorrect selections impacted performance. In contrast, the LOVO model does not require a latent space. For identification using synthetic data, the LOVO model was slightly outperformed in interpretability and repeatability but still demonstrated impressive results. These outcomes suggest that the LOVO model is an effective model and may be more easily implemented without the challenging tuning process of selecting a latent size.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the design of an earth radiation budget instrument with system simulations. Part 2: Minimization of instantaneous sampling errors for CERES-I

Much of the new record of broadband earth radiation budget satellite measurements to be obtained during the late 1990s and early twenty-first century will come from the dual-radiometer Clouds and Earth's Radiant Energy System Instrument (CERES-I) flown aboard sun-synchronous polar orbiters. Simulation studies conducted in this work for an early afternoon satellite orbit indicate that spatial root-mean-square (rms) sampling errors of instantaneous CERES-I shortwave flux estimates will range from about 8.5 to 14.0 W/m on a 2.5 deg latitude and longitude grid resolution. Rms errors in longwave flux estimates are only about 20% as large and range from 1.5 to 3.5 W/sq m. These results are based on an optimal cross-track scanner design that includes 50% footprint overlap to eliminate gaps in the top-of-the-atmosphere coverage, and a 'smallest' footprint size to increase the ratio in the number of observations lying within to the number of observations lying on grid area boundaries. Total instantaneous measurement error also depends on the variability of anisotropic reflectance and emission patterns and on retrieval methods used to generate target area fluxes. Three retrieval procedures from both CERES-I scanners (cross-track and rotating azimuth plane) are used. (1) The baseline Earth Radiaton Budget Experiment (ERBE) procedure, which assumes that errors due to the use of mean angular dependence models (ADMs) in the radiance-to-flux inversion process nearly cancel when averaged over grid areas. (2) To estimate N, instantaneous ADMs are estimated from the multiangular, collocated observations of the two scanners. These observed models replace the mean models in computation of satellite flux estimates. (3) The scene flux approach, conducts separate target-area retrievals for each ERBE scene category and combines their results using area weighting by scene type. The ERBE retrieval performs best when the simulated radiance field departs from the ERBE mean models by less than 10%. For larger perturbations, both the scene flux and collocation methods produce less error than the ERBE retrieval. The scene flux technique is preferable, however, because it involves fewer restrictive assumptions.

Stowe, Larry↗

Miniature X-Ray Bone Densitometer

The purpose of the Dual Energy X-ray Absorptiometry (DEXA) project is to design, build, and test an advanced X-ray absorptiometry scanner capable of being used to monitor the deleterious effects of weightlessness on the human musculoskeletal system during prolonged spaceflight. The instrument is based on the principles of dual energy x-ray absorptiometry and is designed not only to measure bone, muscle, and fat masses but also to generate structural information about these tissues so that the effects on mechanical integrity may be assessed using biomechanical principles. A skeletal strength assessment could be particularly important for an astronaut embarking on a remote planet where the consequences of a fragility fracture may be catastrophic. The scanner will employ multiple projection images about the long axis of the scanned subject to provide geometric properties in three dimensions, suitable for a three-dimensional structural analysis of the scanned region. The instrument will employ advanced fabrication techniques to minimize volume and mass (100 kg current target with a long-term goal of 60 kg) of the scanner as appropriate for the space environment, while maintaining the required mechanical stability for high precision measurement. The unit will have the precision required to detect changes in bone mass and geometry as small as 1% and changes in muscle mass as small as 5%. As the system evolves, advanced electronic fabrication technologies such as chip-on-board and multichip modules will be combined with commercial (off-the-shelf) parts to produce a reliable, integrated system which not only minimizes size and weight, but, because of its simplicity, is also cost effective to build and maintain. Additionally, the system is being designed to minimize power consumption. Methods of heat dissipation and mechanical stowage (for the unit when not in use) are being optimized for the space environment.

Charles, Harry K., Jr.↗

The South Pole Telescope AGN Monitoring Campaign: First Release of SPTpol Bright AGN Light Curves

The South Pole Telescope (SPT) collaboration has recently embarked upon a campaign to monitor the brightness of a sample of active galactic nuclei (AGN), both in real time and in archival SPT data. The original design of the SPT was optimized for observations of the cosmic microwave background (CMB) at arc-minute and larger angular scales, and it has been used for this purpose for nearly twenty years, using three generations of CMB cameras. Recently it has been recognized that data from CMB experiments have the potential to be used for AGN monitoring. In this paper, we present the first public release of data from a full sample of SPT-monitored AGN, comprising 158 AGN light curves and associated data from the SPTpol camera, which was operational from 2012-2016. These light curves were created using observations from the SPTpol 500 deg$^{2}$ survey, in which the instrument was used to scan a 500 deg$^2$ patch of the sky several times per day with detectors sensitive to radiation in bands centered at 90 and 150 GHz. We provide a comprehensive description of the observations, the data processing methods, and the resulting light curve catalog. As an example of analyses that these data enable, we searched for a correlation between variability and spectral index, and we looked for ``bluer-when-brighter'' trends in the sample. Our analysis finds $> 10 σ$ correlation between fractional intrinsic variance and mean spectral index in the sample, but no significant evidence for bluer-when-brighter trends. The datasets from this study can be accessed through the SPT Treasury Record of AGN With Historical Activity and Time-Series or STRAWHAT catalog. This initial data release includes SPTpol light curves at 90 and 150 GHz, focusing on total intensity. In later updates, SPTpol polarization data and new observations from the SPT-3G instrument at 90, 150, and 220 GHz will be included.

Hood, J.C., II [Chicago U., KICP; Chicago U., Astr↗

Tracking Energy Flow Using a Volumetric Acoustic Intensity Imager (VAIM)

A new measurement device has been invented at the Naval Research Laboratory which images instantaneously the intensity vector throughout a three-dimensional volume nearly a meter on a side. The measurement device consists of a nearly transparent spherical array of 50 inexpensive microphones optimally positioned on an imaginary spherical surface of radius 0.2m. Front-end signal processing uses coherence analysis to produce multiple, phase-coherent holograms in the frequency domain each related to references located on suspect sound sources in an aircraft cabin. The analysis uses either SVD or Cholesky decomposition methods using ensemble averages of the cross-spectral density with the fixed references. The holograms are mathematically processed using spherical NAH (nearfield acoustical holography) to convert the measured pressure field into a vector intensity field in the volume of maximum radius 0.4 m centered on the sphere origin. The utility of this probe is evaluated in a detailed analysis of a recent in-flight experiment in cooperation with Boeing and NASA on NASA s Aries 757 aircraft. In this experiment the trim panels and insulation were removed over a section of the aircraft and the bare panels and windows were instrumented with accelerometers to use as references for the VAIM. Results show excellent success at locating and identifying the sources of interior noise in-flight in the frequency range of 0 to 1400 Hz. This work was supported by NASA and the Office of Naval Research.

Klos, Jacob↗

Automated Uas Measurements of Reflectance and Solar Induced Florescence (SIF) for Assessment Of the Dinamics in Photosynthetic Function, Application for Maze (Zea Mays L.) in Greenbelt, Maryland, Us

For accurate assessment of vegetation function there is a strong need for advancement in the remote sensing methods and instruments, to enable monitoring of the parameters governing photosynthesis at the temporal frequency relevant to their dynamics and at a spatial scale that allows practical assessment and management. Currently, no single sensor can provide data at the desired high temporal, spectral and spatial resolutions. Our field measurements obtained using the integrated UAS Piccolo system during the summers of2017 and 2018 demonstrate that science quality reflectance and solar induced fluorescence (SIF) data can be retrieved with high temporal frequency using small Unmanned Aerial Systems (UAS). The implemented approach facilitates data comparisons through space and time, and the integration with other spectral satellite and airborne data. This investigation contributes for bridging the gap in Earth observation between field and airborne measurements by implementing autonomous methods for obtaining high temporal frequency spectroscopy measurements from an Unmanned Aerial Systems (UAS) at various illumination conditions. An advancement in the Intelligent Payload Module (IPM) facilitated the implementation of an optimization workflow to collect spectral data for characterizing vegetation reflectance and solar induced fluorescence (SIF).

Petya Campbell↗

Spatially Resolving Ocean Color and Sediment Dispersion in River Plumes, Coastal Systems, and Continental Shelf Waters

Satellite remote sensing of ocean color in dynamic coastal, inland, and nearshorewaters is impeded by high variability in optical constituents, demands specialized atmospheric correction, and is limited by instrument sensitivity. To accurately detect dispersion of bio-optical properties, remote sensors require ample signal-to-noise ratio (SNR) to sense small variations in ocean color without saturating over bright pixels, an atmospheric correction that can accommodate significantwater-leaving radiance in the near infrared (NIR), and spatial and temporal resolution that coincides with the scales of variability in the environment. Several current and historic space-borne sensors have met these requirements with success in the open ocean, but are not optimized for highly red-reflective and heterogeneous waters such as those found near river outflows or in the presence of sediment resuspension. Here we apply analytical approaches for determining optimal spatial resolution, dominant spatial scales of variability ("patches"), and proportions of patch variability that can be resolved from four river plumes around the world between 2008 and 2011. An offshore region in the Sargasso Sea is analyzed for comparison. A method is presented for processing Moderate Resolution Imaging Spectroradiometer (MODIS) Aqua and Terra imagery including cloud detection, stray lightmasking, faulty detector avoidance, and dynamic aerosol correction using short-wave- and near-infrared wavebands in extremely turbid regions which pose distinct optical and technical challenges. Results showthat a pixel size of approx. 520 mor smaller is generally required to resolve spatial heterogeneity in ocean color and total suspended materials in river plumes. Optimal pixel size increases with distance from shore to approx. 630 m in nearshore regions, approx 750 m on the continental shelf, and approx. 1350 m in the open ocean. Greater than 90% of the optical variability within plume regions is resolvable with 500 m resolution, and small, but significant, differences were found between peak and nadir river flow periods in terms of optimal resolution and resolvable proportion of variability.

MODIS↗

Characterization of a Method for Inverse Heat Conduction Using Real and Simulated Thermocouple Data

It is often impractical to instrument the external surface of high-speed vehicles due to the aerothermodynamic heating. Temperatures can instead be measured internal to the structure using embedded thermocouples, and direct and inverse methods can then be used to estimate temperature and heat flux on the external surface. Two thermocouples embedded at different depths are required to solve direct and inverse problems, and filtering schemes are used to reduce noise in the measured data. Accuracy in the estimated surface temperature and heat flux is dependent on several factors. Factors include the thermocouple location through the thickness of a material, the sensitivity of the surface solution to the error in the specified location of the embedded thermocouples, and the sensitivity to the error in thermocouple data. The effect of these factors on solution accuracy is studied using the methodology discussed in the work of Pizzo, et. al.1 A numerical study is performed to determine if there is an optimal depth at which to embed one thermocouple through the thickness of a material assuming that a second thermocouple is installed on the back face. Solution accuracy will be discussed for a range of embedded thermocouple depths. Moreover, the sensitivity of the surface solution to (a) the error in the specified location of the embedded thermocouple and to (b) the error in the thermocouple data are quantified using numerical simulation, and the results are discussed.

Pizzo, Michelle E.↗

Robustness of Deep Learning Classification to Adversarial Input on GPUs: Asynchronous Parallel Accumulation Is a Source of Vulnerability

The ability of machine learning (ML) classification models to resist small, targeted input perturbations—known as adversarial attacks—is a key measure of their safety and reliability. We show that floating-point non associativity (FPNA) coupled with asynchronous parallel programming on GPUs is sufficient to result in misclassification, without any perturbation to the input. Additionally, we show that this misclassification is particularly significant for inputs close to the decision boundary and that standard adversarial robustness results may be overestimated up to 4.6 when not considering machine-level details. We first study a linear classifier, before focusing on standard Graph Neural Network (GNN) architectures and datasets used in robustness assessments. We develop a novel black-box attack using Bayesian optimization to discover external workloads that can change the instruction scheduling which bias the output of reductions on GPUs and reliably lead to misclassification. Motivated by these results, we present a new learnable permutation (LP) gradient-based approach to learning floating-point operation orderings that lead to misclassifications. The LP approach provides a worst-case estimate in a computationally efficient manner, avoiding the need to run identical experiments tens of thousands of times over a potentially large set of possible GPU states or architectures. Finally, using instrumentation-based testing, we investigate parallel reduction ordering across different GPU architectures under external background workloads, when utilizing multi-GPU virtualization, and when applying power capping. Our results demonstrate that parallel reduction ordering varies significantly across architectures under the first two conditions, substantially increasing the search space required to fully test the effects of this parallel scheduler-based vulnerability. These results and the methods developed here can help to include machine-level considerations into adversarial robustness assessments, which can make a difference in safety and mission critical applications.

Shanmugavelu, Sanjif [Maxeler Technologies, a Groq↗

Altimetry for the Future: Building on 25 Years of Progress

In 2018 we celebrated 25 years of development of radar altimetry, and the progress achieved by this methodology in the fields of global and coastal oceanography, hydrology, geodesy and cryospheric sciences. Many symbolic major events have celebrated these developments, e.g., in Venice, Italy, the 15th (2006) and 20th (2012) years of progress and more recently, in 2018, in Ponta Delgada, Portugal, 25 Years of Progress in Radar Altimetry. On this latter occasion it was decided to collect contributions of scientists, engineers and managers involved in the worldwide altimetry community to depict the state of altimetry and propose recommendations for the altimetry of the future. This paper summarizes contributions and recommendations that were collected and provides guidance for future mission design, research activities, and sustainable operational radar altimetry data exploitation. Recommendations provided are fundamental for optimizing further scientific and operational advances of oceanographic observations by altimetry, including requirements for spatial and temporal resolution of altimetric measurements, their accuracy and continuity. There are also new challenges and new openings mentioned in the paper that are particularly crucial for observations at higher latitudes, for coastal oceanography, for cryospheric studies and for hydrology. The paper starts with a general introduction followed by a section on Earth System Science including Ocean Dynamics, Sea Level, the Coastal Ocean, Hydrology, the Cryosphere and Polar Oceans and the ‘‘Green” Ocean, extending the frontier from biogeochemistry to marine ecology. Applications are described in a subsequent section, which covers Operational Oceanography, Weather, Hurricane Wave and Wind Forecasting, Climate projection. Instruments’ development and satellite missions’ evolutions are described in a fourth section. A fifth section covers the key observations that altimeters provide and their potential complements, from other Earth observation measurements to in situ data. Section 6 identifies the data and methods and provides some accuracy and resolution requirements for the wet tropospheric correction, the orbit and other geodetic requirements, the Mean Sea Surface, Geoid and Mean Dynamic Topography, Calibration and Validation, data accuracy, data access and handling (including the DUACS system). Section 7 brings a transversal view on scales, integration, artificial intelligence, and capacity building (education and training). Section 8 reviews the programmatic issues followed by a conclusion.

Saleh Abdalla↗

Batch VUV4 characterization for the SBC-LAr10 scintillating bubble chamber

The Scintillating Bubble Chamber (SBC) collaboration purchased 32 Hamamatsu VUV4 silicon photomultipliers (SiPMs) for use in SBC-LAr10, a bubble chamber containing 10 kg of liquid argon. A dark-count characterization technique, which avoids the use of a single-photon source, was used at two temperatures to measure the VUV4 SiPMs breakdown voltage (V BD ), the SiPM gain (g SiPM ), the rate of change of g SiPM with respect to voltage (m), the dark count rate (DCR), and the probability of a correlated avalanche (P CA ) as well as the temperature coefficients of these parameters. A Peltier-based chilled vacuum chamber was developed at Queen's University to cool down the Quads to 233.15 ± 0.2 K and 255.15 ± 0.2 K with average stability of ±20 mK. An analysis framework was developed to estimate V BD to tens of mV precision and DCR close to Poissonian error. The temperature dependence of V BD was found to be 56 ± 2 mV K -1 , and m on average across all Quads was found to be (459 ± 3(stat.)±23(sys.))× 10 3 e- PE -1 V -1 . The average DCR temperature coefficient was estimated to be 0.099 ± 0.008 K -1 corresponding to a reduction factor of 7 for every 20 K drop in temperature. The average temperature dependence of P CA was estimated to be 4000 ± 1000 ppm K -1 . P CA estimated from the average across all SiPMs is a better estimator than the P CA calculated from individual SiPMs, for all of the other parameters, the opposite is true. All the estimated parameters were measured to the precision required for SBC-LAr10, and the Quads will be used in conditions to optimize the signal-to-noise ratio.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluating the feasibility of using downwind methods to quantify point source oil and gas emissions using continuously monitoring fence-line sensors

The dependable reporting of methane (CH 4 ) emissions from point sources, such as fugitive leaks from oil and gas infrastructure, is important for profit maximization (retaining more hydrocarbons), evaluating climate impacts, assessing CH 4 fees for regulatory programs, and validating CH 4 intensity in differentiated gas programs. Currently, there are disagreements between emissions reported by different quantification techniques for the same sources. It has been suggested that downwind CH 4 quantification methods using CH 4 measurements on the fence line of production facilities could be used to generate emission estimates from oil and gas operations at the site level, but it is currently unclear how accurate the quantified emissions are. To investigate the accuracy of downwind methods, this study uses fence-line simulated data collected during controlled-release experiments as input for a non-standard closed-path eddy covariance (EC), the Gaussian plume inverse model (GPIM), and the backward Lagrangian stochastic (bLs) model in a range of atmospheric conditions. This study's EC attempt was unsuccessful due to data collection and instrumentation issues, resulting in invalid results characterized by underestimated emissions, large negative fluxes, and cospectra/ogives that deviated from their ideal shapes. Consequently, the EC results could not be compared with the GPIM and bLS model. The bLs model demonstrated the highest accuracy for single-release single-point emissions, though it exhibited greater uncertainty than GPIM under multi-release conditions. Across the GPIM and bLs model, the most reliable quantification was achieved with 15 min averaging and a narrow 5° wind sector range. Although EC was limited in this context, future studies should consider employing a standard EC system and further optimizing GPIM and bLs approaches – particularly for complex multi-source scenarios – to enhance quantification accuracy and reduce uncertainty.

03 NATURAL GAS↗

Active oversight and quality control in standard Bayesian optimization for autonomous experiments

The fusion of experimental automation and machine learning has catalyzed a new era in materials research, prominently featuring Gaussian Process (GP) Bayesian Optimization (BO) driven autonomous experiments. Here we introduce a Dual-GP approach that enhances traditional GPBO by adding a secondary surrogate model to dynamically constrain the experimental space based on real-time assessments of the raw experimental data. This Dual-GP approach enhances the optimization efficiency of traditional GPBO by isolating more promising space for BO sampling and more valuable experimental data for primary GP training. We also incorporate a flexible, human-in-the-loop intervention method in the Dual-GP workflow to adjust for unanticipated results. We demonstrate the effectiveness of the Dual-GP model with synthetic model data and implement this approach in autonomous pulsed laser deposition experimental data. This Dual-GP approach has broad applicability in diverse GPBO-driven experimental settings, providing a more adaptable and precise framework for refining autonomous experimentation for more efficient optimization.

36 MATERIALS SCIENCE↗

Best Practices for Measuring the Modulation Transfer Function of Video Endoscopes

Endoscopes are crucial for assisting in surgery and disease diagnosis, including the early detection of cancer. The effective use of endoscopes relies on their optical performance, which can be characterized with a series of metrics such as resolution, vital for revealing anatomical details. The modulation transfer function (MTF) is a key metric for evaluating endoscope resolution. However, the 2020 version of the ISO 8600-5 standard, while introducing an endoscope MTF measurement method, lacks empirical validation and excludes opto-electronic video endoscopes, the largest family of endoscopes. Measuring the MTF of video endoscopes requires tailored standards that address their unique characteristics. This paper aims to expand the scope of ISO 8600-5:2020 to include video endoscopes, by optimizing the MTF test method and addressing parameters affecting measurement accuracy. We studied the effects of intensity and uniformity of image luminance, chart modulation compensation, linearity of image digital values, auto gain control, image enhancement, image compression and the region of interest dimensions on images of slanted-edge test charts, and thus the MTF based on these images. By analyzing these effects, we provided recommendations for setting and controlling these factors to obtain accurate MTF curves. Our goal is to enhance the standard’s relevance and effectiveness for measuring the MTF of a broader range of endoscopic devices, with potential applications in the MTF measurement of other digital imaging devices.

47 OTHER INSTRUMENTATION↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system’s eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware.Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.Additionally, topics of what was learned and smaller tasks given at White Sands Test Facility (WSTF) will be discussed. All statements in this paper are newly gained knowledge of what I have learned, observed, and have done while at WSTF.

Ellis, Tayera↗

Multipurpose Pressure Vessel Scanner and Photon Doppler Velocimetry

Critical flight hardware typically undergoes a series of nondestructive evaluation methods to screen for defects before it is integrated into the flight system. Conventionally, pressure vessels have been inspected for flaws using a technique known as fluorescent dye penetrant, which is biased to inspector interpretation. An alternate method known as eddy current is automated and can detect small cracks better than dye penetrant. A new multipurpose pressure vessel scanner has been developed to perform internal and external eddy current scanning, laser profilometry, and thickness mapping on pressure vessels. Before this system can be implemented throughout industry, a probability of detection (POD) study needs to be performed to validate the system's eddy current crack/flaw capabilities. The POD sample set will consist of 6 flight-like metal pressure vessel liners with defects of known size. Preparation for the POD includes sample set fabrication, system operation, procedure development, and eddy current settings optimization. For this, collaborating with subject matter experts was required. This technical paper details the preparation activities leading up to the POD study currently scheduled for winter 2015/2016. Once validated, this system will be a proven innovation for increasing the safety and reliability of necessary flight hardware. Additionally, testing of frangible joint requires Photon Doppler Velocimetry (PDV) and Digital Image Correlation instrumentation. There is often noise associated with PDV data, which necessitates a frequency modulation (FM) signal-to-noise pre-test. Generally, FM radio works by varying the carrier frequency and mixing it with a fixed frequency source, creating a beat frequency which is represented by audio frequency that can be heard between about 20 to 20,000 Hz. Similarly, PDV reflects a shifted frequency (a phenomenon known as the Doppler Effect) from a moving source and mixes it with a fixed source frequency, which results in a beat frequency. However, for PDV, discerning the signal from the noise is difficult without a moving source to induce the modulation. A rotating wheel is currently being used as the moving source but its configuration is impractical and has cumbersome placement inside the current frangible joint test cell. As a way to combat this problem and verify a satisfactory signal-to-noise ratio, a reflective moving crystal piezo will be used to modulate a beat frequency, and an absorptive target will be used to block the signal in order to determine any back reflection coming from the probe and discern the true signal-to-noise ratio. The piezo will be mounted and inserted onto the test table on an extendable telescopic antenna grounded by a magnetic base in the test zone. This piezo configuration will be more compatible within the test zone and allow for easy removal of the disk following acceptable signal verification and prior to frangible joint tests.

Ellis, Tayera↗

Thermal Considerations for Reducing the Cooldown and Warmup Duration of the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in 2018, is NASAs next-generation flagship telescope. The Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) contain all of the optical surfaces and instruments to capture and analyze the telescopes infrared targets. The integrated OTE and ISIM are denoted as OTIS, and will be tested as a single unit in a critical thermal-vacuum test in mid-2017 at NASA Johnson Space Centers Chamber A facility. The payload will be evaluated for workmanship and functionality in a 20K simulated flight environment during this thermal-vacuum test. However, the sheer thermal mass of the OTIS payload as well as the restrictive gradient, rate, and contamination-related constraints placed on test components precludes rapid cooldown or warmup to its steady-state cryo-balance condition. Hardware safety considerations precludes injection of helium gas for free molecular heat transfer. Initial thermal analysis predicted that transient radiative cooldown from ambient temperatures, while meeting all limits and constraints, would take 33.3 days; warmup similarly would take 28.4 days. This paper discusses methods used to reduce transition times from the original predictions through modulation of boundary temperatures and environmental conditions. By optimizing helium shroud transition rates and heater usage, as well as rigorously re-examining previously imposed constraints, savings of up to three days on cooldown and up to a week on warmup can be achieved. The efficiencies gained through these methods allow the JWST thermal test team to create faster cooldown and warmup profiles, thus reducing the overall test duration and cost, while keeping all of the required test operations.

Thermal↗

Thermal Considerations for Reducing the Cooldown and Warmup Duration of the James Webb Space Telescope OTIS Cryo-Vacuum Test

The James Webb Space Telescope (JWST), set to launch in 2018, is NASAs next-generation flagship telescope. The Optical Telescope Element (OTE) and Integrated Science Instrument Module (ISIM) contain all of the optical surfaces and instruments to capture and analyze the telescopes infrared targets. The integrated OTE and ISIM are denoted as OTIS, and will be tested as a single unit in a critical thermal-vacuum test in mid-2017 at NASA Johnson Space Centers Chamber A facility. The payload will be evaluated for workmanship and functionality in a 20K simulated flight environment during this thermal-vacuum test. However, the sheer thermal mass of the OTIS payload as well as the restrictive gradient, rate, and contamination-related constraints placed on test components precludes rapid cooldown or warmup to its steady-state cryo-balance condition. Hardware safety considerations precludes injection of helium gas for free molecular heat transfer. Initial thermal analysis predicted that transient radiative cooldown from ambient temperatures, while meeting all limits and constraints, would take 33.3 days; warmup similarly would take 28.4 days. This paper discusses methods used to reduce transition times from the original predictions through modulation of boundary temperatures and environmental conditions. By optimizing helium shroud transition rates and heater usage, as well as rigorously re-examining previously imposed constraints, savings of up to three days on cooldown and up to a week on warmup can be achieved. The efficiencies gained through these methods allow the JWST thermal test team to create faster cooldown and warmup profiles, thus reducing the overall test duration and cost, while keeping all of the required test operations.

JWST↗