Search NASA⌕ Search

SEARCH · Search NASA

Results for “instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Fungi↗

In-flight performance of the XRISM/Resolve detector system

The Resolve instrument was launched on board the XRISM observatory in early September 2023. The Resolve spectrometer is based on a high-sensitivity X-ray calorimeter detector system (DS) that has been successfully deployed in many ground and sub-orbital spectrometers. However, the Resolve instrument is the first long-term implementation in space. The instrument will provide essential diagnostics for nearly every class of X-ray emitting objects, from galactic supernova remnants to the outskirts of galaxy clusters, without degradation for spatially extended objects. The Resolve DS consists of a 36-pixel microcalorimeter array operated at a heat sink temperature of 50 mK. In pre-flight testing, the DS demonstrated a resolving power of better than 1300 at 6 keV with a simultaneous bandpass from below 0.3 keV to above 12 keV and a timing precision better than 100μs. An anti-coincidence detector placed directly behind the microcalorimeter array effectively suppresses background. The detector energy-resolution budget included terms for interference from the Resolve cooling system and the spacecraft. Additional terms for energy-scale stability, on-orbit effects, and use of mid-grade events were also included, predicting an end-of-life, on-orbit performance for high- and mid-resolution grade events that meet the requirement of 7 eV FWHM at 6 keV. Here, we discuss the actual on-orbit performance of the Resolve DS and compare this with the performance in pre-flight testing, on-orbit predictions, and the almost identical Hitomi/SXS instrument. We will also discuss the on-orbit gain stability, an assessment of on-orbit interference, and measurements of the on-orbit background.

Astronomy and AstroPhysics↗

Data for Clumping Index Estimation With 30°-tilted Cameras in Row Crops: Evaluation of Methods and Segment Size Effects

The clumping index (CI) quantifies the spatial distribution of foliage elements and is essential for accurately estimating the plant area index (PAI), canopy radiative transfer, and photosynthesis. Traditionally, the finite-length averaging method (LX), the gap size distribution method (CC), and a combined approach of CC and LX (CLX) have been applied to instruments like TRAC and digital hemispherical photography to estimate CI. However, a comprehensive evaluation of these methods in row crops remains limited, especially regarding the influence of segment size on CI. Meanwhile, digital cameras offer a cost-effective and user-friendly solution for canopy measurements in row crops, yet their application in this context remains underexplored. In this study, we employed a new approach using a 30°-tilted digital camera to estimate CI in corn and soybean fields, applying the LX, CC, and CLX methods. We systematically assessed the performance of these three methods by combining field measurements in real-world fields with simulations using the LESS 3D radiative transfer model. Our results showed that CLX applied to the whole image and 45° segment offered accurate estimation of CI (bias within ±0.1, RMSE < 0.2) and PAI (bias within ±0.4, RMSE < 1) in real-world fields and LESS simulations. The accuracy of the LX method was highly sensitive to segment size, with the best performance observed at the 15° segment (PAI bias within ±0.4). In contrast, the CC method remained stable across different segment sizes, and its performance was generally comparable to that of LX, except at the 15° segment. Across view zenith angles, CI derived from CC generally showed a continuous increase, while those from LX and CLX followed a rising trend at small zenith angles but began to decline at 68°, likely due to an increasing proportion of no-gap segments. Seasonally, LX tended to show decreasing CI during early growth stages but increased as the canopy matured, whereas CC and CLX showed gradually increasing CI before plateauing at peak PAI. The 30°-tilted camera effectively captured CI variations across different angles and growth stages, making it a practical and robust instrument for row crop canopy structure analysis. Applying these CI methods to digital cameras offers a low-cost and accessible CI estimation alternative, improving canopy structure monitoring accuracy in row crops.

Modeling↗

Terrestrial laser scanning data (Levels 0 and 1) from Urban Biogeochemistry Pilot Project sites, Knoxville, Tennessee, Jul 2024 - Jul 2025

This data package contains data from terrestrial laser scanning (TLS) at five urban park sites in Knoxville, Tennessee, USA. All parks include open-grown and/or closed-canopy trees and mixed nearby land use. These study sites were established as part of the Urban Biogeochemistry Pilot Project, which has an overall goal of better understanding how hydrobiogeochemical cycling is altered within the human environment. These five sites represent a gradient of urbanization, and were instrumented to understand hydrological and biogeochemical cycling (e.g., soil moisture, soil physical properties and biogeochemistry, tree transpiration, species type). The TLS data archived here were collected to provide detailed, three-dimensional information about forest structure. Specifically, data were collected to allow tree- and stand-level characterization of woody structure and leaf area. TLS scans were placed to capture the area around trees with sap flow sensors, and as much of a 50 m radius area around the meteorological station as possible given site property limits. Derived products will allow upscaling of water content and transpiration data. This data package contains the following data: - High-level files document further details of the campaign and data package: 1_CampaignSummary.csv provides details about the campaign and study site, 2_ScanAreasDetail.csv provides details about each separate scan area (groups of scans post-processed into a single point cloud), 3_TerrestrialLidarSensor.csv provides further technical details about the Riegl VZ-400i TLS sensor, TLS_CSV_dd.csv is a CSV Data Dictionary providing information about the fields in CSV files following the ESS-DIVE CSV File Formatting Guidelines Reporting Format, TLS_flmd.csv is a File Level Metadata file providing information about each file in the data package following the ESS-DIVE File Level Metadata Reporting Format, and README.txt is a text file describing the overall project and file structure. - Level 0 data are the raw data (.PROJ folders) as recorded by the Riegl VZ-400i TLS instrument before scan co-registration and post-processing with the Riegl's proprietary RiSCAN PRO software, which requires a license. - Level 1 data contain post-processed, co-registered data from each scan area. The "PointClouds" folder for each scan area contains a .las file with 1 cm resolution point cloud data exported from RiSCAN PRO. These are the main files likely to be of interest to most users and can be further processed with any software capable of manipulating .las files (e.g. Python, R CloudCompare). The "Project Information" folder contains log files from post-processing in RiSCAN PRO that may be of interest to users who want to see detailed records of post-processing, including all PDF reports generated by RiSCAN PRO. The "ScanPositions" folder contains information about the final position of all TLS scans, after post-processing, in multiple formats. The file ScanPositions_*.csv provides final geo-referenced scan positions, and the file SOP_backup_*.csv can be used in RiSCAN PRO to restore the co-registered scan positions if users wish to re-process raw data (Level 0 .PROJ folders) with RiSCAN PRO software (e.g., subsample to a different resolution, exclude a certain scan position, or apply different filters on reflectance or deviation values) without redoing time-consuming co-registration steps.

54 ENVIRONMENTAL SCIENCES↗

Zero Resistance Ammetry (ZRA) Measurements of Sediment Electrochemical Gradients, Old Woman Creek, Ohio, USA, June–November 2022

This dataset contains raw and processed zero resistance ammetry (ZRA) measurements collected from wetland sediments at Old Woman Creek, a freshwater estuary on Lake Erie, Ohio, USA, between June and November 2022. Measurements were obtained using a vertically deployed electrode array positioned at multiple depths within the sediment profile to capture electrochemical gradients associated with microbial activity and sediment geochemistry. The raw dataset consists of parsed instrument log files containing timestamps, electrode pair identifiers, and measured electrical potential (mV). The processed dataset includes standardized and quality-controlled values with instrument saturation limits removed and timestamps converted to ISO 8601 format. Electrode line identifiers were mapped to physical depths, enabling interpretation of depth-resolved electrochemical gradients. Instrument saturation values (−2048, −2047, 2047, and 2048 mV) were identified as measurement limits and excluded from quantitative analyses. All data parsing, processing, and quality control steps are documented in an accompanying R Markdown script, ensuring full reproducibility from raw instrument logs to final datasets.

EARTH SCIENCE > AGRICULTURE > SOILS > ELECTRICAL C↗

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7 Li (CRADA 626) Final Report

The intent of this project was to determine appropriate methodologies for analysis of lithium isotopes for 1) quasi-online monitoring of isotope separations, and 2) high-precision characterization of end-products, including lithium fluoride and lithium-beryllium fluoride (FLiBe). Traditionally, isotopic analysis requires the use of expensive, sophisticated instrumentation with often relatively long analytical timelines. We determined that the use of cheaper, smaller, and easier-to-operate instruments are sufficient for rapid analysis of lithium isotopes to monitor isotope separation efficiencies. In addition, we found that the analytical precision afforded by these lower-cost instruments is comparable to the more sophisticated (i.e., more expensive) instrumentation when the isotopic composition of lithium becomes highly depleted in 6Li. This finding will ultimately help lower costs of manufacturing of depleted lithium that is required for operation of certain designs of Generation IV nuclear reactors.

07 ISOTOPE AND RADIATION SOURCES↗

Merged Aerosol Value-Added Product Report

The Merged Aerosol Value-Added Product (VAP) simplifies scientists’ use of Atmospheric Radiation Measurement (ARM) User Facility aerosol data by performing several tedious, time-consuming tasks for the users. First, the VAP identifies the best data available when multiple datastreams exist for a single geophysical quantity so that ARM users do not have to research this for themselves. Second, the VAP consolidates multiple ARM aerosol datastreams into a single file for ARM data users so that they do not have to download, open, and read multiple files for their analysis. Next, the VAP transforms all measurements onto a common one-hour timestamp. The one-hour resolution matches the time resolution of the slowest instrument. Instruments with faster sampling rates than one measurement per hour are averaged over the time interval. Finally, the VAP reads the QA/QC variables and marks data with known issues as missing, so that users do not have to spend excessive time cleaning data. This includes incorporating Data Quality Reports (DQRs) that exist at the time when the VAP data is generated. DQRs are reports filed by instrument mentors or data users that indicate a problem with the output data of individual instruments.

54 ENVIRONMENTAL SCIENCES↗

RHOD Site - NOAA PSL Wind Retrievals WINDoe / Derived Data

This dataset contains daily NetCDF files with horizontal wind profiles retrieved with the WINDoe retrieval (Gebauer and Bell 2024) at Rhode Island (RHOD). WINDoe retrievals datasets are also available at Nantucket Island (NANT, nant.windoe.z01.c1) and Block Island (BLOC, bloc.windoe.z01.c1). WINDoe is an optimal estimation algorithm to retrieve wind profiles combining multiple instruments. The code is available in this github repository (https://github.com/OAR-atmospheric-observations/WINDoe/tree/main) and the retrieval is described by Gebauer and Bell (2024). WINDoe allows combining the individual datasets and outputs into one profile taking into account the information and uncertainties of each dataset. The use of WINDoe minimizes data gaps and maximizes data availability, compared to using wind profiles from only one of the instruments. The regular height grid eases comparisons to numerical weather prediction models. Code modifications have been made that include reading in WFIP3 specific instruments, averaging Doppler lidar radial velocities at various azimuth angles to avoid overfitting, and allowing the user to define a height grid by the user in the vipfile. The instruments used as input to the retrieval are a radar wind profiler (low- and high resolution mode) providing data in and above the boundary layer, a scanning Doppler lidar usually providing data throughout the boundary layer, a profiling lidar providing data from 50 to 200 m at BLOC and NANT, and from 10 to 280 m at Rhode Island, and a surface tower (4 m at NANT and RHOD and 10 m at BLOC). From the scanning lidars, we used radial velocity measurements at 60 deg elevation angle at six different azimuth angles with a resolution of approximately 30 m along the line of sight and the lowest range gate at approximately 70 m. The wind profiles are retrieved with WINDoe up to 3.74 km with 10 m vertical resolution. The profiles are retrieved every 15 min at BLOC and NANT and every 60 min at RHOD.

17 WIND ENERGY↗

BLOC Site - NOAA PSL Wind Retrievals WINDoe / Derived Data

This dataset contains daily netcdf files with horizontal wind profiles retrieved with the WINDoe retrieval (Gebauer and Bell 2024) at Block Island (BLOC). WINDoe retrievals datasets are also available at Nantucket Island (NANT, nant.windoe.z01.c1) and Rhode Island (RHOD, rhod.windoe.z01.c1). WINDoe is an optimal estimation algorithm to retrieve wind profiles combining multiple instruments. The code is available in this github repository (https://github.com/OAR-atmospheric-observations/WINDoe/tree/main), and the retrieval is described by Gebauer and Bell (2024). WINDoe allows combining the individual datasets and outputs into one profile taking into account the information and uncertainties of each dataset. The use of WINDoe minimizes data gaps and maximizes data availability, compared to using wind profiles from only one of the instruments. The regular height grid eases comparisons to numerical weather prediction models. Code modifications have been made that include reading in WFIP3 specific instruments, averaging Doppler lidar radial velocities at various azimuth angles to avoid overfitting, and allowing the user to define a height grid by the user in the vipfile. The instruments used as input to the retrieval are a radar wind profiler (low- and high resolution mode) providing data in and above the boundary layer, a scanning Doppler lidar usually providing data throughout the boundary layer, a profiling lidar providing data from 50 to 200 m at BLOC and NANT, and from 10 to 280 m at Rhode Island, and a surface tower (4 m at NANT and RHOD and 10 m at BLOC). From the scanning lidars, we used radial velocity measurements at 60 deg elevation angle at six different azimuth angles with a resolution of approximately 30 m along the line of sight and the lowest range gate at approximately 70 m. The wind profiles are retrieved with WINDoe up to 3.74 km with 10 m vertical resolution. The profiles are retrieved every 15 min at BLOC and NANT and every 60 min at RHOD.

17 WIND ENERGY↗

NANT Site - NOAA PSL Wind Retrievals WINDoe / Derived Data

This dataset contains daily NetCDF files with horizontal wind profiles retrieved with the WINDoe retrieval (Gebauer and Bell 2024) at Nantucket Island (NANT). WINDoe retrievals datasets are also available at Block Island (BLOC, bloc.windoe.z01.c1) and Rhode Island (RHOD, rhod.windoe.z01.c1). WINDoe is an optimal estimation algorithm to retrieve wind profiles combining multiple instruments. The code is available in this github repository (https://github.com/OAR-atmospheric-observations/WINDoe/tree/main), and the retrieval is described by Gebauer and Bell (2024). WINDoe allows combining the individual datasets and outputs into one profile taking into account the information and uncertainties of each dataset. The use of WINDoe minimizes data gaps and maximizes data availability, compared to using wind profiles from only one of the instruments. The regular height grid eases comparisons to numerical weather prediction models. Code modifications have been made that include reading in WFIP3 specific instruments, averaging Doppler lidar radial velocities at various azimuth angles to avoid overfitting, and allowing the user to define a height grid by the user in the vipfile. The instruments used as input to the retrieval are a radar wind profiler (low- and high resolution mode) providing data in and above the boundary layer, a scanning Doppler lidar usually providing data throughout the boundary layer, a profiling lidar providing data from 50 to 200 m at BLOC and NANT, and from 10 to 280 m at Rhode Island, and a surface tower (4 m at NANT and RHOD and 10 m at BLOC). From the scanning lidars, we used radial velocity measurements at 60 deg elevation angle at six different azimuth angles with a resolution of approximately 30 m along the line of sight and the lowest range gate at approximately 70 m. The wind profiles are retrieved with WINDoe up to 3.74 km with 10 m vertical resolution. The profiles are retrieved every 15 min at BLOC and NANT and every 60 min at RHOD.

17 WIND ENERGY↗

Evaluation of the hyperspectral radiometer (HSR1) at the Atmospheric Radiation Measurement (ARM) Southern Great Plains (SGP) site

Abstract. The Peak Design Ltd hyperspectral radiometer (HSR1) was tested at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) site in Lamont, Oklahoma, for 2 months from May to July 2022. The HSR1 is a prototype instrument that measures total (Ftotal) and diffuse (Fdiffuse) spectral irradiance from 360 to 1100 nm with a spectral resolution of 3 nm. The HSR1 spectral irradiance measurements are compared to nearby collocated spectral radiometers, including two multifilter rotating shadowband radiometers (MFRSRs) and the Shortwave Array Spectroradiometer–Hemispheric (SASHe) radiometer. The Ftotal at 500 nm for the HSR1 compared to the MFRSRs has a mean (relative) difference of 0.01 W m−2 nm−1 (1 %–2 %). The HSR1 mean Fdiffuse at 500 nm is smaller than the MFRSRs' by 0.03–0.04 (10 %) W m−2 nm−1. The HSR1 clear-sky aerosol optical depth (AOD) is also retrieved by considering Langley regressions and compared to collocated instruments such as the Cimel sunphotometer (CSPHOT), MFRSRs, and SASHe. The mean HSR1 AOD at 500 nm is larger than the CSPHOT's by 0.010 (8 %) and larger than the MFRSRs' by 0.007–0.017 (6 %–18 %). In general, good agreement between the HSR1 and other instruments is found in terms of the Ftotal, Fdiffuse, and AODs at 500 nm. The HSR1 quantities are also compared at other wavelengths to the collocated instruments. The comparisons are within ∼ 10 % for the Ftotal and Fdiffuse, except for 940 nm, where there is relatively larger disagreement. The AOD comparisons are within ∼ 10 % at 415 and 440 nm; however, a relatively larger disagreement in the AOD comparison is found for higher wavelengths.

54 ENVIRONMENTAL SCIENCES↗

TBS FROST Data from 2023 at SGP C1

The FROST provides chemical analysis of four time-resolved sorbent samples on a LECO GCxGC Bench Time of Flight Mass Spectrometer, using a Gerstel MPS Thermal Desorption System. Samples collected via FROST can be analyzed on one of two Sandia National Laboratories' instruments. One instrument will provide ultra-high mass spectrometer resolution (up to four decimal points or m/z data) and can be used for identification of true unknowns. Data can include suspected formulas of species not included in any current mass spectra database. This instrument also has a low limit of detection of known species (tens of femtogram range). The second instrument can provide an order of magnitude lower limits of detection (into the single-digit femtogram range) for known species currently in mass spectra databases. This system is also more resilient to environmental samples that contain higher levels of moisture.

54 ENVIRONMENTAL SCIENCES↗

Size resolved particle volatility for 30, 60, and 90 nm particles collected at the EPCAPE Mount Soledad site from 04/23/2023 to 06/15/2023

VTDMA GF-PDF: Growth factor probability density functions from the Gysel inversion are located here, where probability is out of 200. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904. GF_Vol_avg: Growth factor volume average calculated by the Gysel inversion. The instrument measured three different diameters 30 nm, 60nm and 90nm each diameter was selected for an hour. During that hour three different temperatures where scanned (40°C, 80°C, 160°C) in between each temperature a bypass scan was taken at room temperature. Each scan took 10-minutes and scanned growth factors from 0.2-1.2. Calibrations of the instrument with NaCl were performed on 4/26/2023 from 11:20 to 14:20, on 5/16/2023 from 11:40 to 16:00, and on 5/30/2023 from 10:20 to 14:20. Calibrations with (NH4)2SO4 were performed on 5/8/2023 from 11:45 to 14:40, on 5/23/2023 from 11:20 to 3:00, and on 6/14/2023 from 13:00 to 16:00. Time is recorded in seconds since 1/1/1904.

30nm growth factor volume average at 160C (GF_vol_↗

Design of a Loss of Coolant Blowdown Capsule for Remote Assembly with High Burnup Fuel

The Transient Water Irradiation System is an enhanced capability capsule type irradiation vehicle designed to support fuel safety research for light water reactor specimens in the Transient Reactor Test Facility and is designed to simulate loss of coolant and reactivity-initiated accidents. The capsule was designed, deployed, and commissioned with fresh fuel specimens to validate instrumentation and prepare for previously irradiated high burnup specimens. The irradiation system features an extensive in-situ instrumentation package to detect phenomena typical to light water reactor fuels. To accommodate the assembly with high burnup specimens inside the Hot Fuel Examination Facility, and to ensure instrumentation integrity is maintained throughout assembly, the design was updated to support remote handling. The updated design features a hinge mechanism which allows for remote pre-irradiated specimen loading and assembly while protecting sensitive instrumentation by relocating during loading. Fixtures and equipment have been developed to handle the experiment capsule and components in cell, and to support remote assembly. The experiment module also includes radiation shielding and contamination control to support operations after removal from the hot cell.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods

Supports with integrated sensors for nuclear reactor steam generators, and associated systems and methods, are disclosed. A representative method for forming a nuclear-powered steam generator includes forming an instrumented support, the instrumented support including a carrier portion and a retainer portion, with at least one of the carrier portion or the retainer portion being integrally formed with a sensor via an additive manufacturing process. The method can further include coupling the sensor to a communication link, supporting a helical steam conduit on the instrumented support, and installing the helical steam conduit and the instrumented support in a nuclear reactor. The helical steam conduit is positioned along a primary flow path, which is in turn positioned to circulate a heated primary flow in thermal communication with the helical steam conduit.

Welter, Kent↗

10 Boron-film-based gas detectors at ESS

The development of detectors for the European Spallation Source is an important parallel element to the effort put into the design and construction of the neutron source and instruments. The 10Boron-film-based detector developments that started over a decade ago as basic detector concepts have now reached technical maturity after intense prototyping work and numerous testing campaigns. Several of the ESS beamlines that will soon enter the commissioning phase started welcoming the detector systems built with the 10 B-film converter technology. The real-size demonstrators evolved in the last 2–3 years into a diverse suite of gas proportional counters for use in diffraction, reflectometry and small-angle scattering studies in spite of the operational complexity posed by the requirements for large-area coverage, low material budget and robustness for operation in the high-flux and high-radiation environment of ESS. The detectors are now being shipped to ESS or undergoing the last performance and calibration tests before being handed over to the instrument teams for installation in the host beamlines. A common feature of these detector systems is the very large number of readout channels that they are instrumented with in order to fulfill the demanding requirements for sensitivity, spatial resolution and count-rate capability. Across all of the detector types that will operate at ESS, the integration, testing and commissioning of the read-out technologies and software tools for data reduction, calibration and analysis are the focus of the detector and integration teams. These will yield a wealth of knowledge about their operation as well as initial results on the in-situ performance, a very important asset to ensure rapid commissioning of the detectors when neutrons from the ESS source become available. In this paper we will give an overview of the 10 B-film-based detector technologies included in the ESS detector suite that are currently facing the transition from the production phase to installation and integration with the other beamline components, which comes with its own specific challenges of both organizational and technical nature.

47 OTHER INSTRUMENTATION↗

The Psyche Gamma-Ray and Neutron Spectrometer

A Gamma-Ray and Neutron Spectrometer (GRNS) instrument has been developed as part of the science payload for NASA’s Discovery Program Psyche mission to the M-class asteroid (16) Psyche. The GRNS instrument is designed to measure the elemental composition of Psyche with the goal to understand the origin of this mysterious, potentially metal-rich planetary body. The GRNS will measure the near-surface abundances for the elements Ni, Fe, Si, K, S, Al, and Ca, as well as the spatial distribution of Psyche’s metal-to-silicate fraction (or metal fraction). These measurements address three of the five Psyche mission science objectives: determine if Psyche is a core; determine whether small metal bodies incorporate light elements into the metal phase; and determine whether Psyche was formed under reducing conditions. The Gamma-Ray Spectrometer (GRS) uses a cryocooled, high-purity Ge (HPGe) sensor to detect cosmic-ray generated gamma rays in the 60 to 9000-keV energy range. The HPGe sensor is surrounded by a borated plastic anticoincidence shield that provides three functions: active background rejection from charged particle interactions in the HPGe sensor; fast neutron measurements; and direct measurements of the incident galactic cosmic ray flux. The Neutron Spectrometer (NS) uses three 3 He gas proportional sensors, each with different material wraps to measure thermal (<0.4 eV), low-energy epithermal (0.4 eV to 1 keV), and high-energy epithermal (up to 100 keV) neutrons. This paper provides an overview of the Psyche GRNS, including: its science and measurement objectives; the design of the instrument hardware, software, and operation; pre-launch performance measurements and its initial performance in space; and an overview of its data products and expected operation for different Psyche mission phases.

Engineering - Instrumentation related to nuclear s↗