Pathway to Decarbonization Through Industrial Energy Efficiency: Micro and Macro Perspectives from Compressed Air Usage

Abstract Energy audits directly provided the industrial sector with reduced energy costs and avoided emissions. Still, they also lead to far-reaching indirect and induced local, regional, and national benefits. This paper aims to present the techno-economic-environmental analysis to achieve decarbonization through implementing industrial energy efficiency at micro and macro levels. An integrated techno-economic-environmental methodology is developed. Case studies of micro-level carbon reduction efforts through industrial energy efficiency technologies are presented. The broader macroeconomic and environmental effects of technology on society are analyzed using data from 206 energy audits of industrial compressed air systems conducted over 13 years. The impacts show that energy-efficient improvements lead to direct cost savings for manufacturers, boost economic activity across sectors, and affect carbon dioxide emissions both short-term and long-term in the region. Given their extensive benefits, energy audits significantly influence policymaking. We devised a methodology to link micro-level energy audit data with macroeconomic and environmental analyses to quantify these cascading benefits. The economic scenario analysis shows that $228 M has been saved from direct industrial energy savings from implementing all compressed air recommendations in the studied periods and the region. In addition, the investment made through manufacturers would create 2,025 jobs and $383 M annually, cascading regional economic impacts. The environmental analysis shows that the regional manufacturers have directly avoided about 2.8 M metric tons of carbon dioxide emissions.

Engineering↗

Pathways for Agricultural Decarbonization in the United States

In the United States, agricultural production is both a significant source of greenhouse gases (GHGs) (Environmental Protection Agency (EPA), 2022) and uniquely susceptible to climate change impacts (Vermeulen et al., 2012). Decarbonization solutions have been proposed for addressing agricultural GHGs; however, research has been limited in synthesizing qualitative and quantitative analysis of potential GHG mitigation solutions in the United States. In this report, we review U.S. agricultural GHG sources by activity and quantify potential mitigation solutions based on a comprehensive data and literature analysis. We also discuss agricultural carbon sequestration options to offset GHG emissions. In our analysis, we identified two significant and hard-to-abate GHG sources (N 2 O from soil management, and CH 4 from enteric fermentation from livestock) as well as high-impact GHG mitigation solutions (e.g. agroforestry, reforestation, and biochar application) and cross-cutting GHG mitigation solutions (renewable energy production, precision agriculture, no-till, integrated nutrient management, and biochar). This report is meant to provide initial analysis and establish a foundation for future agricultural decarbonization research - it is not an exhaustive analysis of all available studies. However, to our knowledge this report is the most comprehensive assessment of agricultural GHG emissions and associated mitigation opportunities in the United States to date. Future empirical research is recommended to close research gaps in different climates, soils, and agricultural systems. Meta-analyses for all mitigation solutions would increase confidence in the estimated GHG mitigation potentials. To conclude this report, we discuss short-term and long-term pathways for agricultural decarbonization in the United States, the importance of accounting for total GHG fluxes, potential co-benefits of agricultural decarbonization, analysis of study data confidence, and research gaps.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

System Analysis Modeling and Intermodal Transportation for Commercial Spent Nuclear Fuel

The United States Department of Energy (DOE) has long term goals to develop solutions for managing the nation’s spent nuclear fuel (SNF) and high-level waste (HLW) inventory. The Integrated Waste Management (IWM) program under the DOE office of Nuclear Energy (DOE-NE) is employing system-level engineering and analysis principles to inform potential future waste management system architectures. Managing the spent nuclear waste requires the use of system-level analysis software that takes various aspects of the fuel cycle into account like waste generation, on-site/centralized storage, transportation infrastructure, and long-term disposal. The Next Generation System Analysis Model (NGSAM) is an agent-based model that was developed to simulate the transportation and storage of SNF and HLW. As an agent-based model, NGSAM has the capability to detail the interaction and movement of individual components and groups, such as rail cars and casks. The SNF inventory from commercial nuclear reactors is currently in temporary storage at multiple locations spread across the United States. Shipping of SNF from these locations relies on one of three transportation modes: rail, heavy-haul truck, or barge. Out of the three modes identified, rail is generally the most preferred due to the size of the canisters and casks the SNF would be shipped in. However, under some scenarios, a direct rail route might not be readily available to a reactor site or improving the rail infrastructure at shutdown sites might be too cost-prohibitive for utilities to opt for a direct rail transfer. Under such scenarios, using a barge or heavy haul truck to de-inventory the site and transfer the SNF to a nearby intermodal transfer site with adequate rail infrastructure where the payload could be transferred to a rail car might prove to be an attractive option. This work initially presents the various intermodal transportation options that could be used to transfer SNF from reactor sites to rail cars. This is followed by exploring the operational steps in each of these modes to move the SNF from a reactor site and transfer it to a rail car. This work also presents the procedure of implementing the intermodal transfer methodology in NGSAM using various Java methods. Finally, the process times for accomplishing each of the individual steps are furnished. The implementation ideology, assumptions, and future steps are presented in this work.

Gadey, Harish Reddy↗

Amplitude analysis and branching fraction measurement of the decay $D_s^{+}$ → $π^+π^0π^0$

Using a data set corresponding to an integrated luminosity of 6.32 fb –1 recorded by the BESIII detector at center-of-mass energies between 4.178 and 4.226 GeV, an amplitude analysis of the decay $D_s^{+}$ → $π^+π^0π^0$ is performed, and the relative fractions and phases of different intermediate processes are determined. The absolute branching fraction of the decay $D_s^{+}$ → $π^+π^0π^0$ is measured to be (0.50 ± 0.04 stat ± 0.02 syst )%. The absolute branching fraction of the intermediate process $D_s^{+}$ → $f_o$(980)$π^+$, $f_o$(980) → $π^oπ^o$ is determined to be (0.28 ± 0.04 stat ± 0.04 syst )%.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Adapting the Technology Performance Level Integrated Assessment Framework to Low-TRL Technologies Within the Carbon Capture, Utilization, and Storage Industry, Part I

With the urgent need to mitigate climate change and rising global temperatures, technological solutions that reduce atmospheric CO 2 are an increasingly important part of the global solution. As a result, the nascent carbon capture, utilization, and storage (CCUS) industry is rapidly growing with a plethora of new technologies in many different sectors. There is a need to holistically evaluate these new technologies in a standardized and consistent manner to determine which technologies will be the most successful and competitive in the global marketplace to achieve decarbonization targets. Life cycle assessment (LCA) and techno-economic assessment (TEA) have been employed as rigorous methodologies for quantitatively measuring a technology's environmental impacts and techno-economic performance, respectively. However, these metrics evaluate a technology's performance in only three dimensions and do not directly incorporate stakeholder needs and values. In addition, technology developers frequently encounter trade-offs during design that increase one metric at the expense of the other. The technology performance level (TPL) combined indicator provides a comprehensive and holistic assessment of an emerging technology's potential, which is described by its techno-economic performance, environmental impacts, social impacts, safety considerations, market/deployability opportunities, use integration impacts, and general risks. TPL incorporates TEA and LCA outputs and quantifies the trade-offs between them directly using stakeholder feedback and requirements. In this article, the TPL methodology is being adapted from the marine energy domain to the CCUS domain. Adapted metrics and definitions, a stakeholder analysis, and a detailed foundation-based application of the systems engineering approach to CCUS are presented. The TPL assessment framework is couched within the internationally standardized LCA framework to improve technical rigor and acceptance. It is demonstrated how stakeholder needs and values can be directly incorporated, how LCA and TEA metrics can be balanced, and how other dimensions (listed earlier) can be integrated into a single metric that measures a technology's potential.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Techno-Economic Optimization of CSP Plants with Free-Falling Particle Receivers

Particle receivers are one of the candidates for the next generation of CSP plants, whose goal is to reduce the levelized cost of electricity (LCOE) to 0.05 $/kWh. This paper presents a techno-economic analysis to study if a CSP system with free-falling particle receiver can achieve this goal. The plant analyzed integrates two ground-based bins to store the excess energy and a supercritical CO2 cycle to generate electricity. The model used for the analysis presents several upgrades to previous particle systems models in order to increase its fidelity, accuracy, and representativeness of an actual system. The main upgrades are the addition of off-design conditions during the annual simulations in all the components and an improved receiver model validated against CFD simulations. The size of the main components is optimized to obtain the system configuration with minimum LCOE. The results show that particle CSP systems can reduce the LCOE to 0.056 $/kWh if the configuration is composed of 1.61 × 106 m2 of heliostats, a 250 m high tower with a 537 m2 falling particle curtain, and 16 h thermal energy storage.

54 ENVIRONMENTAL SCIENCES↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Inertia Estimation and Trend Analysis of the United States Power Grid Interconnections

The transition from conventional to modern power systems is causing an increase in integration of inverter-based resources (IBRs). This generally leads to a decrease in total system inertia, which in-turn increases the system’s rate-of-change-of-frequency (RoCoF) during disturbances. This poses a threat to the frequency stability of the system and may falsely trigger protective devices. To monitor system status and plan for integrating renewable energy sources like photovoltaic, wind, and energy storage systems, a realistic study of inertia estimation and analysis in the United States (US) over the past decade is needed. This paper uses field-measured phasor measurement unit (PMU) data collected throughout the US from 2013 to 2023 via the Frequency Monitoring Network (FNET/GridEye) operated by the University of Tennessee, Knoxville (UTK) and Oak Ridge National Laboratory (ORNL). The collected PMU frequency data is utilized to estimate the system inertia of the three US interconnections: Eastern, Western, and Texas. Various RoCoF time windows are investigated for estimating the inertia of each interconnection by maximizing the correlation coefficient between the measured RoCoF and power mismatch. The resulting inertia trends over the past decade show approximately a 6% decline in inertia in the Eastern interconnection, a 15% decline in inertia in the Western interconnection, and a 16% increase in inertia in Texas. Key insights into how inertia is changing amidst the complex energy landscape are extracted using the fuel mix trend data. This provides valuable information for future energy strategies and planning.

30 DIRECT ENERGY CONVERSION↗

Renewable Energy Technologies and Integrated Energy Systems

As renewable energy deployment expands, its integration into broader energy systems becomes an opportunity for providing clean energy across multiple sectors. This presentation will review statistics about the growth of renewable energy and potential future trends, with an additional focus technologies important to Colorado. It will also present options for integration with other low emissions technologies, such as nuclear energy and storage, and how together they could create an integrated energy system for multiple sectors. The presentation will also include an introduction to the mission and research of the National Renewable Energy Laboratory (NREL) and the Joint Institute for Strategic Energy Analysis (JISEA).

ENERGY PLANNING, POLICY, AND ECONOMY,ENVIRONMENTAL↗

Measurements of electroweak production of a photon in association with two jets in proton-proton collisions at $\sqrt{s}=13$ TeV

The first observation of electroweak production of a photon in association with two forward jets in proton-proton collisions is presented. The measurement uses data recorded by the CMS experiment at the LHC during 2016–2018 at a center-of-mass energy of 13 TeV, corresponding to an integrated luminosity of 138 fb −1 . The analysis is performed in a region enriched in photon production via vector boson fusion, with a requirement on the transverse momentum of the photon to exceed 200 GeV. The cross section is measured to be ${202}_{-32}^{+36}$ fb, at a significance with respect to the null hypothesis that exceeds five standard deviations. This is in agreement with the standard model prediction of ${177}_{-12}^{+13}$ fb. Differential cross sections are measured as a function of various observables. Limits are set on dimension-6 effective field theory operators that contribute to the WW γ interaction. The observed 95% confidence intervals for the corresponding Warsaw basis Wilson coefficients c W and c HWB are [−0.11, 0.16] and [−1.6, 1.5], respectively.

electroweak interaction↗

Measurement of the top quark pair production cross section in PbPb collisions at $\sqrt{s_{\mathrm{NN}}}=5.36$ TeV

The inclusive cross section for top quark pair ($\mathrm{t}\overline{\mathrm{t}}$) production in lead-lead (PbPb) collisions is reported for the first time at a center-of-mass energy per nucleon pair of 5.36 TeV. The analysis uses data corresponding to an integrated luminosity of 1.58 nb −1 collected by the CMS experiment at the CERN LHC in 2023. The $\mathrm{t}\overline{\mathrm{t}}$ production cross section, ${\sigma}_{\mathrm{t}\overline{\mathrm{t}}}={3.42}_{-0.51}^{+0.54}{\left(\mathrm{stat}\right)}_{-0.43}^{+0.50}\left(\mathrm{syst}\right)$ μb, is measured in dilepton final states using a fit to a multivariate discriminator that combines the decay electron and muon kinematic properties with the multiplicity of bottom quark jets. The result is consistent with perturbative quantum chromodynamics calculations at next-to-next-to-leading order (NNLO) accuracy employing several nuclear parton distribution functions. In addition, the Drell–Yan production cross section (σ DY ) for dilepton masses above 10 GeV and the ratio of $\mathrm{t}\overline{\mathrm{t}}$ to DY cross sections $\left({R}_{\mathrm{t}\overline{\mathrm{t}}/\mathrm{DY}}\right)$ are found to be compatible with the NNLO predictions. The observables ${\sigma}_{\mathrm{t}\overline{\mathrm{t}}}$, σ DY , and ${R}_{\mathrm{t}\overline{\mathrm{t}}/\mathrm{DY}}$ are measured separately for central and semicentral PbPb collisions to investigate for the first time the dependence of top quark production on the collision impact parameter.

Heavy Ion Experiments↗

City Climate Action Plans Through the Lens of The Food-Energy-Water Nexus

Interdependent resource management concepts originated in the mid-20th century, and the recent use of the term “nexus” highlights interconnected relationships among resources like food, energy, and water. United States and European science foundations have shown a growing interest in the food-energy-water (FEW) nexus, leading to increased research on their joint management. However, one major criticism of the FEW nexus is the limited translation of the research into practical policies and implementation, such as climate action plans. To assess the incorporation of FEW nexus principles into climate planning, we systematically evaluate 100 climate action plans from large U.S. cities. Our findings show that the most discussed FEW links involve energy, particularly the water-for-energy and food-for-energy connections, found in over half of the documents (56%). Our analysis promotes the integration of the FEW nexus into climate action plans while addressing the barriers to its effective implementation.

Mounir, Adil [Air Force Institute of Technology]↗

Demonstrate Capability of NEAMS Tools to Generate Reactor Kinetics Parameters for Pebble-Bed HTGRs Transient Modeling

The system analysis of anticipated operating occurrences and design basis accident for pebblebed reactor systems requires knowledge of the neutron kinetic parameters. These parameters take into account various types of feedback from the pebble-bed core and are typically integrated into system analysis tools such as the System Analysis Module (SAM) in the Nuclear Energy Advanced Modeling and Simulation (NEAMS) tool package. These parameters are typically generated by a higher fidelity full-core coupled neutronics/thermal fluids analysis, such as using Griffin and Pronghorn, in 2D or 3D. The delayed neutron fractions (beta) and the neutron lifetimes (lambda) are typically generated by applying the adjoint solution of the neutron flux. Temperature reactivity coefficients are the most important feedback for all anticipated operating occurrences and design basis accident, then depending on the transient other effects might be important as rector control system worth, s-curves, and Xenon generation. This work package will establish a methodology and process for calculating the reactor kinetics parameters for high-temperature gas-cooled reactor and provide them in a suitable form for system level analyses of typical anticipated operating occurrences and design basis accident.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Ammonium Looping with Membrane Absorber and Distributed Stripper for Enhanced Algae Growth

The objective of this project is to conduct a comprehensive investigation to develop and demonstrate a practical, reliable, and cost-effective integrated carbon dioxide (CO 2 ) capture and biofixation process for algae production. This process utilizes a chemical hindered ammonium solution (NH 4 OH) as both a capture reagent and an algae nutrient. The membrane absorber employed in the system ensured minimal ammonia (NH 3 ) emissions in the treated flue gas. Additionally, distributed solar-energy powered strippers located near the bioreactor modules facilitate solvent regeneration and enable just-in-time delivery of CO 2 and NH 3 to the algae, thereby minimizing the pH swing for enhanced productivity. The proposed membrane CO 2 absorber and solar-powered stripper is designed and seamlessly integrated with the existing 0.1 MWth bench-scale CO 2 capture system (CCS) and open raceway ponds (ORPs) at the University of Kentucky Center for Applied Energy (UK CAER) campus. The entire integrated process has undergone construction, operation, testing, and analysis. Furthermore, technology has been evaluated with a techno-economic analysis (TEA), technology gap analysis (TGA), life-cycle analysis (LCA), and a technology maturation plan (TMP). This project was performed within two budget periods, 54 months in duration. There are fourteen Project Tasks, twelve Milestones and four Success Criteria.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Stochastic Optimization and Uncertainty Quantification of Natrium-based Nuclear-Renewable Energy Systems for Flexible Power Applications in Deregulated Markets

Rapid integration of variable renewable energy sources (VRES) has made modeling and stochastic optimization of hybrid energy systems crucial for studying their long-term performance and viability. However, most studies have focused on just historical data, which may be unreliable for capturing short-term fluctuations, rare events, and long-term patterns of energy demand, price, and the variability of renewable energy sources. For this study, optimal synthetic time series models were developed using Wasserstein distance. The models were validated by comparing the key statistical measures against those of the historical data. They were then used to optimize the integrated Natrium-style advanced energy systems and their long-term (30 years) economics. The stochastic model performs bi-level optimization to find the optimal sizes for the balance of plant and thermal energy storage, while also optimizing energy dispatch to achieve the maximum net present value. In studies of two deregulated markets (California ISO and the Electric Reliability Council of Texas), the integrated Natrium-style system performed better in CAISO than in ERCOT, given higher and more consistent electricity prices during peak-demand periods. The potentially enlarged cost associated with the variable operation and maintenance of the TES system also plays a significant role in driving the system sizing, thus its impacts on the system are investigated in detail through comparison against a baseline case. The study also finds that the bi-level optimization results based on stochastic gradient descent closely match the grid search results. The uncertainty quantification of the stochastic signals provides further NPV-related insights and probability distributions for the case studies. The normal standard error of the mean of NPV for the case with and without TES VOM for CAISO were found to be 7.73M (plus-minus sign) 1.09M USD and 104.99M (plus-minus sign) 1.25M USD, respectively based on a 95% confidence. Given the relatively small NPV variance based on 150 samples, the analysis affords the most robust possible prediction of the techno-economic performance of the integrated Natrium-style energy systems.

25 ENERGY STORAGE↗

FORCE-DISPATCHES Integration - Initial Demonstration

Integrated energy systems (IES) combine, in mutually beneficial ways, power from variable renewable energy sources and nuclear power plants (NPP) to improve economic viability under uncertain market and weather conditions. The open-source Framework for Optimization of Resources and Economics (FORCE) tool suite, developed at Idaho National Laboratory (INL), has enabled comprehensive modeling and simulation of IES. The capabilities within FORCE include grid portfolio optimization through the Holistic Energy Resource Optimization Network (HERON) and the transient process model analysis library HYBRID, among others. Continuous efforts and investments from the IES programs have been made to expand and improve the versatility of the FORCE toolset in fiscal year 2022. Code-coupling and cross-tool communication have been important methods for improving this versatility. This report focuses on an additional workflow in the HERON tool for capacity and dispatch stochastic optimization through integration with the external tool Design Integration and Synthesis Platform to Advance Tightly Coupled Hybrid Energy Systems (DISPATCHES). DISPATCHES was primarily developed by the National Energy Technology Laboratory, in collaboration with other national laboratories, which included INL, universities, and industry partners. It is coupled to a library of algebraic models for specific plant components, and to a framework for stochastic optimization different from that provided in the current Risk Analysis Virtual Environment (RAVEN)-running-RAVEN algorithm in HERON. HERON currently conducts stochastic optimization via an outer-inner loop: it optimizes over variable capacity on the outer loop, and at each step within the capacity parameter space, conducts an inner optimization over scenarios (of market signals, demand, and/or weather patterns) and hourly dispatch throughout a user-specified number of years. On the other hand, DISPATCHES conducts stochastic optimization via an “all-at-once” strategy in which capacity variables are optimized at the same level as dispatch variables, as all scenarios are considered at once. The latter method works especially well for projects of limited size and project length, as the necessary computational power and memory increases with the number of variables and scenarios. The new capability to use the DISPATCHES workflow in HERON enhances standalone simulations by leveraging FORCE tools—namely, the economic metrics from the Tool for Economic Analysis (TEAL) and reduced-order model (ROM) sampling from RAVEN. The initial demonstration of the DISPATCHES workflow simulates an existing nuclear-case flowsheet within the DISPATCHES repository—this models a NPP with a secondary revenue stream for hydrogen production. Electrical output from the plant is converted to hydrogen via a proton-exchange membrane (PEM) electrolyzer, hydrogen tanks are used for storage, and an additional turbine is added for hydrogen combustion. Continued work regarding this FORCE-DISPATCHES integration will include automatic generation of DISPATCHES models from HERON inputs, offering analysts the option of using either the RAVEN-runsRAVEN or DISPATCHES workflow to solve technoeconomic optimization problems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Multi-Fidelity Model and Co-Simulation Platform for Distribution System Transient and Dynamic Analysis—DistribuDyn

As inverter-based, distributed energy resources (DERs) and variable loads continue to proliferate across distribution systems, it is increasingly important to understand their impacts on system stability and reliability. However, most commercially available simulation tools for distribution planning primarily focus on steady-state and quasi-steady state analysis, offering limited capabilities to study transient and dynamic behaviors.

24 POWER TRANSMISSION AND DISTRIBUTION↗