Search NASASearch

SEARCH · Search NASA

Results for “integrated energy system”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

1,950 records · Page 16

Security Constrained Economic Optimization of Photovoltaic and Other Distributed Assets

The rapid growth of distributed energy resources (DERs), especially photovoltaic (PV) systems, has introduced new complexities in maintaining grid reliability, stability, and cost-effective operation. This project addresses these challenges by developing and demonstrating a scalable GridOS Distributed Energy Resource Management System (DERMS) that enables secure, real-time optimization and control of DERs at the distribution feeder level.

14 SOLAR ENERGY

Testing and Validation of Wireless Communication Architecture for Heliostat Fields: SIPS Final Report

This work focuses on the development and testing of a low-cost wireless communication system for heliostat fields, enabling significant capital costs reductions for concentrating solar thermal systems. Outputs of this work include a working demonstration of a multi-node communication system, clear reporting of system performance, and technical documentation of system development and architecture for reproducibility. Through this process, an open-source repository was created for manufacturing hardware at ~$30/heliostat. The system includes software for cybersecurity, achieving sub-second communication latencies and derisking of hardware for eventual scale-up to tens of thousands of heliostats. While the system is not currently off-the-shelf ready, there is now a clearly defined pathway for scaling up and completing the commercial development process.

14 SOLAR ENERGY

The In-Orbit Battery Reconditioning Experience On Board the Orion 1 Spacecraft

The Orion 1 spacecraft is a three-axis stabilized geostationary earth orbiting commercial communications satellite which was launched on November 29, 1994 aboard an Atlas II launch vehicle. The power subsystem is a dual bus, dual battery semi-regulated system with one 78 Ampere-hour nickel-hydrogen battery per bus. The batteries were built and tested by Eagle Picher Industries, Inc., of Joplin, MO and were integrated into the spacecraft by its manufacturer, Matra Marconi Space UK Ltd. This paper presents the results obtained during the first four in-orbit reconditioning cycles and compares the battery performance to ground test data. In addition, the on-station battery management strategy and implementation constraints are described. Battery performance has been nominal throughout each reconditioning cycle and subsequent eclipse season.

Hoover, S. A.

Ares I-X Ground Diagnostic Prototype

The automation of pre-launch diagnostics for launch vehicles offers three potential benefits: improving safety, reducing cost, and reducing launch delays. The Ares I-X Ground Diagnostic Prototype demonstrated anomaly detection, fault detection, fault isolation, and diagnostics for the Ares I-X first-stage Thrust Vector Control and for the associated ground hydraulics while the vehicle was in the Vehicle Assembly Building at Kennedy Space Center (KSC) and while it was on the launch pad. The prototype combines three existing tools. The first tool, TEAMS (Testability Engineering and Maintenance System), is a model-based tool from Qualtech Systems Inc. for fault isolation and diagnostics. The second tool, SHINE (Spacecraft Health Inference Engine), is a rule-based expert system that was developed at the NASA Jet Propulsion Laboratory. We developed SHINE rules for fault detection and mode identification, and used the outputs of SHINE as inputs to TEAMS. The third tool, IMS (Inductive Monitoring System), is an anomaly detection tool that was developed at NASA Ames Research Center. The three tools were integrated and deployed to KSC, where they were interfaced with live data. This paper describes how the prototype performed during the period of time before the launch, including accuracy and computer resource usage. The paper concludes with some of the lessons that we learned from the experience of developing and deploying the prototype.

Machine Learning

SR-1 Freedom Thermal Architecture Challenges

The SR-1 Freedom mission aims to demonstrate nuclear electric propulsion (NEP) and deliver the Skyfall helicopter payload to Mars. Repurposing the existing Gateway Power and Propulsion Element (PPE) spacecraft and combining it with a 20 kWe-class nuclear power module (NPM) presents a variety of thermal architecture challenges. These include unprecedented waste heat rejection requirements, integration with a spacecraft bus originally designed for a different mission profile, and novel packaging constraints. This presentation will describe the simplified concept of operations as it relates to on-orbit thermal environments, early-phase architecture trades and supporting analyses, and planned forward work. We will also discuss our strategy for integrated thermal modeling of the complete spacecraft and examples of interface challenges necessitated by this ambitious effort.

Thermal

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Future Aerospace Technology in the Service of the Alliance: Sustained Hypersonic Flight - Volume 3

Sustained Hypersonic Flight capability is envisioned for several future military and civilian applications, such as long range immediate reaction reconnaissance, high speed interception of air targets, long range precision strike against hardened or time critical targets, and access to space. The inherent reduction in time-to-target and low vulnerability will permit new operational tactics. The symposium outlined mission needs and operational scenarios for hypersonic vehicles. Addressed were: Technological issues and challenges in external hypersonic aerodynamics and design, propulsion and engine/airframe integration, military ramjet applications, overall system design including structures and materials development needs, and test facilities. Ground based test facilities cannot provide full simulation at Mach numbers above 5. Therefore, the use of Computational Fluid Dynamics design tools is essential. For routine use of the computational tools in analysis, design and optimization, it is necessary to reduce the time for the entire computational process by two orders of magnitude. Hypersonic boundary layer transition remains a critical design issue because of the important impact on engine drag and on heating, which can affect the choice of materials and thermal protection systems. In addition, reliable prediction of scramjet net thrust is an absolute must in resolving hypersonic air breathing vehicle design issues. Due to current facility and computational shortfalls, the development of future hypersonic flight systems requires research flight tests in the technology areas of boundary layer transition and air-breathing propulsion engine performance. For sustained hypersonic flight beyond Mach 6, the supersonic combustion ramjet (scramjet) engine is the only choice for the near future. Only this air-breathing concept offers a significant promise of large reductions in required propellant fractions, increased payload fractions, and reduced size vehicles, together with a foreseeable technological feasibility. Airframe/engine integration, combustor design and thermal management are the predominant engineering tasks. Fuels, hydrogen or hydrocarbon, must be matched to the operational needs of military or civil use. Experience in existing ramjet propelled missiles capable of speeds up to Mach 4 can support the development effort. The potential mission and cost benefits of sustained hypersonic flight to both military and civil applications are tremendous. From the budget point of view, the possibility of sharing development costs between military and civil programs offers a specific advantage.

Combustion chambers

Intrinsically Conductive {pi}‑d Conjugated Layers with Co–N4 Active Sites for Efficient Nitrate Electrocatalysis and Zinc-Nitrate Batteries

Electrochemical synthesis of ammonia from nitrate has been extensively investigated as a potential alternative to the energy-intensive Haber-Bosch process. This approach not only operates under ambient conditions but also simultaneously removes nitrate contaminants while producing ammonia as a value-added product. However, the ongoing quest lies in designing an efficient electrocatalyst that achieves a high ammonia yield rate, high selectivity, and long-term stability. Herein, we report the outstanding performance of a Co–N4 coordinated π-d layered Co3(HITP)2 (HITP = 2,3,6,7,10,11-hexaiminotriphenylene) in nitrate electrocatalysis. The unique combination of abundant Co–N4 active sites and superior electrical conductivity enables significant electrocatalytic activity, delivering a maximum ammonia yield rate of 56.8 mg cm–2 h–1 at −0.8 V vs RHE and a Faradaic efficiency of ∼91% at −0.4 V vs RHE. Mechanistic analysis reveals that alkaline conditions accelerate water dissociation to generate adsorbed hydrogen intermediates (H*), which are utilized by Co–N4 sites to drive the stepwise hydrogenation of nitrate to ammonia while suppressing competing hydrogen evolution reaction (HER) pathways. Furthermore, integration of this catalyst into a zinc-nitrate battery resulted in a maximum power density of 5.3 mW cm–2 and an open-circuit potential of ∼1.45 V. These results highlight the potential of π-d conjugated Co–N4 materials as an efficient catalyst for both environmental remediation and energy conversion.

Namvar, shahrirar

Roadmap and Benchmarking: Privacy in Federated Load Forecasting

Data-driven techniques for energy demand forecasting continue to emerge with promising impacts on distribution grid planning. However, the development of robust and generalizable machine learning models requires that representative high quality training data are available. Distributed energy resources have begun to embed intelligence, gathering large amounts of data on customer demand, behavior, and household devices that are connected to the grid. Though utilities aggregate meter-level demand data for load shaping, demand response, outage management, reliability planning, and billing applications, there lies an inherent privacy concern in sharing consumption data that may identify individual consumer behavioral patterns. Hence, while sharing the data is crucial, the private sensitive customer data must be safeguarded from being exposed or manipulated. In this study, we propose a roadmap for implementing a based privacy preserving framework to support the advancement of data-driven analytics in data-sensitive distributed energy resources environments. The roadmap incorporates federated learning–a distributed training framework, differential privacy–a statistical framework that provides guarantees to safeguard the leakage of sensitive data, secure multiparty computation and homomorphic encryption– techniques for encrypting model gradients and applying secure aggregation on the server. Moreover, we perform baseline experiments on the federated short-term load forecasting (STLF) task using open-source residential load profile datasets, offering insights into the challenges of integrating differential privacy into federated learning.

Abebe, Waqwoya [Oak Ridge National Laboratory (ORN

From Exploration Flight Test-1 to Artemis II--A NASA Langley's Orion Aerosciences Overview

The Orion Aerosciences program at NASA Langley has played a central role in advancing the aerodynamic and aeroheating prediction capabilities required for the Orion crew vehicle’s return from deep space. This presentation provides a technical overview of aerosciences contributions spanning Exploration Flight Test-1 (EFT-1), Artemis I, and the ongoing post-flight analysis of Artemis II. EFT-1 provided the first high-energy entry dataset for Orion, enabling critical validation of aerodynamic force and moment predictions, static and dynamic stability characteristics, and aeroheating environments at relevant flight Mach and Reynolds numbers. Flight-derived pressure data were used to refine the Flush Air Data System (FADS) methodology for atmospheric density reconstruction and to improve Best Estimated Trajectory (BET) solutions. The EFT-1 data also offered key insights into heat shield performance, including char layer recession, in-depth thermal response, and material retention behavior under flight conditions, informing updates to both thermal response models and uncertainty quantification practices. Building on EFT-1, Artemis I extended the database to true lunar-return conditions. Observations of heat shield performance, including localized char loss, bondline response, and recession variability, provided an unprecedented opportunity to reassess Thermal Protection System (TPS) and aeroheating modeling assumptions. Aerodynamic reconstruction efforts incorporated improved FADS calibration, enhanced atmospheric modeling, and refined force and moment databases to reduce trajectory and load uncertainties. Aeroheating comparisons between pre-flight predictions and flight data enabled targeted model updates, particularly in transitional flow environments and wake heating regions. For Artemis II, these lessons were systematically incorporated into the pre-flight prediction process. Updates included refined aerodynamic databases anchored to flight-validated corrections, improved density estimation and BET methodologies using enhanced database interpolation algorithm and FADS modeling, and revised aeroheating design environments informed by Artemis I material response observations. By the time of the workshop, Artemis II post-flight analysis will be underway, and preliminary findings will be presented where available, including early comparisons of aerodynamic reconstruction, atmospheric density estimation, and thermal protection system performance relative to updated predictions. Collectively, this body of work is a testament to the dedicated and multidisciplinary team whose sustained efforts have contributed to the program’s success and to the progressive maturation of Orion aerosciences modeling through numerical modeling, ground and flight data assimilation. The integrated advancement of aerodynamics, trajectory reconstruction, FADS-based density estimation, and aeroheating analysis has reduced predictive uncertainty and strengthened confidence for future crewed lunar and deep-space missions.

Orion

R&D GREET Battery Carbon Footprint Calculator

The Battery Carbon Footprint (CF) Calculator was developed to help U.S. battery manufacturers meet the carbon footprint reporting requirements of the EU Battery Regulation (EU) 2023/1542. The calculator incorporates several major battery carbon footprint frameworks, including the Joint Research Centre's Rules for the Calculation of the Carbon Footprint of Electric Vehicle Batteries (CFB-EV), RECHARGE's Product Environmental Footprint Category Rules for High Specific Energy Rechargeable Batteries for Mobile Applications (PEFCR), the Catena-X Product Carbon Footprint Rulebook (CX-PCF Rules), Battery Pass's Battery Carbon Footprint: Rules for Calculating the Carbon Footprint of the "Distribution" and "End-of-Life and Recycling" Life Cycle Stages, the Global Battery Alliance's Greenhouse Gas Rulebook: Generic Rules, Version 2.1, and the Ministry of Economy, Trade and Industry's draft Carbon Footprint Calculation Method for Automotive Batteries. The tool pairs these frameworks with foreground data from Argonne's R&D GREET models and integrates user-supplied background data covering battery manufacturing and supply chain activities. By bringing multiple international methodologies together in a single platform, the calculator enables manufacturers to evaluate product carbon footprints, improve data consistency, and prepare for evolving regulatory compliance and global market reporting requirements.

Zhang, Jingyi

Initial Jitter Analysis of Lynx, a Proposed Future Large Astrophysics Facility

Lynx is an X-Ray telescope large-mission concept for consideration in NASA's 2020 Astrophysics Decadal Survey. A conceptual structural design is evolving that leverages the success and lessons learned from Chandra and that takes into account unique needs of Lynx. Space optics systems require extreme stability. Any motion in-service (thermal effects, structural dynamics, etc.) impacts performance. An initial analysis was performed to predict the first-cut dynamic responses, jitter, at two selected points on the Lynx observatory. One point is on the Lynx X-ray Mirror Assembly (LMA) and the other, on the focal plane Integrated Science Instrument Module (ISIM). Relative motion between these two points was predicted along with vibration spectra. This information will be used in upcoming analyses of the LMA and the ISIM.

J Brent Knight

Dronebase Photovoltaic (PV) Fleet Imagery Quantitative Evaluation (CRADA CRD-22-22941 Final Report)

Combine the Dronebase aerial imagery with corresponding sites in the NLR Photovoltaic (PV) Fleets database. By combining these two data sources in an aggregated, anonymized fashion, we can perform the following analyses: quantifying power loss due to outages caused by stuck trackers, string outages, and shading/snow, validate site metadata, including tilt and azimuth, and correlate.

14 SOLAR ENERGY

Combustion for future supersonic transport propulsion

Even with it's marginal performance, Concorde has demonstrated that supersonic civil aircraft are a practical proposition. A second generation machine will need sufficiently good performance for a robust operating system that can provide reliable, frequent service with competitive economics. Additionally, the propulsion system must be acceptable environmentally. That is it must create acceptable noise levels around airports and have acceptable emissions throughout its mission including cruise. Whatever devices may be used to improve the acceptability at subsonic flight conditions, the high operating temperatures at cruise can create difficult targets for the operation of the combustion system both mechanically and in the combustion process itself. While the driving force is ever better fuel consumption and weight to achieve economic viability, a future supersonic transport engine will have cycle temperatures limited only by the mechanical integrity of the major components. The environment of the major components in modern gas turbine engines is dominated by the air delivered by the compressor system. Consequently the maximum compression temperature is governed by materials available for the turbine and compressor discs. The continued improvement of the disc material leads to combustion inlet temperatures beyond today's experience and sets difficult targets for combustion system emissions. This is worsened by the requirement being at cruise and therefore maintained for the major part of the mission. Problems such as creep and oxidation of metallic parts are also considered.

B. W. Lowrie

Thermal stability of 3D interface Cu/Nb nanolaminates

Nanocrystalline alloys are promising structural materials yet lack thermal stability in many cases. Recent work shows that interface structure has an outsize effect on the thermal behavior of nanostructured alloys. Here, this work focuses on the role of controlled heterophase interface structure in the thermal evolution of model Cu/Nb nanolaminates. We introduce 3D interfaces containing nanoscale heterogeneities in all spatial dimensions between Cu and Nb, forming 3D Cu/Nb. TEM, nanoindentation, and DSC are used in tandem to establish thermal stability and to identify shifts in microstructure as a function of static annealing temperature. 3D interfaces are shown to survive annealing to 300 °C for 1 hr., while 3D Cu/Nb microstructure evolves to form low-density and voided regions correlating to the onset of layer pinch-off between 500 and 600 °C annealing temperatures. A diffusivity- and vacancy energetics-based mechanism is developed to explain void formation driven by 3D interface degradation at elevated temperature.

3D interfaces

Mariner Mars 1971 battery design, test, and flight performance

The design, integration, fabrication, test results, and flight performance of the battery system for the Mariner Mars spacecraft launched in May 1971 are presented. The battery consists of 26 20-Ah hermetically sealed nickel-cadmium cells housed in a machined magnesium chassis. The battery package weighs 29.5 kg and is unique in that the chassis also serves as part of the spacecraft structure. Active thermal control is accomplished by louvers mounted to the battery baseplate. Battery charge is accomplished by C/10 and C/30 constant current chargers. The switch from the high-rate to low-rate charge is automatic, based on terminal voltage. Additional control is possible by ground command or onboard computer. The performance data from the flight battery is compared to the data from various battery tests in the laboratory. Flight battery data was predictable based on ground test data.

Bogner, R. S.

Scaling Demand Flexibility: Building on 30 Years of Energy Efficiency Success

With electricity consumption across the United States (US) and Canada anticipated to grow, energy efficiency program administrators have a key role to play in helping to ensure energy affordability and reliability in support of the broader economic systems utilities and grid support. Connected, demand side load balancing solutions, such as load shifting heating, ventilation and air conditioning (HVAC) systems and managed charging for electric vehicles (EVs), can dynamically manage energy, allowing for more volumetric electricity consumption without incurring the expense of upgraded transmission and distribution capabilities. When combined, or aggregated, many small loads can be managed to have meaningful impact on energy demand on the grid. Utilities and their partners have an opportunity to leverage decades of experience and the infrastructure needed to assess, design, implement, and measure programs to scale up the adoption of equipment with built-in load flexibility capabilities. Current efforts among a wide variety of electricity system service providers, utilities, standards agencies, regulators, national labs and private industry stakeholders aim to identify common standards, metrics, and methodologies for valuing grid services offered by demand side equipment. By combining those efforts with decades of proven energy efficiency resources, utilities are poised to effectuate a scaling up of equipment with energy management capabilities installed in homes and businesses across the US and Canada. This paper will provide an overview of how utilities are approaching this era of load growth and new peak demands across the United States and Canada. It will highlight the specific strategies that program administrators are employing to advance market transformation for grid-enabled products and devices that have the greatest potential to reduce energy use and increase load flexibility.

Grant, Peter