Search NASA⌕ Search

SEARCH · Search NASA

Results for “integrated storage”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Modeling and Optimizing Pumped Storage in a Multi-stage Large Scale Electricity Market under Portfolio Evolution

To leverage the fast-ramping capability of resources to provide great value to the grid, electricity system operators such as the Midcontinent Independent System Operator (MISO) continue to evolve their approaches for integrating energy storage resources, including pumpedstorage hydro (PSH), into the electricity markets. However, new challenges arise in modeling and optimizing these energy-limited resources across multiple market clearing processes and planning studies with uncertainties and imperfect information. For instance, current market practices of PSH owners specifying pumping/generating hours can result in sub-optimal generation dispatch. Letting grid operators optimize PSH with the consideration of multiple operating modes and energy limitation constraints can potentially bring economic benefits to both the system and the PSH owners. However, in multi-stage clearing process of electricity markets, utilizing the PSH flexibility to deal with realized uncertainties can cause deviation in the multi-stage scheduling processes. The resulting financial risks from the schedule deviation may not be acceptable to PSH owners. In addition, to effectively utilize this energy limited resource, the state of charge (SOC) constraints of PSH needs to be continuously optimized and the marginal cost of deviation need to reflect the expected cost to purchase or sell energy at future times to compensate for deviations. This project aims to develop a prototype enhanced PSH model and improved price signals in the multi-stage market clearing process with proper consideration of the unique characteristics of PSH, in order to better align underlying PSH capabilities with evolving grid needs, particularly including the needs for more frequent and larger cycling to manage variability and uncertainty from renewables.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integration of renewable energy generation and storage systems for emissions reduction in an islanded campus microgrid

Microgrid connected building communities are projected to play an integral part in the clean energy transition. These types of systems, when integrated with distributed energy resources (DERs) such as combined heat and power (CHP), district heating and cooling, renewable generation, and energy storage, can provide clean, reliable power to critical facilities and vulnerable communities. The intermittent nature of renewable generation is a challenge when integrating renewables into any grid system, but particularly in islanded microgrids. The University of Texas at Austin (UT) operates an islanded microgrid powered by a CHP plant, while also utilizing district heating and cooling systems and thermal energy storage (TES). High fidelity operating data was used to develop a validated reduced order model of UT’s integrated campus energy systems to serve as a testbed for use in a case study. Hypothetical renewable energy installations on land owned by UT in west Texas were modeled and integrated into the validated campus models along with battery energy storage (BES). Simulations showed that a combination of renewable energy from wind, and optimally controlled 24-hour thermal and battery storage systems could reduce carbon dioxide emissions on campus by 45.4%. The additional retrofit of burner systems to utilize hydrogen natural gas blends resulted in an overall annual emissions reduction of 54.7%. Carbon capture and storage eliminated the majority of the remaining emissions with increased plant energy expenditure. The presented simulations display the practical limitations of a CHP system complemented by renewable generation and short-term storage in eliminating emissions. Furthermore, results highlight the need for further research and development in long duration storage technologies and hydrogen fueled turbines to increase penetration of renewable energy and reduce emissions.

CHP↗

Impacts of Control, Penetration, and Distribution of Embedded Storage Network in Bulk Power System

The current shift in generation mix from fossil fuel plants towards variable and intermittent renewable energy sources is poised to create a future grid with reduced physical inertia and mismatch between generation and demand. Embedded storage, which is a concept of a coordinated network of storage units sited at the interface between the transmission and distribution system, is proposed as a mechanism to provide a buffer between generation and demand. This paper proposes an automated framework to model and integrate embedded storage in large-scale power systems with industry-grade grid-following (GFL) and grid-forming (GFM) control technologies. More importantly, the developed framework is used to explore the impacts of embedded storage control, penetration, location, and capacity in providing fast frequency response to the grid under contingency events such as generator trips and faults. The framework and study are conducted using the transient-stability simulation tool PSS/E and a realistic model of the Puerto Rico grid as a chosen test system. The simulation results show that GFL and GFM embedded storage, distributed throughout the system, with sufficient penetration and capacity, can effectively improve primary frequency response of the system under the studied contingency events.

Battery Energy Storage, embedded storage, grid-for↗

Hydrogeological assessment of CO2 containment assurance and wellbore integrity at a Gulf Coast storage site

Abstract A large-scale carbon capture and storage (CCS) initiative on the Texas Gulf Coast serves as a premier demonstration of the U.S. Department of Energy’s CarbonSAFE program. Targeting deep saline formations, specifically Oligo-Miocene deltaic sequences, the project aims to establish technical and commercial viability for geologic CO2 storage within a major industrial corridor. This study provides a rigorous hydrogeological assessment to support Class VI permitting by quantifying the high degree of containment security. Utilizing a compositional reservoir simulator, we developed a suite of 27 distinct simulation cases to evaluate vertical plume dynamics near both planned injection wells and proximal legacy infrastructure. To ensure numerical accuracy near wellbores, we implemented a refined mesh strategy, determining that a 5.6 ft × 5.6 ft grid refinement offered the optimal balance between computational efficiency and descriptive precision. The modeling framework utilized a systematic sensitivity-based approach to evaluate the mechanical redundancy of the subsurface system by performing a bounding analysis of wellbore interfaces against hypothetical high-permeability microannuli. By systematically isolating competing physical drivers, including permeability, porosity, gas hysteresis, thermal gradients, salinity, and solubility trapping (quantified via Henry’s law with dynamically adjusted coefficients), this work moves beyond binary assessments to establish a nuanced hierarchy of containment factors. The results confirm that primary trapping mechanisms (e.g., gas hysteresis and solubility), combined with the site's unique geomechanical stratigraphy, significantly restrict vertical mobility and reinforce the robust containment security of the reservoir. Baseline results demonstrate substantial vertical separation between the CO2 plume and the upper confining system, ensuring robust containment. Sensitivity analysis reveals that even under highly conservative bounding scenarios—assuming theoretical 10-Darcy pathways at specific wellbore locations—the 2,900-ft thick multi-layered confining zone remains a reliable barrier. In these hypothetical upper-bound cases, peak upward fluxes of CO2 and saltwater after 15 years of injection remain localized and dissipate rapidly within the lower sections of the confining interval, leaving the integrity of the seal uncompromised. Furthermore, the study identifies that while localized wellbore pathways define theoretical upper bounds of vertical migration, the Area of Review (AoR) is primarily sensitive to regional thermal gradients and hysteresis, which can influence the AoR by over 3,000 acres in pessimistic configurations. Also, primary trapping mechanisms, specifically gas hysteresis and solubility, work in tandem with the Gulf Coast’s unique geomechanical stratigraphy to significantly restrict vertical mobility. Ductile, smectite-rich mudstones facilitate natural borehole convergence and the self-healing of potential conduits, creating a natural geomechanical bridge that effectively mitigates migration potential at both current injection points and legacy-well locations. This comprehensive modeling effort demonstrates that the integration of high-resolution wellbore simulations and regional geomechanical observations confirms the long-term storage security of the studied site, providing a physics-based foundation for industrial-scale CCS deployments. This modeling framework establishes a baseline for future research into coupled geomechanical effects, such as time-dependent borehole convergence, to further refine long-term containment projections. Acknowledgements We thank the Gulf Coast Carbon Center (GCCC) at the Bureau of Economic Geology for foundational research support. We appreciate Alex Bump for technical guidance and David Hoffman for model mesh generation. This work used TACC’s Frontera cluster for simulations and CMG Ltd. software licenses provided to UT-Austin. This material is based upon work supported by the Department of Energy under Award Number DE-FE0032338. Disclaimer This material is based upon work supported by the U.S. Department of Energy’s Fossil Energy and Carbon Management Office under the CarbonSAFE program, award Number DE-FE0032338. The views expressed herein do not necessarily represent the views of the U.S. Department of Energy or the United States Government.

58 GEOSCIENCES↗

Hydrogeological assessment of CO2 containment assurance and wellbore integrity at a Gulf Coast storage site

Abstract A large-scale carbon capture and storage (CCS) initiative on the Texas Gulf Coast serves as a premier demonstration of the U.S. Department of Energy’s CarbonSAFE program. Targeting deep saline formations, specifically Oligo-Miocene deltaic sequences, the project aims to establish technical and commercial viability for geologic CO2 storage within a major industrial corridor. This study provides a rigorous hydrogeological assessment to support Class VI permitting by quantifying the high degree of containment security. Utilizing a compositional reservoir simulator, we developed a suite of 27 distinct simulation cases to evaluate vertical plume dynamics near both planned injection wells and proximal legacy infrastructure. To ensure numerical accuracy near wellbores, we implemented a refined mesh strategy, determining that a 5.6 ft × 5.6 ft grid refinement offered the optimal balance between computational efficiency and descriptive precision. The modeling framework utilized a systematic sensitivity-based approach to evaluate the mechanical redundancy of the subsurface system by performing a bounding analysis of wellbore interfaces against hypothetical high-permeability microannuli. By systematically isolating competing physical drivers, including permeability, porosity, gas hysteresis, thermal gradients, salinity, and solubility trapping (quantified via Henry’s law with dynamically adjusted coefficients), this work moves beyond binary assessments to establish a nuanced hierarchy of containment factors. The results confirm that primary trapping mechanisms (e.g., gas hysteresis and solubility), combined with the site's unique geomechanical stratigraphy, significantly restrict vertical mobility and reinforce the robust containment security of the reservoir. Baseline results demonstrate substantial vertical separation between the CO2 plume and the upper confining system, ensuring robust containment. Sensitivity analysis reveals that even under highly conservative bounding scenarios—assuming theoretical 10-Darcy pathways at specific wellbore locations—the 2,900-ft thick multi-layered confining zone remains a reliable barrier. In these hypothetical upper-bound cases, peak upward fluxes of CO2 and saltwater after 15 years of injection remain localized and dissipate rapidly within the lower sections of the confining interval, leaving the integrity of the seal uncompromised. Furthermore, the study identifies that while localized wellbore pathways define theoretical upper bounds of vertical migration, the Area of Review (AoR) is primarily sensitive to regional thermal gradients and hysteresis, which can influence the AoR by over 3,000 acres in pessimistic configurations. Also, primary trapping mechanisms, specifically gas hysteresis and solubility, work in tandem with the Gulf Coast’s unique geomechanical stratigraphy to significantly restrict vertical mobility. Ductile, smectite-rich mudstones facilitate natural borehole convergence and the self-healing of potential conduits, creating a natural geomechanical bridge that effectively mitigates migration potential at both current injection points and legacy-well locations. This comprehensive modeling effort demonstrates that the integration of high-resolution wellbore simulations and regional geomechanical observations confirms the long-term storage security of the studied site, providing a physics-based foundation for industrial-scale CCS deployments. This modeling framework establishes a baseline for future research into coupled geomechanical effects, such as time-dependent borehole convergence, to further refine long-term containment projections. Acknowledgements We thank the Gulf Coast Carbon Center (GCCC) at the Bureau of Economic Geology for foundational research support. We appreciate Alex Bump for technical guidance and David Hoffman for model mesh generation. This work used TACC’s Frontera cluster for simulations and CMG Ltd. software licenses provided to UT-Austin. This material is based upon work supported by the Department of Energy under Award Number DE-FE0032338. Disclaimer This material is based upon work supported by the U.S. Department of Energy’s Fossil Energy and Carbon Management Office under the CarbonSAFE program, award Number DE-FE0032338. The views expressed herein do not necessarily represent the views of the U.S. Department of Energy or the United States Government.

58 GEOSCIENCES↗

Near isothermal compressed air energy storage system in residential and commercial buildings: Techno-economic analysis

Electrical energy storage systems offer a wide range of options to efficiently manage our power supply infrastructure. Energy and environmental security via renewable resources and energy storage devices will also play a critical role in addressing the supply-demand challenges. A novel energy efficient storage system based on near isothermal compressed air energy storage concept, named as Ground-Level Integrated Diverse Energy Storage (GLIDES) is analyzed for integration with residential and commercial buildings. Additionally, the influence of different configurational aspects on key performance and cost attributes is presented in this study. GLIDES modules in the range of 0.5 kWh–15 kWh configurations were considered for residential buildings whereas 25 kW h–500 kW h modules were considered for commercial buildings. Detailed cost and performance analysis of the GLIDES module proved them to be an effective resource in lowering the peak energy demand and corresponding utility bills.

25 ENERGY STORAGE↗

Short-Term Retrospective Land Data Assimilation Schemes

Subsurface moisture and temperature and snow/ice stores exhibit persistence on various time scales that has important implications for the extended prediction of climatic and hydrologic extremes. Hence, to improve their specification of the land surface, many numerical weather prediction (NWP) centers have incorporated complex land surface schemes in their forecast models. However, because land storages are integrated states, errors in NWP forcing accumulates in these stores, which leads to incorrect surface water and energy partitioning. This has motivated the development of Land Data Assimilation Schemes (LDAS) that can be used to constrain NWP surface storages. An LDAS is an uncoupled land surface scheme that is forced primarily by observations, and is therefore less affected by NWP forcing biases. The implementation of an LDAS also provides the opportunity to correct the model's trajectory using remotely-sensed observations of soil temperature, soil moisture, and snow using data assimilation methods. The inclusion of data assimilation in LDAS will greatly increase its predictive capacity, as well as provide high-quality land surface assimilated data.

Houser, P. R.↗

Development of a Portable Stand-Alone 20 K Brayton Cycle Helium Refrigeration System

From 2012 to 2015, NASA funded development of the Ground Operations Demonstration Unit for Liquid Hydrogen (GODU-LH2) at Kennedy Space Center that scaled up and matured Integrated Refrigeration and Storage (IRAS) technology. IRAS involves the integration of an external helium refrigeration system with a cryogenic storage tank via an internal heat exchanger and allows advanced operations such as zero boiloff and densification of the liquid. The refrigeration system employed for GODU-LH2 was a Linde LR1620 piston-Brayton cycle machine with an RSX helium compressor. The GODU-LH2 system was installed in two separate shipping containers—one housing the cold-box, compressor, and gas management hardware, and the other the water chiller unit—with 480 VAC and 120 VAC electrical power fed from external hardware at the test site, and data capture and controls achieved using four different, independent software packages. From 2017 to 2019, in support of a densified hydrogen loading test program, the entire system was repackaged into a single, 40’ (12 m) shipping container, including the refrigeration system, water chiller, and electrical power distribution hardware, and controls were consolidated into a single Allen Bradley PanelView. Details regarding the design, build-out, and testing of the system will be presented and discussed.

W F Reaves↗

Milestone 1.2.9: Radiolytic Gas Generation Measurements from Helium Backfilled Samples of AA1100 and AA6061 Coupons

Nearly 18 metric tons of aluminum-clad spent nuclear fuel (ASNF) is safely managed by the U.S. Department of Energy (DOE). These assemblies are currently in interim storage, with the intention of extended storage (>50 years) until final disposal. Strategies for the continued safe storage of this material are under evaluation, of which a key criterion is the extent of molecular hydrogen gas (H2) formation from the radiolysis of hydrated (oxy)hydroxide aluminum corrosion layers arising from in-reactor and wet storage conditions. Radiation-induced H2 formation has the potential to compromise cladding and storage canister integrity, in addition to promoting the formation of unfavorable gaseous environments. Consequently, understanding this radiation-induced phenomenon is essential for the development of predictive modeling capabilities to support technical considerations and the identification of radiation related challenges for the extended storage of ASNF. Here, we report radiolytic H2 yields (G-values, G(H2)) from the gamma irradiation of ‘pristine’ and pre-corroded aluminum coupons in helium (He) environments as a function of alloy composition (AA1100 and AA6061), relative humidity, and absorbed gamma dose. Measured yields were lower than corresponding values reported for argon environments, a positive result for proposed extended dry storage strategies that would employ helium as a backfill gas. Interestingly, the presented G(H2)He values are comparable to those previously measured in nitrogen environments, suggesting a He mediated H2 inhibition process, attributed here to Penning ionization.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dynamics near equilibrium for intense beams in a nonlinear integrable focusing channel

Accelerator storage ring designs based on nonlinear integrable Hamiltonian systems provide a novel test-bed for studying the interplay between nonlinear dynamics and space charge at high intensity. In this work, the structure of beam Vlasov equilibria is explored for a constant focusing channel based on the nonlinear focusing potential of the Integrable Optics Test Accelerator. Finally, the dynamics of the single-particle orbits is explored in the combined space charge and external focusing fields as a function of beam current, and the self-consistent relaxation of a mismatched beam to equilibrium is characterized.

43 PARTICLE ACCELERATORS↗

Digital hardware and computer system for a digital image recorder.

Description of the digital memory and related computer system used at the Palomar Mountain Observatory. The memory was designed to have a large number of pixels, a high capacity for each pixel, and fast access for use with a variety of image sensors. As an image integration and storage device, this memory is shown to possess ideal properties, namely, it is strictly linear, has a wide dynamic range, and the image does not deteriorate with time. The observer has a visual display which enables him to monitor the image as it is being integrated.-

Dennison, E. W.↗

Energy Transitions Initiative Partnership Project: Wainwright, Alaska. Cohort 1 Technical Assistance: Assessment of Energy Efficiency, Renewable Energy, and Energy Storage Options

This project identified pathways to reduce energy consumption and enhance indoor environmental quality and resilience of a 1,500-square-foot former federal armory building owned by the tribe as it is renovated as a community multipurpose facility. The scope included thermal evaluation of multiple building efficiency measures, and a techno-economic exploration of an on-site renewable energy and integrated energy storage systems.

25 ENERGY STORAGE↗

G2 Flywheel Module Design

Design of a flywheel module, designated the G2 module, is described. The G2 flywheel is a 60,000 RPM, 525 W-hr, 1 kW system designed for a laboratory environment; it will be used for component testing and system demonstrations, with the goal of applying flywheels to aerospace energy storage and integrated power and attitude control (IPACS) applications. G2 has a modular design, which allows for new motors, magnetic bearings, touchdown bearings, and rotors to be installed without a complete redesign of the system. This design process involves several engineering disciplines, and requirements are developed for the speed, energy storage, power level, and operating environment. The G2 rotor system consists of a multilayer carbon fiber rim with a titanium hub on which the other components mount, and rotordynamics analysis is conducted to ensure rigid and flexible rotor modes are controllable or outside of the operating speed range. Magnetic bearings are sized using 1-D magnetic circuit analysis and refined using 3-D finite element analysis. The G2 magnetic bearing system was designed by Texas A&M and has redundancy which allows derated operation after the loss of some components, and an existing liquid cooled two pole permanent magnet motor/generator is used. The touchdown bearing system is designed with a squeeze film damper system allowing spin down from full operating speed in case of a magnetic bearing failure. The G2 flywheel will enable module level demonstrations of component technology, and will be a key building block in system level attitude control and IPACS demonstrations.

Jensen, Ralph H.↗

Are coupled renewable-battery power plants more valuable than independently sited installations?

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$$10/MWh across ISOs on average. The highest boost occurs in California ($\$$15/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$$12.5/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$$12.5/MWh coupling penalty is reduced to $\$$1.6/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$$2–$\$$13/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Keep it short: Exploring the impacts of configuration choices on the recent economics of solar-plus-battery and wind-plus-battery hybrid energy plants

Coupled renewable-battery powerplants differ from the traditional concept of independent siting of electricity resources within transmission networks. Prior research on the value proposition and cost savings from coupling did not consider the geographic constraint of co-location. This paper fills the gap by assessing how pricing volatility differences between nodes within electricity markets impact the system value of coupled renewable-battery projects as compared to independent VRE and battery installations. We use wholesale power market prices from 2012–2019 across the seven main U.S. independent system operators (ISOs) with a linear optimization program to compare the electricity market value of coupled projects to the value of the same underlying sub-components, deployed separately. We find that additional value from adding a 4-hour battery sized to 50% of renewable-plant nameplate capacity is $\$10$/MWh across ISOs on average. The highest boost occurs in California ($\$15$/MWh), where the value of adding storage to solar rises over time in tandem with increased solar penetration in the region. If renewables and batteries are deployed independently, we estimate that $\$12.5$/MWh of additional value could be achieved because of more flexibility on battery siting and operation. The $\$12.5$/MWh coupling penalty is reduced to $\$1.6$/MWh when considering alternative approaches to integrating battery storage. This result implies that renewable-battery power plants will play an increasing role in electricity systems if they can be built for $\$2$–$\$13$/MWh less than independent projects of comparable size. However, the wide regional variation in coupling penalties, along with the importance of conditions captured in our sensitivity cases, suggests the tradeoff between coupling penalties and savings will vary by situation. Therefore, roles exist for independent and coupled projects from a system optimization perspective.

14 SOLAR ENERGY↗

Performance analysis of integrated Nuclear-Solar Energy system sharing same molten salt thermal energy storage

Advanced nuclear reactors may be deployed with integrated thermal energy storage to improve flexibility and maximize revenue. This presents opportunities for thermal integration with concentrating solar power (CSP) to generate component synergies and/or improve performance. Here in this study, a computational model is developed for an integrated nuclear and CSP system that both share the same molten salt thermal energy storage (TES). Optimized dispatch schedules are developed subject to various market conditions, and the ratio of the nuclear to CSP thermal output is also varied. Performance of the combined system is compared to separate nuclear and solar plants, to determine if there is an overall benefit that can be derived from sharing the TES. Given sufficient volatility in electricity prices (e.g., under CAISO market conditions), synergies of up to 8% in net revenue are observed as a result of sharing the same TES, primarily due to improved revenue from enabling operation of the turbine closer to its design point, as well as being able to better take advantage of higher electricity prices. The synergy benefits are largest when the nuclear and solar plants have similar thermal output. However, when prices are less volatile the opposite behavior can be observed and it can be preferable to operate the nuclear plant as a baseload generator.

14 SOLAR ENERGY↗

A Learning-based Supervisory Control Architecture for Electric Vehicle Charging System Paired with Energy Storages

A Machine Learning-based predictive model is developed for optimal dispatching energy storage system integrated with Electric Vehicle battery charger. The model is effectively trained using transfer learning algorithm and successfully validated via measurement data to achieve high fidelity and accuracy. The study findings provide possibilities for future development of the presented approach to implement computational heavy predictive algorithms with multi-step predictions in emerging modular bidirectional charger topologies to realize vehicle-to-grid (V2G) technology. The online tuning can be explored using the new measurements obtained during the operation, henceforth, enhancing the controller performance for integrating multiple DERs into distribution power networks that shows huge interest for the utilities and regulatory agencies. Multiple operation scenatios have been evaluated and simulation results are discussed to verify intended performance of the proposed control solution.

24 POWER TRANSMISSION AND DISTRIBUTION↗