Search NASA⌕ Search

SEARCH · Search NASA

Results for “interrupt”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Integration of energy storage with diesel generation in remote communities

Highlights Battery energy storage may improve energy efficiency and reliability of hybrid energy systems composed by diesel and solar photovoltaic power generators serving isolated communities. In projects aiming update of power plants serving electrically isolated communities with redundant diesel generation, battery energy storage can improve overall economic performance of power supply system by reducing fuel usage, decreasing capital costs by replacing redundant diesel generation units, and increasing generator system life by shortening yearly runtime. Fast-acting battery energy storage systems with grid-forming inverters might have potential for improving drastically the reliability indices of isolated communities currently supplied by diesel generation. Abstract This paper will highlight unique challenges and opportunities with regard to energy storage utilization in remote, self-sustaining communities. The energy management of such areas has unique concerns. Diesel generation is often the go-to power source in these scenarios, but these systems are not devoid of issues. Without dedicated maintenance crews as in large, interconnected network areas, minor interruptions can be frequent and invasive not only for those who lose power, but also for those in the community that must then correct any faults. Although the immediate financial benefits are perhaps not readily apparent, energy storage could be used to address concerns related to reliability, automation, fuel supply concerns, generator degradation, solar utilization, and, yes, fuel costs to name a few. These ideas are shown through a case study of the Levelock Village of Alaska. Currently, the community is faced with high diesel prices and a difficult supply chain, which makes temporary loss of power very common and reductions in fuel consumption very impactful. This study will investigate the benefits that an energy storage system could bring to the overall system life, fuel costs, and reliability of the power supply. The variable efficiency of the generators, impact of startup/shutdown process, and low-load operation concerns are considered. The technological benefits of the combined system will be explored for various scenarios of future diesel prices and technology maintenance/replacement costs as well as for the avoidance of power interruptions that are so common in the community currently. Graphic abstract Discussion In several cases, energy storage can provide a means to promote energy equity by improving remote communities’ power supply reliability to levels closer to what the average urban consumer experiences at a reduced cost compared to transmission buildout. Furthermore, energy equity represents a hard-to-quantify benefit achieved by the integration of energy storage to isolated power systems of under-served communities, which suggests that the financial aspects of such projects should be questioned as the main performance criterion. To improve battery energy storage system valuation for diesel-based power systems, integration analysis must be holistic and go beyond fuel savings to capture every value stream possible.

25 ENERGY STORAGE↗

Surface Anchoring of Nematic Phase on Carbon Nanotubes: Nanostructure of Ultra-High Temperature Materials

Nuclear energy is a dependable and economical source of electricity. Because fuel supply sources are available domestically, nuclear energy can be a strong domestic industry that can reduce dependence on foreign energy sources. Commercial nuclear power plants have extensive security measures to protect the facility from intruders [1]. However, additional research efforts are needed to increase the inherent process safety of nuclear energy plants to protect the public in the event of a reactor malfunction. The next generation nuclear plant (NGNP) is envisioned to utilize a very high temperature reactor (VHTR) design with an operating temperature of 650-1000°C [2]. One of the most important safety design requirements for this reactor is that it must be inherently safe, i.e., the reactor must shut down safely in the event that the coolant flow is interrupted [2]. This next-generation Gen IV reactor must operate in an inherently safe mode where the off-normal temperatures may reach 1500°C due to coolant-flow interruption. Metallic alloys used currently in reactor internals will melt at such temperatures. Structural materials that will not melt at such ultra-high temperatures are carbon/graphtic fibers and carbon-matrix composites. Graphite does not have a measurable melting point; it is known to sublime starting about 3300°C. However, neutron radiation-damage effects on carbon fibers are poorly understood. Therefore, the goal of this project is to obtain a fundamental understanding of the role of nanotexture on the properties of resulting carbon fibers and their neutron-damage characteristics. Although polygranular graphite has been used in nuclear environment for almost fifty years, it is not suitable for structural applications because it do not possess adequate strength, stiffness, or toughness that is required of structural components such as reaction control-rods, upper plenum shroud, and lower core-support plate [2,3]. For structural purposes, composites consisting of strong carbon fibers embedded in a carbon matrix are needed. Such carbon/carbon (C/C) composites have been used in aerospace industry to produce missile nose cones, space shuttle leading edge, and aircraft brake-pads. However, radiation-tolerance of such materials is not adequately known because only limited radiation studies have been performed on C/C composites, which suggest that pitch-based carbon fibers have better dimensional stability than that of polyacrylonitrile (PAN) based fibers [4]. The thermodynamically-stable state of graphitic crystalline packing of carbon atoms derived from mesophase pitch leads to a greater stability during neutron irradiation [5]. The specific objectives of this project were: (i) to generating novel carbonaceous nanostructures, (ii) measure extent of graphitic crystallinity and the extent of anisotropy, and (iii) collaborate with the Carbon Materials group at Oak Ridge National Lab to have neutron irradiation studies and post-irradiation examinations conducted on the carbon fibers produced in this research project.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Commercialization of New Lattice-Matched Multi-Junction Solar Cells Based on Dilute Nitrides: July 8, 2010 - March 7, 2012

All the milestones for this program were achieved and in most cases, particularly those related to cell performance, more samples were supplied than was required, and the deliverables substantially exceed the performance milestones. Moreover, the cell deliverables sent to NREL for evaluation were cells 4 mm or 5.5 mm, nearly 5 to 10 times larger in area than the 2 mm cells called for in the subcontract, and one of the most common sizes in the CPV industry. For the entire program there were 12 separate cell performance milestones, the most important of which was the 3J cell efficiency. Phase 1 had 2 3J efficiency milestones and Phase 2 had three. For the Phase 1 milestone calling for 38% efficiency, NREL measured a peak efficiency of 41.1%, about 2% higher than the data sheet values of commercial cells at that time. The efficiencies measured in Phase 1 exceed the Phase 2 cell performance milestones in the subcontract’s original Statement of Work. Cells submitted to NREL as part of this subcontract, although not as deliverables, were measured to have a new World Record cell efficiency of 43.5%, breaking the previous World Record by 1.2% absolute. In addition to improved cell performance, during Phase 1 a modeling capability for designing ARCs was developed and verified by comparing the measured current from a cell using a specific ARC with the current predicted by the model. This model was then used to design a new ARC giving lower reflectivity and a corresponding higher cell current. Again the prediction of the model was verified by measured cell properties. In Phase 2, the modeling capability was used to design a glass matched ARC, the type most in use in the CPV industry, which was tuned to the band structure of a 3J cell with a dilute nitride bottom cell. Finally, tools and test methodologies were developed that enable HALT to be applied to cells to determine the operating and destruct limits and to determine or set bounds on the lifetime of the cells in typical CPV operating conditions. As part of this effort a novel HALT system was built that enabled cells to be subjected to light at concentrations up to 80 W/cm 2 , (800 suns) while the cell temperature could be held or cycled between -100C and +180C. As part of the Phase 2 effort the system was modified to enable the light to the cell to be interrupted at a maximum rate of 10 times/second. Tests using interrupted light at >500 suns on cells held at 180C showed no evidence of failure after a total of >22 sun-years of operation at 100C. Another key outcome of the reliability efforts of the program was from high temperature storage tests done independently of the HALT test. There were two key outcomes of this activity: 1) single junction GaInNAs cells showed no evidence of failure under the equivalent of at least 100 years of on-sun time operating at 100C and 2) we can conclude with 95% confidence that the probability of device failure after 30 sun-years of operation at 100C is less than 1.5%, and mostly less than 0.5%. Based on these results there is no reason to believe that dilute nitrides in and of themselves pose a reliability problem for CPV applications and that 3J cells using dilute nitrides have very low probability of failure during the expected 20-30 year life of a CPV power plant.

14 SOLAR ENERGY↗

High Pressure Fire Loop Analysis

The scope will be limited to analyzing the effect of the EFC within the system and how one improperly installed coupling affects the rest of the HPFL system. The discussion will include normal operations, impaired flow, and service interruptions. Normal operations are defined as two-way flow to buildings. Impaired operations are defined as a building that only has one-way flow being provided to the building. Service interruptions will be when a building does not have water available to it. The project will look at the following aspects of the reliability of the HPFL system: mean time to failure (MTTF) of EFCs, mean time between failures (MTBF), series system models, and parallel system models. These calculations will then be used to discuss the reliability of the system when one of the couplings fails. Compare the reliability of two-way feeds versus one-way feeds.

42 ENGINEERING↗

Solar and Energy Storage for Resiliency

Facilitated by a grant from the U.S. Department of Energy, the San Francisco Department of the Environment (SF Environment) is working to overcome regulatory, financial and technical barriers and create a roadmap to build resilience through the implementation of solar with energy storage. One key element of resilience is ensuring the continued operation of shelters and critical emergency management facilities in the immediate aftermath of an earthquake, flood, or other disaster, such as a nearby wildfire. To mitigate interruptions to emergency power at these facilities, the City and County of San Francisco (the “City”) has established “on call” contracts with national diesel generator suppliers. However, relying solely on these suppliers poses significant risks to the City, because the supply of diesel generators in San Francisco may be limited when they are most needed, especially during hurricane season when coastal states face an increased risk of power outages. Furthermore, although diesel generators can provide a few days of power when the electric grid is down, they rely on fuel to do so, and fuel supplies can be interrupted by disasters. To help the City address these challenges, a Resilient Solar and Storage Roadmap study was completed in 2017 that investigated the use of microgrids and standalone solar electric generation with battery storage at emergency shelters. The study identified 67 facilities across the City where solar and battery storage systems could be installed. Out of the 67 facilities, 42 are classified as community shelters, where people can live temporarily and receive medical attention for nonserious injuries, and 25 are libraries where people can gather and have free access to communication/information channels (internet access for communication, news, etc.). At present, none of the emergency shelter facilities have back-up power or generators on site. The Solar and Energy Storage for Resilience project (the “Project) is intended to provide electricity to 67 emergency shelters within the City in the wake of a disaster, by implementing stand-alone solar power generation with battery storage. This report aims to provide an assessment of the economic value and resilience benefits derived from the implementation of a solar and energy storage system at emergency shelters. This assessment is based on quantifiable metrics and grounded in a proven economic benefit-cost analysis (BCA) methodology, which help decision makers assess whether the benefits of a project or policy exceed its total costs from a societal perspective. This is a first-of -its-kind study and it is not meant to be comprehensive. The Project Team hopes that other organizations/municipalities will use this report as a reference and refine it for use in future economic assessments on resiliency at emergency shelters. While the report focuses on a study for the City and County of San Francisco, the methods are applicable to any city or town. The analysis is intended to help the City better prepare for the next large-scale grid outage by weighing the benefits and costs of implementing a solar energy system.

14 SOLAR ENERGY↗

Safety Tests on Irradiated AGR-1 Compacts 3-3-2, 3-2-2, and 6-2-1

Post-irradiation examination (PIE) is in progress on coated particle fuel compacts from the first Advanced Gas Reactor irradiation experiment (AGR-1). The AGR-1 Post-Irradiation Examination Plan, INL/PLN- 2828/Rev. 1, includes safety testing of the irradiated compacts in the Oak Ridge National Laboratory (ORNL) Core Conduction Cooldown Test Facility (CCCTF) facility and the Idaho National Laboratory Fuel Accident Condition Simulator (FACS) to evaluate the effect of elevated temperature on the fuel microstructure and fission product retention. Safety tests will involve heating compacts for 100– 500 hours to maximum temperatures of 1600°C–1800°C, where 1600°C is the expected maximum temperature during a high-temperature gas-cooled reactor depressurization conduction cooldown event, and 1800°C is the expected temperature at which the performance of the SiC layer will begin to degrade. ORNL completed the first AGR-1 post-irradiation compact safety test in FY2011. During the first two quarters of FY2012, three additional safety tests were completed. Each of these three compacts was heated up to a maximum temperature of 1600°C and held at this temperature for a period of 300 hours. The standard heating profile specified in each compact examination plan called for a controlled ramp of the furnace to 1600°C with soaks at 400 and 1250°C, a hold at 1600°C for 300 hours, and then a controlled ramp back down to room temperature. The CCCTF performed as designed, except for a few interruptions while the furnace was being ramped up to 1600°C. These interruptions were caused by several power supply problems and one mechanical problem with the cold finger. The root causes of these issues have been identified and addressed to ensure better reliability for future CCCTF operation.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Software Resilience using Kokkos Ecosystem

Due to the cost of hardware failures within mission critical and scientific applications, it is necessary for software to provide a mechanism to prevent or recover from interruptions. The Kokkos ecosystem is a programming environment that provides performance and portability to many applications that run on DOE supercomputers as well as smaller scale systems. These applications require a higher level of service due to the cost associated with each simulation or the critical nature of the mission. Software resilience enables an application of manage hardware failures reducing the cost of an interruption. Two different resilience methodologies have been added to the Kokkos ecosystem: checkpointing has been added for restart capabilities and a resilient execution model has been added to account for failures in compute devices. The design and implementation of each of these additions are described, and appropriate examples are included for end users.

97 MATHEMATICS AND COMPUTING↗

Selecting and Implementing Resilience Metrics in Existing Energy Sector Models [Slides]

Resilience is a topic receiving much attention in relation to energy systems, with particular attention being paid to the supply of electricity. As a result of the growing interest in energy sector resilience, research communities have proposed a plethora of candidate resilience indicators and metrics, most of which remain immature at different scales and segments within the energy system. A necessary focus of the research community lies in implementing, testing, and validating resilience metrics and analysis approaches in energy sector models, which will be invaluable for informing resilience planning and investment decisions. Recognizing these challenges that need to be addressed, we explore how to effectively integrate resilience considerations into energy sector models and tools. The overarching goal of the effort was to evaluate the data needs, methodologies, and outcomes - including consequences and/or changes in investment or operational decisions due to avoided consequences - based on resilience analysis in a range of existing tools. In particular, we selected five models originally built at NREL to explore non-resilience energy research questions to implement and exercise resilience metrics and analysis approaches. To demonstrate the importance of perspective, we selected models that represent different segments of the energy sector, geographic scales, and modeling approaches. A second important aspect of our effort was the development of generalized power interruption scenarios. These scenarios were intended to help establish a framework for simulating the effects of real-world threats in terms of their impacts on system components and, in turn, power interruption.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

First principles calculations in support of Pu aging: calculating the effects of lattice imperfections on thermodynamics

Plutonium (Pu) has, in theory, well defined crystal structures: its atoms are arranged in regular spatial patterns. But Pu is radioactive, and as its nuclei decay those regular spatial patterns are interrupted. The interruptions are lattice imperfections, which are known to affect how materials respond to their environment. To adequately model Pu, we need to know which lattice imperfections are present, how they interact with each other, and how they affect the material’s response to its environment. The work presented here aims to use density functional theory (DFT) calculations to begin to answer the latter, in particular, how individual lattice imperfections affect measurable effects including thermal expansion (the change in volume in response to a change in temperature), heat capacity (the amount of thermal energy needed to change a material’s temperature), and elastic moduli (a material’s resistance to applied stresses). Pu poses many computational challenges. The $\textit{f}$ electrons require special attention. Of all the elements, Pu has the largest number of electrons that must be included in the calculations. Thermal effects require calculating the phonons (the lattice vibrations), which for systems containing lattice imperfections demand large, complex computational cells - but computational resources limit the size and complexity. With careful restructuring of how the calculations are performed, all these challenges have been met to enable calculations that provide insight into how lattice imperfections affect Pu’s response to its environment. Reported here are the computational challenges and the advances developed to meet them, along with the first results showing the strong effect that one prototype lattice imperfection (an interstitial Pu atom in a delta-phase Pu lattice) has on Pu’s response to its environment.

36 MATERIALS SCIENCE↗

Illinois Compressed Air Energy Storage

Compressed Air Storage Energy (CAES) is one of the few mid- technology readiness level (TRL) energy storage technologies that can address the long-duration infrastructure needed for dealing with variable electric output from renewable energy sources and be reliable backup source for replacing natural gas during supply interruptions. In CAES the goal is to capture and store compressed air in subsurface sedimentary strata when off-peak power is available, or there is a need for grid balancing. The stored high-pressure air is returned to the surface and used to power turbines during reductions in either renewable energy or supply issues with fossil fuels. The Illinois CAES project evaluates the feasibility of capturing surplus electrical energy from renewable sources and off-peak energy at a fossil fuel power plant at the University of Illinois Urbana - Champaign (UIUC) campus. The UIUC Abbott Power Plant uses natural gas and coal to generate electricity (capacity: 35 MWe by coal and 49 MWe by NG). UIUC receives additional electricity from on campus solar farm, and off-campus wind farm. Also, UIUC offsets electricity usage by integrating geothermal energy systems into building heating Also, UIUC offsets steam, hot and chilled water usage by integrating geothermal energy systems into building heating and cooling systems. Furthermore, the two UIUC solar farms (Solar Farm 1 is 21 acres and Solar Farm 2 is 54 acres) to generate 4.68 megawatts (MW) and 12.1 MW, respectively. Campus receives 8.6% of the wind-generated electricity from the Rail Splitter Wind Farm. The project objectives were to design an integrated system to 1) capture surplus electrical energy from renewable sources and the Abbott Power Plant using a CAES system, 2) store both the compressed air and the thermal heat generated by compression in the subsurface as part of an adiabatic system, 3) simulate the movement of the air and heat in the subsurface, 4) recover the compressed air and stored thermal heat to rotate turbine generators during sustained interruption due to weather events or fossil fuel disruptions.

03 NATURAL GAS↗

Spread Spectrum Time Domain Reflectivity for String Monitoring in PV Power Plants (Final Technical Report)

This final report describes the methods and results of applying Spread Spectrum Time Domain Reflectivity (SSTDR) for String Monitoring in PV Power Plants for DE-EE0008169. The project created a new system for both detecting and locating electrical faults in photovoltaic systems. In this work, we address photovoltaic electric faults that are both common and costly. Based on interviews with photovoltaic power plant owners, operators, and maintainers, three types of faults are common and of significant interest: disconnects, ground faults, and arc faults. Disconnects can originate from many sources. They are often due to everyday events, such as lawnmowing (accidentally running over a cable), animals eating through the cables, or degradation that occurs over time due to corrosion or general degradation. Ground faults occur when the cables (for example, due to frayed insolation) connect to the ground, relaying current into the ground. These faults are particularly problematic since the ground faults are often intermittent. That is, ground faults commonly appear during rain storms due to a change in soil conductivity and then disappear when the rain ends. This makes the ground fault difficult to find because while current systems can detect the overall change in voltage and current associated with a ground fault, technicians are necessary to locate the fault. As a result, ground faults may disappear before the technician arrives at the power plant. Hence, locating and fixing ground faults often require multiple trips. We also study arc faults, which can result when nearby conductors create an arc of electrical current through the air. While less common, arc faults can be extremely dangerous. The energetic electrical arc can cause fires and destroy equipment, costing significant damage. Overall all three types of faults cost owners and operators money, either from the destruction of equipment or from technician time. Furthermore, while devices exist for detecting ground faults (ground fault circuit interrupters) and arc faults (arc fault circuit interrupter), these systems only search patterns of electrical current that correspond to each fault. This information cannot be used to locate the fault. In addition, these protection systems experience nuisance trips due to nearby electromagnetic interference, such as from a lawn mower or other motors that produce significant amounts of electromagnetic radiation. Hence, the overall goal of this project is to create an SSTDR tool that provides photovoltaic power plants with more reliable fault detection in addition to the localization of faults. SSTDR works by transmitting electrical signals into the photovoltaic string. Those signals reflect from impedance discontinuities (i.e., disconnects, ground faults, and arc faults). These faults are then detected by measuring the presence of a reflection at the SSTDR and can be located by identifying the location of that reflection in time. In addition, unlike current protection systems, these systems do not experience nuisance trips since their low amplitude, high frequency, and coded signal can by analyzed without interference from the regular operational voltage on the photovoltaic string.

14 SOLAR ENERGY↗

Sequential Decision Making (SDM) for Mesh Refinement and Model Selection in Multiscale, Multi-Physics Applications

Intelligent automation and decision support are needed to enhance computational efficiency and robustness in multiscale and multi-physics problems, including materials science, manufacturing, and climate and weather modeling. Current scientific computing approaches for enabling decisions by scientists fail to explore the role of learning, reasoning, and probabilistic planning. Often these decisions are not performed in real-time during the computation but are made prior to the start of the computation, which must be interrupted in order to make changes to the prior choices. Such interruptions at different stages of the computation increase the total computing time and the need for a human expert to frequently monitor the results. State of art scientific computing methods consist of rule-based algorithms that cannot automatically adapt to a dynamically changing computing environment. The development of a Sequential Decision Making (SDM) framework will automate scientific computing by optimizing the policies for mesh refinement, time-stepping, model and algorithm selection, resource allocation, and pre and post-processing. Our agent SDM framework for scientific computing will consist of data-driven learning (Classifier), automated reasoning (contextual knowledge), and probabilistic planning (Reinforcement Learning). In this project, we focused on three problems to demonstrate our SDM framework on a set of ordinary and partial differential equations. Classification of Lorenz system regions using Feed-Forward Neural Networks examined learning in the SDM framework. On the other hand, reasoning and planning in the SDM framework were used in two problems: adaptive time-stepping for nonlinear ODEs using on-policy RL algorithms, and adaptive mesh refinement for 2-D PDEs using off-policy RL algorithms.

97 MATHEMATICS AND COMPUTING↗

PathTrace and MPVEASI: A Path Analysis Comparative Validation Study

Developed in 2018, PathTrace is a software package built with the intention of making path analysis simple and intuitive. PathTrace is a top-down pathway analysis software where a user is able to explore vulnerable pathways into a facility. The intention of utilizing a software tool like PathTrace is to characterize an existing physical protection system (PPS) and to upgrade the system to achieve a high level of response interruption, or probability of interruption (P I ) of the adversary. There are four steps for conducting path analysis using PathTrace. The first step is to identify an image to use to build the model and scale the model within PathTrace using a section of known distance (wall or fence perimeter, for example). The scaling process will produce a grid of cells through which the user is able to build a model. The second step is to fill out the grid of cells with four categories of materials: Barriers, Detection Areas, Jumps, and Targets. These materials apply associated delay and detection values to the cells in which they are applied. The third step is to represent the adversary and response forces. The adversaries are represented by their capabilities in interacting with the materials identified in step two, and the response is represented by how quickly they will be able to respond to an adversary attack. Finally, the user is able to take all of the information from the previous three steps and perform a Most Vulnerable Path (MVP) analysis. In this stage, the user is able to visualize vulnerable adversary pathways and reason about how to upgrade these pathways to provide a high level of P I .

97 MATHEMATICS AND COMPUTING↗

Estimates of the Economic Impacts of Long-Duration, Widespread Power Disruptions in Puerto Rico

A typical electricity customer in Puerto Rico experienced nearly 27 hours of power interruptions in 2023–with many customers experiencing extremely long duration outages during a single event (i.e., greater than one month). This project involved conducting state-of-the-art surveying to assess the direct costs of power outages occurring across Puerto Rico, developing customer-specific models to estimate future costs over varying outage durations, and comparing these estimates to FEMA’s Value of Unit Service for Electricity. We estimate that a territory-wide power outage may cost customers $\$1$, $\$5$ and $\$29$ billion during one-, 14-, and 30-day interruptions, respectively. However, these are lower-bound estimates because our study focused on direct economic costs and, by necessity, did not fully incorporate (1) indirect impacts to the economy; (2) costs to repair or replace damaged utility infrastructure; and (3) the broader societal consequences including increased morbidity- and mortality-related costs. The information contained in this study can be used to estimate the direct economic value of past or proposed investments in power system resilience. We conclude with a discussion of this study’s limitations and suggest additional research to improve stakeholder understanding of the impacts of power outages across Puerto Rico.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Distribution Feeder Characteristics and Their Resiliency to Natural Hazards

This paper introduces a method and approach for initially screening actions to improve the reliability of distribution systems exposed to three natural hazards (wildlife, weather, and vegetation). The method is well-suited to needs and capabilities of smaller utilities because it relies on readily available information and does not depend on simulations involving detailed engineering models. The method involves first aggregating feeders into like types and then correlating them, separately by hazard, to standard measures of reliability, namely, System Average Interruption Frequency Index (SAIFI) and System Average Interruption Duration Index (SAIDI), and the individual constituents of these measures. The correlations provide both new insights into the efficacy of accepted reliability management practices while and re-confirm long-understood, accepted practices. Importantly, the method does not seek to replace the need for detailed engineering analysis. Instead, in view of the significant costs involved in conducting these more involved analyses, the method is intended to help smaller utilities prioritize their more limited resources to maximize the efficacy of actions they take to improve reliability.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Autonomous Intelligence Measurements and Sensor Systems (AIMS): Gaussian Processes in Remote Sensing: Literature Review

Power grid resilience and reliability is crucial to supporting critical infrastructure. Service interruptions can have devastating consequences to communication, emergency, and transportation services, just to name a few. In addition to infrastructure, power services are crucial to everyday life. Nearly every element of modern-day living relies on a stable and functioning power grid - heating and cooling systems to lighting, refrigeration, telecommunications, and internet access. Interruptions in the power supply can range from minor inconveniences, such as the temporary loss of internet or television services, to more significant problems, like the inability to access medical equipment or emergency services during critical situations. As climate conditions worsen, the reliability of the power grid becomes even more significant. Extreme weather events, such as hurricanes, wildfires, or severe storms, can cause serious damage to power infrastructure, leading to prolonged power outages. Rising temperatures and changing weather patterns can strain the grid, resulting in increased demand for electricity, stressing transmission and distribution systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Customer Impact Evaluation for the 2009 Southern California Edison Participating Load Pilot

The 2009 Participating Load Pilot Customer Impact Evaluation provides evidence that short duration demand response events which cycle off air conditioners for less than thirty minutes in a hot, dry environment do not lead to a significant degradation in the comfort level of residents participating in the program. This was investigated using: (1) Analysis of interval temperature data collected from inside residences of select program participants; and (2) Direct and indirect customer feedback from surveys designed and implemented by Southern California Edison at the conclusion of the program season. There were 100 indoor temperature monitors that were acquired by LBNL for this study that transmitted temperature readings at least once per hour with corresponding timestamps during the program season, June-October, 2009. Recorded temperatures were transferred from the onsite telemetry devices to a mesh network, stored, and then delivered to KEMA for analysis. Following an extensive data quality review, temperature increases during each of the thirty demand response test events were calculated for each device. The results are as follows: (1) Even for tests taking place during outside temperatures in excess of 100 degrees Fahrenheit, over 85 percent of the devices measured less than a 0.5 degree Fahrenheit temperature increase indoors during the duration of the event. (2) For the increases that were observed, none was more than 5 degrees and it was extremely rare for increases to be more than 2 degrees. At the end of the testing season SCE and KEMA designed and conducted a survey of the a facilities and public works managers and approximately 100 customers feedback survey to assess the extent the PLP events were noticed or disrupted the comfort level of participants. While only a small sampling of 3 managers and 16 customer surveys were completed, their responses indicate: (1) No customer reported even a moderate level of discomfort from the cycling-off of their air conditioners during test events; and (2) Very few customers noticed any of the thirty events at all. The results of this study suggest that the impacts on comfort from short-duration interruptions of air-conditioners, even in very hot climates, are for the most part very modest, if they are even noticed at all. Still, we should expect that these impacts will increase with longer interruptions of air-conditioning. By the same token, we should also expect that they will be less significant in cooler climates.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Characterization of Rotating Detonation Engine Injector Response Using Laser-Induced Fluorescence

In this work, rotating detonation engine (RDE) fuel injector response was characterized in a lab-scale linear testing platform. The experimental design consists of a linear extrusion of an RDE cross section and allows rapid interchanging of modular, 3D printed inlet geometries. An array of helium jets was established within a channel, and a single combustion-driven shock pulse was presented at one end. The subsequent injector interruption and recovery were quantified using high-speed acetone planar-laser-induced fluorescence (PLIF). A quartz wall provided optical access to the channel and the injector response was visualized at up to 30 kHz. Three dynamic pressure transducers allowed the shock strength to be quantified along the length of the channel. Timescales associated with jet interruption and recovery were determined by analysis of instantaneous PLIF images and considered in conjunction with the dynamic pressure measurements. Finally, results are presented as a function of pertinent nondimensional parameters and compared with available experimental and computational data in a full, research-scale RDE.

42 ENGINEERING↗