Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser methods”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Porous architecture and thermal properties of thermal barrier coatings deposited by suspension plasma spray

Besides the intrinsic low heat transfer capability of material, the thermal insulation property of thermal barrier coatings (TBCs) also relies on their microstructures. For better understanding the relationship between process parameters, porous architecture, and thermal properties of coatings, YSZ coatings were firstly manufactured by suspension plasma spray (SPS). Afterwards their total porosities were characterized by using the technique of X-ray transmission, the nano/submicro pores in those coatings were detected with Ultra-Small Angle X-ray Scattering (USAXS), and the thermal properties of coatings were measured using the laser flash method. The results indicated that: i) the porous architecture of SPS coatings can be tailored by adapting process parameters. ii) increasing total porosity is an effective means for reducing the heat transfer capability of SPS coatings. iii) nano/submicro pores have higher influence sensitivity on thermal properties than that of larger pores. Increasing the content of nano-submicro pores is therefore more effective for improving the thermal insulation property of SPS coatings. The potential of SPS technique for fabricating TBCs was discussed as well.

36 MATERIALS SCIENCE↗

Digital alloy contact layers for perovskite solar cells

Thin film optoelectronic devices commonly require an individual material to perform multiple functions, but the physical properties of single-composition materials often cannot be tuned to optimize these diverse requirements. The electron selective contact layer in perovskite solar cells is a prime example. The material must simultaneously have optimal conduction band alignment, facilitate carrier extraction, prevent recombination, and provide a chemically stable interface with the notoriously volatile perovskite semiconductor. The pulse-by-pulse nature of the thin-film deposition method pulsed laser deposition (PLD) provides an opportunity to form material alloys where the chemical composition is controlled at the nanometer scale. These digital alloys may prove to be a powerful materials class to meet some of the multifunctional needs of thin film devices. Using PLD to make electron transport layers from ZnO and MgZnO targets, we demonstrate in this paper that digital alloy gradients can be tuned to significantly outperform either of the parent materials in perovskite solar cells.

36 MATERIALS SCIENCE↗

The effect of a transducer’s spatial averaging on an elastodynamic guided wave’s wavenumber spectrum

Elastodynamic guided waves propagate in an elastic solid which makes it difficult, if not impractical, to place a receiving transducer in the direct path of the propagating wave (as one would for an acoustic wave in a fluid medium). Thus, to account for this, receiving transducers are often placed on the surface of the solid waveguide such that the transducer surface is parallel to the wave propagation direction. This transducer orientation introduces spatial averaging, which causes the received signal to have an altered signal amplitude and mode bias. We investigate both of these effects and present a simple model from which we derive a scaling-ratio expression that describes the effects of spatial averaging. Furthermore, we then test its performance using finite-element simulations that incorporate “real-world” assumptions (e.g., transient waves, piezoelectric effects, etc.). The results from the simulations demonstrate that the scaling-ratio can characterize the effects resulting from spatial averaging. The scaling-ratio expression will be particularly useful when designing experiments involving high frequency (small wavelength) guided waves. Lastly, the proposed scaling-ratio expression could be applied to other sensing methods, like Laser Doppler Vibrometry (LDV) or piezoelectric waveguides with inter-digitated transducers, because of its generality. However, the authors are careful to note that the scaling-ratio expression is not intended as a replacement of multi-physics analysis or good experimental design, and the effects of spatial averaging should be avoided whenever possible.

2DFFT↗

Morphology Control of Self-Assembled Three-Phase Au-BaTiO 3 –ZnO Hybrid Metamaterial for Tunable Optical Properties

Microstructural control in metal-dielectric hybrid metamaterials presents enormous opportunities in tailoring the physical properties including the magnetic and optical properties. In this paper, we demonstrate a strong tunability achieved in the microstructure of self-assembled ordered three-phase Au-BaTiO 3 –ZnO hybrid metamaterial along with its optical properties, grown by a pulsed laser deposition method. Varying the growth temperature, deposition frequency, and template thickness evolves the microstructure by tuning the Au and ZnO pillar geometry as well as the shape and size of the Au nanoparticles capping the ZnO nanowires. The three-phase hybrid metamaterials exhibit unique optical properties, including enhanced nonlinear optical properties, hyperbolic dispersion in the visible and near-infrared wavelength region, and tuned epsilon-near-zero (ENZ) wavelength upon varying the deposition parameters. This study suggests that the three-phase hybrid metamaterials present great potential in the microstructure and optical property tuning that can also be applied to other two-phase and three-phase nanocomposite systems.

36 MATERIALS SCIENCE↗

Single-Crystal Growth and Room-Temperature Magnetocaloric Effect of X-Type Hexaferrite Sr 2 Co 2 Fe 28 O 46

X-type hexaferrites have been receiving considerable attention due to their promising applications in many magnetic-electronic fields. However, the growth of single-crystal X-type hexaferrite is still a challenge. Herein we reported, for the first time, the preparation of single crystal X-type hexaferrite Sr 2 Co 2 Fe 28 O 46 (Sr 2 Co 2 X) with high-quality and large size using floating-zone method with laser as the heating source. The crystals show rhombohedral symmetry with space group of R-3m (No. 166, a = 5.8935(1) Å and c = 83.7438(17) Å). Co 2+ and Fe 3+ oxidation states were confirmed by the X-ray absorption near-edge spectroscopy. The prepared Sr 2 Co 2 X exhibits a spin reorientation transition from easy-cone to easy-axis at T 2 of 343 K and a ferrimagnetism–paramagnetism transition at Curie temperature (TC) of ~743 K. The spin reorientation transition was accompanied by magnetocaloric effect (MCE). Both conventional and inverse MCEs were observed near T 2 with a magnetic field applied along the c-axis. The maximum value of the magnetic entropy change along the c-axis was evaluated to be 1.1 J/kg·K for a magnetic field change of 5 T.

36 MATERIALS SCIENCE↗

Laser spectroscopy of indium Rydberg atom bunches by electric field ionization

This work reports on the application of a novel electric field-ionization setup for high-resolution laser spectroscopy measurements on bunched fast atomic beams in a collinear geometry. In combination with multi-step resonant excitation to Rydberg states using pulsed lasers, the field ionization technique demonstrates increased sensitivity for isotope separation and measurement of atomic parameters over previous non-resonant laser ionization methods. The setup was tested at the Collinear Resonance Ionization Spectroscopy experiment at ISOLDE-CERN to perform high-resolution measurements of transitions in the indium atom from the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states to 5s 2 np 2 P and 5s 2 nf 2 F Rydberg states, up to a principal quantum number of n=72 . The extracted Rydberg level energies were used to re-evaluate the ionization potential of the indium atom to be 46,670.107(4)cm -1 . The nuclear magnetic dipole and nuclear electric quadrupole hyperfine structure constants and level isotope shifts of the 5s 2 5d 2 D 5/2 and 5s 2 5d 2 D 3/2 states were determined for 113,115 In. The results are compared to calculations using relativistic coupled-cluster theory. A good agreement is found with the ionization potential and isotope shifts, while disagreement of hyperfine structure constants indicates an increased importance of electron correlations in these excited atomic states. With the aim of further increasing the detection sensitivity for measurements on exotic isotopes, a systematic study of the field-ionization arrangement implemented in the work was performed at the same time and an improved design was simulated and is presented. The improved design offers increased background suppression independent of the distance from field ionization to ion detection.

74 ATOMIC AND MOLECULAR PHYSICS↗

High-resolution infrared spectroscopy of supersonically cooled singlet carbenes: Bromomethylene (HCBr) in the CH stretch region

First high-resolution spectra of cold (~35 K) singlet bromomethylene HCBr in the CH stretching (v 1 ) region from 2770 to 2850 cm-1 are reported using near quantum shot-noise limited laser absorption methods in a slit jet supersonic discharge expansion source. Three rovibrational bands are identified at high S/N (20:1 - 40:1) and rotationally assigned to i) the CH stretch fundamental (v 1 ) band $\tilde{X}$(1,0,0) ← $\tilde{X}$ (0,0,0) and ii) vibrational hot bands ($\tilde{X}$(1,1,0) ← $\tilde{X}$(0,1,0) and $\tilde{X}$(1,0,1) ← $\tilde{X}$(0,0,1)) arising from vibrationally excited HCBr populated in the discharge with single quanta in either the H–C–Br bend (v 2 ) or C–Br stretch (v 3 ) modes. Precision rotational constants are reported for a total of six states, with an experimentally determined CH stretch vibrational frequency (2799.38 cm -1 ) in good agreement with previous low-resolution fluorescence studies. Detailed analysis of the fundamental v 1 band highlights the presence of perturbations in the $\tilde{X}$(1,0,0) level, which we tentatively attribute to arise from the nearby triplet state $\tilde{a}$(0,0,1) through spin-orbit interaction or the multiple quanta $\tilde{X}$(0,2,1) singlet state via c-type Coriolis coupling. Reduced-Doppler resolution (60 MHz) in the slit-jet IR spectrometer permits clear observation of nuclear spin hyperfine structure, with experimental line shapes well reproduced by nuclear quadrupole/spin-rotation coupling constants from microwave studies. Lastly, the a-type to b-type transition intensity ratio for the fundamental CH stretch band is notably larger than predicted by a bond-dipole model, which from high level ab initio quantum calculations (CCSD(T)/PVQZ) can be attributed to vibrationally induced “charge-sloshing” of electron density along the polar C–Br bond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Diagnostics of plasma–liquids systems: Challenges and their mitigation

This article will review two popular methods of laser diagnostics in a plasma–liquid system and generally in low-temperature plasmas. These are Thomson scattering and laser-induced fluorescence. Setting up the plasma–liquid interaction experiment will be described while stressing the important points for laser diagnostics and maintaining conditions for correct and repeatable measurements. In this work, I will discuss the caveats that are encountered when measuring an inherently unstable and collisional system, such as plasma interacting with the liquid and how these challenges impact that data analysis and calibration efforts for these two-diagnostic approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The reaction NH 2 + CH 2 O: Kinetic measurements and computational studies

The reaction of amidogen with formaldehyde is relevant to astrochemistry and couples nitrogen and carbon chemistry in flames. The first measurements of the temperature dependence of the rate constant k were made, over 409–643 K, and are summarized as k = 7.1 × 10 −12 exp(−18.2 kJ mol −1 /RT) cm 3 molecule −1 s −1 with a confidence interval of ±20%. These results address a controversy over the presence of a significant barrier in the addition/elimination pathway leading to the production of formamide between theoretical models that include the zero-point energy of all modes at the transition state and a model that excludes transitional modes. The latter would lead to a negligible barrier, which is inconsistent with the experiments. Contrary to earlier claims, CCSDT(Q)-corrected energies combined with transition state theory yield quantitative accord with the measurements.

Astrochemistry↗

Metrology for femtosecond pulsed x-ray heating in diamond anvil cell experiments at the European XFEL: Revisiting the iron phase diagram up to 150 GPa

The development of pulsed intense x-ray sources, such as free electron laser, offers new avenues for high pressure experiments. Here, we study the feasibility and metrology of x-ray heating in diamond anvil cells at the European x-ray free electron laser. This method enables one to volumetrically heat the sample while inhibiting chemical migration and probing the crystallographic structure of the sample throughout the heating with a high repetition rate. We focus our study on iron, whose phase diagram is well established up to 100 GPa, to explore the possibilities and limitations of this technique. We volumetrically heat iron samples at starting pressures ranging from 10 to 138 GPa, using the x-ray beam pulsed at 4.5 MHz in a serial pump-and-probe experimental design. Experimental challenges arise from temperature gradients within the sample, changes in temperature at the 100 ns timescale, the difficulty of direct temperature estimates, the effect of thermal pressure, and the presence of metastable crystallites due to rapid cycles of heating and cooling. Hence, we develop a multi-crystal-like data processing method that allows us to account for sample heterogeneity in probed conditions. We then calibrate our measurements using known physical properties of iron under pressure. Thermal pressure in our experiments increases from 4% of the isochoric prediction at 10 GPa to 23% at 138 GPa, and we show that our data are in agreement with most previous observations of iron in this pressure range. The method can now be implemented at higher pressures and temperatures and on materials with unknown phase diagrams.

Materials science↗

Calibration of the underground muon detector of the Pierre Auger Observatory

To obtain direct measurements of the muon content of extensive air showers with energy above 10 16.5 eV, the Pierre Auger Observatory is currently being equipped with an underground muon detector (UMD), consisting of 219 10 m 2 -modules, each segmented into 64 scintillators coupled to silicon photomultipliers (SiPMs). Direct access to the shower muon content allows for the study of both of the composition of primary cosmic rays and of high-energy hadronic interactions in the forward direction. As the muon density can vary between tens of muons per m 2 close to the intersection of the shower axis with the ground to much less than one per m 2 when far away, the necessary broad dynamic range is achieved by the simultaneous implementation of two acquisition modes in the read-out electronics: the binary mode, tuned to count single muons, and the ADC mode, suited to measure a high number of them. In this work, we present the end-to-end calibration of the muon detector modules: first, the SiPMs are calibrated by means of the binary channel, and then, the ADC channel is calibrated using atmospheric muons, detected in parallel to the shower data acquisition. The laboratory and field measurements performed to develop the implementation of the full calibration chain of both binary and ADC channels are presented and discussed. The calibration procedure is reliable to work with the high amount of channels in the UMD, which will be operated continuously, in changing environmental conditions, for several years.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Design and calibration of an optically segmented single volume scatter camera for neutron imaging

The Optically Segmented Single Volume Scatter Camera (OS-SVSC) aims to image neutron sources for non-proliferation applications using the kinematic reconstruction of elastic double-scatter events. Our prototype system consists of 64 EJ-204 organic plastic scintillator bars, each measuring 5mm × 5mm × 200mm and individually wrapped in Teflon tape. The scintillator array is optically coupled to two silicon photomultiplier ArrayJ-60035 64P-PCB arrays, each comprised of 64 individual 6x6mm J-Series sensors arranged in an 8 × 8 array. We report on the design details, including component selections, mechanical design and assembly, and the electronics system. The described design leveraged existing off-the-shelf solutions to support the rapid development of a phase 1 prototype. Several valuable lessons were learned from component and system testing, including those related to the detector's mechanical structure and electrical crosstalk that we conclude originates in the commercial photodetector arrays and the associated custom breakout cards. We detail our calibration efforts, beginning with calibrations for the electronics, based on the IRS3D application-specific integrated circuits, and their associated timing resolutions, ranging from 3090ps. With electronics calibrations applied, energy and position calibrations were performed for a set of edge bars using 22 Na and 90 Sr, respectively, reporting an average resolution of 12.07±0.03mm for energy depositions between 900keVee and 1000keVee. We further demonstrate a position calibration method for the internal bars of the matrix using cosmic-ray muons as an alternative to emission sources that cannot easily access these bars, with an average measured resolution of 14.86+-0.29mm for depositions between 900keVee and 1000keVee. The coincident time resolution reported between pairs of bars measured up to 400ps from muon acquisitions. Energy and position calibration values measured with muons are consistent with those obtained using particle emission sources.

47 OTHER INSTRUMENTATION↗

Optical calibration of the SNO+ detector in the water phase with deployed sources

SNO+ is a large-scale liquid scintillator experiment with the primary goal of searching for neutrinoless double beta decay, and is located approximately 2 km underground in SNOLAB, Sudbury, Canada. The detector acquired data for two years as a pure water Cherenkov detector, starting in May 2017. During this period, the optical properties of the detector were measured in situ using a deployed light diffusing sphere, with the goal of improving the detector model and the energy response systematic uncertainties. The measured parameters included the water attenuation coefficients, effective attenuation coefficients for the acrylic vessel, and the angular response of the photomultiplier tubes and their surrounding light concentrators, all across different wavelengths. Finally, the calibrated detector model was validated using a deployed tagged gamma source, which showed a 0.6% variation in energy scale across the primary target volume.

47 OTHER INSTRUMENTATION↗

AI for Experimental Controls at Jefferson Lab

We report the AI for Experimental Controls project is developing an AI system to control and calibrate detector systems located at Jefferson Laboratory. Currently, calibrations are performed offline and require significant time and attention from experts. This work would reduce the amount of data and the amount of time spent calibrating in an offline setting. The first use case involves the Central Drift Chamber (CDC) located inside the GlueX spectrometer in Hall D. We use a combination of environmental and experimental data, such as atmospheric pressure, gas temperature, and the flux of incident particles as inputs to a sequential Neural Network (NN) to recommend a high voltage setting and the corresponding calibration constants in order to maintain consistent gain and optimal resolution throughout the experiment. Utilizing AI in this manner represents an initial shift from offline calibration towards near real time calibrations performed at Jefferson Laboratory.

47 OTHER INSTRUMENTATION↗

Operation modes of the KATRIN experiment Tritium Loop System using 83m Kr

The KArlsruhe TRItium Neutrino (KATRIN) experiment aims to search for the effective electron antineutrino mass with a sensitivity of 0.2 eV (90 % C.L.). In order to achieve this goal, KATRIN measurement phases focusing on the neutrino mass search are alternated with phases of investigations of systematic effects. During these phases, metastable 83m Kr is used as a calibration source. The monoenergetic conversion electrons emitted accompanying the decay of 83m Kr allow a direct access to the starting conditions of β-electrons produced inside the windowless gaseous tritium source (WGTS) of KATRIN. To make use of 83m Kr in the WGTS, the Tritium Loop System, which provides a stable flow of tritium to the WGTS, needs to be operated in special modes. This paper focuses on the technical implementation of these modes and their performance with regard to the achievable 83m Kr-rates, gas densities, and gas compositions inside the WGTS.

47 OTHER INSTRUMENTATION↗

SYNCA: A Synthetic Cyclotron Antenna for the Project 8 Collaboration

Cyclotron Radiation Emission Spectroscopy (CRES) is a technique for measuring the kinetic energy of charged particles through a precision measurement of the frequency of the cyclotron radiation generated by the particle's motion in a magnetic field. The Project 8 collaboration is developing a next-generation neutrino mass measurement experiment based on CRES. One approach is to use a phased antenna array, which surrounds a volume of tritium gas, to detect and measure the cyclotron radiation of the resulting β-decay electrons. To validate the feasibility of this method, Project 8 has designed a test stand to benchmark the performance of an antenna array at reconstructing signals that mimic those of genuine CRES events. To generate synthetic CRES events, a novel probe antenna has been developed, which emits radiation with characteristics similar to the cyclotron radiation produced by charged particles in magnetic fields. This paper outlines the design, construction, and characterization of this Synthetic Cyclotron Antenna (SYNCA). Furthermore, we perform a series of measurements that use the SYNCA to test the position reconstruction capabilities of the digital beamforming reconstruction technique. Finally, we find that the SYNCA produces radiation with characteristics closely matching those expected for cyclotron radiation and reproduces experimentally the phenomenology of digital beamforming simulations of true CRES signals.

47 OTHER INSTRUMENTATION↗

Calibration sources for the LEGEND-200 experiment

In the search for a monochromatic peak as the signature of neutrinoless double beta decay an excellent energy resolution and an ultra-low background around the Q-value of the decay are essential. The LEGEND-200 experiment performs such a search with high-purity germanium detectors enriched in 76 Ge immersed in liquid argon. To determine and monitor the stability of the energy scale and resolution of the germanium diodes, custom-made, low-neutron emission 228 Th sources are regularly deployed in the vicinity of the crystals. Here we describe the production process of the 17 sources available for installation in the experiment, the measurements of their alpha- and gamma- activities, as well as the determination of the neutron emission rates with a low-background LiI(Eu) detector operated deep underground. With a flux of ( 4.27 ± 0.60 stat ± 0.92 syst ) × 10 -4 n / (kBq·s), approximately one order of magnitude below that of commercial sources, the neutron-induced background rate, mainly from the activation of 76 Ge, is negligible compared to other background sources in LEGEND-200.

47 OTHER INSTRUMENTATION↗

Calibration strategy of the PROSPECT-II detector with external and intrinsic sources

This paper presents an energy calibration scheme for an upgraded reactor antineutrino detector for the Precision Reactor Oscillation and Spectrum Experiment (PROSPECT). The PROSPECT collaboration is preparing an upgraded detector, PROSPECT-II (P-II), to advance capabilities for the investigation of fundamental neutrino physics, fission processes and associated reactor neutrino flux, and nuclear security applications. P-II will expand the statistical power of the original PROSPECT (P-I) dataset by at least an order of magnitude. The new design builds upon previous P-I design and focuses on improving the detector robustness and long-term stability to enable multi-year operation at one or more sites. The new design optimizes the fiducial volume by elimination of dead space previously occupied by internal calibration channels, which in turn necessitates the external deployment. In this paper, we describe a calibration strategy for P-II. Here, the expected performance of externally deployed calibration sources is evaluated using P-I data and a well-benchmarked simulation package by varying detector segmentation configurations in the analysis. The proposed external calibration scheme delivers a compatible energy scale model and achieves comparable performance with the inclusion of an additional AmBe neutron source, in comparison to the previous internal arrangement. Most importantly, the estimated uncertainty contribution from the external energy scale calibration model meets the precision requirements of the P-II experiment.

47 OTHER INSTRUMENTATION↗