Search NASA⌕ Search

SEARCH · Search NASA

Results for “laser resonators”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Modeling of the initiation and evolution of a laser-ionized column in the lower atmosphere - 314.5 nm wavelength resonant multiphoton ionization of naturally occurring argon

A 3+1 resonant multiphoton ionization process in naturally occurring argon is studied at 314.5 nm as a candidate for providing a long ionized channel through the atmosphere. Results are presented which indicate peak electron densities up to 10 exp 8/cu cm can be created using laser intensities on the order of 10 exp 8 W/sq cm.

Fetzer, G. J.↗

Probing the Composition of Primitive Solar System Materials with a Compact Laser Mass Spectrometer

To contribute to and complement our understanding of the processes governing the formation,distribution, and evolution of primitive materials throughout the solar system, it will be critical toform connections between broad remote sensing spectroscopic surveys, laboratorymeasurements of analogs and samples delivered to Earth, and in situ measurements of thesurface composition on future primitive body missions. Recently, a laboratory prototypeemploying resonance two-step laser mass spectrometry [Getty et al., 2012] has been coupledto a cryogenic sample stage to enable measurements of analog samples that are relevant tothese fundamental questions. Analyses of mineral-aromatic mixtures and meteorite powderswill be presented. Our goals are twofold: (1) to conduct laboratory studies on solar systemanalog, meteoritic, and potentially returned samples to elucidate composition, and (2) toprovide a compact but capable analytical instrument for discovery-driven in situ interrogationof surface chemistry on a future mission, such as to a Trojan asteroid, comet, or icy moon.

Getty, Stephanie A.↗

Coherent microwave scattering from resonance enhanced multi-photon ionization (Radar REMPI): A review

Coherent microwave scattering from laser-induced plasmas, including weakly ionized plasma, laser sparks, Multiphoton Ionization (MPI), and Resonance Enhanced Multi-Photon Ionizations (Radar REMPI) has achieved much successes in plasma, reactive and nonreactive flow diagnostics. Under illumination of microwaves (Radar), electrons inside the laser-induced plasma oscillate with the electric field of the microwave and re-radiate from the electrons forming coherent scattering. In the far-field approximation, the microwave scattering from the small volume plasma reflects the generation and evolution of unbounded electrons inside the plasma, when the microwave wavelength is much greater than the size of the plasma and the skin layer depth at the microwave frequency is larger than the size of the plasma. Laser excitation schemes, microwave detection methods, calibration of microwave scattering, and the novel applications of the technique have been significantly expanded and improved. Furthermore, this review paper summarizes physical principles, various REMPI excitation schemes for atomic and molecular species, and temperature measurements in plasma and reactive flows. Discussions on new research directions and applications are given at the end.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generalised hyper-Ramsey spectroscopy of two-level atoms in an optically dense medium

The peculiarities of Ramsey resonance and its sensitivity to the light shift from an optically dense medium of cold atoms are investigated. Different composite pulse protocols for clock spectroscopy, including hyper-Ramsey, modified and generalised hyper-Ramsey schemes, are compared. Error signals change significantly due to the processes of absorption and dispersion in the atomic medium. The dependence of the position of the central fringe resonance with a residual uncompensated light shift of the atomic transition is studied with the attenuation of the radiation intensity in the medium taken into account. It is shown that using a combination of generalised hyper-Ramsey error signals allows one to suppress the sensitivity to the light shift for any length of the medium. (laser cooling of atoms)

74 ATOMIC AND MOLECULAR PHYSICS↗

Theoretical studies of Resonance Enhanced Stimulated Raman Scattering (RESRS) of frequency doubled Alexandrite laser wavelengths in cesium vapor

This work focused on understanding the effects of arbitrary transverse and longitudinal relaxation rates on the susceptibilities of coherently driven three-level systems. The approximation of a single relaxation rate often made in previous work is strongly invalidated by the variation in the spontaneous emission lifetime between various atomic level pairs in systems such as cesium. It is of great importance to the problem of nonlinear infrared generation to determine the dependence of both real and imaginary susceptibility on relaxation rates. The imaginary susceptibility on the pump transition determines the absorption of pump photons and the imaginary susceptibility on the laser transition determines the spectral dependence of the gain. This is of particular importance for pure Raman emission (i.e., absorption at linecenter of the gain transition) as it determines the tunability characteristics we are aiming to predict. The real susceptibility is important when cavities are used at the signal field as this will determine the loaded resonance of the Raman oscillator. Researchers show that in some cases which result from having different relaxation rates mode splitting may result, allowing more than one frequency to have the same Raman wavelength, possibly resulting in a temporal instability.

Lawandy, N. M.↗

Accurate simulation of direct laser acceleration in a laser wakefield accelerator

In a laser wakefield accelerator (LWFA), an intense laser pulse excites a plasma wave that traps and accelerates electrons to relativistic energies. When the pulse overlaps the accelerated electrons, it can enhance the energy gain through direct laser acceleration (DLA) by resonantly driving the betatron oscillations of the electrons in the plasma wave. The traditional particle-in-cell (PIC) algorithm, although often the tool of choice to study DLA, contains inherent errors due to numerical dispersion and the time staggering of the electric and magnetic fields. Furthermore, conventional PIC implementations cannot reliably disentangle the fields of the plasma wave and laser pulse, which obscures interpretation of the dominant acceleration mechanism. Here, a customized field solver that reduces errors from both numerical dispersion and time staggering is used in conjunction with a field decomposition into azimuthal modes to perform PIC simulations of DLA in an LWFA. Comparisons with traditional PIC methods, model equations, and experimental data show improved accuracy with the customized solver and convergence with an order-of-magnitude fewer cells. Furthermore, the azimuthal-mode decomposition reveals that the most energetic electrons receive comparable energy from DLA and LWFA.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Single-shot diffusion measurement in laser-polarized Gas

A single-shot pulsed gradient stimulated echo sequence is introduced to address the challenges of diffusion measurements of laser polarized 3He and 129Xe gas. Laser polarization enhances the NMR sensitivity of these noble gases by >10(3), but creates an unstable, nonthermal polarization that is not readily renewable. A new method is presented which permits parallel acquisition of the several measurements required to determine a diffusive attenuation curve. The NMR characterization of a sample's diffusion behavior can be accomplished in a single measurement, using only a single polarization step. As a demonstration, the diffusion coefficient of a sample of laser-polarized 129Xe gas is measured via this method. Copyright 1999 Academic Press.

Non-NASA Center↗

Soft x-ray high-harmonic generation in an anti-resonant hollow core fiber driven by a 3 μ m ultrafast laser

High-harmonic upconversion driven by a mid-infrared femtosecond laser can generate coherent soft x-ray beams in a tabletop-scale setup. Here, we report on a compact ytterbium-pumped optical parametric chirped pulse amplifier (OPCPA) laser system seeded by an all-fiber front-end and employing periodically poled lithium niobate (PPLN) nonlinear media operated near the pulse fluence limits of current commercially available PPLN crystals. The OPCPA delivers 3 µm wavelength pulses with 775 µJ energy at 1 kHz repetition rate, with transform-limited 120 fs pulse duration, diffraction-limited beam quality, and ultrahigh 0.33% rms energy stability over >18 h. Using this laser, we generate soft x-ray high harmonics (HHG) in argon gas by focusing into a low-loss, high-pressure gas-filled anti-resonant hollow core fiber (ARHCF), generating coherent light at photon energies up to the argon L-edge (250 eV) and carbon K-edge (284 eV), with high beam quality and ∼1% rms energy stability. This work demonstrates soft x-ray HHG in a high-efficiency guided-wave phase matched geometry, overcoming the high losses inherent to mid-IR propagation in unstructured waveguides, or the short interaction lengths of gas cells or jets. The ARHCF can operate in the long term without damage and with the repetition rate, stability, and robustness required for demanding applications in spectromicroscopy and imaging. Finally, we discuss routes for further optimizing the soft x-ray HHG flux by driving He at higher laser intensities using either the signal (1.5 μm) or idler wavelengths (3 μm).

Femtosecond lasers↗

Off-axis coherently pumped laser

A coherently optically pumped laser system is described. A pump laser beam propagates through a laser medium contained in a degenerate cavity resonator in a controlled multiple round trip fashion in such a way that the unused pump beam emerges from an injection aperture at a different angle from which it enters the resonator. The pump beam is angularly injected off of the central axis of the resonator body whereupon the pump beam alternately undergoes spreading and focusing while pumping the laser medium by a process of resonant absorption. The emergent pump beam can also be used as a second pump beam source by being reinjected back into the cavity or it can be used for pumping another laser.

Koepf, G. A.↗

Unconventional inertial sensors.

Inertial sensors reviewing ring laser, electrostatic fluid sphere, magnetic resonance, superconductivity gyroscope, relativistic rotating tensor, vortex rate and quantum mechanical effect sensing

INERTIAL ACCELEROMETER↗

An Efficient Single Frequency Ho:YLF Laser for IPDA Lidar Applications

A highly efficient, versatile, single frequency 2-micron pulsed laser can be used in a pulsed Differential Absorption Lidar (DIAL) / Integrated Path Differential Absorption (IPDA) instrument to make precise, high-resolution measurements to investigate sources and sinks of CO2. For a direct detection IPDA lidar, the desired 2 m Ho:YLF laser should generate 30-40 mJ pulses at the repetition rate of 100 to 200 Hz, with short pulse length (<100 ns) and better than 2% wall plug efficiency. A Tm fiber laser in-band pumped Ho:YLF laser has been developed to meet this technical challenge. This Ho:YLF laser is designed in a four mirror ring resonator with bow tie configuration, which helps to obtain high beam quality. It is end-pumped by a 40 W linearly polarized Tm fiber laser at 1.94μm. The resonator length is 1.10 meters with output coupler reflectivity at 45%. The laser crystal size is 3 x 3 x 60 mm (w, h, l) with a doping concentration of 0.5% Holmium. The laser beam and pump beam are mode-matched in the active medium. Thus, the pump and laser beams have the same confocal parameters. Mode-matching is also helpful for operating the laser in a single transverse mode. The laser beam waist is slightly less than 0.5 mm at the center of the laser crystal. Based on quasi-four level modeling, pump absorption and saturation depend on laser intensity. Laser amplification and saturation also depend on the pump intensity in the crystal. The laser is injection seeded to obtain the single frequency required by an IPDA lidar measurement. The seed beam is entered into the resonator through an output coupler. The laser is mounted on a water cooled optical bench for stable and reliable operation. The size of the optical bench is 22.16 x 9.20 x 1.25 inches. It is stiffened so that the laser can be operated in any orientation of the optical bench. This packaged Ho:YLF laser is designed for either mobile trailer or airborne platform operation. The engineering prototype Ho:YLF laser has been fully characterized to demonstrate laser performance. Figure 1 shows the laser output power as a function of pump power at different pulse repetition rates from 100 Hz to 333 Hz. The threshold of the laser is less than 14 W. The slope efficiencies are 28%, 40%, 41% and 43% for pulse repetition rates of 100, 200, 250 and 333 Hz, respectively. Maximum power increases with the pulse repetition rate. Output power of 4.2 W, 6 W, 6.7 W, and 7.7 W is achieved for pulse repetition rates of 100, 200, 250 and 333Hz, respectively. This represents the optical conversion efficiency of 16.7%, 22.4%, 23.7%, and 26.5% at these various pulse repletion rates. It is the most efficient and compact Ho:YLF laser demonstrated in the high pulse energy (>20mJ) and moderate pulse repetition rate (100's Hz) operation range. As shown in Figure 1, the maximum pulse energy at 100 Hz is 42 mJ. This is limited due to optical damage. The laser stability is characterized and found to be very stable. A relative pulse energy standard deviation of 2% was measured. The beam quality of the Ho:YLF was measured by a Spiricon infrared laser beam camera. Figure 2 shows the beam profile image of the laser. Both the X-profile of the beam (horizontal direction) and the Y-profile of the beam (vertical direction) are well fitted by a Gaussian profile. The qualitative beam quality measurement shows excellent beam quality in both axis. The M-square value for the laser beam is measured at 1.06 and 1.09 for the x and y axis respectively.-

Yu, J.↗

Diode injection - seeded, 940 nanometer (nm), titanium - sapphire laser for H2O DIAL (differential absorption lidar), measurements

Differential absorption of laser radiation by various molecular species represents both a selective and a sensitive method of measuring specific atmospheric constituents. DIAL measurements can be carried out via two different means. Both involve using two laser pulses with slightly different wavelengths (lambda), (one lambda at a strong absorption line of the molecule of interest, the other detuned into the wing of the line), and comparing the attenuation of the pulses. One approach relies on scattering of the radiation from some conveniently located topographical target. In the other technique elastic scattering from atmospheric aerosols and particulates is used to return the radiation to the lidar receiver system. This case is referred to as the differential absorption and scattering technique, and is the technique we are interested in to measure water vapor at 940 nm. The 940 nm wavelength is extremely desirable to atmospheric scientist interested in accurate DIAL measurements of H2O in the upper and lower troposphere. Simulated measurements using approximately 940 nm and 815 nm lasers at a range of altitudes and experimental conditions are shown. By offering access to larger absorption cross-sections, injected seeded, 940 nm DIAL laser transmitters would allow for more accurate water profile measurements at altitudes from 6 to 16 km than is currently possible with 730 nm and 815 nm DIAL laser transmitters. We have demonstrated the operation of an injected seeded titanium-sapphire (TS) laser operating at approximately 940 nm with an energy of more than 90 mJ per pulse. The TS laser is pumped by a commercial, 600 mJ, 532 nm, 10 Hz Nd:YAG laser. The slope efficiency of the laser using a flat 50 percent R output coupler and a 10 m end-mirror is shown. The laser was injected seeded with a CW, AlGaAs, semiconductor diode laser which had an output of 83 mW. The CW diode seed beam was introduced into the TS laser cavity through a HR end-mirror. When the diode beam is aligned to the TS resonator, it controls the TS laser output wavelength and its spectral line width with the required resolution for DIAL applications. This work supports the need for the development of 940 nm, titanium-sapphire DIAL transmitters.

Miller, George E.↗

Laser-induced fluorescence of filament-produced plasmas

Self-guided ultrafast laser filaments are a promising method for laser beam delivery and plasma generation for standoff and remote detection of elements and isotopes via filament-induced breakdown spectroscopy (FIBS). Yet, there are several challenges associated with the practical application of FIBS, including delivery of sufficient laser energy at the target for generating plasma with a copious amount of emission signals for obtaining a high signal-to-noise ratio. Here, in this study, we use laser-induced fluorescence (LIF) to boost the emission signal and reduce self-reversal in the spectral profiles. Ultrafast laser filaments were used to produce plasmas from an Al 6061 alloy target at various standoff distances from 1 to 10 m. For LIF emission enhancement, a narrow linewidth continuous-wave laser was used in resonance with a 394.40 nm Al I resonant transition, and the emission signal was monitored from the directly coupled transition at 396.15 nm. Emission signal features of Al I are significantly enhanced by resonant excitation. In addition, LIF of filament ablation plumes reduces the self-reversal features seen in the thermally excited spectral profiles. Time-resolved two-dimensional fluorescence spectroscopy was performed for evaluating the optical saturation effects, which are found to be non-negligible due to high Al atomic densities in the filament-produced plasmas.

47 OTHER INSTRUMENTATION↗

Acoustoelastic characterization of plates using zero group velocity Lamb modes

Acoustoelasticity, a characteristic of material anharmonicity, gives rise to a link between wave propagation velocity and the stress state in materials. Ultrasonic techniques to monitor this coupling, particularly with high sensitivity and in a noncontact manner, can have widespread application both in the quantification of applied and residual stress and in the characterization of nonlinear material behavior through measurement of higher order elastic constants. Here, we use a laser ultrasonic technique to excite and detect zero group velocity (ZGV) Lamb wave resonances in aluminum plates under uniaxial loading. A laser line source is used to excite these resonances at different orientations with respect to the applied load, and the signals are detected using an interferometer. The effects of stress and source orientation on ZGV resonance frequencies are validated using the theory of acoustoelastic Lamb wave propagation. In addition, a model-based inversion technique is used to extract Murnaghan's third-order elastic constants from measurements of the stress dependence of the first two ZGV modes generated parallel and perpendicular to the applied load. Laser generation and detection of ZGV resonances is shown to be an effective and powerful approach for the noncontact and nondestructive acoustoelastic characterization of elastic waveguides.

36 MATERIALS SCIENCE↗

Photorefractivity in WGM resonators

We report on observation of photorefractive effects in whispering gallery mode resonators made of as-grown and magnesium doped lithium niobate and lithium tantalate in the near as well as far infrared. The effects manifested themselves as dynamic modification of the spectra as well as quality factors of the resonators coupled to the laser radiation. We have observed a significant (exceeding 10-4) change of the ordinary index of refraction of all the materials exposed with 780 nm light. Photorefractive effects have also been detected at 1550 nm. Our experiments support the conclusion that the photorefractivity does not have a distinct red boundary. We show that the maximum saturated refractive index change in the infrared is of the same order of magnitude as in the visible light.

optical resonator↗

Cross-beam energy transfer saturation by ion trapping-induced detuning

The performance of direct-drive inertial confinement fusion implosions relies critically on the coupling of laser energy to the target plasma. Cross beam energy transfer (CBET), the resonant exchange of energy between intersecting laser beams mediated by ponderomotively driven ion-acoustic waves (IAW), inhibits this coupling by scattering light into unwanted directions. Furthermore, the variety of beam intersection angles and varying plasma conditions in an implosion results in IAWs with a range of phase velocities. Here we show that CBET saturates through a resonance detuning that depends on the IAW phase velocity and that results from trapping-induced modifications to the ion distribution functions. For smaller phase velocities, the modifications to the distribution functions can rapidly thermalize in the presence of mid-Z ions, leading to a blueshift in the resonant frequency. For larger phase velocities, the modifications can persist, leading to a redshift in the resonant frequency. Ultimately, these results may reveal pathways towards CBET mitigation and inform reduced models for radiation hydrodynamics codes to improve their predictive capability.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗