Search NASA⌕ Search

SEARCH · Search NASA

Results for “level sensor”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Reversible parts-per-trillion-level detection of perfluorooctane sulfonic acid in tap water using field-effect transistor sensors

Widespread, persistent and toxic per- and polyfluoroalkyl substances (PFAS) pose a major threat to water systems and human health. Current detection methods are relatively expensive, slow and complex, underscoring the need for more accessible alternatives to meet increasingly stringent PFAS regulations. Here, in this study, we present an ultrasensitive sensing platform for perfluorooctane sulfonic acid detection in tap water with a reporting limit ( ~ 250 parts per quadrillion) lower than the US Environmental Protection Agency’s regulatory standard (4 parts per trillion), using a remote gate field-effect transistor featuring β-cyclodextrin (β-CD)-modified reduced graphene oxide as the sensing membrane. The sensor exhibits excellent selectivity against common inorganic ions, natural organic matter and select organic pollutants in tap water. The reversible and rapid response ( < 2 min) indicates the potential of remote gate field-effect transistor for continuous in-line monitoring. Mechanistic studies using quartz crystal microbalance and molecular dynamics simulations reveal key roles of analyte adsorption and charge properties in sensing performance and offer insights for designing more selective PFAS capture probes.

Wang, Yuqin [University of Chicago, IL (United Sta↗

Electronic Structures, Bonding Configurations, and Band-Gap-Opening Properties of Graphene Binding with Low-Concentration Fluorine

To better understand the effects of low-level fluorine in graphene-based sensors, first-principles density functional theory (DFT) with van der Waals dispersion interactions has been employed to investigate the structure and impact of fluorine defects on the electrical properties of single-layer graphene films. The results show that both graphite-2H and graphene have zero band gaps. When fluorine bonds to a carbon atom, the carbon atom is pulled slightly above the graphene plane, creating what is referred to as a CF defect. The lowest-binding energy state is found to correspond to two CF defects on nearest neighbor sites, with one fluorine above the carbon plane and the other below the plane. Overall this has the effect of buckling the graphene. The results further show that the addition of fluorine to graphene leads to the formation of an energy band (BF) near the Fermi level, contributed mainly from the 2p orbitals of fluorine with a small contribution from the porbitals of the carbon. Among the 11 binding configurations studied, our results show that only in two cases does the BF serve as a conduction band and open a band gap of 0.37 eV and 0.24 eV respectively. The binding energy decreases with decreasing fluorine concentration due to the interaction between neighboring fluorine atoms. The obtained results are useful for sensor development and nanoelectronics.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Indoor versus Outdoor PM 2.5 Concentrations during the 2025 Los Angeles Fires Using the PurpleAir Sensor Network

In January 2025, a series of fast-moving wildland-urban-interface (WUI) fires swept through the Los Angeles (LA) metropolitan area, causing severe air pollution. While the impacts of WUI fires on outdoor air quality have been extensively studied, indoor exposure remains less understood, despite most people sheltering indoors during WUI fires. Here, this study investigates the spatial and temporal patterns of indoor and outdoor PM 2.5 concentrations across the South Coast Air Basin, with a focus on LA County during the LA fires. Using high-resolution data from co-located indoor and outdoor PurpleAir (PA) sensors, we analyze hourly PM 2.5 levels and indoor/outdoor ratios. Outdoor PM 2.5 concentrations spiked sharply during the fires, reaching unhealthy levels exceeding 130 μg/m 3 , compared to the mean concentration (12 μg/m 3 ) during non-fire hours. Indoor concentrations also increased, though to a lesser extent, peaking around 60 μg/m 3 compared to a mean of 7 μg/m 3 during non-fire hours. This reflects the partial shielding that indoor environments provide from outdoor air pollution. The mean (0.42) and median (0.29) indoor/outdoor PM 2.5 ratios during LA fire hours were lower than the mean (0.93) and median (0.66) ratios during non-fire hours. Indoor/outdoor PM 2.5 ratios across sensors showed a wide distribution, reflecting differences in building characteristics and occupant behavior, such as indoor activities and the use of air purifiers. These findings emphasize the need for guidance and interventions to reduce indoor PM 2.5 exposure and protect public health during extreme WUI fire events.

2025 Los Angeles Fires↗

Measuring Coastal Boating Noise to Assess Potential Impacts on Marine Life

Article requested for submission in Sea Technology Magazine describing the Underwater Noise From Small Boats. An Overlooked Component of the Acoustic Environment in Coastal Areas. Underwater noise and its effects on marine life deserve attention as human activity in the marine environment increases. Noise can affect fish and marine mammals in ways that are physiological, as in auditory threshold shifts, and behavioral, as in changes in foraging habits. One anthropogenic source of underwater noise that has received little attention to date is recreational boating. Coastal areas and archipelago regions, which play a crucial role in the marine ecosystem, are often subject to high levels of boat traffic. In order to better understand the noise produced by a small powerboat, a test was conducted in Sequim Bay, Washington, using an instrumented research vessel and multiple acoustic sensors. The broadband noise and narrowband peak levels were observed from two different locations while the boat was operated under various conditions. The results, combined with background noise levels, sound propagation and local boat traffic patterns, can provide a picture of the total boating noise to which marine life may be subjected.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

A theoretical study of a nano-opto-mechanical sensor using a photonic crystal-cantilever cavity

In this simulation study, integration of a nanocantilever inside a two-dimensional (2D) photonic crystal (PC) cavity resulted in a unique photonic crystal-cantilever cavity (PC 3 ), where the cantilever served as a tunable mechanical defect of the PC slab. Strong nano-opto-mechanical interactions between the cantilever and the defect-mode field inside the PC 3 gave rise to a high sensitivity of the resonance wavelength to surface stress-induced cantilever deflection. Mechanical and optical responses of the PC 3 to surface stress changes on the cantilever surface were studied by using a finite-element method (FEM) and a finite-difference time-domain (FDTD) method, respectively. Theoretical analysis revealed that the devised PC 3 sensor could resolve a conservative minimum surface stress at the level of ~0.8 mN m -1 , representing state-of-the-art cantilever sensor performance. Also, the PC 3 sensor design used an ultracompact structure with an on-chip optical length of only several microns, while a conventional reflected laser beam detection scheme requires a ~1 m long free-space optical path.

36 MATERIALS SCIENCE↗

Geophysical and Planetary Acoustics on Balloons

Natural events and human activity often generate acoustic waves capable of traveling tens to tens of thousands of kilometers across the globe. Ground-based acoustic sensors are limited to dry land and often suffer from wind noise. In contrast, balloon borne acoustic sensors can cross oceans, polar ice caps, and other inhospitable areas, greatly expanding sensor coverage. Since they move with the mean wind speed, their background noise levels are exceptionally low. In the last six years, such sensors have recorded sounds from colliding ocean waves, surface and buried chemical explosions, thunder, wind/mountain interactions, wind turbines, aircraft, and possibly meteors and the aurora. These results have led to new insights on acoustic heating of the upper atmosphere, the detectability of underground explosions, and directional sound fields generated by ocean waves.

47 OTHER INSTRUMENTATION↗

A Self-Sustained CPS Design for Reliable Wildfire Monitoring

Continuous monitoring of areas nearby the electric grid is critical for preventing and early detection of devastating wildfires. Existing wildfire monitoring systems are intermittent and oblivious to local ambient risk factors, resulting in poor wildfire awareness. Ambient sensor suites deployed near the gridlines can increase the monitoring granularity and detection accuracy. However, these sensors must address two challenging and competing objectives at the same time. First, they must remain powered for years without manual maintenance due to their remote locations. Second, they must provide and transmit reliable information if and when a wildfire starts. The first objective requires aggressive energy savings and ambient energy harvesting, while the second requires continuous operation of a range of sensors. To the best of our knowledge, this paper presents the first self-sustained cyber-physical system that dynamically co-optimizes the wildfire detection accuracy and active time of sensors. The proposed approach employs reinforcement learning to train a policy that controls the sensor operations as a function of the environment (i.e., current sensor readings), harvested energy, and battery level. Here, the proposed cyber-physical system is evaluated extensively using real-life temperature, wind, and solar energy harvesting datasets and an open-source wildfire simulator. In long-term (5 years) evaluations, the proposed framework achieves 89% uptime, which is 46% higher than a carefully tuned heuristic approach. At the same time, it averages a 2-minute initial response time, which is at least 2.5× faster than the same heuristic approach. Furthermore, the policy network consumes 0.6 mJ per day on the TI CC2652R microcontroller using TensorFlow Lite for Micro, which is negligible compared to the daily sensor suite energy consumption.

54 ENVIRONMENTAL SCIENCES↗

Performance Analysis of Phase 2 Tracker Upgrade Ps Module before and after Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5–7.5×1034 cm−2s−1. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000–4000 fb−1 of proton-proton collisions at a center-of-mass energy of 13–14 TeV by 2029. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, Pt discrimination capabilities, and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Performance Analysis of Phase 2 Tracker Upgrade PS Module Before and After Irradiation

The Large Hadron Collider will undergo a luminosity upgrade targeting a peak instantaneous luminosity ranging from 5 up to 7.5$\times10^{34}$\,cm$^{-2}$s$^{-1}$. The ambitious goal of the High Luminosity LHC is to achieve a total of 3000--4000\,fb$^{-1}$ of proton-proton collisions at a center-of-mass energy of 14\,TeV. To cope with such challenging environmental conditions, the outer tracker of the CMS experiment will be upgraded using closely spaced silicon sensors (pixels and strips) to provide tracking information at the Level-1 trigger. A PS-Module, composed of both a pixel and a strip sensor, was tested at the Fermilab Test-Beam Facility to evaluate its ability to provide accurate tracking information, particle momentum discrimination capabilities and optimal performance at the irradiation levels expected after being exposed to the harsh conditions of the High Luminosity LHC. The results of the test and the comparison of the module performance before and after irradiation will be presented in this poster.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Glass 3D Printing of Microfluidic Pressure Sensor Interrogated by Fiber-Optic Refractometry

This letter reports a novel fused silica microfluidic device with pressure sensing capability that is fabricated by integrated additive and subtractive manufacturing (IASM) method. The sensor consists of a capillary and a 3D printed glass reservoir, where the reservoir volume change under pressure manifests liquid level deviation inside the capillary, thus realizing the conversion between small pressure change into large liquid level variation. Thanks to the design flexibility of this unique IASM method, the proposed microfluidic device is fabricated with liquid-in-glass thermometer configuration, where the reservoir is sealed following a novel 3D printing assisted glass bonding process. And liquid level is interrogated by a fiber-optic sensor based on multimode interference (MMI) effect. This proposed microfluidic device is attractive for chemical and biomedical sensing because it is flexible in design, and maintains good chemical and mechanical stability, and adjustable sensitivity and range.

42 ENGINEERING↗

IN-LINE CHEMICAL SENSOR DEPLOYMENT IN A TRITIUM PLANT

The Savannah River Tritium Plant (TP) relies on well understood but aging sensor technology for process gas analysis. Though new sensor technologies have been brought to various readiness levels, the TP has been reluctant to install technologies that have not been tested in tritium service. This gap between sensor technology development and incorporating new technologies into practical applications demonstrates fundamental challenges that exist when transitioning from status quo to state-of-the-art in an extreme environment such as a tritium plant. These challenges stem from three root obstacles: 1) The need for a comprehensive assessment of process sensing needs and requirements; 2) The lack of a pick-list of process-compatible sensor technologies; and 3) The need to test technologies in a tritium-contaminated process environment without risking production. At Savannah River, these issues are being addressed in a two phase project. In the first phase, TP sensing requirements were determined by a team of process experts. Meanwhile, Savannah River National Laboratory sensor experts identified candidate technologies and related them to the TP processing requirements. The resulting roadmap links the candidate technologies to actual plant needs. To provide accurate assessments of how a candidate sensor technology would perform in a contaminated process environment, an instrument demonstration station was established within a TP glove box. This station was fabricated to TP process requirements and designed to handle high activity samples. The combination of roadmap and demonstration station provides the following assets: Creates a partnership between the process engineers and researchers for sensor selection, maturation, and insertion, Selects the right sensors for process conditions Provides a means for safely inserting new sensor technology into the process without risking production, and Provides a means to evaluate off normal occurrences where and when they occur. This paper discusses the process to identify and demonstrate new sensor technologies for the Savannah River TP.

07 ISOTOPE AND RADIATION SOURCES↗

Design and construction of the CMS Outer Tracker for the phase-2 upgrade

The High-Luminosity LHC (HL-LHC) is expected to deliver an integrated luminosity of 3000–4000 fb −1 over 10 years of operation with the peak instantaneous luminosity reaching about 5–7.5 × 1 0 34 cm −2 s −1 . During Long Shutdown 3, several components of the CMS detector will undergo major improvements, called Phase-2 upgrades, to be able to operate in the challenging environment of the HL-LHC. The current CMS tracker will be replaced. The Phase-2 Outer Tracker (OT) will have increased radiation tolerance, higher granularity, and the capability to handle higher data rates. Moreover, the OT will provide tracking information to the Level-1 trigger for the first time at a hadron collider, allowing trigger rates to be kept at a sustainable level without sacrificing physics potential. For this, the OT will be made of modules with two closely-spaced silicon sensors read out by front-end ASICs that can correlate hits in the two sensors to create short track segments, used in the Level-1 track finder. The modules come in two flavors: strip-strip and pixel-strip, containing different sensor configurations and multiple ASICs. This contribution presents the Phase-2 OT, the finalization of the OT module design, and the quality assurance and control procedures used to ensure that the modules fulfill both the specifications from the assembly steps as well as the proper communication among the ASICs.

Zoi, Irene [Fermilab] (ORCID:0000000257389446)↗

Tower Water-Vapor Mixing Ratio Value-Added Product Report

The purpose of the Tower Water-Vapor Mixing Ratio (TWRMR) value-added product (VAP) is to calculate water-vapor mixing ratios at the 25-meter and 60-meter levels of the meteorological tower and also report best-estimate temperature, relative humidity, and pressure measurements at the 2-meter, 25-meter, and 60-meter levels at the Atmospheric Radiation Measurement (ARM) user facility Southern Great Plains (SGP) Central Facility. Because there are no barometric pressure sensors at the 25-meter and 60-meter levels on the tower, the hypsometric equation is used along with surface pressure values from the surface meteorological instrumentation (MET), the surface meteorological observation system (SMOS), or the temperature, humidity, wind, and pressure system (THWAPS) to derive barometric pressures at those altitudes (Ritsche 2008, 2011a, 2011b). After this is done, water-vapor mixing ratio can be calculated directly.

54 ENVIRONMENTAL SCIENCES↗

Reflected solar radiance seen by satellite

We derive the integral expression for the reflected solar flux F (W/m 2 ) seen by a sensor deployed on a satellite circling the earth at elevation h t . The sensor’s responsivity is that of a Si photodiode, (0.3, 1.1) µm. We first ignore atmospheric absorption, but account for light emanating from all angles, zenith up to parallel to earth surface. The expression, which holds for all “Solar–Earth–Sensor” (elevation) angles φ e , corrects a long-used equation in the USNDS program, that models “background irradiance,” Ramsey [3], Eq.(2.2). Flux striking the sensor is proportional to the sea-level solar radiance I 0 and the average earth albedo A. Results are displayed for h t = 2.02 · 10 4 km. The integral varies with angle φ e , i.e., F = F(φ e ). When sensor and sun are aligned with earth center, F = F(0) = 0.620 I 0 AR 2 , where R = r e /(r e + h t ) and r e is the average earth radius. For the specified h t , |φ e | < 180 - θ 0 deg, where θ 0 = 13.90. For larger angles, F = 0 since the sensor cannot see any part of earth illuminated by the sun. The flux F(φ e ) decays as ϵ 3.5 when φ e = 180-θ 0 - ϵ and ϵ→ 0, i.e., as the sensor enters darkness. Our ϵ 3.5 result differs from Ramsey’s [3], Eq.(2.2), which has ϵ 4.3 . We conclude Eq.(2.2) is incorrect for two reasons: the erroneous decay and, more importantly, that it vanishes only at φ e = 180. Our result, Eq.(14), presents a simple approximation to F(φ e ), accurate to better than 0.5%. The approximation blends Ramsey’s expression for small φ e with an ϵ 3.5 decay for large angles. Assuming a solar radiance I 0 = 1120, W/m 2 Wikipedia [7], and albedo A = 0.3, NASA, yields F(0) = 3.8 W/m 2 , which is 80% less than the leading term in Ramsey [3], Eq.(2.2). If atmospheric absorption is not ignored our integrand is modified by the factor exp(-τ N atm ), where τ is the atmosphere’s optical depth and N atm accounts for slant path absorption. The result is spectrally dependent. Absorption significantly decreases the flux as φ e → 180 - θ 0 .

79 ASTRONOMY AND ASTROPHYSICS↗

CovS inactivation reduces CovR promoter binding at diverse virulence factor encoding genes in group A Streptococcus

The control of virulence gene regulator (CovR), also called caspsule synthesis regulator (CsrR), is critical to how the major human pathogen group A Streptococcus fine-tunes virulence factor production. CovR phosphorylation (CovR~P) levels are determined by its cognate sensor kinase CovS, and functional abrogating mutations in CovS can occur in invasive GAS isolates leading to hypervirulence. Presently, the mechanism of CovR-DNA binding specificity is unclear, and the impact of CovS inactivation on global CovR binding has not been assessed. Thus, we performed CovR chromatin immunoprecipitation sequencing (ChIP-seq) analysis in the emm1 strain MGAS2221 and its CovS kinase deficient derivative strain 2221-CovS-E281A. We identified that CovR bound in the promoter regions of nearly all virulence factor encoding genes in the CovR regulon. Additionally, direct CovR binding was observed for numerous genes encoding proteins involved in amino acid metabolism, but we found limited direct CovR binding to genes encoding other transcriptional regulators. The consensus sequence AATRANAAAARVABTAAA was present in the promoters of genes directly regulated by CovR, and mutations of highly conserved positions within this motif relieved CovR repression of the hasA and MGAS2221_0187 promoters. Analysis of strain 2221-CovS-E281A revealed that binding of CovR at repressed, but not activated, promoters is highly dependent on CovR~P state. CovR repressed virulence factor encoding genes could be grouped dependent on how CovR~P dependent variation in DNA binding correlated with gene transcript levels. Taken together, the data show that CovR repression of virulence factor encoding genes is primarily direct in nature, involves binding to a newly-identified DNA binding motif, and is relieved by CovS inactivation. These data provide new mechanistic insights into one of the most important bacterial virulence regulators and allow for subsequent focused investigations into how CovR-DNA interaction at directly controlled promoters impacts GAS pathogenesis.

59 BASIC BIOLOGICAL SCIENCES↗

Detecting outliers in streaming time series data from ARM distributed sensors

The Atmospheric Radiation Measurement (ARM) Data Center at ORNL collects data from a number of permanent and mobile facilities around the globe. The data is then ingested to create high level scientific products. High frequency streaming measurements from sensors and radar instruments at ARM sites require high degree of accuracy to enable rigorous study of atmospheric processes. Outliers in collected data are common due to instrument failure or extreme weather events. Thus, it is critical to identify and flag them. We employed multiple univariate, multivariate and time series techniques for outlier detection methods and studied their effectiveness. First, we examined Pearson correlation coefficient which is used to measure the pairwise correlations between variables. Singular Spectrum Analysis (SSA) was applied to detect outliers by removing the anticipated annual and seasonal cycles from the signal to accentuate anomalies. K-means was applied for multivariate examination of data from collection of sensors to identify any deviation from expected and known patterns and identify abnormal observation. The Pearson correlation coefficient, SSA and K-means methods were later combined together in a framework to detect outliers through a range of checks. We applied the developed method to data from meteorological sensors at ARM Southern Great Plains site and validated against existing database of known data quality issues.

Lu, Yuping↗

I&C System Sensors for Advanced Nuclear Reactors

As advanced reactor designers proceed with further research, design implementation, testing, and deployment, it is now time to address their instrumentation and control (I&C) needs. First, we must identify the process variables that must be measured to control an advanced reactor and monitor its safety. As with any nuclear power plant, it is safe to assume that temperature, pressure, flow, level, and neutron flux are the predominant variables to be measured. As a second step, the range of process values must be established as well as the level of accuracy, redundancy, and speed of response of sensors that must be deployed to measure these values. The harsh environments of advanced reactors such as high temperatures, high levels of nuclear radiation, potential for corrosion, and limited access to sensors for maintenance are just a few examples of instrumentation challenges. This is compounded by the relatively small market for new sensors that must be designed, developed, and qualified for advanced reactors. That is, the cost of these activities can deter major sensor manufacturers from entering the advanced reactor market. Furthermore, the operating cycles of most advanced reactors are expected to be much longer than conventional plants adding to the need for instrumentation that can maintain calibration and response time over extended intervals. The fact that there are now a variety of advanced reactors under design and development adds to the complexity of instrumentation that may differ for various types of advanced plants. A few examples of the most commonly discussed advanced reactors are reviewed in this paper followed by a brief discussion of their instrumentation needs.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗