Search NASA⌕ Search

SEARCH · Search NASA

Results for “light element”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Integrated Grating Spectrometer

Proposed integrated grating spectrometer made in waveguide layer on silicon wafer. Occupies area of about 2 centimeters to 2nd power on wafer 0.4 mm thick. Operates in visible spectrum (wavelengths of 400 to 700 nm) and blazed to diffract in first order. Array of integrated grating spectrometers performs spectral analysis of picture elements along line. Optical fiber couples light from each picture element into separate integrated spectrometer. Technique enables continous independent variation, along grating, of pitch, curvature, and blaze angle. Grating designed to have large numerical aperture, zero aberration at two selected wavelengths, and very low aberration at intermediate wavelengths.

Lang, Robert J.↗

Fluid flow meter for measuring the rate of fluid flow in a conduit

A tube fluid flow rate meter consists of a reservoir divided by flexible diaphragm into two separate isolated compartments. The incoming and outgoing tubes open into the compartments. The orifice is sized to allow maximum tube fluid flow. Opposing compression springs are secured within the two compartments on opposite sides of the orifice to maintain orifice position when the tube fluid pressure is zero. A tapered element is centered in, and extends through the orifice into the compartment, leaving an annular opening between the element and the perimeter of the oriface. The size varies as the diaphragm flexes with changes in the tube fluid pressure to change the fluid flow through the opening. The light source directs light upon the element which in turn scatters the light through the opening into the compartment. The light detector in the compartment senses the scattered light to generate a signal indicating the amount of fluid.

White, P. R.↗

Physical correction filter for improving the optical quality of an image

A family of physical correction filters is described. Each filter is designed to correct image content of a photographed scene of limited resolution and includes a first filter element with a pinhole through which light passes to a differential amplifier. A second filter element through which light passes through one or more openings, whose geometric configuration is a function of the cause of the resolution loss included. The light, passing through the second filter element, is also supplied to the differential amplifier whose output is used to activate an optical display or recorder to reproduce a photograph or display of the scene in the original photograph or display of the scene in the original photograph with resolution which is significantly greater than that characterizing the original photograph.

Lee, S. Y.↗

Experimental geochemistry of Pu and Sm and the thermodynamics of trace element partitioning

An experimental study of the partitioning of Pu and Sm between diopside/liquid and whitlockite/liquid supports the hypothesis that Pu behaves as a light rare earth element during igneous processes in reducing environments. D-Pu/D-Sm is found to be about 2 for both diopsidic pyroxene and whitlockite, and the amount of fractionation would be decreased further if Pu were compared to Ce or Nd. Data indicate that temperature, rather than melt composition, is the most important control on elemental partitioning, and that P2O5 in aluminosilicate melts serves as a complexing agent for the actinides and lanthanides.

Jones, John H.↗

Optical flip-flops and sequential logic circuits using a liquid crystal light valve

This paper is concerned with the application of optics to digital computing. A Hughes liquid crystal light valve is used as an active optical element where a weak light beam can control a strong light beam with either a positive or negative gain characteristic. With this device as the central element the ability to produce bistable states from which different types of flip-flop can be implemented is demonstrated. In this paper, some general comments are first presented on digital computing as applied to optics. This is followed by a discussion of optical implementation of various types of flip-flop. These flip-flops are then used in the design of optical equivalents to a few simple sequential circuits such as shift registers and accumulators. As a typical sequential machine, a schematic layout for an optical binary temporal integrator is presented. Finally, a suggested experimental configuration for an optical master-slave flip-flop array is given.

Fatehi, M. T.↗

The R -Process Alliance: Exploring the cosmic scatter among ten r -process sites with stellar abundances

Context. The astrophysical origin of the rapid neutron-capture process (r-process), responsible for producing roughly half of the elements heavier than iron, remains uncertain. Detailed chemical signatures from the oldest, most metal-poor stars, which act as fossil records of the earliest nucleosynthesis events, can be used to identify the dominant r-process sites. Aims. We present a homogeneous chemical abundance analysis of ten r-process element-enhanced stars. These old and metal-poor stars are strongly enriched in r-process elements with minimal contamination from other nucleosynthetic sources. By focusing on this chemically pure sample, we aim to investigate intrinsic variations in the r-process abundance patterns and explore their implications for the nature and potential diversity of r-process sites. Methods. We performed a detailed chemical abundance analysis of high-resolution, high-signal-to-noise spectra. For each star, we inspected over 1400 individual absorption lines using a combination of equivalent width measurements and spectral synthesis. The analysis was conducted under the assumption of 1D local thermodynamic equilibrium and employing the MOOG radiative transfer code. Results. We derived abundances for 54 chemical species, including 29 neutron-capture (n-capture) elements, covering the full mass range of the r-process abundance pattern. A kinematic analysis reveals that stars likely originated from ten kinematically distinct systems. Based on this assumption, we used the sample to probe the maximum variation expected from ten independent r-process nucleosynthesis events and computed the intrinsic dispersion of each element relative to Zr and Eu for the light and heavy r-process elements, respectively. This exercise resulted in a remarkably low cosmic scatter across the ten r-process sites enriching these stars; for the rare earth and third peak elements, for example, we find σ [La/Eu] = 0.08 and σ [Os/Eu] = 0.11 dex, while the scatter between light and heavy elements, σ [Zr/Eu] , is slightly higher at 0.18 dex. Conclusions. The elemental abundance patterns across the ten independent r-process sites show remarkably small cosmic dispersions. This minimal dispersion suggests a high degree of uniformity in r-process yields across diverse astrophysical environments.

Astronomy and AstroPhysics↗

Apparatus and method using a holographic optical element for converting a spectral distribution to image points

A holographic optical element transforms a spectral distribution of light to image points. The element comprises areas, each of which acts as a separate lens to image the light incident in its area to an image point. Each area contains the recorded hologram of a point source object. The image points can be made to lie in a line in the same focal plane so as to align with a linear array detector. A version of the element has been developed that has concentric equal areas to match the circular fringe pattern of a Fabry-Perot interferometer. The element has high transmission efficiency, and when coupled with high quantum efficiency solid state detectors, provides an efficient photon-collecting detection system. The element may be used as part of the detection system in a direct detection Doppler lidar system or multiple field of view lidar system.

McGill, Matthew J.↗

Telescope with a wide field of view internal optical scanner

A telescope with internal scanner utilizing either a single optical wedge scanner or a dual optical wedge scanner and a controller arranged to control a synchronous rotation of the first and/or second optical wedges, the wedges constructed and arranged to scan light redirected by topological surfaces and/or volumetric scatterers. The telescope with internal scanner further incorporates a first converging optical element that receives the redirected light and transmits the redirected light to the scanner, and a second converging optical element within the light path between the first optical element and the scanner arranged to reduce an area of impact on the scanner of the beam collected by the first optical element.

Degnan, III, John James↗

First Astronomical Use Of Multiplexed Transition Edge Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing five orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering delta-lamda/lamda = 1/7 at a resolution of delta-lamda/lamda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve doppler broadened line emission from external galaxies. FIBRE operates in the 350 micrometer and 450 micrometer bands. These bands cover line emission from the important PDR tracers neutral carbon [CI] and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.

Benford, D. J.↗

Broadband Direct Detection Submillimeter Spectrometer with Multiplexed Superconducting Transition Edge Thermometer Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers as direct detectors (i.e., with cold electrons) for spectroscopy. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer for the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda = 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE has been operated in the 350 Am (850 GHz) band. These bands cover line emission from the important star formation tracers neutral carbon [CI] and carbon monoxide (CO).

Benford, D. J.↗

First Astronomical Use of Multiplexed Transition Edge Sensor Bolometers

We present performance results based on the first astronomical use of multiplexed superconducting bolometers. The Fabry-Perot Interferometer Bolometer Research Experiment (FIBRE) is a broadband submillimeter spectrometer that achieved first light in June 2001 at the Caltech Submillimeter Observatory (CSO). FIBRE's detectors are superconducting transition edge sensor (TES) bolometers read out by a SQUID multiplexer. The Fabry-Perot uses a low resolution grating to order sort the incoming light. A linear bolometer array consisting of 16 elements detects this dispersed light, capturing 5 orders simultaneously from one position on the sky. With tuning of the Fabry-Perot over one free spectral range, a spectrum covering Delta lambda/lambda = 1/7 at a resolution of delta lambda/lambda approx. 1/1200 can be acquired. This spectral resolution is sufficient to resolve Doppler-broadened line emission from external galaxies. FIBRE operates in the 350 m and 450 m bands. These bands cover line emission from the important star formation tracers neutral carbon (CI) and carbon monoxide (CO). We have verified that the multiplexed bolometers are photon noise limited even with the low power present in moderate resolution spectrometry.

Staguhn, J. G.↗

Display screen and method of manufacture therefor

A screen assembly that combines an angle re-distributing prescreen with a conventional diffusion screen is disclosed. The prescreen minimizes or eliminates the sensitivity of the screen assembly to projector location. The diffusion screen provides other desirable screen characteristics. The prescreen is preferably formed by a collection of light transmitting and refracting elements, preferably spheres 80, partially embedded in a light blocking layer. Toward the back of the spheres 80 are effective apertures 82 where the light blocking layer 81 is absent or at least thinner than in other regions toward the side of the spheres. The projected image enters spheres 80 through the effective apertures 82, and exits the spheres 80 centered orientationally about the normal to the lens axis. The re-oriented light rays then enter the diffusion screen for viewing.

Dubin, Matthew B.↗

Thermodynamic constraints on the textural evolution of eucrite, EET 90020

Basaltic eucrites, which are possibly parts of the Vestan crust, formed as either lava flows or intrusions, and can offer insights into early crust formation. However most eucrites have experienced thermal metamorphism, which exacerbates the challenges of understanding these samples. A variety of petrogenetic models such as, partial melting of a primitive source, fractional crystallization of magmas emplaced in a primitive crust, and/or partial melting of a eucritic source coupled with melt mixing and assimilation have been proposed in order to explain observed petrologic and chemical characteristics of eucrites. EET 90020 is an unbrecciated eucrite that has experienced significant thermal metamorphism, with temperatures of metamorphic equilibration calculated to be ~840-1040°C. Its petrologic history remains contentious, in part due to differences in trace element analyses [10,17, this work], which has led to multiple metamorphic interpretations [8,10-11]. Here, we combined petrologic observations, chemical analyses, and thermodynamic modeling, to interpret micro-domain textures identified in EET 90020 and better constrain its petrologic history. Ultimately, the development of such textures is a direct result of the geologic processes operating on a young Vesta or similar asteroid. Sample description: We identified three textural domains in EET 90020 (Figure 1); (I) A coarse grain domain with granoblastic plagioclase and pyroxene, (II) a medium grain domain with curved grain boundaries between plagioclase and pyroxene, and (III) a fine grain domain dominated by tridymite that fills in interstitial space between spherical plagioclase. Major element chemistry in phases is consistent across domains. Pyroxene have distinctive high Ca lamellae (Wo40.92En28.1Fs31.0) forming from the low-Ca pigeonite host (Wo3.5En33.7Fs62.8). There are small amounts of fayalitic olivine along pyroxene/oxide grain boundaries, where pyroxenes have reacted with ilmenite/chromite clasts. Plagioclase is anorthitic (Avg ~An88), with little variation (An86-92.5). Trace element bulk rock analyses were collected via ICP-MS and individual mineral analyses with LA-ICP-MS (Figure 2). The bulk sample has an observable enrichment in light rare earth elements, with a notable depletion in Eu. Plagioclase is enriched in LREEs, depleted in HREEs, and has a positive Eu anomaly while pyroxene is enriched in HREEs with a negative Eu anomaly. Variations in trace element analyses is likely influenced by the presence of phosphates because are highly enriched in REEs and have a dramatic effect on the bulk domain compositions. Thermodynamic modeling: The software package, Perple_X, was used to calculate mineral phase equilibria over a range of conditions using a Gibbs free energy minimization approach [12]. Models used all major/minor elements except P2O5. Thermodynamic properties from [13] were used to constrain endmember phase stabilities. Activity models were used to describe mixing in phases with solid solution. Isochemical P-T phase diagrams were constructed for the bulk thin section, and the coarse, medium and fine grain domain compositions. Domain compositions were determined using microprobe analyses of phases identified in each domain and observed modal mineral abundancies. Thermodynamically stable pyroxene compositions were extracted from model results and compared to pyroxene compositions collected via EMPA, allowing us to calculate temperatures for metamorphic equilibrium. Results: Results that use the coarse domain composition (Fig. 3a) demonstrate overlap at T ~ 1020°C indicating high T equilibration. There was no overlap for the medium and fine grain domains, or the bulk composition (e.g., Fig. 3b) indicating that these are not equilibrium assemblages. These results were replicated using data from [8,20]. Discussion: The disequilibrium results from the bulk rock, fine grain and medium grain models imply that EET 90020 was modified during and/or after peak metamorphism (open system behavior). However, this is in contrast to the coarse domain where it appears as if equilibrium was maintained. We suggest that this conflict is explained by highly localized equilibrium occurring at millimeter length-scales, which has been observed in terrestrial metamorphism where aqueous fluid infiltrate [14] or melt loss occurs [15]. It is unlikely that aqueous alteration was significant in modifying the bulk composition of EET 90020, because it lacks hydrated minerals. However, the presence of melt is supported by the presence of an abundance of curved grain boundaries and spherical grains in the medium and fine grain domains This contrasts the coarse domain, where grain boundaries are angular. Given the evidence for disequilibrium in the medium and fine grain domains, it would be inappropriate to draw additional conclusions about textural evolution using thermodynamic models of those domains. However, modeling results of the coarse grain domain, where equilibrium was maintained, can provide useful insights into the geologic evolution of EET 90020. We approximate maximum metamorphic temperatures, using the Ca component in pyroxene, at ~1020°C (Fig. 4), which is consistent with previous two-pyroxene thermometry [11]. At this temperature, up to 10 vol % melt can be produced in the coarse grain domain, which is at the boundary of minimum melt needed in order to segregate and form a melt network [16]. Tridymite and plagioclase would be the first minerals to melt out during heating starting ~990°C. This is consistent with the observed melt textures formed by tridymite and plagioclase in the fine grain domain. We suggest that a partial melting model best explains the textural development of EET 90020. Upon heating, melt generated was either trapped, resulting in no net change in the localized rock composition, or migrated, resulting in disequilibrium between pyroxene and the surrounding matrix. A positive Eu anomaly in plagioclase indicates that all of the plagioclase was melted previously. This is consistent with previous studies that have suggested that EET 90020 represents a residual eucrite that experienced partial melting and subsequent melt loss [8]. We speculate that partial melting could have occurred when EET 90020 was heated in the asteroid’s lower crust or adjacent to an intrusion [7]. Future work will study other, texturally heterogeneous samples to see if EET 90020 presents a unique circumstance or whether crustal partial melting was ubiquitous on the eucrite asteroid.

Eucrites↗

An Optical Oxygen Sensor for Long-Term Continuous Monitoring of Dissolved Oxygen in Perfused Bioreactors

For long-term growth of man1ITlalian cells in perfused bioreactors, it is essential to monitor the concentration of dissolved oxygen (DO) present in the culture medium to quantitate and control level of DO. Continuous measurement of the amount of DO in the cell culture medium in-line under sterile conditions in NASA's perfused bioreactor requires that the oxygen sensor provide increased sensitivity and be sterilizable and nontoxic. Additionally, long-term cell culture experiments require that the calibration be maintained several weeks or months. Although there are a number of sensors for dissolved oxygen on the market and under development elsewhere, very few meet these stringent conditions. An optical oxygen sensor (BOXY) based on dynamic fluorescent quenching and a pulsed blue LED light source was developed in our laboratory to address these requirements. Tris( 4,7 -diphenyl-l, 1 O-phenanthroline )ruthenium(II) chloride is employed as the fluorescent dye indicator. The sensing element consists of a glass capillary (OD 4.0 mm; ID 2.0 mm) coated internally with a thin layer of the fluorescent dye in silicone matrix and overlayed with a black shielding layer. Irradiation of the sensing element with blue light (blue LED with emission maximum at 475 nm) generates a red fluorescence centered at 626 nm. The fluorescence intensity is correlated to the concentration of DO present in the culture medium, following the modified non-linear Stern-Volmer equation. By using a pulsed irradiating light source, the problem of dye-bleaching, which is often encountered in long-term continuous measurements of tIns type, 'is minimized. To date we achieved sensor resolution of 0.3 mmHg at 50 mmHg p02, and 0.6 mmHg at 100 mmHg p02, with a response time of about one minute. Calibration was accomplished in sterile phosphate-buffered saline with a blood-gas analyzer (BGA) measurement as reference. Stand-alone software was also developed to control the sensor and bioreactor as well as to acquire data. Two HOXY sensors with a single calibration were employed to continuously monitor the DO in GTSF-2 medium during a Baby Hamster Kidney (BHK-21) cell culture in a Rotating Wall Perfused Vessel (RWPV) bioreactor for 90 days. HOXY sensors were located at the inlet to and outlet from the bioreactor. One of the sensors was placed between an oxygenator and the inlet to the bioreactor. The dissolved oxygen concentrations determined by both sensors were compared with those measured regularly with the BGA reference. The cell culture was maintained for 110 days. Sensor output was found to correlate well with the BGA data throughout the experiment, where the DO of the medium ranged between 25 and 50 mmHg at the bioreactor outlet and 90-130 mmHg at the bioreactor inlet. Measuring DO with the HOXY sensors versus the BGA reference indicated bias values of -2 mmHg and -15 mmHg, and precision values of +/-3mmHg and +/-16 mmHg at the bioreactor inlet and outlet, respectively.

Gao, F. G.↗

Rare earth element abundances in rocks and minerals from the Fiskenaesset Complex, West Greenland

The paper reports activation-analysis determinations of rare-earth-element (REE) and other trace-element concentrations in selected rocks, plagioclase, and mafic separates from the Fiskenaesset Complex. The REE abundances are found to be very low and atypical in comparison with other terrestrial anorthosites. The plagioclases are shown to be characterized by a deficiency in heavy RE elements relative to light ones and a positive Eu anomaly, while the mafic separates are enriched in heavy rare earths and have no Eu anomaly, except in one sample. It is found that the bulk and trace-element abundances of the plagioclases are similar to those observed in some lunar anorthosites, but the degree of Eu anomaly is less in the plagioclases. The data are taken as confirmation of the idea that fractionation processes were involved in the origin of the Complex, and it is concluded that the Complex may have been produced from a magma generated by partial melting of a garnet-bearing source.

Henderson, P.↗

Sub miniaturized laser doppler velocimeter sensor

A miniaturized laser Doppler velocimeter is formed in a housing that is preferably 3 mm in diameter or less. A laser couples light to a first diffractive optical element that is formed on the fiber end. The light is coupled to a lens that also includes a diffractive optical element. The same lens is also used to collect receive light, and receives includes another diffractive optical element to collect that received light.

Gharib, Morteza↗

Isotopic investigations in the area of the Tunguska catastrophe in 1908 year

The hypotheses of the annihilation and thermonuclear character of the Tunguska explosion have been tested by measuring inductive Ar-39 radioactivity from K and Ca in rocks and soil under the explosion epicentrum. Ar-39 was not detected though its estimated radioactivity was expected to be 100 times higher than the radio-metrical plant sensitivity. These results testify against the nuclear nature of the Tunguska explosion. The contents of 11 elements in the ultrasmall quantity of matter of the silicate microspherules isolated from catastrophe peat layer at the explosion site were measured by method of neutron activation analysis. It was demonstrated that the enrichment of microspherules by light and volatile elements (Al, Na, Zn, Cs) and the impoverishment by more heavy and hard volatile ones (Fe, Co, Sc). It was shown that the microspherules were not the product of differentiation of the terrestrial soil or of an ordinary meteorite material. It was demonstrated that Pb isotopic content in catastrophe peat layer had more Pb-204, Pb-207, Pb-208 than Pb-206 as compared with Pb isotopic content of other peat layers and common Pb in this area. In the peat column taken at the Ostraya hill area in three nearcatastrophe layers, small increases of isotopic C-13 was determined. Isotopic C effect in the peat layer is confirmed also for the North peatbog. Observed isotopic changes are not accounted for by climatic changes or other physico-chemical reasons. They seem to be related to preservation in the peat of matter resembling carbonaceous chrondrites of the Cl type or more probably of cometary matter enriched much more in volatile elements.

Kolesnikov, E. M.↗

The interstellar abundances of tin and four other heavy elements

Spectra recorded at 1150-1600 A with an instrumental resolution near 16 km/s were obtained with the Goddard High-Resolution Spectrograph on board the HST. The gaseous interstellar abundances of five heavy elements along the light paths to 23 Ori, 15 Mon, 1 Sco, Pi Sco, and Pi Aqr were determined from the observations. The 1400.450 A line of Sn II was detected and identified toward three stars; at Z = 50, tin is the first element from the fifth row of the periodic table to be identified in the interstellar medium. One spectral line of each of Cu II (Z = 29) and Ga II (Z = 31), three lines of Ge II (Z = 32), and two lines of Kr I (Z = 36) were also detected toward some or all of the five stars. The depletions of these five heavy elements generally decrease monotonically with increasing atomic number toward each of the six stars, and tin is generally undepleted within the observational errors. The depletions of 26 elements from the interstellar gas in an average dense interstellar cloud appear to correlate with the elemental 'nebular' condensation temperatures more closely than with the first ionization potentials.

Hobbs, L. M.↗