Repairable and Reconfigurable Structured Liquid Circuits

The advance of printed electronics is significantly bolstered by the development of liquid-state electronics that overcome the inherent limitations in flexibility and reconfigurability of solid-state electronics. By integrating the biocompatibility and conductivity of sulfonated polyaniline (S-PANI) and phytic acid (PA) with the reconfigurability of structured liquids, highly conductive all-liquid threads are developed. The dense packing and overlap of PA/S-PANI complexes at an oil/water interface promotes in-plane electron transport, and standard four-point probe measurements of PA/S-PANI interfacial assemblies demonstrate enhanced electrical properties. Notably, the rapid jetting of the ink phase into the matrix phase allows for liquid threads to be printed, enabling the fabrication of large-scale, conductive pathways between two electrodes and liquid circuits. Upon mechanical cleavage of the liquid wires, circuits can be broken, but will easily self-repair using an electric field, making this motif useful in the design of switches as well as restoring conductive pathways in series or in parallel. In conclusion, the demonstrated flexibility and reconfigurability these PA/S-PANI wires possess hold significant promise for their practical use in the design of flexible and adaptive bioelectronics that can be repaired on demand, signifying a transformative step in the evolution of liquid electronic materials.

36 MATERIALS SCIENCE↗

Electrochemical recovery of Gd into liquid Bi in molten LiCl-KCl-GdCl 3

The electrochemical recovery of Gd into liquid Bi electrodes was investigated in molten LiCl-KCl-GdCl 3 electrolyte at 773–973 K using constant currents of 10–150 mA cm −2 . High round-trip coulombic efficiency (>97 %) was demonstrated for deposition and removal of Gd into and from liquid Bi at all temperatures, confirming chemically reversible electrode reactions towards high recovery yield of Gd using liquid Bi. Furthermore, the overpotential associated with deposition of Gd into the liquid Bi electrode gradually increased with current density and decreased with temperature. At the lowest temperature of 773 K, a steep increase in overpotential was evident at high current densities due to slower mass transport and low solubility of Gd in liquid Bi (0.5 at.% Gd). Based on the impedance spectra of Bi electrodes at 773–973 K, the exchange current density was estimated to be 110–220 mA cm −2 , indicating facile charge transfer at the liquid electrode-electrolyte interface. Post-mortem characterization of Bi cathodes after electrolysis at 873 K indicated the formation of a solid GdBi(s) compound layer at the Bi electrode surface. Chemical analysis of Bi cathodes at various deposited Gd compositions resulted in Faradaic efficiencies of ∼75–84 %, promising a high recovery yield of Gd from molten salts using a strongly-interacting liquid Bi electrode.

36 - MATERIALS SCIENCE↗

Liquid Water Cloud Measurements Using the Raman Lidar Technique: Current Understanding and Future Research Needs

This paper describes recent work in the Raman lidar liquid water cloud measurement technique. The range-resolved spectral measurements at the National Aeronautics and Space Administration Goddard Space Flight Center indicate that the Raman backscattering spectra measured in and below low clouds agree well with theoretical spectra for vapor and liquid water. The calibration coefficients of the liquid water measurement for the Raman lidar at the Atmospheric Radiation Measurement Program Southern Great Plains site of the U.S. Department of Energy were determined by comparison with the liquid water path (LWP) obtained with Atmospheric Emitted Radiance Interferometer (AERI) and the liquid water content (LWC) obtained with the millimeter wavelength cloud radar and water vapor radiometer (MMCR-WVR) together. These comparisons were used to estimate the Raman liquid water cross-sectional value. The results indicate a bias consistent with an effective liquid water Raman cross-sectional value that is 28%-46% lower than published, which may be explained by the fact that the difference in the detectors' sensitivity has not been accounted for. The LWP of a thin altostratus cloud showed good qualitative agreement between lidar retrievals and AERI. However, the overall ensemble of comparisons of LWP showed considerable scatter, possibly because of the different fields of view of the instruments, the 350-m distance between the instruments, and the horizontal inhomogeneity of the clouds. The LWC profiles for a thick stratus cloud showed agreement between lidar retrievals andMMCR-WVR between the cloud base and 150m above that where the optical depth was less than 3. Areas requiring further research in this technique are discussed.

vapor and liquid water↗

Unusual dynamics of tetrahedral liquids caused by the competition between dynamic heterogeneity and structural heterogeneity

Tetrahedral liquids exhibit intriguing thermodynamic and transport properties because of the various ways tetrahedra can be packed and connected. Recently, an unusual temperature dependence of the stretching exponent β in a model tetrahedral liquid ZnCl 2 from T m + 85 K to T m + 35 K has been reported using neutron-spin echo spectroscopy. This discovery stands in sharp contrast to other glass-forming liquids. In this study, we conducted neural network force field driven molecular dynamic simulations of ZnCl 2 . We found a non-monotonic temperature dependence of β from liquid to supercooled liquid temperatures. Further structural decomposition and dynamic analysis suggest that this unusual dynamic behavior is a result of the competition between the decrease in the diversity of tetrahedra motifs (structural heterogeneity) and the increase in glassy dynamic heterogeneity. Furthermore, this result may contribute to new understandings of the structural relaxation of other network liquids.

36 MATERIALS SCIENCE↗

Dehumidification energy storage using a stratified liquid desiccant tank

Liquid desiccants can play an important role in reducing dehumidification energy requirements in the built environment. Because they are in a liquid state, the desiccant can be easily stored and then used to dehumidify buildings during peak energy consumption periods. By maintaining stratification between concentrated and diluted desiccant solutions, a single tank can be used to store liquid desiccant for energy storage purposes. Using a stratified tank instead of separate tanks for dilute and concentrated solutions will reduce storage costs and increase energy storage densities for liquid desiccant systems. This paper describes the experimental validation and one-dimensional modeling of a stratified liquid desiccant tank. The stratified tank prototype developed achieved 80 % of the theoretical energy storage density based on an imposed desiccant concentration change. Here, the stratified tank model was able to reasonably reproduce the experimental results. Using this model, the impact of varying operational conditions on the energy density of the stratified liquid desiccant energy storage was evaluated. Depending on the operating conditions, stratified liquid desiccant energy storage using aqueous LiCl up to 40 wt% can achieve energy storage densities in excess of 330 kWh/m 3 .

25 ENERGY STORAGE↗

Identifying High Ionic Conductivity Compositions of Ionic Liquid Electrolytes Using Features of the Solvation Environment

Binary mixtures of ionic liquids with molecular solvents are gaining interest in electrochemical applications due to the improvement in their performance over neat ionic liquids. Dilution with suitable molecular solvents can reduce the viscosity and facilitate faster diffusion of ions, thereby yielding substantially higher ionic conductivity than that for a pure ionic liquid. Although viscosity and diffusion coefficients typically behave as monotonic functions of concentration, ionic conductivity often passes through a peak value at an optimum molar ratio of the molecular solvent to the ionic liquid. The ionic conductivity maximum is generally explained in terms of a balance between the ease of charge transport and the concentration of the charge carriers. In this work, fluctuation in the local environment surrounding an ion is invoked as a plausible explanation for the ionic conductivity mechanism with a binary mixture of 1-ethyl-3-methylimidazolium tetrafluoroborate and ethylene glycol as an example. The magnitude of the dynamism in the local environment is captured by measuring the spatial and temporal features of the solvation environment. Standard deviation in the number of ions in the solvation environment serves as a spatial feature, while the cage correlation lifetimes for oppositely charged ions within the first solvation shell serve as a temporal feature. Large standard deviations in the cluster ion population and short cage correlation lifetimes are indicators of highly dynamic ionic environment at the molecular level and consequently yield high ionic conductivity. Such compositions were found to be in good agreement with the optimum ionic liquid mole fractions obtained through experimental measurement. Short cage correlation lifetimes enable the identification of optimum mixture compositions using simulation trajectories significantly shorter than those required to implement the Nernst–Einstein or Einstein formalisms for calculating ionic conductivity. We validated the applicability of this approach across force fields and in six ionic liquid-molecular solvent electrolytes formed with combination of cations, anions, and solvents. We offer a computationally efficient approach of screening ionic liquid-molecular solvent binary mixture electrolytes to identify molar ratios that yield high ionic conductivity.

25 ENERGY STORAGE↗

A SURVEY OF MASS AND LEVEL GAUGING TECHNIQUES FOR LIQUID HYDROGEN

Generally, liquid level sensors are used to determine the liquid mass or head in tank filling, holding, and propellant utilization systems for rocket vehicles, and also In storage Inventory and research applications. The latter two applications are so varied that they will not be discussed further. Tank filling and holding to a predetermined liquid mass require a flow control system that is maintained by a liquid level sensor. The sensor may be a continuous-reading type or a rake of point sensors located in the vicinity of the required level Propellant utilization systems control the relative flows of the liquid propellants so that, ideally, no propellant is left over at burnout. A liquid level sensing and control system monitors the liquid mass in each tank during outflow and corrects the relative propellant flows to obtain the desired result. The level sensor again may be either a continuous sensor or a rake of point sensors.

LIQUID HYDROGEN↗

(abstract) Production and Levitation of Free Drops of Liquid Helium

We are interested in the nucleation and behavior of quantized vorticies and surface excitations in free drops of superfluid helium. We have constructed an apparatus to maintain liquid helium drops isolated from any material container in the Earth's gravitational field, and have investigated two techniques for generating and introducing liquid drops into the region of confinement. The levitation apparatus utilizes the electrostatic force acting upon a charged liquid drop to counteract the gravitational force, with drop position stability provided by a static magnetic field acting upon the helium diamagnetic moment. Electrically neutral superfluid drops have been produced with a miniature thermomechanical pump; for a given configuration the liquid initial velocity has been varied up to several centimeters per second. Liquid drops carrying either net positive or negative charge are produced by an electrode which generates a flow of ionized liquid from the bulk liquid surface. Potentials of less than one thousand volts to several thousand volts are required. The mass flow is controlled by varying duration of the ionizing voltage pulse; drops as small as 30 micrometers diameter, charged to near the Rayleigh limit, have been observed.

quantized vorticity levitation liquid helium↗

Liquid Acquisition Device Hydrogen Outflow Testing on the Cryogenic Propellant Storage and Transfer Engineering Design Unit

As part of the NASA Cryogenic Propellant Storage and Transfer (CPST) Engineering Design Unit (EDU) testing with liquid hydrogen, screen-channel liquid acquisition devices (LADs) were tested during liquid hydrogen outflow from the EDU tank. A stainless steel screen mesh (325x2300 Dutch T will weave) was welded to a rectangular cross-section channel to form the basic LAD channel. Three LAD channels were tested, each having unique variations in the basic design. The LADs fed a common outflow sump at the aft end of the 151 cu. ft. volume aluminum tank, and included a curved section along the aft end and a straight section along the barrel section of the tank. Wet-dry sensors were mounted inside the LAD channels to detect when vapor was ingested into the LADs during outflow. The use of warm helium pressurant during liquid hydrogen outflow, supplied through a diffuser at the top of the tank, always led to early breakdown of the liquid column. When the tank was pressurized through an aft diffuser, resulting in cold helium in the ullage, LAD column hold-times as long as 60 minutes were achieved, which was the longest duration tested. The highest liquid column height at breakdown was 58 cm, which is 23 less than the isothermal bubble-point model value of 75 cm. This paper discusses details of the design, construction, operation and analysis of LAD test data from the CPST EDU liquid hydrogen test.

Liquid hydrogen↗

Performance of a dynamic single bubbler in single and two-phase immiscible liquids

Ensuring nonproliferation and safeguards of special nuclear materials (SNM) is a critical aspect of advancing the nuclear fuel cycle. Traditional bubbler systems used to estimate liquid levels and densities in nuclear recycling processes have limitations, particularly in harsh environments where dip-tube corrosion and buildup necessitate frequent maintenance and recalibration. This study explores the Dynamic Single Bubbler (DSB) method, which utilizes a single dip-tube attached to a linear actuator to estimate liquid properties dynamically. This approach is extended to estimate liquid-liquid interfaces in immiscible liquids and employs a linear regression method to reduce uncertainties and improve accuracy. The DSB method achieved density estimate uncertainties of less than 0.5% and surface level estimate uncertainties typically under 0.5%, across various fluids including water, acetone, methanol, mineral oil, glycerol, and aqueous salt solutions. Results indicate that the DSB method provides accurate and robust estimates of liquid density and surface levels with minimal maintenance and without the need for calibration. Additionally, the method's applicability to immiscible liquids and various dip-tube geometries was demonstrated, showing promise for widespread use in nuclear and other industrial applications.

98 - NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL↗

Liquid transfer demonstration on board Apollo 14 during transearth coast

The transfer of liquid from one container to another in a weightless environment was demonstrated by the crew of Apollo 14. A scale-model liquid-transfer system was used on board the spacecraft during the transearth coast period. The liquid transfer unit consisted of a surface tension baffled tank system containing two baffle designs. Liquid was transferred between tanks with a hand pump operated by the astronaut. The results showed that liquid was efficiently transferred to and from either baffled tank to within two percent of the design value residual liquid without reaching gas ingestion. The liquid-vapor interface in the receiver tank was positioned successfully with the gas located at the vent.

Abdalla, K. L.↗

High-pressure liquid-monopropellant strand combustion.

Examination of the influence of dissolved gases on the state of the liquid surface during high-pressure liquid-monopropellant combustion through the use of a strand burning experiment. Liquid surface temperatures were measured, using fine-wire thermocouples, during the strand combustion of ethyl nitrate, normal propyl nitrate, and propylene glycol dinitrate at pressures up to 81 atm. These measurements were compared with the predictions of a variable-property gas-phase analysis assuming an infinite activation energy for the decomposition reaction. The state of the liquid surface was estimated using a conventional low-pressure phase equilibrium model, as well as a high-pressure version that considered the presence of dissolved combustion-product gases in the liquid phase. The high-pressure model was found to give a superior prediction of measured liquid surface temperatures. Computed total pressures required for the surface to reach its critical mixing point during strand combustion were found to be in the range from 2.15 to 4.62 times the critical pressure of the pure propellant. Computed dissolved gas concentrations at the liquid surface were in the range from 35 to 50% near the critical combustion condition.

Faeth, G. M.↗

Liquid jet pumped by rising gas bubbles

From observations of a stream of gas bubbles rising through a liquid, a two-phase mathematical model is proposed for calculating the induced turbulent vertical liquid flow. The bubbles provide a large buoyancy force and the associated drag on the liquid moves the liquid upward. The liquid pumped upward consists of the bubble wakes and the liquid brought into the jet region by turbulent entrainment. The expansion of the gas bubbles as they arise through the liquid is taken into account. The continuity and momentum equations are solved numerically for an axisymmetric air jet submerged in water. Water pumping rates are obtained as a function of air flow rate and depth of submergence. Comparisons are made with limited experimental information in the literature.

Hussain, N. A.↗

Process for preparing liquid metal electrical contact device

The parts of an electrical contact device are treated by sputter etching to remove the parent metal oxide. Prior to exposure of the electrodes to any oxygen, a sacrificial metal is sputter deposited on the parts. Preferably this sacrificial metal is one that oxidizes slowly and is readily dissolved by the liquid metal. The sacrificial metal may then be removed from unwanted areas. The remainder of the ring and the probe to be wet by the liquid metal are submerged in the liquid metal or the liquid metal is flushed over these areas, preferably while they are being slightly abraded, unitl all the sacrificial material on these portions is wet by the liquid metal. In doing so the liquid metal dissolves the sacrificial metal and permanently wets the parent metal. Preferred materials used in the process and for the electrodes of electrical contact devices are high purity (99.0%) nickel or AISI type 304 stainless steel for the electrical contact devices, gallium as the liquid metal, and gold as the sacrificial material.

Lovell, R. R.↗

The LASL program in nuclear pumped liquid lasers

The development of nuclear-pumped, liquid-based lanthanide ion lasers is discussed. Early investigations of lanthanide ion lasers have lead to solid-state and gaseous neodymium lasers, and a demonstration of lasing in the liquid state. Solvents containing organic chelating agents have been employed in liquid Eu(+3) and Tb(+3) lasers to extend fluorescence lifetimes, however aprotic solvents have been found to enable the development of large-scale liquid lasers. The advantages to be gained from high-power nuclear-pumped lasers based on lanthanide solutions include the high density of fissile materials possible, and a nuclear pumping cell which can operate in either a nuclear or optical pumping mode is being fabricated at the Los Alamos Scientific Laboratory to investigate the nuclear pumping of liquid lanthanide ion lasers. Areas that need exploration before specific laser design features can be considered include energy channeling within the liquid upon excitation, radiation damage due to solvent dissociation, and reactor technology for the development of a self-critical liquid reactor.

Mansfield, C. R.↗

Research on solar pumped liquid lasers

A solar pumped liquid laser that can be scaled up to high power (10Mw CW) for space applications was developed. Liquid lasers have the inherent advantage over gases in that they provide much higher lasant densities and thus high power densities. Liquids also have inherent advantages over solids in that they have much higher damage thresholds and are much cheaper to produce for large scale applications. Among the liquid laser media that are potential candidates for solar pumping, the POC13:Nd(3+):ZrC14 liquid was chosen for its high intrinsic efficiency as well as its relatively good stability against decomposition due to protic contamination. The development and testing of the laser liquid and the development of a large solar concentrator to pump the laser was emphasized. The procedure to manufacture the laser liquid must include diagnostic tests of the solvent purity (from protic contamination) at various stages in the production process.

Schneider, R. T.↗

Vortex motion phase separator for zero gravity liquid transfer

A vortex motion phase separator is disclosed for transferring a liquid in a zero gravity environment while at the same time separating the liquid from vapors found within either the sender or the receiving tanks. The separator comprises a rigid sender tank having a circular cross-section and rigid receiver tank having a circular cross-section. A plurality of ducts connects the sender tank and the receiver tank. Disposed within the ducts connecting the receiver tank and the sender tank is a pump and a plurality of valves. The pump is powered by an electric motor and is adapted to draw either the liquid or a mixture of the liquid and the vapor from the sender tank. Initially, the mixture drawn from the sender tank is directed through a portion of the ductwork and back into the sender tank at a tangent to the inside surface of the sender tank, thereby creating a swirling vortex of the mixture within the sender tank. As the pumping action increases, the speed of the swirling action within the sender tank increases creating an increase in the centrifugal force operating on the mixture. The effect of the centrifugal force is to cause the heavier liquid to migrate to the inside surface of the sender tank and to separate from the vapor. When this separation reaches a predetermined degree, control means is activated to direct the liquid conveyed by the pump directly into the receiver tank. At the same time, the vapor within the receiver tank is directed from the receiver tank back into the sender tank. This flow continues until substantially all of the liquid is transferred from the sender tank to the receiver tank.

Howard, Frank S.↗

Separation Of Liquid And Gas In Zero Gravity

Pair of reports describe scheme for separating liquid from gas so liquid could be pumped. Designed to operate in absence of gravitation. Jet of liquid, gas, or liquid/gas mixture fed circumferentially into cylindrical tank filled with liquid/gas mixture. Jet starts liquid swirling. Swirling motion centrifugally separates liquid from gas. Liquid then pumped from tank at point approximately diametrically opposite point of injection of jet. Vortex phase separator replaces such devices as bladders and screens. Requires no components inside tank. Pumps for gas and liquid outside tank and easily accessible for maintenance and repairs.