Search NASA⌕ Search

SEARCH · Search NASA

Results for “load frequency control”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Field testing of linear individual pitch control on the two-bladed controls advanced research turbine

This paper presents the results of field tests using linear individual pitch control (LIPC) on the two-bladed Controls Advanced Research Turbine 2 (CART2) at the National Renewable Energy Laboratory (NREL). LIPC has recently been introduced as an alternative to the conventional individual pitch control (IPC) strategy for two-bladed wind turbines. The main advantage of LIPC over conventional IPC is that it requires, at most, only two feedback loops to potentially reduce the periodic blade loads. In previous work, LIPC was designed to implement blade pitch angles at a fixed frequency (e.g., the once-per-revolution (1P) frequency), which made it only applicable in above-rated wind turbine operating conditions. In this study, LIPC is extended to below-rated operating conditions by gain scheduling the controller on the rotor speed. With this extension, LIPC and conventional IPC are successfully applied to the NREL CART2 wind turbine. Lastly, the field-test results obtained during the measurement campaign indicate that LIPC significantly reduces the wind turbine loads for both below-rated and above-rated operation.

17 WIND ENERGY↗

Characterizing patterns and variability of building electric load profiles in time and frequency domains

The rapid development of advanced metering infrastructure provides a new data source—building electrical load profiles with high temporal resolution. Electric load profile characterization can generate useful information to enhance building energy modeling and provide metrics to represent patterns and variability of load profiles. Such characterizations can be used to identify changes to building electricity demand due to operations or faulty equipment and controls. In this study, we proposed a two-path approach to analyze high temporal resolution building electrical load profiles: (1) time-domain analysis and (2) frequency-domain analysis. Furthermore, the commonly adopted time-domain analysis can extract and quantify the distribution of key parameters characterizing load shape such as peak-base load ratio and morning rise time, while a frequency-domain analysis can identify major periodic fluctuations and quantify load variability. We implemented and evaluated both paths using whole-year 15-minute interval smart meter data of 188 commercial office building in Northern California. The results from these two paths are consistent with each other and complementary to represent full dynamics of load profiles. The time- and frequency-domain analyses can be used to enhance building energy modeling by: (1) providing more realistic assumptions about building operation schedules, and (2) validating the simulated electric load profiles using the developed variability metrics against the real building load data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Control-augmented structural synthesis

A control-augmented structural synthesis methodology is presented in which the structural member sizes and active control system feedback gains are treated simultaneously as independent design variables. Multiple static and harmonic dynamic loading conditions are considered. Constraints are imposed on static displacements, natural frequencies, and the magnitudes of the steady-state dynamic displacements and actuator forces to ensure acceptable system behavior. Side constraints imposed on the design variables protect against the generation of unrealizable designs. Example problems are presented that demonstrate the method and underscore the importance of integrating the structural and active control system design process.

Lust, R. V.↗

Enhancing SRF cavity stability and minimizing detuning with data-driven resonance control based on dynamic mode decomposition

Effective resonance control of superconducting radio frequency (SRF) cavities is critical for large machines like LCLS-II, as failure to achieve proper control can result in increased RF power consumption, higher cryogenic heat loads, and increased costs. To address this challenge, we have developed a machine learning (ML) model based on the dynamic mode decomposition method to represent the forced cavity dynamics. Using this model, we designed a model predictive controller (MPC) and demonstrated through simulation that the MPC can effectively stabilize the amplitude and phase of SRF cavities using only a frequency actuator, even in the presence of multiple mechanical modes. The lightweight and explicit ML model makes the controller suitable for direct implementation on field-programmable gate arrays, unlocking the full potential of SRF linacs like LCLS-II, enabling higher beam power and energy, and also serving as an advanced motion controller for various applications, such as photon beamlines and storage rings.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Wing/store flutter with nonlinear pylon stiffness

Recent wind tunnel tests and analytical studies show that a store mounted on a pylon with soft pitch stiffness provides substantial increase in flutter speed of fighter aircraft and reduces dependency of flutter on mass and inertia of the store. This concept, termed the decoupler pylon, utilizes a low frequency control system to maintain pitch alignment of the store during maneuvers and changing flight conditions. Under rapidly changing transient loads, however, the alignment control system may allow the store to momentarily bottom against a relatively stiff backup structure in which case the pylon stiffness acts as a hardening nonlinear spring. Such structural nonlinearities are known to affect not only the flutter speed but also the basic behavior of the instability. The influence of pylon stiffness nonlinearities or the flutter characteristics of wing mounted external stores is examined.

Desmarais, R. N.↗

Wing/store flutter with nonlinear pylon stiffness

Recent wind tunnel tests and analytical studies show that a store mounted on a pylon with 'soft' pitch stiffness provides substantial increase in flutter speed of fighter aircraft and reduces dependency of flutter on mass and inertia of the store. This concept, termed the decoupler pylon, utilizes a low-frequency control system to maintain pitch alignment of the store during maneuvers and changing flight conditions. Under rapidly changing transient loads, however, the alignment control system may allow the store to momentarily bottom against a relatively stiff backup structure in which case the pylon stiffness acts as a hardening nonlinear spring. Such structural nonlinearities are known to affect not only the flutter speed but also the basic behavior of the instability. This paper examines the influence of pylon stiffness nonlinearities on the flutter characteristics of wing-mounted external stores.

Desmarais, R. N.↗

NASA rotor systems research aircraft: Fixed-wing configuration flight-test results

The fixed-wing, airplane configuration flight-test results of the Rotor System Research Aircraft (RSRA), NASA 740, at Ames/Dryden Flight Research Center are documented. Fourteen taxi and flight tests were performed from December 1983 to October 1984. This was the first time the RSRA was flown with the main rotor removed; the tail rotor was installed. These tests confirmed that the RSRA is operable as a fixed-wing aircraft. Data were obtained for various takeoff and landing distances, control sensitivity, trim and dynamics stability characteristics, performance rotor-hub drag, and acoustics signature. Stability data were obtained with the rotor hub both installed and removed. The speed envelope was developed to 261 knots true airspeed (KTAS), 226 knots calibrated airspeed (KCAS) at 10,000 ft density altitude. The airplane was configured at 5 deg. wing incidence with 5 deg. wing flaps as a normal configuration. Level-flight data were acquired at 167 KCAS for wing incidence from 0 to 10 deg. Step inputs and doublet inputs of various magnitudes were utilized to acquire dynamic stability and control sensitivity data. Sine-wave inputs of constantly increasing frequency were used to generate parameter identification data. The maximum load factor attained was 2.34 g at 206 KCAS.

Erickson, R. E.↗

Solar dynamic power systems for space station

The Parabolic Offset Linearly Actuated Reflector (POLAR) solar dynamic module was selected as the baseline design for a solar dynamic power system aboard the space station. The POLAR concept was chosen over other candidate designs after extensive trade studies. The primary advantages of the POLAR concept are the low mass moment of inertia of the module about the transverse boom and the compactness of the stowed module which enables packaging of two complete modules in the Shuttle orbiter payload bay. The fine pointing control system required for the solar dynamic module has been studied and initial results indicate that if disturbances from the station are allowed to back drive the rotary alpha joint, pointing errors caused by transient loads on the space station can be minimized. This would allow pointing controls to operate in bandwidths near system structural frequencies. The incorporation of the fine pointing control system into the solar dynamic module is fairly straightforward for the three strut concentrator support structure. However, results of structural analyses indicate that this three strut support is not optimum. Incorporation of a vernier pointing system into the proposed six strut support structure is being studied.

Irvine, Thomas B.↗

Simulating the Formation of Lunar Floor-Fracture Craters Using Elastoviscoplastic Relaxation

Lunar floor-fracture craters formed during the height of mare basalt emplacement. Due to a general temporal and spatial relation with the maria, these craters, numbering some 200, may be diagnostic of the thermal structure of the crust during this time. As the name suggests, these craters exhibit brittle failure, generally limited to the central floor region. That, and a shallower depth than fresh lunar craters, has led to two main theories as to their formation: laccolith emplacement under the crater and viscous relaxation. The implications of each model for the state of the Moon's crust during this time are quite different, so the viability of each model must be checked. Laccolith emplacement has been treated elsewhere. However, previous attempts to study the relaxation of the craters have assumed only a uniform, Newtonian viscous response of the near surface to the topographic driving forces, and simply postulated that the fractures resulted from tensile stresses associated with floor uplift. Here, we use a more sophisticated rheological model that includes not only non-Newtonian viscous behavior (i.e., the viscosity is stress-dependent), but also incorporates elastic behavior and a plastic component to the rheology to directly simulate the formation of the floor fractures. The results of our simulations show that while elastoviscoplastic relaxation is potentially viable for larger floor-fracture craters, it is not viable for craters with diameters < or = 60 km, the size of the majority of floor-fracture craters. We employ the finite element method, a numerical technique well suited for boundary-value problems, via the commercially available MARC software package. To test the viability of topographic relaxation, our goal is to prepare the simulations as to maximize the amount of relaxation. We take advantage of the natural axisymmetry of craters, simulating one radial plane. Initial shapes are based on data for fresh craters from Pike. To simplify implementation, a fourth order polynomial is used for the basin, while a third order inverse function is used for the rim. This form closely approximates the long-wavelength behavior of complex craters, while ignoring higher-frequency topography, save the rim. This approximation is appropriate because crater relaxation is strongly controlled by long-wavelength topography. Loading is accomplished assuming a uniform gravity field (1.62 m/s-square) and a uniform density of 2900 kg/cubic m. The initial stress state is set to be hydrostatic, with an additional pressure term to account for any overlying topography. This additional pressure term is tapered exponentially with depth. While the simulations quickly settle on a preferred stress state, and while the final solution is fairly insensitive to the choice of the e-folding depth of the taper, selecting an e-folding depth close to the diameter of the crater sets the initial stress state near the preferred state. We assume a diuranally averaged surface temperature of -20 C, and allow temperature to increase with depth at a rate of 50 K//km. Assuming a thermal conductivity of 2 W/in/K, this gradient translates to a heat flow of 100mW/square m, an extremely high value for the Moon. Temperature, of course, will not increase without bound. To maximize relaxation, we allow our temperature profile to increase linearly until it reaches the solidus (assumed to be 1200C) at a depth of 24.4 km, at which point it is kept constant. The presence of melt will drop the bulk viscosity; however, we have no rheological control for partial melts. Therefore, we make no attempt to simulate this situation. Elastoviscoplastic rheological model. In general, geologic materials can behave in three main ways: elastically, viscously (via solid-state creep), and brittly (plasticity is a continuum approach to simulate this phenomenon). We combine these three deformation mechanisms in an extended Maxwell solid, where the total strain can be broken down into a simple summation of the elastic, creep, and plastic strains. In relaxation phenomena in general, the system takes advantage of any means possible to eliminate deviatoric stresses by relaxing away the topography. Previous analyses have only modeled the viscous response. Comparatively, the elastic response in our model can augment the relaxation, to a point. This effect decreases as the elastic response becomes stiffer; indeed, in the limit of infinite elastic Young's modulus (and with no plasticity), the solution converges on the purely viscous solution. Igneous rocks common to the lunar near-surface have Young's modulii in the range of 10-100 GPa. To maximize relaxation, we use a Young's modulus of 10 GPa. (There is negligible sensitivity to the other elastic modulus, the Poisson's ratio; we use 0.25.) For the viscous response, we use a flow law for steady-state creep in thoroughly dried Columbia diabase, because the high plagioclase (about 70 vol%) and orthopyroxene (about 17 vol%) content is similar to the composition of the lunar highland crust as described by remote sensing and sample studies: noritic anorthosite. This flow law is highly non-Newtonian, i.e., the viscosity is highly stress dependent. That, and the variability with temperature, stands in strong contrast to previous examinations of lunar floor-fracture crater relaxation. To model discrete, brittle faulting, we assume "Byerlee's rule," a standard geodynamical technique. We implement this "rule" with an-angle of internal friction of about 40 deg, and a higher-than-normal cohesion of about 3.2 MPa (to approximate the breaking of unfractured rock). The actual behavior of geologic materials is more complex than in our rheological model, so the uncertainties in the plasticity do not represent the state-of-the-art error. Additional information is contained in the original.

Dombard, A. J.↗

High-bandwidth Dynamic Load Emulation of Mechanical Systems using Electric Drives

Machine drives are versatile systems that can be programmed to emulate a variety of mechanical loads. In this paper, we walk through the modeling and control framework of a shaft-coupled dual-motor drive system that is programmed to emulate a fictitious mechanical system. We quantitatively evaluate the control performance of such a system and derive a theoretical limit that explains its inaccuracy at high operating frequencies. To overcome this problem, we propose an alternate control structure that achieves the same control objective at high frequencies as well. After suitable adjustments are made to the controller, we validate its performance using simulation results.

machine drives ,load emulation, speed-torque chara↗

Adjustable Speed Drive Part-Load Efficiency - Motor Tip Sheet #11

An adjustable speed drive (ASD) is a device that controls the rotational speed of motor-driven equipment. Variable frequency drives (VFDs), the most common type of ASDs, efficiently meet varying process requirements by adjusting the frequency and voltage of the power supplied to an AC motor to enable it to operate over a wide speed range. External sensors monitor flow, liquid levels, or pressure and then transmit a signal to a controller that adjusts the frequency and speed to match process requirements.

Industrial, Industry↗

Use of Frequency Response Metrics to Assess the Planning and Operating Requirements for Reliable Integration of Variable Renewable Generation

An interconnected electric power system is a complex system that must be operated within a safe frequency range in order to reliably maintain the instantaneous balance between generation and load. This is accomplished by ensuring that adequate resources are available to respond to expected and unexpected imbalances and restoring frequency to its scheduled value in order to ensure uninterrupted electric service to customers. Electrical systems must be flexible enough to reliably operate under a variety of"change" scenarios. System planners and operators must understand how other parts of the system change in response to the initial change, and need tools to manage such changes to ensure reliable operation within the scheduled frequency range. This report presents a systematic approach to identifying metrics that are useful for operating and planning a reliable system with increased amounts of variable renewable generation which builds on existing industry practices for frequency control after unexpected loss of a large amount of generation. The report introduces a set of metrics or tools for measuring the adequacy of frequency response within an interconnection. Based on the concept of the frequency nadir, these metrics take advantage of new information gathering and processing capabilities that system operators are developing for wide-area situational awareness. Primary frequency response is the leading metric that will be used by this report to assess the adequacy of primary frequency control reserves necessary to ensure reliable operation. It measures what is needed to arrest frequency decline (i.e., to establish frequency nadir) at a frequency higher than the highest set point for under-frequency load shedding within an interconnection. These metrics can be used to guide the reliable operation of an interconnection under changing circumstances.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhanced Inertial Support: Modeling Fast Frequency Response Controls for Energy Storage System Inverters

Reduction of power system inertia is a growing concern for grid operators given the transition under way from conventional fossil generators to inverter-based resources. One key concern is the rapid and severe dip in power system frequency following a large disturbance which could trigger remedial actions including operation of under frequency load shedding (UFLS) relays. A potential solution is to utilize battery energy storage systems (BESS) to provide fast frequency response(FFR) to mitigate the system frequency impact of low system inertia. In this work, we investigate different control parameters to achieve modeled FFR response from BESS in the simulated US Western Interconnection. First, a very low inertia model is developed from an existing positive sequence model of the Western Interconnection. Afterwards, we tune the BESS dynamic response parameters to eliminate any risks of reaching UFLS relay thresholds following the loss of large generators. Finally, we investigate the relative impact of having large BESS units in comparison of multiple smaller units in the same area. The results of the analyses indicate that 1 GW of transmission-connected BESS can help mitigate the frequency drop caused by large generators outages in the Western Interconnection, and significantly reduce the risk of under frequency load shedding.

power system dynamic performance, Low Inertia, Fas↗

Spinning Reserve From Hotel Load Response: Initial Progress

This project was motivated by the fundamental match between hotel space conditioning load response capability and power system contingency response needs. As power system costs rise and capacity is strained demand response can provide a significant system reliability benefit at a potentially attractive cost. At ORNL s suggestion, Digital Solutions Inc. adapted its hotel air conditioning control technology to supply power system spinning reserve. This energy saving technology is primarily designed to provide the hotel operator with the ability to control individual room temperature set-points based upon occupancy (25% to 50% energy savings based on an earlier study [Kirby and Ally, 2002]). DSI added instantaneous local load shedding capability in response to power system frequency and centrally dispatched load shedding capability in response to power system operator command. The 162 room Music Road Hotel in Pigeon Forge Tennessee agreed to host the spinning reserve test. The Tennessee Valley Authority supplied real-time metering equipment in the form of an internet connected Dranetz-BMI power quality meter and monitoring expertise to record total hotel load during both normal operations and test results. The Sevier County Electric System installed the metering. Preliminary testing showed that hotel load can be curtailed by 22% to 37% depending on the outdoor temperature and the time of day. These results are prior to implementing control over the common area air conditioning loads. Testing was also not at times of highest system or hotel loading. Full response occurred in 12 to 60 seconds from when the system operator s command to shed load was issued. The load drop was very rapid, essentially as fast as the 2 second metering could detect, with all units responding essentially simultaneously. Load restoration was ramped back in over several minutes. The restoration ramp can be adjusted to the power system needs. Frequency response testing was not completed. Initial testing showed that the units respond very quickly. Problems with local power quality generated false low frequency signals which required testing to be stopped. This should not be a problem in actual operation since the frequency trip points will be staggered to generate a droop curve which mimics generator governor response. The actual trip frequencies will also be low enough to avoid power quality problems. The actual trip frequencies are too low to generate test events with sufficient regularity to complete testing in a reasonable amount of time. Frequency response testing will resume once the local power quality problem is fully understood and reasonable test frequency settings can be determined. Overall the preliminary testing was extremely successful. The hotel response capability matches the power system reliability need, being faster than generation response and inherently available when the power system is under the most stress (times of high system and hotel load). Periodic testing is scheduled throughout the winter and spring to characterize hotel response capability under a full range of conditions. More extensive testing will resume when summer outdoor temperatures are again high enough to fully test hotel response.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Practical gust load alleviation and flutter suppression control laws based on a LQG methodology

A modified linear quadratic Gaussian (LQG) synthesis procedure has been used to design low-order robust multiloop controllers for a flexible airplane. The introduction of properly constructed fictitious Gauss-Markov processes in the control loops allowed meeting classical frequency-domain stability criteria using the direct synthesis procedures of modern time-domain control theory. Model reduction was used to simplify the control laws to the point where they could be easily implemented on onboard flight computers. These control laws provided excellent gust load and flutter mode control with good stability margins and compared very favorably to other control laws synthesized by the classical root-locus technique.

Gangsaas, D.↗

Development of Radio Frequency Diesel Particulate Filter Sensor and Controls for Advanced Low Pressure Drop Systems to Reduce Engine Fuel Consumption (06B)

This project developed a radio frequencybased sensor for accurate measurement of diesel particulate filter (DPF) loading with advanced low pressuredrop aftertreatment systems. The resulting technology demonstrated engine efficiency improvements through optimization of the combined engineaftertreatment system while reducing emissions, system cost, and complexity to meet the DOE program objectives.

02 PETROLEUM↗