Search NASA⌕ Search

SEARCH · Search NASA

Results for “low and peak flows”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

A correlative study of simultaneously measured He(++) fluxes in the solar wind and in the magnetosphere utilizing Imp-1 and 1971-089A satellite data

Simultaneously measured He(++) fluxes in the solar wind and in the magnetosphere were studied using data from the plasma spectrometer on the Imp I satellite and the energetic ion mass spectrometer on the low altitude polar orbiting satellite 1971-89A. A detailed comparison of the He(++) energy spectra measured simultaneously in the solar wind and in the low altitude dayside polar cusp on March 7, 1972 was made. The energy-per-unit-charge range of the energetic ion mass spectrometer on board the polar orbiting satellite was 700 eV to 12 keV. Within this range there was a clear maximum in the He(++) energy spectrum at approximately 1.5 keV/nucleon. There was not a clearly defined maximum in the H(+) spectrum, but the data were consistent with a peak between 0.7 and 1.0 keV/nucleon. Both spectra could be reasonably well fit with a convecting Maxwellian plus a high energy tail; however, the mean velocity for He(++) distribution was significantly greater than that for the H(+) distribution. The simultaneous solar wind measurements showed the mean velocities for both ion species to be approximately 600 km/sec. The discrepancies between the relative velocity distributions in the low altitude cusp and those in the solar wind are consistent with a potential difference of approximately 1.4 kV along their flow direction between the two points of observation.

Shelley, E. G.↗

Performance of a V/STOL tilt nacelle inlet with blowing boundary layer control

A scale model of a V/STOL tilt nacelle fitted to a 0.508 m single stage fan was tested in the NASA Lewis low speed wind tunnel to determine the effect of diffuser blowing on the inlet aerodynamics and aeromechanical performance. The test was conducted over a range of freestream speeds (up to 120 knots) and angles-of attack (up to 120 deg). In general, diffuser blowing had a beneficial affect on all performance parameters. The angle-of-attack range for a separation-free flow substantially increased, and the fan face distortion reduced with a corresponding increase in total pressure recovery. Discrete narrow band blade stress peaks which were common to the nonblowing (baseline) configuration were eradicated with diffuser blowing.

Johns, A. L.↗

Fluid-structure interaction forces at pump-impeller-shroud surfaces for axial vibration analysis

The axial forces developed on a pump impeller shroud surfaces are analyzed using a bulk-flow model of the leakage path between the impeller and the housing. Shear stresses at the impeller and the housing surfaces are modeled according to Hirs's turbulent lubrication model. The calculated results yield predictions of resonance peaks of the fluid within the annulus formed by the impeller shroud and housing. Numerical results are presented for a double-suction single-stage pump, showing that the direct stiffness of the perturbed impeller shroud forces is negligible; the forces become important only for pumps with very low axial natural frequencies in comparison to the running speed.

Childs, D. W.↗

Some preliminary results of brush seal/rotor interference effects on leakage at zero and low rpm using a tapered-plug rotor

Some preliminary brush seal leakage results for ambient-temperature air are presented. Data for four nominal brush-rotor radial clearances of -0.09, -0.048, -0.008, and 0.035 mm were taken by using a tapered plug rotor at 0 and 400 rpm with rotor runout of 0.127 mm peak to peak. The brush seal nominal bore diameter was 38 mm with 0.05-mm bristles at 200 bristles/mm of circumference and a 0.61-mm fence height. Leakages were greater than predicted, but agreement was reasonable. Leakage rates were not significantly altered by hysteresis or inlet flow variations. Visualization studies showed that the bristles followed the 400-rpm excitation, and loading studies indicated that bristles slid relative to one another.

Hendricks, R. C.↗

High-tip-speed, low-loading transonic fan stage. Part 3: Final report

Tests were conducted on a high-tip-speed, low-loading transonic fan stage to determine the performance and inlet flow distortion tolerance of the design. The fan was designed for high efficiency at a moderate pressure ratio by designing the hub section to operate at minimum loss when the tip operates with an oblique shock. The design objective was an efficiency of 86 percent at a pressure ratio of 1.5, a specific flow (flow per unit annulus area) of 42 lb/sec-sq. ft (205.1 kgm/sec-m sq), and a tip speed of 1600 ft/sec (488.6 m/sec). During testing, a peak efficiency of 84 percent was achieved at design speed and design specific flow. At the design speed and pressure ratio, the flow was 4 percent greater than design, efficiency was 81 percent, and a stall margin of 24 percent was obtained. The stall line was improved with hub radial distortion but was reduced when the stage was tested with tip radial and circumferential flow distortions. Blade-to-blade values of static pressures were measured over the rotor blade tips.

Ware, T. C.↗

Preliminary Investigation of Performance of Variable-throat Extended-plug-type Nozzles over Wide Range of Nozzle Pressure Ratios

As part of an overall program for the experimental investigation of large-scale jet nozzles, a preliminary evaluation of the internal performance characteristics of several variable-throat extended-plug-type nozzles was obtained over a range of nozzle pressure rations from 2 to 15 with nozzle throat variations as great as 2:1. The extended-plug nozzle attained peak thrust coefficients as high as those which have been attained with fixed-geometry convergent-divergent nozzles. The thrust coefficients of the extended-plug nozzles were relatively insensitive to both nozzle pressure ratio and throat area over the range investigated. The lack of sensitivity of thrust coefficient to nozzle pressure ratio and throat area was due primarily to the absence of severe decreases in thrust coefficient, which are normally observed at low nozzle pressure ratios for convergent-divergent nozzles because of overexpansion. For choked flow, the flow coefficients of the extended-plug nozzles varied from 0.95 to 0.997. A ratio of the outer-shell exit area to nozzle throat area was found to be an important variable affecting nozzle performance. Most of the configurations reported herein showed a small decrease in thrust coefficient at low nozzle pressure ratios; however, it is believed that this characteristic can nearly be eliminated by proper nozzle design.

NOZZLES↗

Deep cumulonimbus cloud systems in the tropics with and without lightning

The thunderstorm frequency over the oceans during the Global Atmospheric Research Program Atlantic Tropical Experiment is quantified by examination of over 20,000 surface hourly observations from research ships. The overall thunderstorm frequency is one thunderstorm day per ship per month. There were many examples of intense mesoscale systems, such as squall lines, passing over the ships, extending to 13-17 km in altitude, but that nevertheless produce few reports of lightning. This reinforces the idea, based on data from other tropical ocean regions and from global satellite data, that in spite of the ubiquitous 'hot towers' over tropical oceans, marine cumulonimbus produce little lightning. Climatological data from the monsoon regions of the Tropics are analyzed to reveal that during periods of onshore flow and heavy rainfall the oceanic regime of high rainfall but little lightning moves onshore. A rain-thunderstorm ratio is defined and used to characterize convective rainfall regimes as continental (relatively little) or maritime (relatively great) rainfall compared to the number of thunderstorm days. In regions such as West Africa and south Asia, the seasonal rainfall peak is actually accompanied by a thunderstorm minimum. It is further suggested that the data support the idea, not original here, that vertical velocities in oceanic cumulonimbus clouds tend to be low compared with continental clouds. It is hypothesized that most oceanic storms have updrafts weaker than a posssible threshold value, below which the supercooled liquid water, large ice particles, and ice-ice collisions are not present in the mixed-phase region in sufficient concentrations for electrification leading to lightning.

Zipser, Edward J.↗

Fluid Transient Analysis During Priming of Evacuated Line

Pressure surges are critical in the design of spacecraft propellant feed lines. The pressure transients that occur during priming of feed lines are very important in the design and analysis of liquid propulsion systems. During the start-up of the propulsion system of a spacecraft, the process of filling of an evacuated pipeline is called priming. Priming can generate severe pressure peaks due to the slam (water hammer) of the propellant against a closed thruster valve. The downstream conditions strongly affect the pressure surge. In space systems, satellites, or interplanetary probes, the propellant lines are vacuum-pumped or filled with low pressure helium or nitrogen before the launch. Before operations, these lines are primed with a vaporizing liquid, sometimes in the presence of a non-condensable gas (NCG), which produces water hammer phenomena. The objective of the current study is to use a finite volume based network flow solver (Generalized Fluid System Simulation Program, GFSSP) for the numerical simulation of Priming in (a) a straight feedline and (b) a flow network. The geometrical configurations and dimensions for the pipe and other components used for the current study are identical to experimental study of Prickett et al.

Bandyopadhyay, Alak↗

Solar wind heavy ions from flare-heated coronal plasma

Information concerning the coronal expansion is carried by solar-wind heavy ions. Distinctly different energy-per-charge ion spectra are found in two classes of solar wind having the low kinetic temperatures necessary for E/q resolution of the ion species. Heavy-ion spectra which can be resolved are most frequently observed in the low-speed interstream (IS) plasma found between high speed streams; the streams are thought to originate from coronal holes. Although the sources of the IS plasma are uncertain, the heavy-ion spectra found there contain identifiable peaks of O, Si, and Fe ions. Such spectra indicate that the IS ionization state of O is established in coronal gas at a temperature of approximately 1.6 million K, while that of Fe is frozen in farther out at about 1.5 million K. On occasion anomalous spectra are found outside IS flows in solar wind with abnormally depressed local kinetic temperatures. The anomalous spectra contain Fe(16+) ions, not usually found in IS flows, and the derived coronal freezing-in temperatures are significantly higher. The coronal sources of some of these ionizationally hot flows are identified as solar flares.

Bame, S. J.↗

Development of a temperature measurement system with application to a jet in a cross flow experiment

A temperature measurement system, which allows the simultaneous sampling of up to 80 separate thermocouples, was developed. The minimum resolution for the system corresponds to + or - 0.16 C per least significant bit of the A/D converter. The time constant values lambda, for each of the 64 thermocouples, were determined experimentally at 7 mps. Software routines were used to correct the measured temperatures for the effect of lambda for each thermocouple. The temperature measurement system was utilized to study the thermal field of a heated jet discharging perpendicularly into a low and a high disturbance level cross stream for a given momentum flux ratio and for three overheated values. The peak instantaneous temperatures reveal that strong molecular diffusion was operative. Various measures of the thermal field, for the disturbed case, suggest that the jet column remains relatively compact while being buffeted by the ambient turbulence field and that its penetration, into the cross wind, is inhibited by the presence of the strong disturbance field.

Wark, C.↗

Hydrogen leak detection in the Space Shuttle

This study focuses on a helium gas jet flowing into room air. Measurements of helium concentration and velocity in the jet-air mixture are reported. The objective is to learn about jet characteristics so that dynamically similar hydrogen leaks may be located in the Space Shuttle. The hazardous gas detection system (HGDS) in the mobile launch pad uses mass spectrometers to monitor the shuttle environment for leaks. The mass spectrometers are fed by long sample tubes which draw gas from the payload bay, mid body, aft engine compartment and external tank. The overall purpose of this study is to improve the HGDS especially in its potential for locating hydrogen leaks. A rapid-response leak detection experiment was designed, built, and tested, following on the work done in this program last summer. The apparatus included a Perkin Elmer MGA-1200 mass spectrometer and air velocity transducer, both monitored by a Macintosh IIFX computer using LabVIEW software. A jet of helium flowing into the lab air simulated a gas leak. Steady helium or hydrogen-nitrogen jets were logged for concentration and velocity, and the power spectral density of each was computed. Last year, large eddies and vortices were visually seen with Schlieren imaging, and they were detected in the time plots of the various instruments. The response time of the MGA-1200 was found in the range of 0.05 to 0.1 sec. Pulsed concentration waves were clearly detected at 25 cycles per sec by spectral analysis of MGA data. No peaks were detected in the power spectrum, so in the present study, 10 Hz bandwidth-averaged power levels were examined at regular frequency intervals. The practical consequences of last year's study are as follows: sampling frequency should be increased above the present rate of 1 sample per second so that transients could be observed and analyzed with frequency response methods. Many more experiments and conditions were observed in this second summer, including the effects of orifice diameter, jet velocity, sample tube design, radial effects, vertical flow, and low hydrogen concentrations (1 percent). A frequent observation was that the power spectrum, calculated from the Fourier transform of concentration fluctuations, gives a separate piece of information from concentration. Many of the tests suggest that power is high where mixing occurs at the helium-air interface. This fact is apparently independent of the concentration level, which could be high or low, but depends on the sample location relative to the jet (leak) origin, whereas high concentration may be due to a strong leak far away or a small leak close to the sample tube. If the power is low for any concentration level, this would signify helium is arriving at the sample tube by diffusion, not chaotic mixing caused by the jet interaction with air. The practical result is to propose a modification of the HGDL mass spectrometer data sampling and software so that sampling rates could be capable of observing at least 25 Hz fluctuations.

Barile, Ronald G↗

Low-frequency electromagnetic plasma waves at comet P/Grigg-Skjellerup: Overview and spectral characteristics

Large-amplitude electromagnetic plasma waves are one of the dominant features of the solar wind-comet interaction. Wave characteristics strongly depend on parameters such as the solar wind flow and Alfven velocities and the angle between flow and interplanetary magnetic field as well as the production rate. With respect to the latter the flyby of the spacecraft Giotto at comet P/Griff-Skjellerup provides a unique possibility to study such waves in further detail. Pickup ion-related wave signatures have been observed up to a distance of 600,000 km from the nucleus. Peak spectral power in the spacecraft frame of reference occurs at frequencies mainly somewhat below the water group ion gyrofrequency. From this the waves are determined to be mainly left-hand polarized waves, causing one-sided pitch angle diffusion outbound. The wave activity strongly increases close to the comet; upstream it exhibits a quadratic dependence on the water group pickup ion free energy. Furthermore, a phenomenological study of the wave characteristics provides a unique description of the fine-structure of the interaction region. Indications of steepened magnetosonic waves have been found in the outbound magnetosheath region.

Glassmeier, Karl-Heinz↗

System efficiency of packed bed TES with radial flow vs. axial flow – Influence of aspect ratio

Here, this paper compares the net system efficiency, including thermal efficiency and pressure drop effects, of radial versus axial flow packed beds for thermal energy storage. The traditional packed bed system is a cylindrical geometry where fluid flows axially from one end to another. However, issues of thermal stratification and high-pressure drop have led to recent studies on radial flow systems. One potential benefit is the reduced pressure drop in a radial flow system. This paper compares the performance of radial flow and axial flow systems at a range of aspect ratios (AR = H/D bed ) from 0.21 to 1.92 using a numerical model where the storage volume is held constant in all cases. When the radial flow bed is at a low aspect ratio (short/wide), the thermal front is improved but the pressure drop is high. At a high aspect ratio, the velocity is reduced in radial flow, leading to decreased pressure drop but an increased spreads in the thermal front that lowers thermal efficiency. The opposite trends are noted in axial flow. Thermal efficiencies of 83–91 % were noted for radial flow, while they ranged from 85 to 94 % in axial flow. Net efficiencies including pressure drop ranged from 74 to 82 % for radial flow and 80–87 % for axial flow. In both systems, a peak net efficiency was noted between the highest and lowest aspect ratio. While some aspect ratios with radial flow outperform axial flow from a net efficiency perspective, the results show that the highest net efficiency from axial flow is higher than that from radial flow. Overall, this paper highlights the importance of innovative TES designs and their potential to improve energy efficiency.

25 ENERGY STORAGE↗

Pressure fluctuations in the tip region of a blunt-tipped airfoil

The characteristics of turbulence generated in the tip region of a blunt-tipped airfoil were studied using surface pressure measurements. The model was a NACA 0012; tests were performed at flow speeds of 75, 55, and 35 m/s and angles of attack of 6, 12, and 16 deg. Reynolds numbers based on the wing chord were 1.9, 3.0, and 4.1 million. Pressure fluctuations measured near the primary tip-vortex on the upper, low pressure side of the wing tip were uncorrelated with those on the blunt tip. Fluctuations on the high pressure side of the wing were strongly correlated with those on the flat tip, but 10-20 dB less intense. Spectra measured on the flat tip displayed pronounced peaks at dimensionless frequencies of 0.8 to 1.3. Cross correlations between some of the flat-tip pressures displayed two echolike groupings. A model is proposed that explains these correlations.

Mcinerny, S. A.↗

Analysis of homogeneous turbulent reacting flows

Full turbulence simulations at low Reynolds numbers were made for the single-step, irreversible, bimolecular reaction between non-premixed reactants in isochoric, decaying homogeneous turbulence. Various initial conditions for the scalar field were used in the simulations to control the initial scalar dissipation length scale, and simulations were also made for temperature-dependent reaction rates and for non-stoichiometric and unequal diffusivity conditions. Joint probability density functions (pdf's), conditional pdf's, and various statistical quantities appearing in the moment equations were computed. Preliminary analysis of the results indicates that compressive strain-rate correlates better than other dynamical quantities with local reaction rate, and the locations of peak reaction rates seem to be insensitive to the scalar field initial conditions.

Leonard, A. D.↗

Low-latitude zonal and vertical ion drifts seen by DE 2

Horizontal and vertical ion drift data from the DE 2 spacecraft have been used to determine average zonal and vertical plasma flow (electric field) characteristics in the +/- 26-deg dip latitude region during a time of high solar activity. The 'average data' local time profile for an apex height bin centered at 400 km indicates westward plasma flow from 0600 to 1900 solar local time ((SLT) with a maximum westward velocity of 80 m/s in the early afternoon. There is a sharp change to eastward flow at approximately 1900 hours with an early evening peak of 170 m/s. A secondary nighttime maximum exists at 0430 SLT preceeding the reversal to westward flow. This profile is in good agreement with Jicamarca, Peru, radar measurements made under similar solar maximum conditions. Haramonic analysis indicates a net superrotation which is strongest at lower apex altitudes. The diurnal term is dominant, but higher order terms through the quatradiurnal are significant.

Coley, W. R.↗

Model Development and Experimental Validation of the Fusible Heat Sink Design for Exploration Vehicles

The Fusible Heat Sink is a novel vehicle heat rejection technology which combines a flow through radiator with a phase change material. The combined technologies create a multi-function device able to shield crew members against Solar Particle Events (SPE), reduce radiator extent by permitting sizing to the average vehicle heat load rather than to the peak vehicle heat load, and to substantially absorb heat load excursions from the average while constantly maintaining thermal control system setpoints. This multi-function technology provides great flexibility for mission planning, making it possible to operate a vehicle in hot or cold environments and under high or low heat load conditions for extended periods of time. This paper describes the model development and experimental validation of the Fusible Heat Sink technology. The model developed was intended to meet the radiation and heat rejection requirements of a nominal MMSEV mission. Development parameters and results, including sizing and model performance will be discussed. From this flight-sized model, a scaled test-article design was modeled, designed, and fabricated for experimental validation of the technology at Johnson Space Center thermal vacuum chamber facilities. Testing showed performance comparable to the model at nominal loads and the capability to maintain heat loads substantially greater than nominal for extended periods of time.

Cognata, Thomas J.↗

Model Development and Experimental Validation of the Fusible Heat Sink Design for Exploration Vehicles

The Fusible Heat Sink is a novel vehicle heat rejection technology which combines a flow through radiator with a phase change material. The combined technologies create a multi-function device able to shield crew members against Solar Particle Events (SPE), reduce radiator extent by permitting sizing to the average vehicle heat load rather than to the peak vehicle heat load, and to substantially absorb heat load excursions from the average while constantly maintaining thermal control system setpoints. This multi-function technology provides great flexibility for mission planning, making it possible to operate a vehicle in hot or cold environments and under high or low heat load conditions for extended periods of time. This paper describes the modeling and experimental validation of the Fusible Heat Sink technology. The model developed was intended to meet the radiation and heat rejection requirements of a nominal MMSEV mission. Development parameters and results, including sizing and model performance will be discussed. From this flight-sized model, a scaled test-article design was modeled, designed, and fabricated for experimental validation of the technology at Johnson Space Center thermal vacuum chamber facilities. Testing showed performance comparable to the model at nominal loads and the capability to maintain heat loads substantially greater than nominal for extended periods of time.

Cognata, Thomas J.↗