Search NASA⌕ Search

SEARCH · Search NASA

Results for “microscopic analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Medical Image Analysis Facility

To improve the quality of photos sent to Earth by unmanned spacecraft. NASA's Jet Propulsion Laboratory (JPL) developed a computerized image enhancement process that brings out detail not visible in the basic photo. JPL is now applying this technology to biomedical research in its Medical lrnage Analysis Facility, which employs computer enhancement techniques to analyze x-ray films of internal organs, such as the heart and lung. A major objective is study of the effects of I stress on persons with heart disease. In animal tests, computerized image processing is being used to study coronary artery lesions and the degree to which they reduce arterial blood flow when stress is applied. The photos illustrate the enhancement process. The upper picture is an x-ray photo in which the artery (dotted line) is barely discernible; in the post-enhancement photo at right, the whole artery and the lesions along its wall are clearly visible. The Medical lrnage Analysis Facility offers a faster means of studying the effects of complex coronary lesions in humans, and the research now being conducted on animals is expected to have important application to diagnosis and treatment of human coronary disease. Other uses of the facility's image processing capability include analysis of muscle biopsy and pap smear specimens, and study of the microscopic structure of fibroprotein in the human lung. Working with JPL on experiments are NASA's Ames Research Center, the University of Southern California School of Medicine, and Rancho Los Amigos Hospital, Downey, California.

Source record↗

Macro vs. Micro: Relating the Spectral Properties of Vesta and the HED Meteorite

We present the main results obtained comparing the visible-near infrared (VIS-NIR) spectra Vesta s surface with howardites, eucrites, diogenites (HED). HEDs are commonly associated with Vesta s composition based on spectral similarities. Because of such association, much effort is being made to merge the information from HEDs as well as Vestoids - with that from Vesta to characterize the lithologic diversity of the surface of this asteroid and to infer clues regarding its thermal history. However, while the HEDs are a class of meteorites well studied in the laboratory, the only spectral data available for Vesta until now were telescopic observations which are limited in terms of observation conditions, spatial resolution and Signal to Noise Ratio. The Dawn spacecraft, orbiting around Vesta since July 2011, is performing detailed observations of this body and thus improving our knowledge of its properties. Dawn s scientific payload includes an imaging spectrometer, VIR-MS, sensitive to the VIS-NIR spectral range. VIR-MS began acquiring spectra during the approach phase started in May 2011 and will continue its observations through July 2012 when the spacecraft will depart Vesta to travel to Ceres. The VIR-MS spatial resolution depends upon the mission phase (approach, survey, high altitude, low altitude). However, spectra acquired by VIR-MS have already exceeded the spatial resolution of ground-based telescopic observations, with resolution in the approach phase ranging from 2.5 up to 0.8 km/pixel. Moreover, the observations are uniformly distributed in latitude and longitude allowing us to have a global view of Vesta s crust spectral properties. Using the information provided by VIR spectra, we studied the distribution of the spectral heterogeneities on the surface and we used our findings to perform a comparison with HEDs spectra in the VIS-NIR spectral range searching for analogies and/or incompatibilities. In our analysis, we focused on a method to compare the results obtained at microscopic scale on HEDs samples and the one obtained at macroscopic scale on the surface of Vesta. Finally, we discuss our results in the context of vestan thermal history. The intent of this study is to improve our understanding of the connection between Vesta and the HED samples, which is one of the primary Dawn scientific objectives. This work is supported by an Italian Space Agency (ASI) grant and by NASA through the Dawn project and a Dawn at Vesta Participating Scientist grant.

Ammannito, E.↗

Orion Exploration Flight Test Post-Flight Inspection and Analysis

The principal mechanism for developing orbital debris environment models, is to make observations of larger pieces of debris in the range of several centimeters and greater using radar and optical techniques. For particles that are smaller than this threshold, breakup and migration models of particles to returned surfaces in lower orbit are relied upon to quantify the flux. This reliance on models to derive spatial densities of particles that are of critical importance to spacecraft make the unique nature of the EFT-1's return surface a valuable metric. To this end detailed post-flight inspections have been performed of the returned EFT-1 backshell, and the inspections identified six candidate impact sites that were not present during the pre-flight inspections. This paper describes the post-flight analysis efforts to characterize the EFT-1 mission craters. This effort included ground based testing to understand small particle impact craters in the thermal protection material, the pre- and post-flight inspection, the crater analysis using optical, X-ray computed tomography (CT) and scanning electron microscope (SEM) techniques, and numerical simulations.

Miller, J. E.↗

Development and Optical Testing of the Camera, Hand Lens, and Microscope Probe with Scannable Laser Spectroscopy (CHAMP-SLS)

Conducting high resolution field microscopy with coupled laser spectroscopy that can be used to selectively analyze the surface chemistry of individual pixels in a scene is an enabling capability for next generation robotic and manned spaceflight missions, civil, and military applications. In the laboratory, we use a range of imaging and surface preparation tools that provide us with in-focus images, context imaging for identifying features that we want to investigate at high magnification, and surface-optical coupling that allows us to apply optical spectroscopic analysis techniques for analyzing surface chemistry particularly at high magnifications. The camera, hand lens, and microscope probe with scannable laser spectroscopy (CHAMP-SLS) is an imaging/spectroscopy instrument capable of imaging continuously from infinity down to high resolution microscopy (resolution of approx. 1 micron/pixel in a final camera format), the closer CHAMP-SLS is placed to a feature, the higher the resultant magnification. At hand lens to microscopic magnifications, the imaged scene can be selectively interrogated with point spectroscopic techniques such as Raman spectroscopy, microscopic Laser Induced Breakdown Spectroscopy (micro-LIBS), laser ablation mass-spectrometry, Fluorescence spectroscopy, and/or Reflectance spectroscopy. This paper summarizes the optical design, development, and testing of the CHAMP-SLS optics.

Fluorescence↗

Failure Analysis of Heavy-Ion-Irradiated Schottky Diodes

In this paper, we use high- and low-magnification optical microscope images, thermal infrared camera images, and scanning electron microscope images to identify failure locations in heavy-ion-irradiated Schottky diodes. After failures have been identified, the parts were cross-sectioned to describe the structure of the failures and energy dispersive x-ray spectroscopy was used to characterize the materials in the failure structures.

Radiation effects↗

X-Ray Microanalysis and Electron Energy Loss Spectrometry in the Analytical Electron Microscope: Review and Future Directions

This paper reviews and discusses future directions in analytical electron microscopy for microchemical analysis using X-ray and Electron Energy Loss Spectroscopy (EELS). The technique of X-ray microanalysis, using the ratio method and k(sub AB) factors, is outlined. The X-ray absorption correction is the major barrier to the objective of obtaining I% accuracy and precision in analysis. Spatial resolution and Minimum Detectability Limits (MDL) are considered with present limitations of spatial resolution in the 2 to 3 microns range and of MDL in the 0.1 to 0.2 wt. % range when a Field Emission Gun (FEG) system is used. Future directions of X-ray analysis include improvement in X-ray spatial resolution to the I to 2 microns range and MDL as low as 0.01 wt. %. With these improvements the detection of single atoms in the analysis volume will be possible. Other future improvements include the use of clean room techniques for thin specimen preparation, quantification available at the I% accuracy and precision level with light element analysis quantification available at better than the 10% accuracy and precision level, the incorporation of a compact wavelength dispersive spectrometer to improve X-ray spectral resolution, light element analysis and MDL, and instrument improvements including source stability, on-line probe current measurements, stage stability, and computerized stage control. The paper reviews the EELS technique, recognizing that it has been slow to develop and still remains firmly in research laboratories rather than in applications laboratories. Consideration of microanalysis with core-loss edges is given along with a discussion of the limitations such as specimen thickness. Spatial resolution and MDL are considered, recognizing that single atom detection is already possible. Plasmon loss analysis is discussed as well as fine structure analysis. New techniques for energy-loss imaging are also summarized. Future directions in the EELS technique will be the development of new spectrometers and improvements in thin specimen preparation. The microanalysis technique needs to be simplified and software developed so that the EELS technique approaches the relative simplicity of the X-ray technique. Finally, one can expect major improvements in EELS imaging as data storage and processing improvements occur.

Goldstein, J. I.↗

Analysis of Samples from Asteroid Ryugu Returned by Hayabusa2

After returning to Earth in the winter of 2020, the samples from Cb-type asteroid Ryugu were stored under atmosphere-free conditions at the Extraterrestrial Materials Curation Center of ISAS/JAXA, and investigated for basic descriptions (sample imaging, weighing, etc.). They were distributed to six initial analysis teams in Japan in June 2021. The "Stone" team, in charge of analysis of coarse particles (>1 mm in size), conducted a series of analyses using a variety of techniques including reflectance spectra measurement, synchrotron-radiation three-dimensional elemental and mineralogical analysis, bulk elemental analysis using muon beam, Fe valence state measurement by XANES and Mössbauer spectroscopy, detailed mineralogical and petrological characterization by scanning and transmission electron microscopes. Physical and thermal properties of Ryiugu samples were measured to understand the response to shock and heating. In this talk, I would like to introduce summary of analysis results and what comes to be known about the formation and evolution of asteroid Ryugu.

Tomoki Nakamura↗

Coordinated Mineralogical and Isotopic Analysis of a Cosmic Symplectite Identified in a Stardust Terminal Particle

Comet Wild-2 samples returned by the Stardust spacecraft contain a chemically diverse mixture of material, underscoring the complex nature of comets. Studies of entire Stardust aerogel tracks afford the opportunity to examine the fine-grained particle fragments distributed along the length of the track as well as the terminal particles. Previous TEM characterization of a terminal particle (TP) in track #147 revealed a symplectically intergrown iron sulfide and oxide assemblage. Mineralogically similar assemblages, known as cosmic symplectites (COS, formerly termed "new-PCP"), have only been identified in the primitive carbonaceous chondrite Acfer 094. Meteoritic COS have isotopically heavy O compositions (delta (sup 17), O-18 = 180per mille) that point to interactions with early solar system primordial water. In this study we report mineralogical and O isotopic measurements of the Wild-2 COS assemblage. Experimental: Track #147 is a "bulbous"-type track (4600 microns long) containing 7 terminal particles. The TPs were removed from the track, embedded in epoxy, and ultramicrotomed. A JEOL 2500SE 200 keV field-emission scanning-transmission electron microscope was used to obtain quantitative elemental maps and detailed mineralogical characterization. Following TEM analysis, two thin sections of TP4 (12 microns) were analyzed for O isotopes by raster ion imaging with the JSC NanoSIMS 50L. All three O isotopes were measured simultaneously using electron multipliers. San Carlos olivine grains were used as isotopic standards. Results and Discussion: The COS in the Wild-2 track #147 TP4 sample consists of symplectically intergrown pentlandite and nanocrystalline maghemite which coexists with high-Ca pyroxene with Na and Cr (kosmochlor component). This kosmochlor component could have a nebular origin and be precursors to type II chondrules in ordinary chondrites. Yet pentlandite is not a stable phase in the nebula. The COS in Acfer 094 also consists of pentlandite, but contains magnetite [4] rather than the more oxidized maghemite observed in the Wild-2 COS. The Acfer 094 COS display heavy O isotopic compositions that are the result of sulfidization and oxidation of Fe, Ni-metal grains and sulfides by O-17- and O-18-rich water in the solar nebula or possibly on the parent body. The O isotopic composition of the Wild-2 COS, however, is indistinguishable from terrestrial, indicating it was not altered by the same primordial aqueous reservoir as the Acfer 094 COS. The alteration could have occurred on the parent body by isotopically equilibrated ice. The mineralogy and petrography of Wild-2 samples suggests an incomplete or nascent hydration process. In future work we will analyze S isotopes in the track #147 TP4 COS and search for additional COS in Stardust samples.

Nguyen, A. N.↗

Low scatter lens design/development

The criteria for the optimum design of optical systems are discussed along with the selection of appropriate materials. The construction details of low scatter lens systems are tabulated. Scattering analysis; total energy diffracted; and computation of delta for a scratch, bubble, and microscopic irregularities are also discussed.

Gallipeau, R. B.↗

Application of surface analysis to solve problems of wear

Results are presented for the use of surface analytical tools including field ion microscopy, Auger emission spectroscopy analysis (AES), cylindrical mirror Auger analysis and X-ray photoelectron spectroscopy (XPS). Data from the field ion microscope reveal adhesive transfer (wear) at the atomic level with the formation of surface compounds not found in the bulk, and AES reveals that this transfer will occur even in the presence of surface oxides. Both AES and XPS reveal that in abrasive wear with silicon carbide and diamond contacting the transition metals, the surface and the abrasive undergo a chemical or structural change which effects wear. With silicon carbide, silicon volatilizes leaving behind a pseudo-graphitic surface and the surface of diamond is observed to graphitize.

Buckley, D. H.↗

A study of microstructural characteristics of Ni-based superalloys at high temperatures

The microstructure of the Ni-based superalloy MAR-M246 (Hf) which is used in manufacturing the components of the Space Shuttle Main Engine was investigated. In the first year, the superalloy will be studied using optical photomicrographs and the differential thermal analysis. During this period, the existing experimental equipment like cutting, grinding/polishing machines, metallurgical microscope will be used to but/polish and take the photomicrographs. At present, only a 35 mm camera attachment with the olympus inverted metallurgical microscope is being used. Due to this, there was considerable delay in processing photographs. A Perkin-Elmer Differential Thermal Analyzer (DTA-1700) was ordered and finally installed on April 28, 1987. Preliminary test runs were made on silver as well as MAR-M246 (Hf).

Lal, R. B.↗

High Temperature Transfer Molding Resins: Preliminary Composite Properties of PETI-375

As part of an ongoing effort to develop materials for resin transfer molding (RTM) of high performance/high temperature composites, a new phenylethynyl containing imide designated as PETI-375 has been under evaluation. PETI-375 was prepared using 2,3,3 ,4 - biphenyltetracarboxylic dianhydride (a-BPDA), 1,3-bis(4-aminophenoxy)benzene and 2,2 - bis(trifluoromethyl)benzidine and endcapped with 4-phenylethynylphthalic anhydride. This material exhibited a stable melt viscosity of 0.1-0.4 Pa sec at 280 C. High quality, void-free laminates were fabricated by high temperature RTM using unsized T-650 carbon fabric and evaluated. After curing for 1 hour at 371 C, the laminates exhibited a glass transition temperature of approx. 375 C by thermomechanical analysis. The laminates were essentially void and microcrack free as evidenced by optical microscopic examination. The chemistry, physical, and composite properties of PETI-375 will be discussed.

Connell, J. W.↗

Using Piezoelectric Ceramics for Dust Mitigation of Space Suits

The particles that make up moon dust and Mars soil can be hazardous to an astronaut s health if not handled properly. In the near future, while exploring outer space, astronauts plan to wander the surfaces of unknown planets. During these explorations, dust and soil will cling to their space suits and become imbedded in the fabric. The astronauts will track moon dust and mars soil back into their living quarters. This not only will create a mess with millions of tiny air-born particles floating around, but will also be dangerous in the case that the fine particles are breathed in and become trapped in an astronaut s lungs. research center are investigating ways to remove these particles from space suits. This problem is very difficult due to the nature of the particles: They are extremely small and have jagged edges which can easily latch onto the fibers of the fabric. For the past summer, I have been involved in researching the potential problems, investigating ways to remove the particles, and conducting experiments to validate the techniques. The current technique under investigation uses piezoelectric ceramics imbedded in the fabric that vibrate and shake the particles free. The particles will be left on the planet s surface or collected a vacuum to be disposed of later. The ceramics vibrate when connected to an AC voltage supply and create a small scale motion similar to what people use at the beach to shake sand off of a beach towel. Because the particles are so small, similar to volcanic ash, caution must be taken to make sure that this technique does not further inbed them in the fabric and make removal more difficult. Only a very precise range of frequency and voltage will produce a suitable vibration. My summer project involved many experiments to determine the correct range. Analysis involved hands on experience with oscilloscopes, amplifiers, piezoelectrics, a high speed camera, microscopes and computers. perfect this technology. Someday, vibration to remove dust may a vital component to the space exploration program. In order to mitigate this problem, engineers and scientists at the NASA-Glenn Further research and experiments are planned to better understand and ultimately

Angel, Heather K.↗

An Automatic Phase-Change Detection Technique for Colloidal Hard Sphere Suspensions

Colloidal suspensions of monodisperse spheres are used as physical models of thermodynamic phase transitions and as precursors to photonic band gap materials. However, current image analysis techniques are not able to distinguish between densely packed phases within conventional microscope images, which are mainly characterized by degrees of randomness or order with similar grayscale value properties. Current techniques for identifying the phase boundaries involve manually identifying the phase transitions, which is very tedious and time consuming. We have developed an intelligent machine vision technique that automatically identifies colloidal phase boundaries. The algorithm utilizes intelligent image processing techniques that accurately identify and track phase changes vertically or horizontally for a sequence of colloidal hard sphere suspension images. This technique is readily adaptable to any imaging application where regions of interest are distinguished from the background by differing patterns of motion over time.

McDowell, Mark↗

Triamcinolone Acetonide Selectively Inhibits Angiogenesis in Small Blood Vessels and Decreases Vessel Diameter within the Vascular Tree

The steroid triamcinolone acetonide (TA) is a potent anti-angiogenesis drug used to treat retinal vascular diseases that include diabetic retinopathy, vascular occlusions and choroidal neovascularization. To quantify the effects of TA on branching morphology within the angiogenic microvascular tree of the chorioallantoic membrane (CAM) of quail embryos. Increasing concentrations of TA (0-16 ng/ml) were applied topically on embryonic day 7 (E7) to the chorioallantoic membrane (CAM) of quail embryos cultured in Petri dishes, and incubated for an additional 24 or 48 hours until fixation. Binary (black/white) microscopic images of arterial end points were quantified by VESGEN software (for Generational Analysis of Vessel Branching) to obtain major vascular parameters that include vessel diameter (Dv), fractal dimension (Df), tortuosity (Tv) and densities of vessel area, length, number and branch point (Av, Lv, Nv and Brv). For assessment of specific changes in vascular morphology induced by TA, the VESGEN software automatically segmented the vascular tree into branching generations (G1...G10) according to changes in vessel diameter and branching. Vessel density decreased significantly up to 34% as the function of increasing concentration of TA according to Av, Lv, Brv, Nv and Df. TA selectively inhibited the growth of new, small vessels, because Lv decreased from 13.14plus or minus 0.61 cm/cm2 for controls to 8.012 plus or minus 0.82 cm/cm2 at 16 ng TA/ml in smaller branching generations (G7-G10), and for Nv from 473.83 plus or minus 29.85 cm(-)2 to 302.32 plus or minus 33.09 cm-()2. In contrast, vessel diameter (Dv) decreased throughout the vascular tree (G1-G10).

McKay, Terri L.↗

Compact Microscope Imaging System Developed

The Compact Microscope Imaging System (CMIS) is a diagnostic tool with intelligent controls for use in space, industrial, medical, and security applications. The CMIS can be used in situ with a minimum amount of user intervention. This system, which was developed at the NASA Glenn Research Center, can scan, find areas of interest, focus, and acquire images automatically. Large numbers of multiple cell experiments require microscopy for in situ observations; this is only feasible with compact microscope systems. CMIS is a miniature machine vision system that combines intelligent image processing with remote control capabilities. The software also has a user-friendly interface that can be used independently of the hardware for post-experiment analysis. CMIS has potential commercial uses in the automated online inspection of precision parts, medical imaging, security industry (examination of currency in automated teller machines and fingerprint identification in secure entry locks), environmental industry (automated examination of soil/water samples), biomedical field (automated blood/cell analysis), and microscopy community. CMIS will improve research in several ways: It will expand the capabilities of MSD experiments utilizing microscope technology. It may be used in lunar and Martian experiments (Rover Robot). Because of its reduced size, it will enable experiments that were not feasible previously. It may be incorporated into existing shuttle orbiter and space station experiments, including glove-box-sized experiments as well as ground-based experiments.

McDowell, Mark↗

SEM analysis of ionizing radiation effects in linear integrated circuits

A successful diagnostic technique was developed using a scanning electron microscope (SEM) as a precision tool to determine ionization effects in integrated circuits. Previous SEM methods radiated the entire semiconductor chip or major areas. The large area exposure methods do not reveal the exact components which are sensitive to radiation. To locate these sensitive components a new method was developed, which consisted in successively irradiating selected components on the device chip with equal doses of electrons /10 to the 6th rad (Si)/, while the whole device was subjected to representative bias conditions. A suitable device parameter was measured in situ after each successive irradiation with the beam off.

Stanley, A. G.↗

Lunar sample 14425 - Corrected analysis

A polished section of lunar sample 14425, an 8 mm glass bead, was studied using a scanning electron microscope and energy-dispersive X-ray analyzer. The silicon, aluminum, iron, magnesium, calcium, sodium, potassium, titanium, and chromium contents of the glass were determined. Two types of glass are visible in the polished section. One is clear and almost devoid of metallic spherules, while the other is cloudy and contains numerous metallic spherules, some less than one micron in size. Both glass types are homogeneous and identical in composition. This composition closely matches that of some Apollo 14 breccias or glass found in the breccias. The apparent similarity in composition between lunar sample 14425 and the high-magnesium microtektites found in a previous study was probably due to charging effects during analyses in which the sample was uncoated.

Glass, B. P.↗