Scramjet Performance Assessment Using Water Absorption Diagnostics (U)

Simultaneous multiple path measurements of temperature and H2O concentration will be presented for the AIMHYE test entries in the NASA Ames 16-Inch Shock Tunnel. Monitoring the progress of high temperature chemical reactions that define scramjet combustor efficiencies is a task uniquely suited to nonintrusive optical diagnostics. One application strategy to overcome the many challenges and limitations of nonintrusive measurements is to use laser absorption spectroscopy coupled with optical fibers. Absorption spectroscopic techniques with rapidly tunable lasers are capable of making simultaneous measurements of mole fraction, temperature, pressure, and velocity. The scramjet water absorption diagnostic was used to measure combustor efficiency and was compared to thrust measurements using a nozzle force balance and integrated nozzle pressures to develop a direct technique for evaluating integrated scramjet performance. Tests were initially performed with a diode laser tuning over a water absorption feature at 1391.7 nm. A second diode laser later became available at a wavelength near 1343.3 nm covering an additional water absorption feature and was incorporated in the system for a two-wavelength technique. Both temperature and mole fraction can be inferred from the lineshape analysis using this approach. Additional high temperature spectroscopy research was conducted to reduce uncertainties in the scramjet application. The lasers are optical fiber coupled to ports at the combustor exit and in the nozzle region. The output from the two diode lasers were combined in a single fiber, and the resultant two-wavelength beam was subsequently split into four legs. Each leg was directed through 60 meters of optical fiber to four combustor exit locations for measurement of beam intensity after absorption by the water within the flow. Absorption results will be compared to 1D combustor analysis using RJPA and nozzle CFD computations as well as to data from a nozzle metric balance measuring thrust and integrated pressure measurements along the length of the nozzle. Assessment of its value as a combustor performance evaluation tool will be conducted.

Cavolowsky, John A.↗

Modular biowaste monitoring system conceptual design

The objective of the study was to define requirements and generate a conceptual design for a Modular Biowaste Monitoring System for specifically supporting shuttle life science experimental and diagnostic programs.

Fogal, G. L.↗

Dynamic Stability Instrumentation System (DSIS): User Manual - Volume 3

The paper is an operating manual for the Dynamic Stability Instrumentation System in specific NASA Langley wind tunnels. The instrumentation system performs either a synchronous demodulation or a Fast Fourier Transform on dynamic balance strain gage signals, and ultimately computes aerodynamic coefficients. The dynamic balance converts sting motor rotation into pitch or yaw plane or roll axis oscillation, with timing information provided by a shaft encoder. Additional instruments control model attitude and balance temperature and monitor sting vibrations. Other instruments perform self-calibration and diagnostics. Procedures for conducting calibrations and wind-off and wind-on tests are listed.

Daniels, Taumi S.↗

In-flight Fault Detection and Isolation in Aircraft Flight Control Systems

In this paper we consider the problem of test design for real-time fault detection and isolation (FDI) in the flight control system of fixed-wing aircraft. We focus on the faults that are manifested in the control surface elements (e.g., aileron, elevator, rudder and stabilizer) of an aircraft. For demonstration purposes, we restrict our focus on the faults belonging to nine basic fault classes. The diagnostic tests are performed on the features extracted from fifty monitored system parameters. The proposed tests are able to uniquely isolate each of the faults at almost all severity levels. A neural network-based flight control simulator, FLTZ(Registered TradeMark), is used for the simulation of various faults in fixed-wing aircraft flight control systems for the purpose of FDI.

Azam, Mohammad↗

Robotic Planetary Drill Tests

Several proposed or planned planetary science missions to Mars and other Solar System bodies over the next decade require subsurface access by drilling. This paper discusses the problems of remote robotic drilling, an automation and control architecture based loosely on observed human behaviors in drilling on Earth, and an overview of robotic drilling field test results using this architecture since 2005. Both rotary-drag and rotary-percussive drills are targeted. A hybrid diagnostic approach incorporates heuristics, model-based reasoning and vibration monitoring with neural nets. Ongoing work leads to flight-ready drilling software.

Glass, Brian J.↗

Collaborative Business Models for Exploration: - The Expansion of Public-Private Partnerships to Enable Exploration and Improve the Quality of Life on Earth

In May of 2007, The Space Life Sciences Strategy was published, launching a series of efforts aimed at driving human health and performance innovations that both meet space flight needs and benefit life on Earth. These efforts, led by the Space Life Science Directorate (SLSD) at the NASA Johnson Space Center, led to the development and implementation of the NASA Human Health and Performance Center (NHHPC) in October 2010. The NHHPC now has over 100 members including seven NASA centers; other federal agencies; some of the International Space Station partners; industry; academia and non-profits. The NHHPC seeks to share best practices, develop collaborative projects and experiment with open collaboration techniques such as crowdsourcing. Using this approach, the NHHPC collaborative projects are anticipated to be at the earliest possible stage of development utilizing the many possible public-private partnerships in this center. Two workshops have been successfully conducted in 2011 (January and October) with a third workshop planned for the spring of 2012. The challenges of space flight are similar in many respects to providing health care and environmental monitoring in challenging settings on the earth. These challenges to technology development include the need for low power consumption, low weight, in-situ analysis, operator independence (i.e., minimal training), robustness, and limited resupply or maintenance. When similar technology challenges are identified (such as the need to provide and monitor a safe water supply or develop a portable medical diagnostic device for remote use), opportunities arise for public-private partnerships to engage in co-creation of novel approaches for space exploration and health and environmental applications on earth. This approach can enable the use of shared resources to reduce costs, engage other organizations and the public in participatory exploration (solving real-world problems), and provide technologies with multiple uses for space exploration and life on earth. Several examples will be provided that demonstrate the application of a technology to solve a space exploration need and to provide a positive impact to the quality of life on earth.

Davis, Jeffrey R.↗

General Purpose Data-Driven System Monitoring for Space Operations

Modern space propulsion and exploration system designs are becoming increasingly sophisticated and complex. Determining the health state of these systems using traditional methods is becoming more difficult as the number of sensors and component interactions grows. Data-driven monitoring techniques have been developed to address these issues by analyzing system operations data to automatically characterize normal system behavior. The Inductive Monitoring System (IMS) is a data-driven system health monitoring software tool that has been successfully applied to several aerospace applications. IMS uses a data mining technique called clustering to analyze archived system data and characterize normal interactions between parameters. This characterization, or model, of nominal operation is stored in a knowledge base that can be used for real-time system monitoring or for analysis of archived events. Ongoing and developing IMS space operations applications include International Space Station flight control, satellite vehicle system health management, launch vehicle ground operations, and fleet supportability. As a common thread of discussion this paper will employ the evolution of the IMS data-driven technique as related to several Integrated Systems Health Management (ISHM) elements. Thematically, the projects listed will be used as case studies. The maturation of IMS via projects where it has been deployed, or is currently being integrated to aid in fault detection will be described. The paper will also explain how IMS can be used to complement a suite of other ISHM tools, providing initial fault detection support for diagnosis and recovery.

Satellites↗

Turning Limitations into Opportunities in the Development of the Orion Medical System: Incorporation of mHealth Devices

INTRODUCTION: Selection of medical devices for the Orion medical system is a complex task which is dependent on the current state of terrestrial technology. In this work we review the interplay between NASA requirements, constraints, and opportunities for synergy during the development of the Orion medical system. METHODS: The “plan to treat” list of conditions, and subsequently the medical resource list for the Orion Artemis II lunar flyby mission was completed using semi-quantitative methods. During this process, some medical resources were excluded to comply with mass and volume limits, while other resources applicable to multiple medical requirements were prioritized for inclusion. Choices were also examined considering NASA level of care standards for the Artemis design reference missions. As a means to optimize capabilities in spite of mass and volume constraints, ideas for integration of multiple devices into a single platform were explored, including a ‘hackathon’ challenge which was conducted to generate and evaluate concepts for combining medical devices into a single app-based mobile device (ultrasound, ECG, etc.). RESULTS: The Orion team identified 128 medical conditions that we “plan to treat”, with 139 unique medical resources to address these conditions, including 5 digital diagnostic devices (ECG, otoscope, stethoscope, pulse oximeter, and blood pressure monitor). During selection of these digital devices the team noted that miniaturized medical devices often use mobile device platforms (mHealth), some displaying and transmitting data exclusively via mobile device. Of the 5 initially selected devices, all are capable of mobile connection, one which cannot function without a mobile device (ECG). Furthermore, only one of these devices connects natively to a Windows platform, which is currently the only operating system available on Orion. DISCUSSION: Significant savings in mass and volume as well as training and usability improvements can be achieved by leveraging mHealth technologies. However, the platform presents significant challenges for deployment within the Artemis Program including lack of internet connectivity, incompatible operating systems, and radiation concerns. Each of these drawbacks are surmountable with investment in the supporting vehicle architecture, which may become necessary to support the technology trends seen in commercially available medical devices today. Objective: Learn about the opportunities and challenges of leveraging mHealth devices in the development of medical capabilities for austere environments. Learn about the constraints of the NASA spaceflight environment with regards to digital medical device integration.

Douglas Ebert↗

An Approach for Uncertainty Quantification and Management of Unmanned Aerial Vehicle Health

The increasing interest in low-altitude unmanned aerial vehicle (UAV) operations is bringing along safety concerns. Performance of small, low-cost UAVs drastically changes with type, size and controller of the vehicle. Their reliability is lower when compared to reliability of commercial aircrafts, and the availability of on-board sensors for health and state awareness is extremely limited due to their size and propulsion capabilities. Uncertainty plays a dominant role in such a scenario, where a variety of UAVs of different size, propulsion systems, dynamic performance and reliability enters the low-altitude airspace. Unexpected failures could have dangerous consequences for both equipment and humans within that same airspace. As a result, a number of research works and methodologies are being proposed in the area of UAV dynamic modeling, health and safety monitoring, but uncertainty quantification is rarely addressed. Thus, this paper pro- poses a perspective towards uncertainty quantification for autonomous systems, giving special emphasis to a UAV health monitoring application. A formal approach to classify uncertainty is presented; it is utilized to identify the uncertainty sources in UAVs health and operations, and then map uncertainty within a predictive process. To show the application of the methodology proposed here, the design of a model-based powertrain health monitoring algorithm for small-size UAVs is used as case study. The example illustrates how the uncertainty quantification approach can help the modeling strategy, as well as the assessment of diagnostic and prognostic performance.

Health Monitoring↗

Advanced imaging of the macrostructure and microstructure of bone

Noninvasive and/or nondestructive techniques are capable of providing more macro- or microstructural information about bone than standard bone densitometry. Although the latter provides important information about osteoporotic fracture risk, numerous studies indicate that bone strength is only partially explained by bone mineral density. Quantitative assessment of macro- and microstructural features may improve our ability to estimate bone strength. The methods available for quantitatively assessing macrostructure include (besides conventional radiographs) quantitative computed tomography (QCT) and volumetric quantitative computed tomography (vQCT). Methods for assessing microstructure of trabecular bone noninvasively and/or nondestructively include high-resolution computed tomography (hrCT), micro-computed tomography (muCT), high-resolution magnetic resonance (hrMR), and micromagnetic resonance (muMR). vQCT, hrCT and hrMR are generally applicable in vivo; muCT and muMR are principally applicable in vitro. Although considerable progress has been made in the noninvasive and/or nondestructive imaging of the macro- and microstructure of bone, considerable challenges and dilemmas remain. From a technical perspective, the balance between spatial resolution versus sampling size, or between signal-to-noise versus radiation dose or acquisition time, needs further consideration, as do the trade-offs between the complexity and expense of equipment and the availability and accessibility of the methods. The relative merits of in vitro imaging and its ultrahigh resolution but invasiveness versus those of in vivo imaging and its modest resolution but noninvasiveness also deserve careful attention. From a clinical perspective, the challenges for bone imaging include balancing the relative advantages of simple bone densitometry against the more complex architectural features of bone or, similarly, the deeper research requirements against the broader clinical needs. The considerable potential biological differences between the peripheral appendicular skeleton and the central axial skeleton have to be addressed further. Finally, the relative merits of these sophisticated imaging techniques have to be weighed with respect to their applications as diagnostic procedures requiring high accuracy or reliability on one hand and their monitoring applications requiring high precision or reproducibility on the other. Copyright 2000 S. Karger AG, Basel.

NASA Discipline Musculoskeletal↗

Software development for avionics SSME control and diagnostics

A study was made of software to integrate data from about 500 sensors that monitor the Space Shuttle Main Engine (SSME) and to make decisions for real-time control. Such software is expected to be applicable to other distributed systems as well. This study investigated the use of pattern recognition and other techniques to detect trends that could lead to major damage to the SSME and which would allow an orderly shutdown of the SSME before such damage could occur.

Choudry, A.↗

Autonomous System for Monitoring the Integrity of Composite Fan Housings

A low-cost and reliable system assesses the integrity of composite fan-containment structures. The system utilizes a network of miniature sensors integrated with the structure to scan the entire structural area for any impact events and resulting structural damage, and to monitor degradation due to usage. This system can be used to monitor all types of composite structures on aircraft and spacecraft, as well as automatically monitor in real time the location and extent of damage in the containment structures. This diagnostic information is passed to prognostic modeling that is being developed to utilize the information and provide input on the residual strength of the structure, and maintain a history of structural degradation during usage. The structural health-monitoring system would consist of three major components: (1) sensors and a sensor network, which is permanently bonded onto the structure being monitored; (2) integrated hardware; and (3) software to monitor in-situ the health condition of in-service structures.

Qing, Xinlin P.↗

The KATE shell: An implementation of model-based control, monitor and diagnosis

The conventional control and monitor software currently used by the Space Center for Space Shuttle processing has many limitations such as high maintenance costs, limited diagnostic capabilities and simulation support. These limitations have caused the development of a knowledge based (or model based) shell to generically control and monitor electro-mechanical systems. The knowledge base describes the system's structure and function and is used by a software shell to do real time constraints checking, low level control of components, diagnosis of detected faults, sensor validation, automatic generation of schematic diagrams and automatic recovery from failures. This approach is more versatile and more powerful than the conventional hard coded approach and offers many advantages over it, although, for systems which require high speed reaction times or aren't well understood, knowledge based control and monitor systems may not be appropriate.

Cornell, Matthew↗

Climsat rationale

We summarize reasons for the Climsat proposition; we also stress the need for certain climate monitoring other than that supplied by Climsat, especially solar irradiance, and we stress the complementarity of Climsat monitoring to plans for detailed EOS measurements. Existing and planned observations will not provide measurements of most climate forcing and feedback parameters with the accuracy needed to measure plausible decadal changes. Stratospheric water vapor and aerosol requirements are not met, for example, even though the present SAGE II instrument on the ERBS spacecraft measures those two parameters accurately, because ERBS is not expected to last more than a few years and it does not provide global coverage. We stress the imminence of a potential data gap even of those parameters, such as solar irradiance and stratospheric aerosols, for which monitoring capability has been proven and currently is in place. We find that most of the missing global climate forcings and feedbacks can be measured by three small instruments, which would need to be deployed on two spacecraft to obtain adequate sampling and global coverage. The monitoring must be maintained continuously for at least two decades. Such continuity can be attained by replacing a satellite after it fails, the functioning satellite providing calibration transfer to the new satellite. Certain complementary monitoring data are also needed, including solar monitoring from space, in order to fully meet requirements for monitoring all the climate forcings and feedbacks. The complementary data needs are discussed toward the end of this section. We summarize the proposed Climsat measurements and compare the expected accuracies to those which are needed to analyze changes of the global thermal energy cycle on decadal time scales. We stress the need to get broader participation of the scientific community in the monitoring and analysis activity. Finally, we discuss related climate process and diagnostic measurements.

Hansen, James↗

Dynamic Light Scattering of Diabetic Vitreopathy

Diabetes induces pathology throughout the body via nonenzymatic glycation of proteins. Vitreous, which is replete with type 11 collagen, undergoes significant changes in diabetes. The resultant diabetic vitreopathy plays an important role in diabetic retinopathy. Detecting these molecular changes could provide insight into diabetic eye disease as well as molecular effects elsewhere in the body. Human eyes were obtained at autopsy and studied in the fresh, unfixed state. Sclera, choroid, and retina were dissected off the vitreous for dark-field slit microscopy and dynamic light scattering (DLS). For the former, the entire vitreous was exposed. For the latter, only a window at the equator was dissected in some specimens, and the anterior segment was removed leaving the posterior lens capsule intact in others. DLS was performed to determine particle sizes at multiple sites 0.5 mm apart, spanning the globe at the equator (window dissections) and along the antero-posterior axis. Dark-field slit microscopy in diabetic subjects detected findings typical of age-related vitreous degeneration, but at much younger ages than nondiabetic controls. Noninvasive DLS measurements found a greater heterogeneity and larger particle sizes in vitreous of subjects with diabetes as compared to age-matched controls. DLS can detect and quantify the early molecular effects that cause vitreous collagen fibrils to cross-link and aggregate. This could provide valuable insight into ocular and systemic effects of hyperglycemia, because the molecular changes in diabetic vitreopathy could serve as an index of such effects throughout the body. In addition to the diagnostic implications, this methodology could provide a rapid, reproducible way to monitor the response to therapy with novel agents intended to prevent the complications of diabetes on a molecular level.

Sebag, J.↗

A National Program for Analysis of the Climate System

Perhaps the single greatest roadblock to fundamental advances in our understanding of climate variability and climate change is the lack of robust and unbiased long-term global observations of the climate system. Such observations are critical for the identification and diagnosis of climate variations, and provide the constraints necessary for developing and validating climate models. The first generation of reanalysis efforts, by using fixed analysis systems, eliminated the artificial climate signals that occurred in analyses generated at the operational numerical weather prediction centers. These datasets are now widely used by the scientific community in a variety of applications including atmosphere-ocean interactions, seasonal prediction, climate monitoring, the hydrological cycle, and a host of regional and other diagnostic studies. These reanalyses, however, had problems that made them sub-optimal or even unusable for some applications. Perhaps the most serious problem for climate applications was that, while the assimilation system remained fixed, changes in the observing systems did produce spurious changes in the perceived climate. The first generation reanalysis products also exposed problems with physical consistency of the products and the accurate representation of physical processes in the climate system. Examples are bias in the estimates of ocean surface fluxes, and inadequate representation of polar hydrology. In this talk, I will describe some initial plans for a national program on reananlysis. The program is envisioned to be part of an on-going activity to maintain, improve, and reprocess our record of climate observations. I will discuss various issues affecting the quality of reanalyses, with a special focus on those relevant to the ocean.

Schubert, Siegfried↗

Health-Enabled Smart Sensor Fusion Technology

A process was designed to fuse data from multiple sensors in order to make a more accurate estimation of the environment and overall health in an intelligent rocket test facility (IRTF), to provide reliable, high-confidence measurements for a variety of propulsion test articles. The object of the technology is to provide sensor fusion based on a distributed architecture. Specifically, the fusion technology is intended to succeed in providing health condition monitoring capability at the intelligent transceiver, such as RF signal strength, battery reading, computing resource monitoring, and sensor data reading. The technology also provides analytic and diagnostic intelligence at the intelligent transceiver, enhancing the IEEE 1451.x-based standard for sensor data management and distributions, as well as providing appropriate communications protocols to enable complex interactions to support timely and high-quality flow of information among the system elements.

Wang, Ray↗

An Oculometric Standard to Assess the Performance of the Ocular System for Long Duration Spaceflight

Changes in the human brain, due to spaceflight, have been a challenge to the space program since its inception; a challenge that is becoming more acute as extended International Space Station (ISS) missions become routine, a return to crewed lunar exploration is about to begin, and a multi-year crewed trip to Mars is being planned. Determining the extent to which neurophysiological adaptations may adversely impact performance in operational tasks, assessing the full-time course of these changes, and identifying/mitigating any potential long-term health consequences are crucial steps required to enable safe crew-autonomous, long-duration, deep-space missions. Vision is the predominant perceptual sense used to guide cognition and motor control in humans. Thus, it is critical for the success of any future, long-duration mission to understand how long-term exposure to microgravity and to other stressors of spaceflight and their interactions, impact visual function. This is an especially challenging task given the small and disparate samples from which we have been and will be able to collect human performance data. NASA has recently been carefully tracking spaceflight-induced ophthalmic changes, driven in large part by the fluid shifts related to microgravity. In particular, a recent study of Optical Coherence Tomography (OCT) postflight measures revealed that more than two-thirds of US crew members experience significant increases in retinal thickness after 6month or longer ISS missions. Space Associated Neuro-ocular Syndrome (SANS) also includes visual acuity decrements and other ocular structural changes that could adversely impact in-flight performance as missions become longer. However, the impact of spaceflight on the visual system is not limited to the retina. Recent comparisons of pre-and post-flight brain images have revealed structural changes throughout the brain that implicate visual, visuomotor, and visual-cognitive pathways, consistent with observed functional impacts (e.g., decreased speed/accuracy/timing of fine goal-oriented movements). Current limitations on inflight testing make it very difficult to determine when and under what conditions SANS and other disruptions of human neurological subsystems arise. Currently, one cannot anticipate the time course and extent of impairment and recovery. This study addresses this knowledge gap by creating an integrated framework of the relevant existing literature on visual and oculomotor function during spaceflight with an eye towards complementing current structural measures of visuomotor impairment with new oculometric standard measures. Using eye-movement based visual function assessment and diagnostics would provide a valuable enhancement of crew health and performance monitoring in support of deepspace exploration.

Vision↗