Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical Interferometer”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Fabry-Perot interferometers as narrow band optical filters.

We have constructed solid Fabry-Perot narrow-band filters that can be used in systems having one arc second or better resolution. Our filters operate at H-alpha, have a three-inch aperture, and typical transmission of 70 per cent. However, the same technology can be applied to construction of filters as narrow as 0.05 A at any wavelength from 4200 to 11000 A.

Title, A. M.↗

Multimode fiber-optic broad spectral band interferometer

An interferometric technique for observing white light fringes on a mode-by-mode basis in long lengths of few-mode fiber is described. Each mode can be used as a separate channel with negligible cross talk from other modes because of the highly localized nature of interference. The spatial-mode separation technique makes it possible to observe the interference fringes without loss of visibility caused by multimode overlap effects. The high-contrast, broadband fringes observed in the multimode interference experiments indicate that a multimode fiber is capable of maintaining the coherence of injected light well beyond the point where intermodal path differences exceed the temporal coherence length.

Shaklan, S.↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗

Radio frequency passband signal generation using photonics

Devices, methods and systems for generating wideband, high-fidelity arbitrary radio frequency (RF) passband signals are described. A voltage tunable optical filter for arbitrary RF passband signal generation includes a first input configured to receive a broadband optical pulse train, a second input configured to receive a first control voltage representative of an amplitude signal, an electrooptic modulator to receive the broadband optical pulse train and the first control voltage, to modulate the broadband optical pulse train in accordance with the amplitude signal, and to produce two complementary optical outputs that form two arms of an interferometer, an optical delay component to impart an optical path difference into one of the complementary outputs of the electrooptic modulator, and a combiner or a splitter to receive two complementary optical outputs of the electrooptic modulator after impartation of the optical path difference and to produce an output interference pattern of fringes.

Gowda, Apurva Shantharaj↗

Fiber-Optic Temperature Sensor Using a Thin-Film Fabry-Perot Interferometer

A fiber-optic temperature sensor was developed that is rugged, compact, stable, and can be inexpensively fabricated. This thin-film interferometric temperature sensor was shown to be capable of providing a +/- 2 C accuracy over the range of -55 to 275 C, throughout a 5000 hr operating life. A temperature-sensitive thin-film Fabry-Perot interferometer can be deposited directly onto the end of a multimode optical fiber. This batch-fabricatable sensor can be manufactured at a much lower cost than can a presently available sensor, which requires the mechanical attachment of a Fabry-Perot interferometer to a fiber. The principal disadvantage of the thin-film sensor is its inherent instability, due to the low processing temperatures that must be used to prevent degradation of the optical fiber's buffer coating. The design of the stable thin-film temperature sensor considered the potential sources of both short and long term drifts. The temperature- sensitive Fabry-Perot interferometer was a silicon film with a thickness of approx. 2 microns. A laser-annealing process was developed which crystallized the silicon film without damaging the optical fiber. The silicon film was encapsulated with a thin layer of Si3N4 over coated with aluminum. Crystallization of the silicon and its encapsulation with a highly stable, impermeable thin-film structure were essential steps in producing a sensor with the required long-term stability.

Beheim, Glenn↗

Phase Stable RF-over-fiber Transmission using Heterodyne Interferometry

New scientific applications require phase-stabilized RF distribution to multiple remote locations. These include phased-array radio telescopes and short pulse free electron lasers. RF modulated onto a CW optical carrier and transmitted via fiber is capable of low noise, but commercially available systems aren't long term stable enough for these applications. Typical requirements are for less than 50fs long term temporal stability between receivers, which is 0.05 degrees at 3GHz. Good results have been demonstrated for RF distribution schemes based on transmission of short pulses, but these require specialized free-space optics and high stability mechanical infrastructure. We report a method which uses only standard telecom optical and RF components, and achieves less than 20fs RMS error over 300m of standard single-mode fiber. We demonstrate stable transmission of 3GHz over 300m of fiber with less than 0.017 degree (17fs) RMS phase error. An interferometer measures optical phase delay, providing information to a feed-forward correction of RF phase.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System and method of phase-locked fiber interferometry

A system and method are provided for optical homodyne detection in an optical fiber interferometer. A detection signal is obtained by interfering an optical data signal with a phase-modulated optical reference signal. The modulator for the optical reference signal is phase-locked to an oscillatory modulation waveform. In embodiments, the modulator includes a piezoelectric element. In more specific embodiments, the modulator is a piezoelectric optical fiber-stretcher.

Katzenmeyer, Aaron Michael↗

Measurement of birefringence of optical materials using a wedged plate interferometer

A nondestructive technique for measuring the birefringence of optical materials such as calcite using wedged plate interferometer is presented. The sample needed for measuring the refractive index must be polished in the form of a parallel plate. The method is based on the measurement of the longitudinal displacement of the focus when the parallel plate is inserted in a converging beam of light. The displacement of the focus is a measure of the refractive index of the optical material. In the case of a uniaxial crystal, the displacement of the focus for the extraordinary ray is different from the displacement of the focus for the ordinary ray. Hence the birefringence of the crystal is determined by measuring the difference between the two focii. It is possible to obtain an accuracy up to 0.0002 in the measurement of birefringence depending on the sample thickness. The method should find its application for the characterization of new crystals in various material research and crystal growth laboratories.

Shukla, R. P.↗

Development and implementation of a portable grating interferometer system as a standard tool for testing optics at the Advanced Photon Source beamline 1-BM

We developed a portable X-ray grating interferometer setup as a standard tool for testing optics at the Advanced Photon Source (APS) beamline 1-BM. The interferometer can be operated in phase-stepping, Moiré, or single-grating harmonic imaging mode with 1-D or 2-D gratings. All of the interferometer motions are motorized; hence, it is much easier and quicker to switch between the different modes of operation. A novel aspect of this new instrument is its designed portability. While the setup is designed to be primarily used as a standard tool for testing optics at 1-BM, it could be potentially deployed at other APS beamlines for beam coherence and wavefront characterization or imaging. Herein, the design of the interferometer system is described in detail and coherence measurements obtained at the APS 34-ID-E beamline are presented. The coherence was probed in two directions using a 2-D checkerboard, a linear, and a circular grating at X-ray energies of 8 keV, 11 keV, and 18 keV.

47 OTHER INSTRUMENTATION↗

Highly stable polarization independent Mach-Zehnder interferometer

We experimentally demonstrate optical Mach-Zehnder interferometer utilizing displaced Sagnac configuration to enhance its phase stability. The interferometer with footprint of 27×40 cm offers individually accessible paths and shows phase deviation less than 0.4° during a 250 s long measurement. The phase drift, evaluated by means of Allan deviation, stays below 3° or 7 nm for 1.5 h without any active stabilization. The polarization insensitive design is verified by measuring interference visibility as a function of input polarization. For both interferometer's output ports and all tested polarization states the visibility stays above 93%. The discrepancy in visibility for horizontal and vertical polarization about 3.5% is caused mainly by undesired polarization dependence of splitting ratio of the beam splitter used. The presented interferometer device is suitable for quantum-information and other sensitive applications where active stabilization is complicated and common-mode interferometer is not an option as both the interferometer arms have to be accessible individually.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Spatially translatable optical fiber-coupled heterodyne interferometer

An interferometer is a useful diagnostic tool for measuring line-averaged electron density but is limited in its use because it generally measures at a fixed location. Here, we report here a spatially translatable fiber-coupled interferometer that measures the density of a high-speed MHD-driven plasma jet colliding with a target cloud. The interferometer uses a He–Ne laser coupled to a polarization-maintaining single mode optical fiber having a vacuum feedthrough. Lastly, the interferometer provides a measure of the spatial-temporal profile of the line-averaged electron density from which the change in jet velocity as a result of its collision with the target cloud can be deduced.

47 OTHER INSTRUMENTATION↗

Fresnel drag effect in fiber optic gyroscope

Consideration is given to the development of a low-noise fiber-optic ring interferometer gyroscope. A technique for measuring the Fresnel drag coefficient of optical fibers is described, and the accuracy of the technique is considered. An experiment is performed which allows verification of the Einstein velocity addition theorem to the first nonlinear term. An experimental setup for measuring Fresnel drag is described: it consists of a Sagnac interferometer and a Fresnel drag measurement configuration.

Vali, V.↗

At-wavelength characterization of refractive x-ray lenses using a two-dimensional grating interferometer

We report on the application of a two-dimensional hard x-ray grating interferometer to x-ray optics metrology. The interferometer is sensitive to refraction angles in two perpendicular directions with a precision of 10 nrad. It is used to observe the wavefront changes induced by a single parabolic beryllium focusing lens of large radius of curvature. The lens shape is reconstructed and its residual aberrations are analyzed. Its profile differs from an ideal parabolic shape by less than 2 {mu}m or {lambda}/50 at {lambda} = 0.54 A wavelength.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Optical astronomical interferometry - Requirements on stellar Michelson interferometry and heterodyne interferometry for high-resolution imaging

The requirements for optical path compensation on space-based (no atmospheric-induced disturbance) heterodyne interferometers and generalized Michelson stellar interferometers are developed. It is demonstrated that heterodyne interferometers require optical path compensation to well within the coherence length dictated by its bandwidth, while Michelson stellar interferometers require compensation to a fraction of their utilized wavelength.

Silverglate, P. R.↗

Sensitivity of a fibre scattered-light interferometer to external phase perturbations in an optical fibre

Sensitivity of a fibre scattered-light interferometer to external phase perturbations is studied for the first time. An expression is derived for an average power of a useful signal at the interferometer output under external harmonic perturbations in a signal fibre of the interferometer. It is shown that the maximum sensitivity of the scattered-light interferometer depends on the dispersion of the interferogram intensity. An average signal-to-noise ratio is determined theoretically and experimentally at the output of the interferometer at different amplitudes of external perturbations. Using the measured dependences of the signal-to-noise ratio, the threshold sensitivity of the fibre scattered-light interferometer to external phase perturbations is found. The results obtained can be used to optimise characteristics of optical time-domain reflectometers and to design individual phase-sensitive fibre-optic sensors. (laser applications and other topics in quantum electronics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Properties of an ultrafast all-optical switching window in an integrated silicon-based Mach - Zehnder interferometer

An ultrafast all-optical switch based on the integrated Mach - Zehnder interferometer (MZI) with two arms consisting of identical silicon-on-insulator (SOI) optical waveguides is presented. The operability of the presented interferometer is simulated both for the continue wave (cw) and pulsed probe signals. It is shown that at the output port of the MZI, the switching window of the probe signal is strongly dependent on the energy and duration of the ultrafast control pulse and the SOI waveguide length. In addition, the initial delay time between both two optical waves will significantly affect the optical switching window when a pulsed probe signal wave is used. (integrated optics)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear Control of the Optical Delay Line Pathlength

This paper discusses the problem of designing a control system for an interferometer delay line which contains coarse-vernier loops. The vernier loop compensator has nonlinear dynamics and includes a local feedback path containing a deadzone.

nonlinear↗

Nonlinear optical processing with Fabry-Perot interferometers containing phase recording media

New techniques in nonlinear optical processing are explored, based on the operation of intensity level selection as performed by a Fabry-Perot interferometer containing a phase object. The image being processed is recorded on a medium between the mirrors as a spatially varying phase shift less than pi. The interferometer only transmits light through those portions of the object that corresponds to a single value of the phase and hence to a single intensity level in the input. More complicated operations such as thresholding and analog-to-digital conversion are performed by modulating the light source as the different levels are selected. Photoresist and lithium niobate have been used as phase objects, and experimental data for both are presented. Three kinds of Fabry-Perot interferometers have been used to demonstrate nonlinear processing using coherent and incoherent light. Color images have been produced with black and white inputs and white light illumination.

Bartholomew, B. J.↗