Search NASA⌕ Search

SEARCH · Search NASA

Results for “optical sources”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Far-ultravoilet and optical spectrscopy of the detached white dwarf-M binary RE J1629+780

We present optical and far-ultraviolet observations, including IUE high- and low-dispersion spectroscopy, of the (DA2+dM4-5) close binary, RE J1629+780, a very bright ROSAT EUV source. The optical data reveal emission reversals in the cores of the Balmer lines, which vary in strength but reveal no evidence of wavelength shifts reflecting orbital motion, suggesting that the red dwarf and the white dwarf are widely separated. Thus it is unlikely that irradiation plays a dominant role in the activity of the red dwarf. One dramatic increase in the intensity of the H-beta emission strength in the course of one hour indicates that the observed intensity variations are most likely related to flare activity on the red dwarf. Our analysis of Balmer and Lyman alpha features yield T(sub eff) = 42,500 +/- 1300 K and log g = 7.6 +/- 0.3 for the DA2 white dwarf, which is consistent with the overall 900 to 3200 A energy distribution derived from Voyager and IUE low-dispersion spectra. Our analysis of three IUE echelle spectra reveal numerous lines of interstellar origin. Using a total of 13 interstellar matter (ISM) features we find a mean radial velocity of -13.57 +/- 1.66 km/s for the interstellar features. However, we found no evidence of trace metal absorbers levitated or accreted in the white-dwarf photosphere nor any evidence of circumstellar or wind features. We estimate a lower limit hydrogen layer mass of 2.1 x 10(exp -15) solar mass for a stratified atmosphere based upon the nondetection of He II (1640). Tighter constraints on the helium abundance and the hydrogen layer mass, from EUV and X-ray data, are presented for both homogeneous and stratified atmospheric configurations.

Sion, Edward M.↗

Discrete Wavelength-Locked External Cavity Laser

A prototype improved external cavity laser (ECL) was demonstrated in the second phase of a continuing effort to develop wavelength-agile lasers for fiber-optic communications and trace-gas-sensing applications. This laser is designed to offer next-generation performance for incorporation into fiber-optic networks. By eliminating several optical components and simplifying others used in prior designs, the design of this laser reduces costs, making lasers of this type very competitive in a price-sensitive market. Diode lasers have become enabling devices for fiber optic networks because of their cost, compactness, and spectral properties. ECLs built around diode laser gain elements further enhance capabilities by virtue of their excellent spectral properties with significantly increased (relative to prior lasers) wavelength tuning ranges. It is essential to exploit the increased spectral coverage of ECLs while simultaneously insuring that they operate only at precisely defined communication channels (wavelengths). Heretofore, this requirement has typically been satisfied through incorporation of add-in optical components that lock the ECL output wavelengths to these specific channels. Such add-in components contribute substantially to the costs of ECL lasers to be used as sources for optical communication networks. Furthermore, the optical alignment of these components, needed to attain the required wavelength precision, is a non-trivial task and can contribute substantially to production costs. The design of the present improved ECL differs significantly from the designs of prior ECLs. The present design relies on inherent features of components already included within an ECL, with slight modifications so that these components perform their normal functions while simultaneously effecting locking to the required discrete wavelengths. Hence, add-in optical components and the associated cost of alignment can be eliminated. The figure shows the locking feedback signal, and the frequency locking achieved by use of this signal, as a mirror is tilted through a range of angles to tune the ECL through 48 channels. The data for the frequency plot were obtained, simultaneously with the data for the locking-signal plot, by using a scanning Michelson interferometer to precisely determine the ECL wavelength (and, hence, frequency). Given the ability of the Michelson interferometer to obtain highly precise readings, the frequency plot can be taken to be a reliable indication of single-mode operation. The discontinuities in the frequency plot signify the switching of the ECL between channels; in other words, they indicate tuning with locking to discrete frequencies. The peaks of the feedbacklocking signal correspond to the centers, or near centers, of the mirror angle scan through the corresponding channels. Thus, it is clear that when the feedback-locking signal is at a local maximum, the ECL is operating at single frequency at or near the middle frequency of the selected channel. This is all that is required for precisely locking the ECL output wavelength. The locking is achieved without additional external optical components.

Pilgrim, Jeffrey S.↗

Jets, mass outflows and disks associated with young stellar objects

Over the past 3 years, a series was obtained of the CCD images of regions surrounding young stellar objects (YSO's) located in a variety of environments with the goal of providing a census of the properties of mass outflows associated these objects. A catalog describing the optical morphology and kinematics of 38 mass outflows associated with young stellar objects (YSOs) was completed. The direct detection was reported of disks surrounding HL Tau and LI551/IRS 5 -- both sources of optical jets and large-scale mass outflows. In each case, the disk dimensions are on the order of several hundred astronomical units and the disk dust masses approximately 10 to the -7th power solar masses. A program aimed at indirect detection of circumstellar disks associated with YSOs was started. The technique involves comparison of an observed bolometric luminosity (L(bol)) with an independent measure of the true luminosity (L(spec)) of a YSO which derives from the observed strengths of surface-gravity-sensitive spectral features.

Strom, S. E.↗

AWG Filter for Wavelength Interrogator

A wavelength interrogator is coupled to a circulator which couples optical energy from a broadband source to an optical fiber having a plurality of sensors, each sensor reflecting optical energy at a unique wavelength and directing the reflected optical energy to an AWG. The AWG has a detector coupled to each output, and the reflected optical energy from each grating is coupled to the skirt edge response of the AWG such that the adjacent channel responses form a complementary pair response. The complementary pair response is used to convert an AWG skirt response to a wavelength.

Black, Richard J.↗

Optical constants in the extreme ultraviolet and soft X-ray region

The nature of optical constants and their measurement by reflection or absorption techniques in the extreme ultraviolet and soft X-ray spectral region from 30 to 3000 eV is discussed with emphasis on mirror design. Sources of optical constant data are mentioned and reflectance measurements for SiC and Kanigen between 40 and 200 eV are reported.

Rife, J. C.↗

A search for optical flashes from the 'Perseus Flasher'

The results of an extended search for short-timescale optical flashes from a four square-degree area centered on the coordinates of the Perseus Flasher are reported. The photographed optical flash was of brightness mB = -1.7 and had a duration of roughly 0.5 s. In 70 hours of observation no celestial optical flashes were detected in the region of the Perseus Flasher to a limiting magnitude of 7.1 for a one-second flash. Neither X-ray nor optical flashes were seen. A survey of archived photographic images of the Perseus Flasher revealed no optical transients in over 700 hours of total exposure time to a limiting magnitude of mB about 4-5 for a one-second flash. Based on the ETC data base, possible terrestrial sources of optical flashes which might account for the phenomenon are discussed.

Vanderspek, Roland K.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

Novel approaches to the construction of miniaturized analytical instrumentation

This paper focuses on the design, construction, preliminary testing, and potential applications of three forms of miniaturized analytical instrumentation. The first is an optical fiber instrument for monitoring pH and other cations in aqueous solutions. The instrument couples chemically selective indicators that were immobilized at porous polymeric films with a hardware package that provides the excitation light source, required optical components, and detection and data processing hardware. The second is a new form of a piezoelectric mass sensor. The sensor was fabricated by the deposition of a thin (5.5 micron) film of piezoelectric aluminum nitride (AIN). The completed deposition process yields a thin film resonator (TFR) that is shaped as a 400 micron square and supports a standing bulk acoustic wave in a longitudinal mode at frequencies of approx. 1 GHz. Various deposition and vapor sorption studies indicate that the mass sensitivity of the TFR's rival those of the most sensitive mass sensors currently available, though offering such performance in a markedly smaller device. The third couples a novel form of liquid chromatography with microlithographic miniaturization techniques. The status of the miniaturization effort, the goal of which is to achieve chip-scale separations, is briefly discussed.

Porter, Marc D.↗

VerSoX B07-B: a high-throughput XPS and ambient pressure NEXAFS beamline at Diamond Light Source

The beamline optics and endstations at branch B of the Versatile Soft X-ray (VerSoX) beamline B07 at Diamond Light Source are described. B07-B provides medium-flux X-rays in the range 45-2200 eV from a bending magnet source, giving access to local electronic structure for atoms of all elements from Li to Y. It has an endstation for high-throughput X-ray photoelectron spectroscopy (XPS) and near-edge X-ray absorption fine-structure (NEXAFS) measurements under ultrahigh-vacuum (UHV) conditions. B07-B has a second endstation dedicated to NEXAFS at pressures from UHV to ambient pressure (1 atm). The combination of these endstations permits studies of a wide range of interfaces and materials. The beamline and endstation designs are discussed in detail, as well as their performance and the commissioning process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Directional spectral emissivity measurement system

Apparatus and process for determining the emissivity of a test specimen including an integrated sphere having two concentric walls with a coolant circulating therebetween, and disposed within a chamber which may be under ambient, vacuum or inert gas conditions. A reference sample is disposed within the sphere with a monochromatic light source in optical alignment therewith. A pyrometer is in optical alignment with the test sample for obtaining continuous test sample temperature measurements during a test. An arcuate slit port is provided through the spaced concentric walls of the integrating sphere with a movable monochromatic light source extending through and movable along the arcuate slit port. A detector system extends through the integrating sphere for continuously detecting an integrated signal indicative of all radiation within its field of view, as a function of the emissivity of the test specimen at various temperatures and various angle position of the monochromatic light source. A furnace for heating the test sample to approximately 3000 K. and control mechanism for transferring the heated sample from the furnace to the test sample port in the integrating sphere is also contained within the chamber.

Halyo, Nesim↗

A Wolter type I LAMAR

Observational objectives for the LAMAR and their influence on the instrument design are discussed. It is concluded that the most important design parameter is the angular resolution of the LAMAR modules since it so strongly influences sensitivity, optical identifications, source confusion, spectral resolution for objective gratings and the ability to resolve small extended sources. A high resolution Wolter Type I LAMAR module is described, its hardware status discussed, and the performance of a LAMAR observatory presented. A promising technique for enhancing the reflectivity of Wolter Type I X-ray optics in a selected bandpass at high energy has been investigated and the performance of the LAMAR module, utilizing this method, has been calculated.

Catura, R. C.↗

A 3-s delay in an optical burst from X-ray burst source MXB1735-44

Analysis of the arrival times of X-ray and optical bursts from the X-ray burst source MXB1735-44 shows that the onset of one optical burst was delayed 2.8 sec with respect to the X-ray burst. Observations of the pulses are accurate to less than or equal to five ms. The delay in the optical pulse may be attributed to light travel time in the system and/or the time needed to reprocess X-rays into light.

Mcclintock, J. E.↗

Relativistic jets and the continuum emission in QSOs

The radio through optical, and possibly X-ray, emission of QSOs and active galactic nuclei is analytically interpreted in terms of a relativistic jet containing high-energy particles and a magnetic field. Parallel to the jet axis, a strong, compact radio source and strongly polarized radiation are detected, while larger viewing angles relative to the jet axis result in spectral dominance by the central region containing the 'energy machine' which drives the energy flux in the jet. It is shown that the relativistic jet model can explain the association of OVVs with strong, variable radio sources, strong optical polarization, and continuity of the radio to optical spectra.

Marscher, A. P.↗

The hidden nuclear spectrum of the luminous IRAS source FSC 10214+4724

Optical spectropolarimetry of the luminous IRAS source FSC 10214+4724 (z=2.286) reveals that the strong (approximately 17%) linear polarization detected by Lawrence et al. is shared by both the narrow ultraviolet (UV) emission lines and the underlying continuum. This observation and the brightness of the source rule out synchrotron emission and dichroic extinction by dust as the polarizing mechanism, leaving scattering as the only plausible cause of the polarized emission. The narrowness of the lines requires that the scatterers be dust grains or cool (below 1.6 x 10(exp 4) K) electrons. We can recover the spectrum that is incident on the scattering medium provided we make some reasonable assumptions regarding the source geometry. The scattered UV spectrum has a power-law index alpha of -1.2 plus or minus 0.6 (F(sub nu) varies as nu(sup alpha)), steeper than would be expected from a young burst of star formation but similar to that of many active galactic nucleus (AGNs).

Jannuzi, Buell T.↗

Non-invasive Optical End-to-End Test of a Large TMA Telescope (JWST) from the Intermediate Focus

The James Webb Space Telescope (JWST) requires testing of the full optical system in a cryogenic vacuum environment before launch. Challenges with the telescope architecture and the test environment lead to placing removable optical test sources at the Cassegrain intermediate focus of the Telescope. The Science Instrument suite will be used to align the telescope and to verify the wavefront error. The Science Instruments capture test images that are analyzed using focus diverse phase retrieval. The wavefront sensing algorithms have the large dynamic range required to measure the relatively small wavefronts of interest in the presence of the large aberrations resulting from the off-axis source locations at the intermediate focus. These inherent aberrations of the off-axis design are removed analytically from the measured data. The test design and in-situ wavefront sensing process enables a number of tests to verify the alignment and optical quality of the system.

Whitman, Tony↗

Computational optical physical unclonable function

A system or method for encryption of data includes a light source, a random optical element and a light detection element. The light source is arranged to transmit an input data signal to the random optical element. The light source is incident on the random optical element such that the input data signal is randomly scattered by the random optical element to generate an image at on the detector disposed at an output of the random optical element. The image received by the detector is applied to a compressive sensing algorithm to generate a transfer function. The transfer function defines a relationship between the input data signal and the image to enable estimation and reconstruction of the input data signal.

Birch, Gabriel Carlisle↗

Ion-Atom Cold Collisions and Atomic Clocks

Collisions between ultracold neutral atoms have for some time been the subject of investigation, initially with hydrogen and more recently with laser cooled alkali atoms. Advances in laser cooling and trapping of neutral atoms in a Magneto-Optic Trap (MOT) have made cold atoms available as the starting point for many laser cooled atomic physics investigations. The most spectacularly successful of these, the observation of Bose-Einstein Condensation (BEC) in a dilute ultra-cold spin polarized atomic vapor, has accelerated the study of cold collisions. Experimental and theoretical studies of BEC and the long range interaction between cold alkali atoms is at the boundary of atomic and low temperature physics. Such studies have been difficult and would not have been possible without the development and advancement of laser cooling and trapping of neutral atoms. By contrast, ion-atom interactions at low temperature, also very difficult to study prior to modern day laser cooling, have remained largely unexplored. But now, many laboratories worldwide have almost routine access to cold neutral atoms. The combined technologies of ion trapping, together with laser cooling of neutrals has made these studies experimentally feasible and several very important, novel applications might come out of such investigations . This paper is an investigation of ion-atom interactions in the cold and ultra-cold temperature regime. Some of the collisional ion-atom interactions present at room temperature are very much reduced in the low temperature regime. Reaction rates for charge transfer between unlike atoms, A + B(+) approaches A(+) + B, are expected to fall rapidly with temperature, approximately as T(sup 5/2). Thus, cold mixtures of atoms and ions are expected to coexist for very long times, unlike room temperature mixtures of the same ion-atom combination. Thus, it seems feasible to cool ions via collisions with laser cooled atoms. Many of the conventional collisional interactions, exploited as a useful tool at room temperature and higher, are greatly enhanced at low energy. For example, collisional spin transfer from one species of polarized atoms to another has long been a useful method for polarizing a sample of atoms where no other means was available. Because optical pumping cannot be used to polarize the nuclear spin of Xe-129 or He-3 (for use in nmr imaging of the lungs), the nuclear spins are polarized via collisions with an optically pumped Rb vapor in a cell containing both gases. In another case, a spin polarized thermal Cs beam was used to polarize the hyperfine states of trapped He(+)-3 ions in order to measure their hyperfine clock transition frequency. The absence of an x-ray light source to optically pump the ground state of the He(+)-3 ion necessitated this alternative state preparation. Similarly, Cd(+) and Sr(+) ions were spin-oriented via collisions in a cell with optically pumped Rb vapor. Resonant RF spin changing transitions in the ground state of the ions were detected by changes in the Rb resonance light absorption. Because cold collision spin exchange rates scale with temperature as T(sup -1/2) this technique is expected to be a far more powerful tool than the room temperature counterpart. This factor of 100 or more enhancement in spin exchange reaction rates at low temperatures is the basis for a novel trapped ion clock where laser cooled neutrals will cool, state select and monitor the ion clock transition. The advantage over conventional direct laser cooling of trapped ions is that the very expensive and cumbersome UV laser light sources, required to excite the ionic cooling transition, are effectively replaced by simple diode lasers.

Prestage, John D.↗