Search NASA⌕ Search

SEARCH · Search NASA

Results for “outlier detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

283 records · Page 16

IN-SYNC. III. THE DYNAMICAL STATE OF IC 348—A SUPER-VIRIAL VELOCITY DISPERSION AND A PUZZLING SIGN OF CONVERGENCE

Most field stars will have encountered the highest stellar density and hence the largest number of interactions in their birth environment. Yet the stellar dynamics during this crucial phase are poorly understood. Here we analyze the radial velocities measured for 152 out of 380 observed stars in the 2–6 Myr old star cluster IC 348 as part of the SDSS-III APOGEE. The radial velocity distribution of these stars is fitted with one or two Gaussians, convolved with the measurement uncertainties including binary orbital motions. Including a second Gaussian improves the fit; the high-velocity outliers that are best fit by this second component may either (1) be contaminants from the nearby Perseus OB2 association, (2) be a halo of ejected or dispersing stars from IC 348, or (3) reflect that IC 348 has not relaxed to a Gaussian velocity distribution. We measure a velocity dispersion for IC 348 of 0.72 ± 0.07 km s{sup −1} (or 0.64 ± 0.08 km s{sup −1} if two Gaussians are fitted), which implies a supervirial state, unless the gas contributes more to the gravitational potential than expected. No evidence is found for a dependence of this velocity dispersion on distance from the cluster center or stellar mass. We also find that stars with lower extinction (in the front of the cloud) tend to be redshifted compared with stars with somewhat higher extinction (toward the back of the cloud). This data suggest that the stars in IC 348 are converging along the line of sight. We show that this correlation between radial velocity and extinction is unlikely to be spuriously caused by the small cluster rotation of 0.024 ± 0.013 km s{sup −1} arcmin{sup −1} or by correlations between the radial velocities of neighboring stars. This signature, if confirmed, will be the first detection of line of sight convergence in a star cluster. Possible scenarios for reconciling this convergence with IC 348's observed supervirial state include: (a) the cluster is fluctuating around a new virial equilibrium after a recent disruption due to gas expulsion or a merger event, or (b) the population we identify as IC 348 results from the chance alignment of two sub-clusters converging along the line of sight. Additional measurements of tangential and radial velocities in IC 348 will be important for clarifying the dynamics of this region and informing models of the formation and evolution of star clusters. The radial velocities analyzed in this paper have been made available online.

79 ASTRONOMY AND ASTROPHYSICS↗

WE-AB-BRA-07: Operating Room Quality Assurance (ORQA) for Spine Surgery Using Known-Component 3D-2D Image Registration

Purpose: Intraoperative x-ray radiography/fluoroscopy is commonly used to qualitatively assess delivery of surgical devices (e.g., spine pedicle screws) but can fail to reliably detect suboptimal placement (e.g., breach of adjacent critical structures). We present a method wherein prior knowledge of the patient and surgical components is leveraged to match preoperative CT and intraoperative radiographs for quantitative assessment of 3D pose. The method presents a new means of operating room quantitative quality assurance (ORQA) that could improve quality and safety, and reduce the frequency of revision surgeries. Methods: The algorithm (known-component registration, KC-Reg) uses patient-specific preoperative CT and parametrically defined surgical component models within a robust 3D-2D registration method to iteratively optimize gradient similarity using the covariance matrix adaptation evolution strategy. Advances from previous work address key challenges to clinical translation: i) absolving the need for offline geometric calibration of the C-arm; and ii) solving multiple component bodies simultaneously, thereby allowing QA in a single step (e.g., spinal construct with 4–20 screws), rather than sequential QA of each component. Performance was tested in a spine phantom with 10 pedicle screws, and first results from clinical studies are reported. Results: Phantom experiments demonstrated median target registration error (TRE) of (1.0±0.3) mm at the screw tip and (0.7°±0.4°) in angulation. The simultaneous multi-body registration approach improved TRE from the previous (sequential) method by 42%, reduced outliers, and fits into the natural workflow. Initial application of KC-Reg in clinical data shows TRE of (2.5±4.5) mm and (4.7°±0.5°). Conclusion: The KC-Reg algorithm offers a potentially valuable method for quantitative QA of the surgical product, using radiographic systems that are already within the surgical arsenal. For spine surgery, the method offers a near-real-time independent check on the quality of surgical product, facilitating immediate revision if necessary and potentially avoiding postoperative morbidity and/or revision surgery. Gerhard Kleinszig and Sebastian Vogt are employees of Siemens Healthcare.

60 APPLIED LIFE SCIENCES↗

A search for planetary eclipses of white dwarfs in the Pan-STARRS1 medium-deep fields

We present a search for eclipses of ∼1700 white dwarfs (WDs) in the Pan-STARRS1 medium-deep fields. Candidate eclipse events are selected by identifying low outliers in over 4.3 million light curve measurements. We find no short-duration eclipses consistent with being caused by a planetary size companion. This large data set enables us to place strong constraints on the close-in planet occurrence rates around WDs for planets as small as 2 R {sub ⊕}. Our results indicate that gas giant planets orbiting just outside the Roche limit are rare, occurring around less than 0.5% of WDs. Habitable-zone super-Earths and hot super-Earths are less abundant than similar classes of planets around main-sequence stars. These constraints provide important insight into the ultimate fate of the large population of exoplanets orbiting main-sequence stars.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-F-J-21: Clinical Evaluation of Surface Scanning Systems in Different Treatment Locations

Purpose: To reduce imaging dose in fractionated IGRT, the ability of optical surface imaging systems (OSIS) to detect setup errors was tested. Therefore, clinical studies to evaluate for different treatment locations setup corrections derived by OSIS in comparison with x-ray image guidance in fractionated radiation therapy was performed. Methods: The setup correction accuracy of an OSIS system (AlignRT, VisionRT, London, UK) will be analysed for the 4 tumour locations Pelvis, Upper Abdomen, Thorax and Breast, 20 patients for each location in comparison to a different system (Sentinel, C-RAD, SE). For each patient, the setup corrections of the cone-beam computed tomography (CBCT) of an Elekta Versa HD linear accelerator (Elekta, Crawley, UK) is considered as gold-standard and then compared with those of the OSIS for the first ten fractions retrospectively. There were no clinical decisions made based on the surrogate system. For the OSIS, the reference surface is highly important as it represents the actual ground truth. It can be obtained either with the system itself or the surface structure delineated in the planning CT can be imported via DICOM interface. In this paper, the first results for the treatment region thorax are presented. The reference image modalities were compared. Results: Table 1 displays the difference between the setup corrections obtained with OSIS and CBCT in lateral (LAT), longitudinal (LNG) and vertical (VRT) direction for the DICOM reference image. While the median deviations are within a few millimeters, some outliers showed large deviations. Generally, the mean deviation as well as the spread was smallest in lateral and largest in vertical direction. Conclusion: Although the system allows fast, simple and non-invasive determination of setup corrections, it should be evaluated treatment region dependant. Therefore, the study is ongoing. The application of OSIS may help to reduce the imaging dose for the patient. We gratefully acknowledge the support by our colleagues from the Radiological University Clinic Heidelberg, where the study was performed. This work was funded by the Federal Ministry of Education and Research (BMBF) Germany, grant number 01IB13001B.

60 APPLIED LIFE SCIENCES↗

HD 222925: A New Opportunity to Explore the Astrophysical and Nuclear Conditions of r-process Sites

Abstract With the most trans-iron elements detected of any star outside the solar system, HD 222925 represents the most complete chemical inventory among metal-poor stars enhanced with elements made by the rapid neutron capture (“ r ”) process. As such, HD 222925 may be a new “template” for the observational r -process, where before the (much higher-metallicity) solar r -process residuals were used. In this work, we test under which conditions a single site accounts for the entire elemental r -process abundance pattern of HD 222925. We found that several of our tests—with the single exception of the black hole–neutron star merger case—challenge the single-site assumption by producing an ejecta distribution that is highly constrained, in disagreement with simulation predictions. However, we found that ejecta distributions that are more in line with simulations can be obtained under the condition that the nuclear data near the second r -process peak are changed. Therefore, for HD 222925 to be a canonical r -process template likely as a product of a single astrophysical source, the nuclear data need to be reevaluated. The new elemental abundance pattern of HD 222925—including the abundances obtained from space-based, ultraviolet (UV) data—call for a deeper understanding of both astrophysical r -process sites and nuclear data. Similar UV observations of additional r -process–enhanced stars will be required to determine whether the elemental abundance pattern of HD 222925 is indeed a canonical template (or an outlier) for the r -process at low metallicity.

79 ASTRONOMY AND ASTROPHYSICS↗

Southeast Carbon Sequestration Partnership (SECARB) Phase III Anthropogenic Test at Citronelle Field, Mobile Co., AL Surface and Shallow Subsurface Monitoring

The Southeast Carbon Sequestration Partnership Phase III Anthropogenic Test at Citronelle Field is one of the United States’ largest demonstrations of CO 2 capture, transportation, injection, storage and monitoring using CO 2 derived from a coal-fired electric generating unit. This report summarizes the background and initial injection phase groundwater and soil flux monitoring results. The purpose of the groundwater monitoring program, as prescribed in the Underground Injection Control (UIC) permits is to assure that the project’s activities do not harm Underground Sources of Drinking Water (USDWs). In particular, the objective of the program is to monitor for the release of injected CO2 into groundwater aquifers at the project site. Three shallow USDW monitoring wells were installed as part of the groundwater monitoring program. In addition, a water supply well located near the project’s deep characterization well was utilized for monitoring. Seventeen metals, general chemistry and field parameters (e.g. pH, specific conductance, turbidity) were sampled three times prior to injection and quarterly during the injection period to date. Changes in groundwater geochemistry potentially attributable to a release of carbon dioxide into the USDW from the injection activities are decreasing pH and increasing TIC. The change in pH may also accompany the mobilization of certain metals within the groundwater, but the changes are likely site-specific, based on the natural aquifer mineralogy (Wilkin and Diguilio, 2010). At this time, no downward trends for pH and increasing trends for TIC have been statistically determined in the monitor wells. Valid detections exceeding both the UIC discharge limit and the range of background concentrations observed as of the N=11 event include: Exceedance of the UIC permit discharge limit of manganese at D-9-7 MW-2S and D-9-9 MW-1, and exceedance of the UIC permit discharge limit of iron at D-9-9 MW-1. In addition, a statistically significant increase of barium and manganese has been observed at D-9-9 MW-1. However, Additional lines of evidence (namely, expected shifts in TIC or pH, per the research cited above) to interpret the cause (e.g., potential carbon dioxide influence) of the statistically determined exceedances and/or increases are absent at this time. Quarterly groundwater sampling and analysis will continue throughout the project. The UIC permit requires that soil CO 2 flux shall be monitored at the land surface at the injection site and at nearby locations. Twelve locations were chosen for surveys including a mix of near wellbore and offset locations. To date, 24 surveys have taken place with 12 occurring prior to the onset of injection operations in August 2012. Soil CO 2 flux appears to positively covary with soil temperature. A notably high soil CO 2 flux value (21 µmol/m 2 /sec) was observed from the D-9-9 #2 chamber location during sampling event #24 (9/24/2014). As a result of this finding, the frequency of soil CO 2 flux monitoring events will be increased to twice-monthly until this anomaly can be confirmed or determined to be an outlier. Soil CO 2 flux monitoring will continue for the duration of the project.

01 COAL, LIGNITE, AND PEAT↗

A preliminary investigation into the feasibility of laser ablation U–Pb isotope ratio measurement via all‐faraday cup detection with 10 11 ‐ and 10 13 ‐Ω amplifiers on the Neoma multicollector‐inductively coupled plasma‐mass spectrometer

Rationale Signal detection for uranium–lead (U–Pb) dating of zircon is typically performed via ion counters. Here, we develop a preliminary understanding of the strengths and limitations of faraday‐cup‐based detection. Methods A suite of zircon reference materials and the NIST‐610 glass were sampled using laser ablation followed by U–Pb isotope ratio measurement on a Neoma multicollector‐inductively coupled plasma‐mass spectrometer. Results We were able to produce geologically accurate 207 Pb/ 206 Pb, 206 Pb/ 238 U, and 207 Pb/ 235 U ratios for the NIST‐610 glass and the zircon standards, with ages ranging from ~2.5 Ga to ~337 Ma (TanBrown A, Oracle, 91550, Mud Tank, Temora, and Plešovice). Two of the younger zircon standards examined (94‐35, ~55.6 Ma, and Fish Canyon, 28.6 Ma) yielded accurate 206 Pb/ 238 U but not 207 Pb/ 235 U or 207 Pb/ 206 Pb ratios, whereas the youngest zircon standard (Penglai, ~4.4 Ma) failed for all three ratios of interest. The accuracy and precision of the all‐faraday method are directly tied to signal intensity, with reliable data capable of being produced even when both isotopes in a ratio have signals below ~0.001 V (equivalent to ~62 500 cps on an ion counter). Conclusion The all‐faraday cup multicollection method provides sufficient sensitivity to obtain geologically meaningful U–Pb data, with possible advantages being that laser pit depth‐dependent changes in the observed interelemental fractionation behavior may be easier to correct using a static collector configuration compared to when the ion beam is swept across a single detector while also removing the need for an interdetector‐type calibration. Further work is needed to refine the all‐faraday cup method (e.g., application of background subtraction and common Pb corrections, outlier removal, and interelement as well as down‐hole fractionation corrections), but our initial results demonstrate that the faraday detector method has sufficient sensitivity to warrant further study.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

INTERNATIONAL STUDY OF ALUMINUM IMPACTS ON CRYSTALLIZATION IN U.S. HIGH LEVEL WASTE GLASS

The objective of this task was to develop glass formulations for (Department of Energy) DOE waste streams with high aluminum concentrations to avoid nepheline formation while maintaining or meeting waste loading and/or waste throughput expectations as well as satisfying critical process and product performance related constraints. Liquidus temperatures and crystallization behavior were carefully characterized to support model development for higher waste loading glasses. The experimental work, characterization, and data interpretation necessary to meet these objectives were performed among three partnering laboratories: the V.G. Khlopin Radium Institute (KRI), Pacific Northwest National Laboratory (PNNL) and Savannah River National Laboratory (SRNL). Projected glass compositional regions that bound anticipated Defense Waste Processing Facility (DWPF) and Hanford high level waste (HLW) glass regions of interest were developed and used to generate glass compositions of interest for meeting the objectives of this study. A thorough statistical analysis was employed to allow for a wide range of waste glass compositions to be examined while minimizing the number of glasses that had to be fabricated and characterized in the laboratory. The glass compositions were divided into two sets, with 45 in the test matrix investigated by the U.S. laboratories and 30 in the test matrix investigated by KRI. Fabrication and characterization of the US and KRI-series glasses were generally handled separately. This report focuses mainly on the US-series glasses. Glasses were fabricated and characterized by SRNL and PNNL. Crystalline phases were identified by X-ray diffraction (XRD) in the quenched and canister centerline cooled (CCC) glasses and were generally iron oxides and spinels, which are not expected to impact durability of the glass. Nepheline was detected in five of the glasses after the CCC heat treatment. Chemical composition measurements for each of the glasses were conducted following an analytical plan. A review of the individual oxides for each glass revealed that there were no errors in batching significant enough to impact the outcome of the study. A comparison of the measured compositions of the replicates indicated an acceptable degree of repeatability as the percent differences for most of the oxides were less than 5% and percent differences for all of the oxides were less than 10 wt%. Chemical durability was measured using the Product Consistency Test (PCT). All but two of the study glasses had normalized leachate for boron (NL [B]) values that were well below that of the Environmental Assessment (EA) reference glass. The two highest NL [B] values were for the CCC versions of glasses US-18 and US-27 (10.498 g/L and 15.962 g/L, respectively). Nepheline crystallization was identified by qualitative XRD in five of the US-series glasses. Each of these five glasses (US-18, US-26, US-27, US-37 and US-43) showed a significant increase in NL [B] values after the CCC heat treatment. This reduction in durability can be attributed to the formation of nepheline during the slow cooling cycle and the removal of glass formers from the residual glass network. The liquidus temperature (T{sub L}) of each glass in the study was determined by both optical microscopy and XRD methods. The correlation coefficient of the measured XRD TL data versus the measured optical TL data was very good (R{sup 2} = 0.9469). Aside from a few outliers, the two datasets aligned very well across the entire temperature range (829 C to 1312 C for optical data and 813 C to 1310 C for XRD crystal fraction data). The data also correlated well with the predictions of a PNNL T{sub L} model. The correlation between the measured and calculated data had a higher degree of merit for the XRD crystal fraction data than for the optical data (higher R{sup 2} value of 0.9089 versus 0.8970 for the optical data). The SEM-EDS analysis of select samples revealed the presence of undissolved RuO{sub 2} in all glasses due to the low solubility of RuO{sub 2} in borosilicate glass. These particles tended to form agglomerates with varying sizes and shapes that were located close to the bottom of crucibles. The results of this study provide further insight into the ability of borosilicate waste glass to incorporate increased (>16 wt %) concentrations of aluminum. The glass composition and properties data will be incorporated into a database of glass composition-property relationships (ComPro) to support further optimization of waste glass compositions at DOE sites.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Performance Assessment of a New Gamma Spectroscopy Toolkit: Peak Doctor and the Spectral Nondestructive Assay Platform (SNAP) - 17397

High resolution gamma spectroscopy (HRGS) is a widely used technique for non-destructive characterization of nuclear materials, and assay of radioactive waste. The ability to accurately evaluate raw spectral data is an important step in producing high-quality results. A spectral analysis application known as Peak Doctor has been developed under a Cooperative Research and Development Agreement (CRADA) between LANL and Pajarito Scientific Corporation (PSC). The software has undergone several years of testing and validation by the Radioactive Waste Characterization Team of the LANL Waste Management Services Group (WM-SVS). PeakDoctor is designed to work with the Spectral Nondestructive Assay Platform (SNAP{sup TM}) to provide a complete HRGS analysis engine. SNAP{sup TM} performs model specific corrections for attenuation and geometry. These applications are the major components of a new toolkit designed primarily for portable far-field non-destructive assay. Peak Doctor performs a very accurate peak fit analysis with the goal of improving upon the capabilities of existing commercially available routines. It is designed to be user-configurable and can be customized to any given type of detector and any given type of spectrum. Peak Doctor was developed to resolve many of the inherent complexities in gamma ray spectra including overlapping peaks, complex multiplet regions, large step peaks, backscatter regions and Compton edges. Unlike most spectral analysis platforms, Peak Doctor does not rely on the energy calibration and detector resolution parameters that are saved by the operator in the spectrum file. Instead, key parameters are pre-defined for individual detectors. The software fits a continuum using a series of splines between a series of junctions or 'knots'. Fitting techniques are used to join the splines together to create a near-continuous multi-element curve. Optimizing the location of the knots is one of Peak Doctor's most powerful features. The knots are initially configured using a pre-defined list and are removed or added automatically during the fitting process. Knots are also created when new features are identified such as Step Peaks and Compton Edges. The user can also manually specify knots in order to improve the continuum fit. The initial fit is improved on by removing any outlier regions (which are converted to peaks) and the continuum fitting process is repeated. At this stage, an experienced user can work interactively with the fit by manually converting peak regions to continuum or vice versa. The final step is to fit a series of peaks above the continuum based on detector parameters. Single and multiplet peaks are then processed by either the tailing (piecewise) or non-tailing (Gaussian) Levenberg Marquardt non-linear peak fitting routine depending on the user defined selection. Only a rough knowledge of the detector characteristics (energy calibration and resolution) is required for the fitting process to proceed with good accuracy. Any peaks that are missed can be manually added by the user and will also be fitted. Discontinuities in the peak / continuum fit can be rapidly identified by reviewing the 'residuals scale' plot. For waste streams that are well characterized, it is often the case that routinely encountered spectra will have similar peaks and continuum features. For these cases a handy 'One Step' method is available that proceeds in an automated fashion without user interaction. Peak Doctor has been configured with a set of default spectrum types including plutonium / transuranic waste (including Weapons Grade Pu, Heat Source Pu, Am-241, Am-243 and Np-237), depleted or enriched uranium, nuclear power plant / intermediate level waste (with fission and activation products such as Cs-137 and Co-60) as well as Naturally Occurring Radioactive Materials (NORM). The user can easily add new spectrum types for specific waste streams or other types of radiological / special nuclear materials. The output from PeakDoctor (including net peak area, centroid energy and a list of minimum detectable activity levels at pre-defined regions) is used by SNAP{sup TM} to complete the data analysis process. Isotope activities are calculated using configurable template-driven geometry and attenuation correction methods. The software accounts for matrix and container wall effects, collimator / angular corrections, detector efficiency (based on calibration curves) and stand-off distance. SNAP{sup TM} uses published algorithms incorporating a series of decision points during its operation to allow the analyst to provide logical input to guide the software during the analysis of each unique spectrum. The Peak Doctor / SNAP{sup TM} toolkit has been extensively tested and validated under a variety of conditions using 'benchmark' reference spectra. Test scenarios reported include HPGe-based measurements of well characterized uranium and plutonium standards and radioactive sources with a variety of different geometries and matrix materials including surrogate drums and boxes. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Population Properties of Compact Objects from the Second LIGO-Virgo Gravitational-Wave Transient Catalog

We report on the population of 47 compact binary mergers detected with a false-alarm rate of <1yr^(−1) in the second LIGO–Virgo Gravitational-Wave Transient Catalog. We observe several characteristics of the merging binary black hole (BBH) population not discernible until now. First, the primary mass spectrum contains structure beyond a power law with a sharp high-mass cutoff; it is more consistent with a broken power law with a break at 39.7^(+20.3)(-9.1)M or a power law with a Gaussian feature peaking at 33.1^(+4.0)(-5.6)M (90% credible interval). While the primary mass distribution must extend to ~65M or beyond, only 2.9^(+3.5)(-1.7)M% of systems have primary masses greater than 45M. Second, we find that a fraction of BBH systems have component spins misaligned with the orbital angular momentum, giving rise to precession of the orbital plane. Moreover, 12% to 44% of BBH systems have spins tilted by more than 90°, giving rise to a negative effective inspiral spin parameter, χeff. Under the assumption that such systems can only be formed by dynamical interactions, we infer that between 25% and 93% of BBHs with nonvanishing |χeff| > 0.01 are dynamically assembled. Third, we estimate merger rates, finding RBBH = 23.9^(+14.3)(-8.6) Gpc^(-3) yr^(-1) for BBHs and RBNS = 320^(+490)(-240) Gpc^(-3) yr^(-1) for binary neutron stars. We find that the BBH rate likely increases with redshift (85% credibility) but not faster than the star formation rate (86% credibility). Additionally, we examine recent exceptional events in the context of our population models, finding that the asymmetric masses of GW190412 and the high component masses of GW190521 are consistent with our models, but the low secondary mass of GW190814 makes it an outlier.

R Abbott↗

Improvements to the operational efficiency of the Portsmouth 'Blue Box' Assay system - 15162

The 'Blue Box' in Building 326 at Portsmouth comprises a dual cargo container lined with high density polyethylene with 5% (elemental) boron that acts as a neutron shield. This construction provides a low environmental neutron background to support the capability to attain low values of minimal detectable activity (MDA). A Non-destructive Assay (NDA) measurement platform known as the Fluor B and W Portsmouth Slab Counter (FBPSC) is housed inside the Blue Box. This comprises four neutron slab detectors supported with an electronic system supplying power and associated signal processing. The system is operated by a laptop computer which has data acquisition and analysis capabilities. Each slab contains five {sup 3}He proportional counters embedded in polyethylene. The system is designed to measure the mass of U-235 in coolers from the Portsmouth site using passive neutron counting. The system was calibrated by taking measurements with {sup 252}Cf sources attached to various positions on the outside surfaces of a surrogate cooler. In addition, Monte-Carlo N-Particle (MCNP) simulations were performed to extend the baseline calibration for coolers of various sizes used in the gaseous-diffusion process. The basic principle of operation is to measure the total neutron emission from the item and determine the mass of {sup 235}U using the system efficiency (determined from MCNP calculations combined with the calibration measurements) combined with known isotopic information ({sup 235}U enrichment and U-235/U-234 ratio), assumed chemical composition, and gross cooler mass. The FBPSC analysis program calculates the mass of U-235 within the cooler being assayed, together with the associated Total Measurement Uncertainty (TMU). A background correction is performed that accounts for the measured environmental background with a cosmic-ray spallation correction (based on the cooler's gross weight). The software suite developed for the system also includes the capability to track and trend measurement control data in order to quickly identify conditions where the system has drifted outside of its quality control envelope. The MDA of the system has been determined to be less the 15 g of U-235 for count times that are typically less than 5 minutes (depending on the uranium isotopics). This is primarily the result of the low neutron background rate inside the Blue Box (approximately 3 times lower than at nearby locations outside the box). Additionally, various software features have been designed to yield optimum counting performance for the system including count time adjustment and interval filtering to reject statistical outliers that are usually associated with cosmic spallation events. The operation of the system has proven to be very efficient, with the short measurement time providing a high throughput rate of coolers through the Blue Box NDA system. Significant operational benefits and improved data traceability have been yielded compared to the previous measurement process, which involved operators taking measurement with counter/scalers and manually entering data into spreadsheets. As of August 2014, this system successfully measured all coolers required to support completion of a contractually-required Performance Milestone. There are approximately 1900 coolers available for measurement. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING CHARACTERIZATION FACILITY (WSCF)

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-846 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (S&GRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a 'blind' sample to the laboratory. Feedback from the S&GRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 2008a). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated-carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 g/L potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent column breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

INVESTIGATION OF THE TOTAL ORGANIC HALOGEN ANALYTICAL METHOD AT THE WASTE SAMPLING AND CHARACTERIZATION FACILITY

Total organic halogen (TOX) is used as a parameter to screen groundwater samples at the Hanford Site. Trending is done for each groundwater well, and changes in TOX and other screening parameters can lead to costly changes in the monitoring protocol. The Waste Sampling and Characterization Facility (WSCF) analyzes groundwater samples for TOX using the United States Environmental Protection Agency (EPA) SW-S46 method 9020B (EPA 1996a). Samples from the Soil and Groundwater Remediation Project (SGRP) are submitted to the WSCF for analysis without information regarding the source of the sample; each sample is in essence a ''blind'' sample to the laboratory. Feedback from the SGRP indicated that some of the WSCF-generated TOX data from groundwater wells had a number of outlier values based on the historical trends (Anastos 200Sa). Additionally, analysts at WSCF observed inconsistent TOX results among field sample replicates. Therefore, the WSCF lab performed an investigation of the TOX analysis to determine the cause of the outlier data points. Two causes were found that contributed to generating out-of-trend TOX data: (1) The presence of inorganic chloride in the groundwater samples: at inorganic chloride concentrations greater than about 10 parts per million (ppm), apparent TOX values increase with increasing chloride concentration. A parallel observation is the increase in apparent breakthrough of TOX from the first to the second activated-carbon adsorption tubes with increasing inorganic chloride concentration. (2) During the sample preparation step, excessive purging of the adsorption tubes with oxygen pressurization gas after sample loading may cause channeling in the activated carbon bed. This channeling leads to poor removal of inorganic chloride during the subsequent wash step with aqueous potassium nitrate. The presence of this residual inorganic chloride then produces erroneously high TOX values. Changes in sample preparation were studied to more effectively remove inorganic chloride from the activated-carbon adsorption tubes. With the TOX sample preparation equipment and TOX analyzers at WSCF, the nitrate wash recommended by EPA SW-846 method 9020B was found to be inadequate to remove inorganic chloride interference. Increasing the nitrate wash concentration from 10 grams per liter (g/L) to 100 giL potassium nitrate and increasing the nitrate wash volume from 3 milliliters (mL) to 10 mL effectively removed the inorganic chloride up to at least 100 ppm chloride in the sample matrix. Excessive purging of the adsorption tubes during sample preparation was eliminated. These changes in sample preparation have been incorporated in the analytical procedure. The results using the revised sample preparation procedure show better agreement of TOX values both for replicate analyses of single samples and for the analysis of replicate samples acquired from the same groundwater well. Furthermore, less apparent adsorption tube breakthrough now occurs with the revised procedure. One additional modification made to sample preparation was to discontinue the treatment of groundwater samples with sodium bisulfite. Sodium bisulfite is used to remove inorganic chlorine from the sample; inorganic chlorine is not expected to be a constituent in these groundwater samples. Several other factors were also investigated as possible sources of anomalous TOX results: (1) Instrument instability: examination of the history of results for TOX laboratory control samples and initial calibration verification standards indicate good long-term precision for the method and instrument. Determination of a method detection limit of 2.3 ppb in a deionized water matrix indicates the method and instrumentation have good stability and repeatability. (2) Non-linear instrument response: the instrument is shown to have good linear response from zero to 200 parts per billion (ppb) TOX. This concentration range encompasses the majority of samples received at WSCF for TOX analysis. Linear response was checked using both non-volatile TOX species (trichlorophenol) and volatile TOX species. Average recoveries of the volatile TOX species ranged between 50% and 75%. (3) Improper sample preservation: ion-chromatographic analysis of several samples with anomalous TOX results revealed that the samples were properly preserved with sulfuric acid and not hydrochloric acid.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗