Search NASA⌕ Search

SEARCH · Search NASA

Results for “performance testing”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Energy efficient engine high-pressure turbine component rig performance test report

A rig test of the cooled high-pressure turbine component for the Energy Efficient Engine was successfully completed. The principal objective of this test was to substantiate the turbine design point performance as well as determine off-design performance with the interaction of the secondary flow system. The measured efficiency of the cooled turbine component was 88.5 percent, which surpassed the rig design goal of 86.5 percent. The secondary flow system in the turbine performed according to the design intent. Characterization studies showed that secondary flow system performance is insensitive to flow and pressure variations. Overall, this test has demonstrated that a highly-loaded, transonic, single-stage turbine can achieve a high level of operating efficiency.

Leach, K. P.↗

Thermal performance testing of two Thales 9310 pulse-tube cryocoolers for PHyTIR

PHyTIR is a NASA-funded technology demonstration for a near-term earth-observing instrument in the thermal infrared spectrum, intended for use in the HyspIRI mission. PHyTIR will use two Thales 9310 single-stage pulse tube cryocoolers, one to directly cool the FPA, the other to simulate a passive radiator. We report performance measurements for the two Thales 9310 cryocoolers intended for inclusion in the PHyTIR demonstrator.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A digital CDS technique and its performance testing

Readout noise is a critical parameter for characterizing the performance of charge-coupled devices (CCDs), which can be greatly reduced by the correlated double sampling (CDS) circuit. However, a conventional CDS circuit inevitably introduces new noise since it consists of several active analog components such as operational amplifiers. This article proposes a digital CDS circuit technique, which transforms the pre-amplified CCD signal into a train of digital presentations by a high-speed data acquisition card directly without the noisy CDS circuit, then implements the digital CDS algorithm through a numerical method. A readout noise of 3.3 e - and an energy resolution of 121 eV@5.9 keV can be achieved via the digital CDS technique.

42 ENGINEERING↗

Thermal Performance Testing of EMU and OSS Liquid Cooling Garments

A test was conducted to evaluate three factors influencing the thermal performance of liquid cooling garments (LCG): (1) the comparable thermal performance of an Oceaneering developed engineering evaluation unit (EEU) prototype LDG, (2) the effect of the thermal comfort undergarment (TCU), and (3) the performance of a torso or upper body only LCG configuration. To evaluate the thermal performance of each configuration a metabolic test was conducted, utilizing suited subjects to generate the metabolic heat. For this study three (3) test subjects of similar health and weight produced a metabolic load on the LDG configuration by either resting (300-600 BTU/hr), walking at a slow pace (1200 BRU/hr), and walking at a brisk pace (2200 BTU/hr), as outlined in Figure 1, the metabolic profile. During the test, oxygen consumption, heart rate, relative humidity, air flow, inlet and outlet air pressure, inlet and outlet air temperature, delta air temperature, water flow (100 lb/hr), inlet water temperature (64 F), delta water temperature, water pressure, core body temperature, skin temperature, and sweat loss data was recorded. Four different test configurations were tested, with one configuration tested twice, as outlined in Table 1. The test was conducted with the suit subjects wearing the Demonstrator Suit, pressurized to vent pressure (approximately 0.5 psig). The demonstrator suit has an integrated ventilation duct system and was used to create a relevant environment with a captured ventilation return, an integrated vent tree, and thermal insulation from the environment.

Rhodes, Richard↗

Performance tests of boron-coated straw detectors with thermal and cold neutron beams

Prototypes of in-house developed boron-coated straw (BCS) detectors have been tested in the thermal and cold neutron energy ranges. Their neutron detection performance has been benchmarked against the industry standard (detector tubes filled with 3 He gas). The tests show that the BCS detectors perform near their theoretical limit regarding the detection efficiency, which is adequate for scientific instruments in the cold neutron energy range. Finally, the BCS detectors perform on par with 3 He tubes in terms of signal to noise and timing resolution, and superior regarding longitudinal spatial resolution.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Performance testing of thermoelectric generators at JPL

Results of life tests of thermoelectric generators ranging in output power from 800 microwatts to 170 watts. Emphasis is placed on the results obtained from tests of three advanced prototypes - a high-performance generator, a transit-type generator, and a ring converter. In addition, the results of life tests of a number of generators representing Nimbus, Pioneer, and Viking technology are presented.

Rouklove, P.↗

Outdoor performance testing of thin-film devices

The Advanced Systems Research Group supports the photovoltaic advanced R&D (PV AR&D) project by providing outdoor (global) testing of PV cells, submodules, modules, and arrays. The group also provides in house engineering and analysis to identify and determine how technical issues such as cell/module/system adaptations, long term stability, reliability, economics, materials availability, safety, and environmental impacts affect the development and ultimate use of advanced PV thin film, innovative cell, and material technologies. A major thrust of the research effort is to develop and utilize instrumentation and procedures for monitoring and analyzing PV cells and submodules including outdoor performance and stability testing and life cycle accelerated stress testing. To accomplish the above, the solar energy research institute (SERI) outdoor PV test facility was established in 1982. The group has designed testing systems and analysis procedures for, and has tested, numerous amorphous silicon thin film submodules provided by SERI subcontractors and has performed long term outdoor stability tests on CdS/CuIr Se sub 2 and hydrogen passivated silicon solar cells. A significant contribution from this facility over the past year was the testing of large area amorphous silicon submodules.

Source record↗

Optical measurements and tests performed in a low-gravity environment

Shadowgraph and schlieren techniques have been used on board the NASA KC-135 low-gravity simulation aircraft to measure gravity-related fluid flow occurring in various experimental configurations. These configurations included cooled and solidified ammonium chloride and water, electrodeposited cobalt in CoSO4 solution, and immiscible and crystal melt solutions. Hardware tests have also been performed for such critical optical system components as lasers and spatial filters to determine their performance and operation under low-gravity conditions. These test results will be used in the design of the various future Shuttle experiments which will utilize advanced optical measurement techniques. The design and configuration of the optical systems used to make these measurements and tests are presented, and the performance and operation of these systems and their components under low-gravity conditions are discussed. Some preliminary results are included.

Owen, R. B.↗

AN OVERVIEW OF THE DESIGN AND PERFORMANCE TESTING OF A 275 BAR INTEGRALLY GEARED SUPERCRITICAL CO2 COMPRESSOR FOR POWER GENERATION

An integrally geared compressor-expander (compander) for supercritical CO2 (sCO2) was developed to convert thermal energy to electricity. With operating pressures of 275 bar, this turbomachine represents the state of the art in integrally geared machine architecture, hitting compressor inlet densities of 600 kg/m3 and discharge pressures of 275 bar. The product development was funded by the Department of Energy’s Energy Efficiency and Renewable Energy Office under EE0007114 to advance the state of the art in concentrated solar power applications; however, the technology itself is agnostic to heat source, and is predicted to achieve a thermal-to-electric conversion efficiency of 50% for any indirect heat source capable of providing turbine inlet temperatures of 700°C or greater. While the program encompassed the design and testing for the compressor and turbine elements, this paper will focus on the compressor design and operation. The paper will begin with an introduction to the cycle design and analysis of an indirectly heated integrally geared sCO2 compander, a discussion of the mechanical and aerodynamic design of the compressor that is a two stage radial compressor operating subcritically at 27,512 rpm, and will then proceed to describe the test facility and measured data to characterize the performance and robustness of the machine. The paper will conclude with a discussion on lessons learned throughout the course of commissioning and testing. Practical aspects of testing a compressor operating near the dome including complications relating to obtaining an accurate compressor flow map, efficiency calculations, flow unsteadiness, and associated measurement uncertainties will be discussed.

wilkes, jason↗

Concentrating solar collector-performance tests

Report summarizes test results from evaluation of concentrating solar collector thermal performance, from transient behavior, and incident-of-angle behavior. Tests were conducted using National Bureau of Standards recommedations and specifications.

Source record↗

Thermodynamic performance testing of the orbiter flash evaporator system

System level testing of the space shuttle orbiter's development flash evaporator system (FES) was performed in a thermal vacuum chamber capable of simulating ambient ascent, orbital, and entry temperature and pressure profiles. The test article included the evaporator assembly, high load and topping exhaust duct and nozzle assemblies, and feedwater supply assembly. Steady state and transient heat load, water pressure/temperature and ambient pressure/temperature profiles were imposed by especially designed supporting test hardware. Testing in 1978 verified evaporator and duct heater thermal design, determined FES performance boundaries, and assessed topping evaporator plume characteristics. Testing in 1979 combined the FES with the other systems in the orbiter active thermal control subsystem (ATCS). The FES met or exceeded all nominal and contingency performance requirements during operation with the integrated ATCS. During both tests stability problems were encountered during steady state operations which resulted in subsequent design changes to the water spray nozzle and valve plate assemblies.

Jaax, J. R.↗

Grid Interconnection and Performance Testing Procedures for Vehicle-To-Grid (V2G) Power Electronics: Preprint

Bidirectional power electronics can add vehicle-to-grid (V2G) capability in a plug-in vehicle, which then allows the vehicle to operate as a distributed resource (DR). The uniqueness of the battery-based V2G power electronics requires a test procedure that will not only maintain IEEE interconnection standards, but can also evaluate the electrical performance of the vehicle working as a DR. Theobjective of this paper is to discuss a recently published NREL technical report that provides interim test procedures for V2G vehicles for their integration into the electrical distribution systems and for their performance in terms of continuous output power, efficiency, and losses. Additionally, some other test procedures are discussed that are applicable to a V2G vehicle that desires toprovide power reserve functions. A few sample test results are provided based on testing of prototype V2G vehicles at NREL.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Development of a frequency regulation duty-cycle for standardized energy storage performance testing

The US DOE Protocol for uniformly measuring and expressing the performance of energy storage systems, first developed in 2012 through inclusive working group activities, provides standardized methodologies for evaluating an energy storage system’s ability to supply specific services to electrical grids. This article elaborates on the data and decisions behind the duty-cycle used for frequency regulation in this protocol. Analysis of a year of publicly available frequency regulation control signal data from a utility was considered in developing the representative signal for this use case. Moreover, this showed that signal standard deviation can be used as a metric for aggressiveness or rigor. From these data, we select representative 2 h long signals that exhibit nearly all of dynamics of actual usage under two distinct regimens, one for average use and the other for highly aggressive use. Our results were combined into a 24-h duty-cycle comprised of average and aggressive segments. The benefits and drawbacks of the selected duty-cycle are discussed along with its potential implications to the energy storage industry.

25 ENERGY STORAGE↗

Performance Testing and Validation Plan for HMS4 Quantitative Gamma Measurements, K-25/K-27 D&D Project, East Tennessee Technology Park, Oak Ridge, Tennessee

The Holdup Measurement System 4 (HMS4) is a portable thallium activated sodium iodide (NaI[Tl]) gamma ray energy spectrometer that, when properly calibrated, is able to make quantifiable assessment of U-235 holdup in the presence of other uranium isotopes and prevailing background radiation. The use and calibration of the HMS4 is based upon the methodologies defined by Russo in La-14206, (Russo 2005), where detection efficiency determination protocols are defined (called Generalized Geometry Holdup [GGH]). The GGH methodology together with attenuation correction algorithms and other modeling parameters are combined in the HMS4 software package to provide a comprehensive tool for conducting in situ gamma-ray measurements. The fundamental principles of these capabilities are discussed.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SPHERICAL RESORCINOL-FORMALDEHYDE PERFORMANCE TESTING WITH HANFORD TANK WASTE

The efficacy of a new spherically engineered form of resorcinol-formaldehyde (RF) resin was tested for cesium removal on two actual Hanford tank wastes. Small-scale processing was conducted according to the River Protection Project-Waste Treatment and Immobilization Plant flowsheet in a lead-lag column format. The RF resin processed 95 bed volumes (BVs) of high potassium-bearing waste (AP-101) and >200 BVs of a high complexant-bearing waste (AN-102) before reaching 50% cesium breakthrough. Elution with 0.5 M nitric acid was effective and complete after processing 16 BVs. Cesium and other analyte fractionations to the process stream effluent and eluate were evaluated. The RF resin resulted in very little metal and radionuclide fractionation, other than cesium, to the eluate. The spent resins were measured for most analytes relevant to land-disposal requirements. The actinide concentrations on the spent resins were <3% of the transuranic waste limit; the residual cesium concentrations were <4 mCi/kg; chromium was the only metal, regulated by the Resource Conservation Recovery Act, that was measured in quantities significant to land-disposal regulations.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Motorette Thermal Performance Testing and Modeling for an Electric Motor with Additively Manufactured Hollow Conductors with Integrated Heat Pipes

This paper discusses the design, build and test of a motorette to characterize the thermal performance of an additively manufactured coil integrated with heat pipes. The motorette is powered using a variable frequency AC power supply and cooled through two independent cooling systems. The first cooling system cools the stator core using forced convection of air flowing over a finned heat sink mounted on the stator outer diameter. The second cooling system cools the heat pipes using forced convection of 50-50 water ethylene glycol (WEG) mixture flowing through condenser chambers. A 3D thermal FEA model of the setup is built and heat transfer coefficients (HTC) of convective boundaries are computed using coolant flow rates from test data and empirical equations. Temperature at locations on the coil and heat sink are recorded and compared to thermal model predicted values. A maximum temperature error of 22.7% occurs at 180ARMS and 800 Hz operating point for the AM dual coil. The thermal model provides higher temperatures compared to test results and hence it is on the conservative side but in general, there is good correlation between test and model results. Lastly, opportunities for improvement to both test data measurement and 3D thermal FEA modeling are discussed.

additive manufacturing↗

Integrated Performance Testing for Nonproliferation Support Project

The objective of this workshop is to provide participants with training in testing techniques and methodologies for assessment of the performance of: Physical Protection system elements; Material Control and Accounting (MC&A) system elements.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗