Two Phase Detonation as Related to Rocket Motor Combustion Instability
Two phase detonations in liquid-gas system of liquid rocket motor
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Two phase detonations in liquid-gas system of liquid rocket motor
Compressible flow of two component, two phase mixtures in nozzles and orifices
Elastic-plastic shear cracks propagation in two phase composite materials using dislocation model, determining critical fracture strength
Compressible flow of two component two phase mixtures through convergent nozzles and orifices, determining initially or annular dispersed flow patterns
The performance of experimental two phase, charge-coupled shift registers constructed using polysilicon gates overlapped by aluminum gates was studied. Shift registers with 64, 128, and 500 stages were built and operated. Devices were operated at the maximum clock frequency of 20 MHz. Loss per transfer of less than .0001 was demonstrated for fat zero operation. The effect upon transfer efficiency of various structural and materials parameters was investigated including substrate orientation, resistivity, and conductivity type; channel width and channel length; and method of channel confinement. Operation of the devices with and without fat zero was studied as well as operation in the complete charge transfer mode and the bias charge, or bucket brigade mode.
The as-extruded microstructures of two alloys in the two phase field consisting of Ni3Al and NiAl in the Ni-Al phase diagram exhibit fibrous morphology and consist of Ll(2) Ni3Al and B2 NiAl. These as-extruded microstructures can be modified dramatically by suitable heat treatments. Martensite plus NiAl or martensite plus Ni3Al microstructures are obtained upon quenching from 1523 K. Aging of martensite at 873 K results in the recently identified phase Ni5Al, whereas aging at 1123 K reverts the microstructures to Ni3Al plus NiAl. The microstructures with predominantly martensite of Ni5Al3 phases are brittle in tension at room temperature. The latter microstructure does not deform plastically even in compression at room temperature. However, some promise of room temperature tensile ductility is indicated by the Ni3Al plus NiAl phase mixtures.
The high power density of emerging electronic devices is driving the transition from remote cooling, which relies on conduction and spreading, to embedded cooling, which extracts dissipated heat on-site. Two-phase microgap coolers employ the forced flow of dielectric fluids undergoing phase change in a heated channel within or between devices. Such coolers must work reliably in all orientations for a variety of applications (e.g., vehicle-based equipment), as well as in microgravity and high-g for aerospace applications, but the lack of acceptable models and correlations for orientation- and gravity-independent operation has limited their use. Reliable criteria for achieving orientation- and gravity-independent flow boiling would enable emerging systems to exploit this thermal management technique and streamline the technology development process. As a first step toward understanding the effect of gravity in two-phase microgap flow and transport, in an earlier effort, the authors studied the effects of evaporator orientation, mass flux, and heat flux on flow boiling of HFE7100 in a 1.01 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. Orientation-independence, defined as achieving similar critical heat fluxes, heat transfer coefficients, and flow regimes across orientations, was achieved for mass fluxes of 400 kg/sq.m-s and greater (corresponding to a Froude number of about 0.8). In the present effort, the authors have studied the effects of gravity, mass flux, and subcooling on flow boiling of HFE7100 in a 0.17 mm tall by 13.0 mm wide by 12.7 mm long microgap channel. The Flow Boiling in Microgap Coolers payload experienced about three minutes of weightlessness and shorter periods of high-g (up to about 5 g) during two recent flights aboard the Blue Origin New Shepard reusable launch vehicle. The results from the flight experiments will be presented and compared with published criteria for achieving gravity-independence.
The response of two-phase droplets to intense radiant heating is studied to determine the incident power that is required for causing explosive boiling in the liquid phase. The droplets studied consist of strongly absorbing coal particles dispersed in a weakly absorbing water medium. Experiments are performed by confining droplets (radii of 37, 55, and 80 microns) electrodynamically and irradiating them from two sides with pulsed laser beams. Emphasis is placed on the transition region from accelerated droplet vaporization to droplet superheating and explosive boiling. The time scale observed for explosive boiling is more than 2 orders of magnitude longer than published values for pure liquids. The delayed response is the result of energy transfer limitations between the absorbing solid phase and the surrounding liquid.
Two phase mass flowmeter with two dissimilar porous cartridges
Differential equations for local interfacial and wall shear stresses for one-dimensional annular two-phase flow
Calculation of mass-flow and thrust produced for two-phase fluid mixture passing through choked nozzle
A two-phase methodology that can be used to guide R&D managers in the evaluation and selection of competing technologies is presented. Deterministic multiattribute utility theory is used in the first phase to rank the technological alternatives; the example presented involves the evaluation of electric and hybrid passenger vehicles. In all, 39 individuals from eight automotive firms were interviewed to assess their risk preferences and attitudes toward the vehicle design. In the second phase, the decision-maker must allocate a fixed amount of resources to different projects for the technology selected, some of which may be undertaken in parallel, to maximize a given measure of performance. When parallel funding is pursued the best outcome is chosen. The problem is formulated as a probabilistic network and solved heuristically using Monte Carlo simulation. Results are presented for two decision-makers and three budget options. In each case, the heuristic finds the optimal allocation of funds.
Effective cryogenic fluid management is important to the success of future manned and unmanned NASA missions, and the transfer line chilldown process is recognized as a key technological challenge. To address this challenge, the Two-phase Flow and Thermal Management Lab (TFTML) at Case Western Reserve University is collaborating with NASA Glenn Research Center to develop, test and deploy a closed loop two-phase flow chilldown test section onboard the International Space Station to be integrated with the current Flow Boiling and Condensation Experiment (FBCE) module. The final results of this project will create the first chilldown process database under pure and sustained microgravity conditions and will significantly advance the understanding of the chilldown process for cryogenic fluid management. In the present work, the ground-based test results of the closed loop SS-316 chilldown test section in a horizontal configuration at varying inlet mass flow rates (3-40 g/s) and inlet liquid subcooling (5-35 0C) are presented. The working fluid is PF-5060 and the chilldown curves captured the entire quenching curve involving the different boiling regimes and temperature transition points viz., film boiling, Leidenfrost/re-wetting point, transition boiling, critical heat flux (CHF), nucleate boiling, onset of nucleate boiling (ONB) and single-phase liquid flow regions, when the test section is pre-heated to around 250 0C. The major findings of the present study are, (i) the bottom part of the test section sees a lower re-wetting temperature due to the horizontal flow configuration, (ii) the re-wetting temperatures are relatively unaffected by inlet liquid mass flow rates though the increase in mass flow rates reduce the chilldown time, and (iii) the re-wetting temperatures decrease with decrease in inlet liquid subcooling. Further, preliminary flow visualization studies in a transparent pyrex test section will also be presented to understand the intricate flow boiling regime transitions during the chilldown process.
The Conductivity Sensor designed for use in the Node 3 Water Processor Assembly (WPA) was based on the existing Space Shuttle application for the fuel cell water system. However, engineering analysis has determined that this sensor design is potentially sensitive to two-phase fluid flow (gadliquid) in microgravity. The source for this sensitivity is the fact that gas bubbles will become lodged between the sensor probe and the wall of the housing without the aid of buoyancy in l-g. Once gas becomes lodged in the housing, the measured conductivity will be offset based on the volume of occluded gas. A development conductivity sensor was flown on the NASA Microgravity Plan to measure the offset, which was determined to range between 0 and 50%. Based on these findings, a development program was initiated at the sensor s manufacturer to develop a sensor design fully compatible with two-phase fluid flow in microgravity.
Scaling Analysis of Two-Phase Flow in Fractal Permeability Field
The stability of film boiling two phase flow is investigated referring in particular to saturated cryogenic liquids. This type of fluid motion is unstable, such that a range of wave numbers will always be present in which disturbances are amplified. Further the mode of operation of the energy supply system may favour temperature fluctuations of large amplitude if the circuit does not provide feed-back compensation. The theoretically predicted stabilization due to capillarity is reduced considerably in liquefied gases with low surface tension, such as hydrogen. This effect causes the transition to turbulent flow to occur at low Reynolds numbers, and increases the heat transport in the turbulent regime. A comparison with experimental data, (horizontal cylinder), shows that the "critical" film Reynolds number ūδ/𝜈, at which instabilities become effective, is lowered from approximately 200, (O2), to about 30, (H2). Similar results have been found with other configurations. Therefore application of laminar film boiling solutions is restricted to small objects, entrance regions, or stagnation points. Turbulent correlations given so far are valid only for a certain group of substances with similar behavior.
Alkali metal two-phase heat transfer and flow characteristics for a rankine-cycle space power system
Two phase hydrogen density measurements using open ended microwave cavity