Search NASA⌕ Search

SEARCH · Search NASA

Results for “plasma spectroscopy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

X-ray spectroscopy of the galaxy M87 - Radiative accretion of the hot plasma halo

Canizares et al. (1979) have reported the detection of the O VIII Lyman-alpha line from the vicinity of the giant elliptical galaxy M87 in the Virgo cluster. The detection is based on high-resolution X-ray spectroscopy studies performed with the Focal Plane Crystal Spectrometer on the Einstein Observatory. The presence of a strong O VIII line indicates the existence of some material which is cooler than the bulk of the X-ray emitting gas surrounding M87. The result is interpreted as favoring models which call for radiative accretion of the hot gas onto M87. The present investigation is concerned with further high-resolution X-ray spectroscopy of M87. Seven additional emission line blends due primarily to ionized iron have been detected. These data make it possible to derive the approximate distribution of the quantity of emitting material over more than a decade in temperature for the central part of the M87 source. The obtained results are in excellent agreement with expectations for radiative, pressure driven accretion.

Canizares, C. R.↗

Plasma dynamics, instabilities and OH generation in a pulsed atmospheric pressure plasma with liquid cathode: a diagnostic study

Abstract While plasma–liquid interactions have been an important focus in the plasma research community, the impact of the strong coupling between plasma and liquid on plasma properties and processes remains not fully understood. In this work, we report on the impact of the applied voltage, pulse width and liquid conductivity on the plasma morphology and the OH generation for a positive pulsed DC atmospheric pressure plasma jet with He–0.1% H 2 O mixture interacting with a liquid cathode. We adopted diagnostic techniques of fast imaging, 2D laser induced fluorescence of OH and Thomson scattering spectroscopy. We show that plasma instabilities and enhanced evaporation occur and have a significant impact on the OH generation. At elevated plasma energies, it is found that the plasma contracts due to a thermal instability through Ohmic heating and the contraction coincides with a depletion in the OH density in the core due to electron impact dissociation. For lower plasma energies, the instability is suppressed/delayed by the equivalent series resistor of the liquid electrode. An estimation of the energy flux from the plasma to the liquid shows that the energy flux of the ions released into the liquid by positive ion hydration is dominant, and significantly larger than the energy needed to evaporate sufficient amount of water to account for the measured H 2 O concentration increase near the plasma–liquid interface.

Physics↗

Diagnosing Field Strengths and Plasma Conditions in Magnetically Insulated Transmission Lines Using Active Dopant Spectroscopy

Experimental validation data is needed to inform simulations of large pulsed power devices which are in development to understand and improve existing accelerators and inform future pulsed power capabilities. Using current spectroscopic techniques on the Z-machine, we have been unable to reliably diagnose plasma conditions and electric and magnetic fields within power flow regions. Laser ablation of a material produces a low density plasma, resulting in narrow spectroscopic line widths. By introducing a laser ablated plasma to the anode cathode gap of the Mykonos accelerator, we can monitor how the line shapes change due the current pulse by comparing these line shapes to spectral measurements taken without power flow. In this report we show several examples of measurements conducted on Mykonos on various dopant materials. We also show a negligible effect on power flow due to the presence of the ablation plasma for a range of parameters.

43 PARTICLE ACCELERATORS↗

Comparing plasma conditions in short-pulse-heated foils via fine-structure x-ray emission

Fine-structure x-ray spectra have been measured from foils with embedded tracer layers at two laser facilities. In this work, a suite of layered foils with thin Ti tracers under varied tamper layers was studied at both the Titan and the ALEPH 400 nm laser facilities, where Ti Heα emission was recorded using a high-resolution Bragg crystal spectrometer. Several indicators of plasma parameters are examined in the spectra, including temperature- and density-dependent line ratios and line broadening from Stark and opacity effects. Spectra indicate that (1) the plasma density at ALEPH is significantly higher than at Titan and (2) the electron temperature is high for near-surface layers at both facilities but drops more quickly with depth at ALEPH. These inferences of plasma conditions are consistent with differing levels of temporal contrast at each laser facility.

47 OTHER INSTRUMENTATION↗

Doppler-Free Saturation Spectroscopy (DFSS) for Magnetic and Electric Field Measurements in an FRC plasma

The Cooperative Research and Development Agreement (CRADA) between Oak Ridge National Laboratory (ORNL) and TAE Technologies (TAE) focused on a feasibility study of Doppler-free saturation spectroscopy (DFSS) as a diagnostic strategy to measure the internal magnetic and electric fields of TAE’s C-2W field-reversed configuration (FRC) fusion device. Non-perturbative measurements of magnetic and electric fields in the core of FRCs can provide critical information needed to constrain equilibrium models and for the continued advancement of the fusion research program at TAE. DFSS is a well-established, laser-based absorption spectroscopy technique used to suppress inhomogeneous (Doppler) broadening linewidths and reveal Zeeman/Stark split hyperfine structures of target emission lines. The collaboration involved the use of ORNL’s suite of experimentally validated quantum mechanical modelling codes to simulate theoretical atomic spectra for a variety of machine parameters and laser beam configurations. TAE’s expertise was heavily used to provide measurements/models of the required machine parameters needed as inputs to the simulations. Results of an all-encompassing error analysis demonstrate the favourable capabilities of the diagnostic and provided invaluable insights as to how DFSS can be best used to accurately measure internal B/E-fields in C-2W.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Absolute electron density fluctuation reconstruction for two-dimensional hydrogen beam emission spectroscopy

Scrape-off layer (SOL) and edge plasma turbulence significantly contribute to the radial particle and heat transport, lowering the plasma confinement and increasing the heat load on the plasma facing components. SOL turbulence is predominantly intermittent, which manifests in the occurrence of isolated density filaments or blobs. Filaments propagate radially outward toward plasma facing components, limiting their lifetime by erosion and sputtering. To characterize this phenomenon in detail, few diagnostic techniques are available. Beam emission spectroscopy is a diagnostic capable of measuring plasma turbulence in both SOL and edge plasmas. Due to the finite lifetime of the excitation states during the beam–plasma interaction and the misalignment between the optics and the magnetic field, spatial smearing is introduced in the measurement. In this paper, a novel method is introduced to overcome this hindering effect by inverting the fluctuation response matrix on an optimally smoothed signal. We show that this method is fast and provides significantly more accurate absolute density fluctuation reconstruction than the direct inversion technique. Here, the presented method is usable for all types of beam emission diagnostics where the spatial resolution is higher than the combined smearing of the atomic physics and the observation.

47 OTHER INSTRUMENTATION↗

Experimental evaluation of the vapor box divertor concept with an open vapor box module in Magnum-PSI

A promising approach to handle the intense plasma heat flux in the divertor region of a tokamak is the Vapor Box Divertor (VBD). Here plasma-lithium interaction creates a dense lithium vapor cloud which interacts with the incoming plasma, effectively shielding the tungsten surface beneath, therefore preventing overheating and sputtering of the tungsten and increasing the component’s lifetime. Two key steps must be addressed to validate this concept: investigating plasma-Li interactions and the transport mechanism of the latter in the presence of plasma. To explore this, a Vapor Box Module (VBM) has been designed for use with the linear plasma generator Magnum-PSI. The VBM consists of a series of three cylindrical boxes, with Li being evaporated at a controlled temperature in the central box (CB). Divertor-like plasma enters the VBM from an upstream aperture, interacts with the Li vapor cloud and exits through a downstream aperture ultimately impacting a target equipped with a calorimetry system. Optical diagnostics Thomson scattering, Filtered fast camera Imaging and optical emission spectroscopy provided information on plasma parameters in terms of electron density n e , temperature T e and plasma composition before and after this interaction. A significant reduction in plasma power was observed upon the establishment of lithium vaporization determined via cooling water calorimetry and embedded thermocouples at the downstream target. This resulted in a drop of the target temperature from ∼800 °C to ∼350 °C (57%) at the highest applied power (11.1 MW m −2 ) and CB temperature (∼700 °C). Lithium condensation at the side boxes of the VBM in combination with strong plasma momentum transfer effectively prevented upstream migration of lithium, while enhancing Li transport toward the target. The achievement of the two main goals of reducing plasma power and confining the Li in the VBM, are consistent with earlier published preliminary SOLPS-ITER simulations. This study shows that the presence of lithium in a VBD-like configuration can result in a strong reduction of power to the target surface, while at the same time the lithium vapor is effectively confined by the VBM, aided by the incoming plasma, preventing its escape from the VBM geometry. This represents a valuable step toward validating the feasibility of the VBD configuration in future fusion reactors.

Magnum-PSI↗

Demonstration of Geometric Effects and Resonant Scattering in the X-Ray Spectra of High-Energy-Density Plasmas

In a plasma of sufficient size and density, photons emitted within the system have a probability of being reabsorbed and reemitted multiple times—a phenomenon known in astrophysics as resonant scattering. This effect alters the ratio of optically thick to optically thin lines, depending on the plasma geometry and viewing angle, and has significant implications for the spectra observed in a number of astrophysical scenarios, but has not previously been studied in a controlled laboratory plasma. In this work, we demonstrate the effect in the x-ray spectra emitted by cylindrical plasmas generated by high power laser irradiation, and the results confirm the geometrical interpretation of resonant scattering.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The interplay between laser focusing conditions, expansion dynamics, ablation mechanisms, and emission intensity in ultrafast laser-produced plasmas

The interplay between ultrafast laser focusing conditions, emission intensity, expansion dynamics, and ablation mechanisms is critical to the detection of light isotopes relevant to nuclear energy, forensics, and geochemistry applications. Here, we study deuterium (2Hα) emission in plasmas generated from femtosecond laser ablation of a Zircaloy-4 target with a deuterium concentration of ≈37 at. %. Changes in emission intensity, plume morphology, crater dimensions, and surface modifications were investigated for varying focusing lens positions, where the laser was focused behind, at, and in front of the target. Spatially resolved optical emission spectroscopy and spectrally integrated plasma imaging were performed to investigate emission spectral features and plume morphology. Laser ablation crater dimensions and morphology were analyzed via optical profilometry and scanning electron microscopy. The 2Hα emission intensity showed significant reduction at the geometrical focal point or when the focal point is in front of the target. For all laser spot sizes, a two-component plume was observed but with different temporal histories. At the best focal point, the plume was spherical. When the laser was focused behind the target, the plume was elongated and propagated to farther distances than for the best focal position. In contrast, when the laser was focused in front of the target, filaments were generated in the beam path, and filament-plasma coupling occurred. By focusing the laser behind the target, the amount of material removal in the laser ablation process can be significantly reduced while still generating a plasma with a sufficient 2Hα emission signal for analysis.

Kautz, Elizabeth J. (ORCID:0000000263389223)↗

The Analysis of Emission Lines; A Meeting in Honour of the 70th Birthdays of D. E. Osterbrock and M. J. Seaton

A review of the field of astronomical spectroscopy with emphasis on emission lines in astrophysical plasmas is presented. A brief history of UV spectroscopy instruments is given, following by a discussion and tabulation of major atlases of UV emission-line objects to date (mid-1994). A discussion of the major diagnostic UV emission lines in the approx. 912-3200 A spectral region that are useful for determining electron densities, temperatures, abundances, and extinction in low- to moderate density plasmas is given, with examples of applications to selected objects. The review concludes by presenting some recent results from HST, HUT, and IUE on UV emission-line spectroscopy of nebulae and active galaxies.

Williams, Robert↗

Toward constraint of ionization-potential depression models in a convergent geometry

We demonstrate the value of inner-shell x-ray absorption spectroscopy for dense-plasma atomic physics and explore the coupling between constraint of the thermodynamic state and constraint of ionization-potential depression models. Synthetic K-shell absorption spectra are generated along a radius from a point-like core and analyzed using different ionization-potential depression models. Within this synthetic analysis framework, we identify plasma conditions (T e = 400 eV, ρ = 40g/cm 3 ) accessible by spherical implosions where K-shell absorption spectra discriminate between models if the material temperature is measured to a precision of 20%. The analysis is extensible to a finite-sized core and can be used to guide future studies of ionization-potential depression, informing material and radiative properties of matter in fusion plasmas and stellar interiors.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Sensitive and single-shot OH and temperature measurements by femtosecond cavity-enhanced absorption spectroscopy

In many low-temperature plasmas (LTPs), the OH radical and temperature represent key properties of plasma reactivity. However, OH and temperature measurements in weakly ionized LTPs are challenging, due to the low concentration and short lifetime of OH and the abrupt temperature rise caused by fast gas heating. To address such issues, this Letter combined cavity-enhanced absorption spectroscopy (CEAS) with femtosecond (fs) pulses to enable sensitive single-shot broadband measurements of OH and temperature with a time resolution of ∼180 ns in LTPs. Such a combination leveraged several benefits. With the appropriately designed cavity, an absorption gain of ∼66 was achieved, enhancing the actual OH detection limit by ∼55× to the 10 11 cm -3 level (sub-ppm in this work) compared with single-pass absorption. Single-shot measurements were enabled while maintaining a time resolution of ∼180 ns, sufficiently short for detecting OH with a lifetime of ∼100 μs. With the broadband fs laser, ∼34,000 cavity modes were matched with ∼95 modes matched on each CCD pixel bandwidth, such that fs-CEAS became immune to the laser-cavity coupling noise and highly robust across the entire spectral range. Also, the broadband fs laser allowed simultaneous sensing of many absorption features to enable simultaneous multi-parameter measurements with enhanced accuracies.

Liu, Ning↗

Spectrally filtered ps–ns emission dynamics of atmospheric-pressure nanosecond pulsed plasmas

The temporal dynamics of atmospheric-pressure nanosecond pulsed plasma discharges in a pin-to-pin electrode configuration are studied using streak-camera line imaging of the interelectrode gap with a time resolution as short as ~25 ps. Discharge emission initiates homogeneously throughout the interelectrode gap with no detectable streamer propagation and then temporally decays in two distinct phases. Plasma emission bands attributed to various electronic transitions are tracked for single discharges in air and N 2 . Spectral filtering of the excited molecular states reveals that the N 2 (C–B) and N 2 (B–A) emission bands evolve in distinct early and late phases, respectively, with a time separation of ~15–20 ns. Furthermore, significant differences in the temporal dynamics of plasma discharges in air and N2 are observed. High levels of excited-state atomic oxygen and NO appear after the initial decay of the N 2 (C) state and coincide primarily with the latter phases of plasma evolution in air environments. From temporal traces of discharge emission, the formation and relaxation timescales of the electronically excited states of N 2 are quantified in pure N2 and air environments with sub-nanosecond resolution. The streak-OES (optical emission spectroscopy) technique enables quantitative time-resolved studies of key chemical species for model validation in ultra-short-pulsed plasmas.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Characterization of Candidate Materials for Remote Recession Measurements of Ablative Heat Shield Materials

A method of remotely measuring surface recession of a material sample in a plasma flow through emission spectroscopy of the post shock layer was characterized through experiments in the NASA Langley HYMETS arc jet facility. Different methods for delivering the seed products into the Phenolic Impregnated Carbon Ablator (PICA) material samples were investigated. Three samples were produced by seeding the PICA material with combinations of Al, Si, HfO2, VB2, Al2O3, SiO2, TiC, HfC, NaCl, and MgCl2 through infusing seed materials into a core of PICA, or through encapsulating seed material in an epoxy disk, mechanically bonding the disk to a PICA sample. The PICA samples seeded with the candidate tracers were then tested at surface temperatures near 2400 K under low pressure air plasma. The emission of Al, Ti, V, Na, and Mg in the post-shock layer was observed in the UV with a high resolution imaging spectrometer viewing the whole stagnation line from the side, and from UV to NIR with a fiber-coupled miniaturized spectrometer observing the sample surface in the wavelength range from 200 nm to 1,100 nm from the front through a collimator. Al, Na, and Mg were found to be emitting in the post-shock spectra even before the recession reached the seeding depth - therefore possibly characterizing the pyrolysis process rather than the recession itself. The appearance of Ti and V emission in the spectra was well correlated with the actual recession which was monitored through a video of the front surface of the sample. The applicability of a seed material as an indicator for recession appears to be related to the melting temperature of the seed material. Future parametric studies will be carried out in low power plasma facilities at the University of Kentucky.

Butler, Bradley D.↗

Compact high repetition rate Thomson parabola ion spectrometer

Here, we present the development of a compact Thomson parabola ion spectrometer capable of characterizing the energy spectra of various ion species of multi-MeV ion beams from >10 20 W/cm 2 laser produced plasmas at rates commensurate with the highest available from any of the current and near-future PW-class laser facilities. This diagnostic makes use of a polyvinyl toluene based fast plastic scintillator (EJ-260), and the emitted light is collected using an optical imaging system coupled to a thermoelectrically cooled scientific complementary metal–oxide–semiconductor camera. This offers a robust solution for data acquisition at a high repetition rate, while avoiding the added complications and nonlinearities of micro-channel plate based systems. Different ion energy ranges can be probed using a modular magnet setup, a variable electric field, and a varying drift-distance. We have demonstrated operation and data collection with this system at up to 0.2 Hz from plasmas created by irradiating a solid target, limited only by the targeting system. With the appropriate software, on-the-fly ion spectral analysis will be possible, enabling real-time experimental control at multi-Hz repetition rates.

47 OTHER INSTRUMENTATION↗

Experimental and computational investigation into the hydrodynamics and chemical dynamics of laser ablation aluminum plasmas

Laser ablation plasma chemistry is governed by a complex interplay between hydrodynamic plasma-gas mixing processes, thermodynamics, and rapid high-temperature chemical reactions. Here, in this work, we investigate the gas-phase oxidation chemistry of ns-laser ablation aluminum plasmas in air using optical spectroscopy combined with advanced multi-physics modeling. Experimental measurements demonstrate the formation of AlO in the plasma plume as early as 1 μs while computational results reveal that several Al x O y species are distributed in the periphery of the plume at even earlier times (<20 ns) in the presence of large temperature gradients and strong shockwaves. Interactions with the ablation crater during rapid plume expansion are shown to initiate vortex formation, followed by mixing dynamics that work to pull AlO into the vortices to react with gas-phase Al to form Al 2 O. Oxygen and several aluminum oxides are simultaneously pulled up through the stem of the fireball, encouraging further intermixing between reacting species and enhanced molecular formation. This work concludes that chemical dynamics in laser ablation plasmas is driven by diffusion processes, concentration gradients, and plume hydrodynamics while strong shockwaves generated during laser ablation do not impede chemical reactions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗