Search NASA⌕ Search

SEARCH · Search NASA

Results for “power consumption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

One-millipound mercury ion thruster

A mercury ion thruster has been developed for efficient operation at the nominal 1-mlb thrust level with a specific impulse of about 3,000 sec and a total power consumption of about 120 W. At a beam voltage of 1,200 V and beam current of 72 mA, the discharge chamber operates with a propellant efficiency of 93.8% at an ion-generation energy of 276 eV/ion. The 8-cm diameter thruster advances proven component technology to assure the capability for thruster operation over an accumulated beam-on time in excess of 20,000 hours with a capability for 10,000 on-off duty cycles. Discharge chamber optimization has combined stable current-voltage characteristics with high performance efficiency by careful placement of the discharge cathode near the location of a magnetic-field zero just upstream of the thruster endplate.

Hyman, J., Jr.↗

A multichannel implantable telemetry system for flow, pressure, and ECG measurements

The design, principles of operation, and performance of an implantable miniaturized (48 cu cm in volume) multiplex telemetry system for simultaneous measurement of up to eight physiological parameters (including cardiovascular data) are described. Integrated circuits are used to reduce the size, complexity, and cost of fabrication. Power consumption is reduced using recently developed complementary MOS devices. PWM technique is selected as it is relatively easy to implement, lends itself to ICs, and provides an accurate means of transmitting data. The system is totally implantable within the chest of a test animal, with no wire penetrating through the skin. It is shown that the described system permits repeated measurement of the physiological effects of a variety of interventions in awake unanesthetized animals.

Fryer, T. B.↗

Miniature carbon dioxide sensor

Infrared absorption spectrometer with dual wave length monochromator has several valuable features: 3.4 by 1.6 inch size; accuracy within plus or minus 5% from 0 to 30 mm Hg; instantaneous and temperature-independent response time; negligible O2 and N2 effects and less than 0.5% water vapor effect; 2.5 W power consumption; no moving parts; and 1.5 and 30 mm Hg CO2 in range.

Bordeaux, J.↗

Development of a magnetically suspended momentum wheel

An engineering model of a magnetically suspended momentum wheel was designed, fabricated, and tested under laboratory conditions. The basic unit consisted of two magnet bearings, a sculptured aluminum rotor, brushless dc spin motor, and electronics. The magnet bearings, utilizing rare-earth cobltrat-samarium magnets were active radially and passive axially. The results of the program showed that momentum wheels with magnetic bearings are feasible and operable, and that magnetic bearings of this type are capable of being used for applications where high capacity, high stiffness, and low power consumption are required. The tests performed developed criteria for improved performance for future designs.

Hamilton, S. B.↗

LTA application of a long trailing wire high speed/low weight reeling system

The successful development of a unique yet simple reeling system for handling long trailing tensile members at high speeds is described. This high speed when combined with the system simplicity, low weight and effective motive power consumption make this reeling system particularly attractive to LTA planners and designers for numerous LTA missions.

Werb, D. F.↗

Biomedical ultrasonoscope

An instrument with a single ultrasonic transducer probe and a linear array of transducer probes permitting three operator modes is described. An 'A' and an 'M' mode scanner were combined with a 'C' mode scanner and a single receiver is used. The 'C' scanner mode enables two-dimensional cross sections of the viewed organ. Video-produced markers enable measurement of the dimensions of the heart. COS/MOS integrated logic circuit components are used to minimize power consumption and permit battery operation.

Lee, R. D.↗

Status of Marshall Space Flight Center solar house

The Marshall Space Flight Center (MSFC) solar facility is described herein, and test results obtained from late May 1974 to September 1974 are discussed. This facility was assembled to provide operational experience in the utilization of solar energy for heating and cooling buildings. The major subsystems are the solar collector, the energy storage tank, the simulated living space, the air conditioning and heating subsystems, and the controls. These subsystems are described with emphasis placed on major results and conclusions. A cursory evaluation of the system for cooling is given from energy and power consumption viewpoints. This data evaluation indicates the current system is capable of supplying 50 per cent of the thermal energy required to drive the air conditioner. A preliminary evaluation of winter data indicates that more than 90 per cent of the heating required can be provided by the solar system.

Humphries, W. R.↗

Differential multi-MOSFET nuclear radiation sensor

Circuit allows minimization of thermal-drift errors, low power consumption, operation over wide dynamic range, improved sensitivity and stability with metaloxide-semiconductor field-effect transistor sensors.

Deoliveira, W. A.↗

Study of a Vuilleumier cycle cryogenic refrigerator for detector cooling on the limb scanning infrared radiometer

A program to detect and monitor the presence of trace constituents in the earth's atmosphere by using the Limb Scanning Infrared Radiometer (LSIR) is reported. The LSIR, which makes radiometric measurements of the earth's limb radiance profile from a space platform, contains a detector assembly that must be cooled to a temperature of 65 + or - 2 K. The feasibility of cooling the NASA-type detector package with Vuilleumier (VM) cryogenic refrigerator was investigated to develop a preliminary conceptual design of a VM refrigerator that is compatible with a flight-type LSIR instrument. The scope of the LSIR program consists of analytical and design work to establish the size, weight, power consumption, interface requirements, and other important characteristics of a cryogenic cooler that would meet the requirements of the LSIR. The cryogenic cooling requirements under the conditions that NASA specified were defined. Following this, a parametric performance analysis was performed to define the interrelationships between refrigeration characteristics and mission requirements. This effort led to the selection of an optimum refrigerator design for the LSIR mission.

Russo, S. C.↗

Feasibility study of the design of Bi Ra Systems, Incorporated model 5301, 5101, and 3222 CAMAC modules for space use

Cost estimates are determined for redesigned modules. Consideration is given to incorporation of NASA approved components, component screening and documentation, as well as reduced power consumption. Results show that r designed modules will function reliably in a space environment of 50 C and withstand greater than 15 G's of random vibration between 40 Hz and 400 Hz.

Biswell, L.↗

Self-navigating robot

Rangefinding equipment and onboard navigation system determine best route from point to point. Research robot has two TV cameras and laser for scanning and mapping its environment. Path planner finds most direct, unobstructed route that requires minimum expenditure of energy. Distance is used as measure of energy expense, although other measures such as time or power consumption (which would depend on the topography of the path) may be used.

Thompson, A. M.↗

Active spacecraft potential control system selection for the Jupiter orbiter with probe mission

It is shown that the high flux of energetic plasma electrons and the reduced photoemission rate in the Jovian environment can result in the spacecraft developing a large negative potential. The effects of the electric fields produced by this charging phenomenon are discussed in terms of spacecraft integrity as well as charged particle and fields measurements. The primary area of concern is shown to be the interaction of the electric fields with the measuring devices on the spacecraft. The need for controlling the potential of the spacecraft is identified, and a system capable of active control of the spacecraft potential in the Jupiter environment is proposed. The desirability of using this system to vary the spacecraft potential relative to the ambient plasma potential is also discussed. Various charged particle release devices are identified as potential candidates for use with the spacecraft potential control system. These devices are evaluated and compared on the basis of system mass, power consumption, and system complexity and reliability.

Beattie, J. R.↗

Investigation and evaluation of shuttle/GPS navigation system

Iterative procedures were used to analyze the performance of two preliminary shuttle/GPS navigation system configurations: an early OFT experimental system and a more sophisticated system which consolidates several separate navigation functions thus permitting net cost savings from decreased shuttle avionics weight and power consumption, and from reduced ground data processing. The GPS system can provide on-orbit navigation accuracy an order of magnitude better than the baseline system, with very adequate link margins. The worst-case link margin is 4.3 dB. This link margin accounts for shuttle RF circuit losses which were minimized under the constraints of program schedule and environmental limitations. Implicit in the link analyses are the location trade-offs for preamplifiers and antennas.

Nilsen, P. W.↗

Technology advancement of the static feed water electrolysis process

A program to advance the technology of oxygen- and hydrogen-generating subsystems based on water electrolysis was studied. Major emphasis was placed on static feed water electrolysis, a concept characterized by low power consumption and high intrinsic reliability. The static feed based oxygen generation subsystem consists basically of three subassemblies: (1) a combined water electrolysis and product gas dehumidifier module; (2) a product gas pressure controller and; (3) a cyclically filled water feed tank. Development activities were completed at the subsystem as well as at the component level. An extensive test program including single cell, subsystem and integrated system testing was completed with the required test support accessories designed, fabricated, and assembled. Mini-product assurance activities were included throughout all phases of program activities. An extensive number of supporting technology studies were conducted to advance the technology base of the static feed water electrolysis process and to resolve problems.

Schubert, F. H.↗

Use of a multi-look unfocussed SAR processor on spacecraft

Two methods of processing signals from a multi-look unfocussed synthetic-aperture radar are considered. A saving in the processor complexity is achieved in comparison to a fully focussed SAR system at the expense of slightly greater clutter levels and poorer along-track resolution. In addition, lower power consumption enables the unfocussed processor to increase the number of looks to compensate in part for the reduced resolution.

Fong, R. K. T.↗

Variable-temperature cryogenic trap for the separation of gas mixtures

The paper describes a continuous variable-temperature U-shaped cold trap which can both purify vacuum-line combustion products for subsequent stable isotopic analysis and isolate the methane and ethane constituents of natural gases. The canister containing the trap is submerged in liquid nitrogen, and, as the gas cools, the gas mixture components condense sequentially according to their relative vapor pressures. After the about 12 min required for the bottom of the trap to reach the liquid-nitrogen temperature, passage of electric current through the resistance wire wrapped around the tubing covering the U-trap permits distillation of successive gas components at optimal temperatures. Data on the separation achieved for two mixtures, the first being typical vacuum-line combustion products of geochemical samples such as rocks and the second being natural gas, are presented, and the thermal behavior and power consumption are reported.

Des Marais, D. J.↗

Report on monitoring and support instruments for solar physics research from Spacelab

The Quick Reaction and Special Purpose Facility Definition Team for Solar Physics Spacelab Payloads examined a variety of instruments to fulfill the following functions: (1) solar physics research appropriate to Spacelab, (2) correlative data for research in such fields as aeronomy, magnetospheric physics, ionospheric physics, meteorology and climatology, (3) target selection for activity alert monitoring and (4) pointing accuracy monitoring of Spacelab platforms. In this examination the team accepted a number of restrictions and qualifications: (1) the cost of such instruments must be low, so as not to adversely impact the development of new, research class instrumentation in the early Spacelab era; (2) the instruments should be of such a size that they each would occupy a small fraction of a pointing system, and (3) the weight and power consumption of the instruments should also be small. With these restrictions, the instruments chosen are: the visible light telescope and magnetograph, the extreme-ultraviolet telescope, and the solar irradiance monitor.

Source record↗