Effects of vibration and shock on the performance of gas-bearing space-power Brayton cycle turbomachinery. Part 4: Suppression of rotor-bearing system vibrations through flexible bearing support damping

A bearing damper, operating on the support flexure of a pivoted pad in a tilting-pad type gas-lubricated journal bearing, has been designed, built, and tested under externally-applied random vibrations. The NASA Brayton Rotating Unit (BRU), a 36,000 rpm, 10-Kwe turbogenerator had previously been subjected in the MTI Vibration Test Laboratory to external random vibrations, and vibration response data had been recorded and analyzed for amplitude distribution and frequency content at a number of locations in the machine. Based on data from that evaluation, a piston-type damper was designed and developed for each of the two flexibly-supported journal bearing pads (one in each of the two three-pad bearings). A modified BRU, with dampers installed, has been re-tested under random vibration conditions. Root-mean-square vibration amplitudes were determined from the test data, and displacement power spectral density analyses have been performed. Results of these data reduction efforts have been compared with vibration tolerance limits. Results of the tests indicate significant reductions in vibration levels in the bearing gas-lubricant films, particularly in the rigidly-mounted pads. The utility of the gas-lubricated damper for limiting rotor-bearing system vibrations in high-speed turbomachinery has thus been demonstrated.

Tessarzik, J. M.↗

Design and Modeling of an 80 bar Oxy-Combustor for Direct Fired Supercritical CO2 Applications

As supercritical CO2 power cycles for fossil energy power generation continue to generate interest, there are significant issues and unanswered questions regarding injector design, flame stabilization, wall heat transfer, CO emissions, combustion dynamics and other combustion phenomenon. For natural gas, direct-fired cycles with carbon capture it is believed that Computational Fluid Dynamics (CFD) modeling will play an essential role in the combustor design process. To accurately model turbulent reacting flows at these unique conditions, experimental data is needed to validate CFD codes and sub-models and is currently lacking at conditions relevant for these cycles. This paper presents the conceptual design and CFD simulations of an experimental 80 bar oxy-combustion facility and test article currently under construction at NETL. The facility is targeted towards the testing of a single injector, direct-fired sCO2 combustor at the 100 kW thermal output level. While these conditions do not reflect the actual Allam cycle operating conditions (300 bar) they are viewed as a stepping stone in the model validation process at supercritical conditions. Reynolds Averaged Navier-Stokes as well as Large Eddy Simulation are used to model the turbulent combustion process and aid in the design of the combustor and injector. Process parameters including oxidizer preheat temperature and combustor flowrate are investigated.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Testing of a 40-kWth Counterflow Particle-Supercritical Carbon Dioxide Narrow-Channel, Fluidized Bed Heat Exchanger

Particle-based primary heat exchangers (HXs) must deliver sCO2 fluid temperatures above 700°C to couple particle-based concentrating solar receivers and thermal energy storage (TES) sub-systems with efficient sCO2 power cycles. Particle-sCO2 HX designs have struggled to meet DOE cost targets (≤ $150/kWth) due to the amount of expensive nickel alloys necessary for manufacturing full-scale, particle-sCO2 HXs. Our team has demonstrated that mild bubbling fluidization of falling particles in a counterflow narrow-channel fluidized bed can reduce required HX surface area and thus, costs by increasing particle-wall heat transfer coefficients hT,w > 800 W m-2 K-1. This paper reports on the fabrication and testing of a stainless steel, particle-sCO2 HX with 12 fluidized-bed channels approximately 10.5 mm deep spaced between diffusion-bonded, micro-channel sCO2 plates. The HX with a core length of ≈0.56 m is fed with CARBOBEAD HSP particles through a short, fluidized freeboard zone just above the core. Testing to date in the National Solar Thermal Test Facility (NSTTF) at Sandia National Laboratories has shown that parallel bed fluidization maintains uniform particle inventory across the instrumented channels. Heat transfer thermal duty between the particle and sCO2 flows exceeds 30 kWth with sCO2 inlet temperatures of 200ºC and particle inlet temperatures up to 440ºC and mass flow rates of 0.2 kg s-1 fluidized by counterflowing gas flow rates of 0.005 kg s-1. Tests at higher particle and sCO2 inlet temperatures (600ºC and 400ºC respectively) are targeted to achieve > 40 kWth with model-predicted overall heat transfer coefficients U > 400 W m-2 K-1.

14 SOLAR ENERGY↗

Measurements of Density and Sound Speed in Mixtures Relevant to Supercritical CO2 Cycles

Abstract The objective of this research is to validate properties of mixtures relevant to supercritical carbon dioxide (sCO2) power cycles. Direct-fired sCO2 cycles are a promising technology for the future power generation systems. The working fluid of sCO2 cycles will be near and above critical point of CO2. One of the challenges is that the simulation of mixtures should consider real gas behavior. Expected operating conditions of Allam cycles reach up to 300 bar and 1000 °C. Characterizing the mixtures at the extreme conditions is an important issue in current researches and industrial applications. Thermophysical properties of mixtures may be beyond the valid range of the widely used database such as NIST REFPROP. Experimental data of mixture properties in the literature are limited which is necessary to develop high-fidelity design tools for sCO2 power cycles. We measured the density and sound speed of several multi-component mixtures. A temperature-controlled high-pressure test cell was used for the density measurements. Sound speed was measured by resonant frequency detection using an external speaker and a piezoelectric pressure sensor. Mixtures studied in this work include carbon dioxide, methane, oxygen, and water vapor. Properties of pure CO2 were measured to show the validity of our technique. Compositions were selected to be close to frozen mixtures at the inlet, mid-progress, and exhaust conditions of a model sCO2 combustor in the previous numerical simulation work. Corresponding reaction progress variables (RPV) were RPV = 0, 0.5, and 1. Temperature and pressure conditions of experiments are 310–450 K and 0–150 bar. In our study, density and sound speed from the NIST REFPROP database agree with experimental measurements within the range of our measurement uncertainties.

Energy & Fuels↗

Optimization of Dimensions of Smooth and Twisted-Tape-Inserted Tubes for Heat Transfer with NaCl/KCl/MgCl 2 Molten Salts by Principle of Entropy Generation Minimization

The entropy generation minimization principle is used as the criterion to optimize the flow and heat transfer of solar collectors and heat exchangers that use molten salts NaCl–KCl–MgCl 2 and KCl–MgCl 2 . The Gnielinski correlation for the Nusselt number versus Reynolds number, as well as the Moody friction factor given by Petukhov, was used for the calculation of the convective heat transfer coefficient and pressure loss due to friction in smooth tubes. For twisted-tap-inserted tube, equations of Nu and friction factor provided by Manglik and Bergles were used. The objective function, the entropy generation rate of the heat transfer system, was expressed as the function of Reynolds number, Prandtl number, heating flux, tube diameter, etc. As a result of the analysis, the optimum Reynolds number was determined and thereby to determine the optimum Nusselt number, convective heat transfer coefficient, friction factor, and tube diameter, which also allows the calculation of optimum flow velocity. The analysis was conducted in the fluid temperature range of 500–700 °C, which covers the operation temperature for supercritical CO 2 power cycles in concentrated solar power (CSP) system. Here, optimized results from the smooth tube and twisted-tap-inserted tube are compared, which is important to the design of solar receivers for CSP systems.

14 SOLAR ENERGY↗

Computer program for thermodynamic analysis of open cycle multishaft power system with multiple reheat and intercool

A computer program to analyze power systems having any number of shafts up to a maximum of five is presented. On each shaft there can be as many as five compressors and five turbines, along with any specified number of intervening intercoolers and reheaters. A recuperator can be included. Turbine coolant flow can be accounted for. Any fuel consisting entirely of hydrogen and/or carbon can be used. The program is valid for maximum temperatures up to about 2000 K (3600 R). The system description, the analysis method, a detailed explanation of program input and output including an illustrative example, a dictionary of program variables, and the program listing are explained.

Glassman, A. J.↗

Closed cycle MHD power generation experiments in the NASA Lewis Facility

Many modifications were made in the MHD facility. These include a redesign of the MHD duct interior, addition of mixing bars, increased electrical isolation of all the high temperature components from each other and from ground, and experimentation with various cesium seed vaporization and injection techniques. With the exception of the cesium system which needs further improvement the above modifications were quite successful and resulted in improvements in generator performance. The facility was run for a total of 400 hours in the past year, with 70 hours of this operation at temperatures of 2000 K or more with hot generator walls. With the exception of replacing one cracked brick in the MHD channel no repairs were required in the high temperature loop components for the duration of these tests. Uniform Faraday and Hall voltage profiles were obtained and the Faraday open circuit voltage varied from 90 to 100 percent of the ideal uBh. The magnitudes of the measured parameters are: Faraday open circuit voltage approximately 70 V, total Faraday current approximately 20 A, Hall voltage approximately 250 V, power output approximately 300 W, and power density .036 W/cu cm.

Sovie, R. J.↗

Results of closed cycle MHD power generation test with a helium-cesium working fluid

The cross sectional dimensions of the MHD channel in the NASA Lewis closed loop facility were reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 160,000 n/M2, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/M. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/M were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/M3 were obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those previously reported for the M = 0.2 channel.

Sovie, R. J.↗

Results of closed cycle MHD power generation tests with a helium-cesium working fluid

The cross-sectional dimensions of the MHD channel in the NASA Lewis closed loop facility have been reduced to 3.8 x 11.4 cm. Tests were run in this channel using a helium-cesium working fluid at stagnation pressures of 1.6 x 10 to the 5th N/sq m, stagnation temperatures of 2000-2060 K and an entrance Mach number of 0.36. In these tests Faraday open circuit voltages of 200 V were measured which correspond to a Faraday field of 1750 V/m. Power generation tests were run for different groups of electrode configurations and channel lengths. Hall fields up to 1450 V/m were generated. Power extraction per electrode of 183 W and power densities of 1.7 MW/cu m have been obtained. A total power output of 2 kW was generated for tests with 14 electrodes. The power densities obtained in this channel represent a factor of 3 improvement over those reported for the m = 0.2 channel at the last EAM Symposium.

Sovie, R. J.↗

Design and calculated performance and cost of the ECAS Phase II open cycle MHD power generation system

A 2000 MWe MHD/steam plant for central station applications has been designed and costed as part of the Energy Conversion Alternatives Study (ECAS). This plant is fueled by Illinois No. 6 coal, rejects heat through mechanical draft wet cooling towers, and includes coal processing equipment, seed reprocessing, electrical inversion of the MHD generator output and emission controls to current EPA standards. It yields an estimated overall efficiency of 0.483 (7066 Btu/kWe-hr), a capital cost of $718 per kWe (1975 dollars), and a cost of electricity at 65% capacity factor of 32 mills per kWe-hr. If the assumed life and reliability could be achieved with these performance parameters, the MHD system should prove attractive.

Harris, L. P.↗

Evaluation of the ECAS open cycle MHD power plant design

The Energy Conversion Alternatives Study (ECAS) MHD/steam power plant is described. The NASA critical evaluation of the design is summarized. Performance of the MHD plant is compared to that of the other type ECAS plant designs on the basis of efficiency and the 30-year levelized cost of electricity. Techniques to improve the plant design and the potential performance of lower technology plants requiring shorter development time and lower development cost are then discussed.

Seikel, G. R.↗

Contact integrity testing of stress-tested silicon terrestrial solar cells

A test procedure was developed and applied to terrestrial silicon solar cells in order to determine the effect of accelerated environmental and time-temperature aging on metal contact integrity. Quantities of cells of four different manufacturers were given the contact integrity test after being subjected to accelerated stress tests that included forward bias-temperature, thermal cycle and thermal shock, power cycle, and bias-temperature humidity tests at two temperature-humidity levels. Significant effects due to certain stress tests were found for some cell types. It is concluded that cells fabricated using plated nickel/solder metallization showed significantly more serious contact integrity degradation than silver-metallized cells.

Prince, J. L.↗

System controls challenges of hypersonic combined-cycle engine powered vehicles

Hypersonic aircraft with air-breathing engines have been described as the most complex and challenging air/space vehicle designs ever attempted. This is particularly true for aircraft designed to accelerate to orbital velocities. The propulsion system for the National Aerospace Plane will be an active factor in maintaining the aircraft on course. Typically addressed are the difficulties with the aerodynamic vehicle design and development, materials limitations and propulsion performance. The propulsion control system requires equal materials limitations and propulsion performance. The propulsion control system requires equal concern. Far more important than merely a subset of propulsion performance, the propulsion control system resides at the crossroads of trajectory optimization, engine static performance, and vehicle-engine configuration optimization. To date, solutions at these crossroads are multidisciplinary and generally lag behind the broader performance issues. Just how daunting these demands will be is suggested. A somewhat simplified treatment of the behavioral characteristics of hypersonic aircraft and the issues associated with their air-breathing propulsion control system design are presented.

Morrison, Russell H.↗

Test Results from a High Power Linear Alternator Test Rig

Stirling cycle power conversion is an enabling technology that provides high thermodynamic efficiency but also presents unique challenges with regard to electrical power generation, management, and distribution. The High Power Linear Alternator Test Rig (HPLATR) located at the NASA Glenn Research Center (GRC) in Cleveland, OH is a demonstration test bed that simulates electrical power generation from a Stirling engine driven alternator. It implements the high power electronics necessary to provide a well regulated DC user load bus. These power electronics use a novel design solution that includes active rectification and power factor control, active ripple suppression, along with a unique building block approach that permits the use of high voltage or high current alternator designs. This presentation describes the HPLATR, the test program, and the operational results.

Birchenough, Arthur G.↗