Search NASA⌕ Search

SEARCH · Search NASA

Results for “power flow initialization”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 289 records · Page 16

Accelerating Subsurface Transport Simulation on Heterogeneous Clusters

Reactive transport numerical models simulate chemical and microbiological reactions that occur along a flowpath. These models have to compute reactions for a large number of locations. They solve the set of ordinary differential equations (ODEs) that describes the reaction for each location through the Newton-Raphson technique. This technique involves computing a Jacobian matrix and a residual vector for each set of equation, and then solving iteratively the linearized system by performing Gaussian Elimination and LU decomposition until convergence. STOMP, a well known subsurface flow simulation tool, employs matrices with sizes in the order of 100x100 elements and, for numerical accuracy, LU factorization with full pivoting instead of the faster partial pivoting. Modern high performance computing systems are heterogeneous machines whose nodes integrate both CPUs and GPUs, exposing unprecedented amounts of parallelism. To exploit all their computational power, applications must use both the types of processing elements. For the case of subsurface flow simulation, this mainly requires implementing efficient batched LU-based solvers and identifying efficient solutions for enabling load balancing among the different processors of the system. In this paper we discuss two approaches that allows scaling STOMP's performance on heterogeneous clusters. We initially identify the challenges in implementing batched LU-based solvers for small matrices on GPUs, and propose an implementation that fulfills STOMP's requirements. We compare this implementation to other existing solutions. Then, we combine the batched GPU solver with an OpenMP-based CPU solver, and present an adaptive load balancer that dynamically distributes the linear systems to solve between the two components inside a node. We show how these approaches, integrated into the full application, provide speed ups from 6 to 7 times on large problems, executed on up to 16 nodes of a cluster with two AMD Opteron 6272 and a Tesla M2090 per node.

GPU↗

Experiment on large scale plume interaction with a stratified gas environment resembling the thermal activity of a autocatalytic recombiner

Computational Fluid Dynamics codes (CFD) are increasingly being used to simulate containment conditions after various transient accident scenarios. Consequently, the reliability of such codes must be tested against experimental data. Such validation experiments related to gas mixing and hydrogen transport within containment compartments addressing the effect of heat source are presented in this paper. The experiments were conducted in the large-scale thermal-hydraulics PANDA facility located at the Paul-Scherrer-Inst. (PSI) in Switzerland, in the frame of the OECD/SETH-2 project. A 10 kW electric heater simulating the thermal activity of the autocatalytic recombiner was activated at full power in a containment vessel at the top of which a thick helium layer is initially present. The hot plume interacts with the bottom of the helium layer which is slowly eroded until complete break up at 1350 s. After final erosion of the layer a strong temperature and concentration gradient is maintained in the vessel below the heater inlet as well as in the adjacent vessel below the interconnecting pipe. A detailed characterization of the operating heater suggests the presence of cold gas ingress at the outlet that affects the flow in the chimney. This can be of concern if present in a real PAR unit. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Isolation and characterization of 13 microsatellite loci for the Neotropical otter, Lontra longicaudis, by next generation sequencing

The Neotropical otter, Lontra longicaudis, is an ecologically important species for freshwater ecosystems that is threatened due to habitat destruction and hunting. However, there is limited information regarding the population sizes, genetic diversity, genetic structure and gene flow of the species, which is crucial for the elaboration of conservation plans. The aim of this study was to isolate and characterize microsatellites for L. longicaudis, using Illumina paired-end-sequencing. Initial amplification tests were performed in 48 loci, out of which, 13 yielded high-quality PCR products and thus were further evaluated. Genetic diversity and discrimination power of the 13 microsatellite loci was assessed using 19 non-invasive samples collected in the Jamapa basin in Veracruz, Mexico and blood samples from six captive individuals. All loci were polymorphic, the number of alleles per locus ranged from 4 to 10, the observed heterozygosity from 0.21 to 0.69, and the expected heterozygosity from 0.55 to 0.82. The combined set of 13 microsatellites showed a high power for discriminating among individuals (probability of identity P ID = 1.551 × 10 -16 ) and among siblings (probability of identity of siblings P IDSIB = 3.349 × 10 -06 ). A combination of nine loci are sufficient to discriminate among siblings with high confidence (P IDSIB < 0.0001). The new set of microsatellites for the Neotropical otter reported here will provide a useful genetic tool to assess population genetic patterns and ecological parameters of the species.

59 BASIC BIOLOGICAL SCIENCES↗

Additive Manufacturing of MITL's and Convolutes

Stockpile stewardship requires accurate and predictive models relying on the generation of extreme environments which is both incredibly difficult and profoundly necessary. Next generation pulsed power facilities (NGPPF), where these environments are created, may require a paradigm shift in equipment engineering/manufacture to fulfill this need. Therefore, this research aims to investigate the limitations, capabilities and efficacy of leveraging advancements in the field of additive manufacturing (AM) in order to produce novel power flow components for NGPPFs. This work focused on commercial 3D metal AM equipment producing several prototypes addressing prescient needs/shortcomings, and a technique wherein a lightweight polymer core is metalized. Ultimately, commercial 3D metal AM is considered a viable path forward but would require a sizeable investment and does not currently support the scale and complexity necessary for NGPPFs. Moreover, initial results from our composite technique are promising and is considered a realizable path forward given further investigation.

42 ENGINEERING↗

Inflow Characterization for Marine and Hydrokinetic Energy Devices. FY-2010 Annual Progress Report

Marine and Hydro Kinetic devices (MHK) are being widely studied as a source of renewable energy. The Marrowstone Island site is a potential location for installing MHK devices because the tidal currents observed that are sufficient for power generation. In order to quantify the effects of turbulence on MHK devices and the surrounding environment at this site, a prelimi- nary fluid flow field study was conducted here by the Pacific Northwest National Lab (PNNL) in collaboration with the Applied Physics Lab at the University of Washington (APL-UW). This study entailed continuous The Acoustic Doppler Velocimetry (ADV), Acoustic Doppler Current Profiler (ADCP) and Conductivity, Temperature and Depth (CTD) measurements from May 4, 2010 to May 22, 2010, in order to obtain information about turbulence effects during different tidal conditions. The instruments used for collecting the above measurements were deployed at the Marrowstone site using a R/V Jack Robertson provided by the University of Washington (APL-UW). All the measurements were taken at the site with an average depth of 22 m below the sea surface. ADV acquired velocity data at 32 Hz sampling frequency at 4.6 m above the seabed, and ADCP acquired velocity profile data at a sampling frequency of 2 Hz, from a height of 2.6 m above the seabed to the surface with a bin resolution of 0.5 m. The ADV and ADCP measurements showed that the horizontal velocity had a turbulence intensity of 10%. Further- more, the spectral analysis from ADV measurements showed that the flow is fully turbulent with -5/3 slope in the inertial sub-range of the spectra. Moreover, the temporal-frequency analysis showed presence of ”eddies” at high frequencies. These preliminary studies provided initial flow field and site characteristics, showed the limitations of the instruments used and highlighted changes that need to be made in the experimental setup for deployment in FY-2011 studies.

13 HYDRO ENERGY↗

Development of MOSCATO: A CFD-Level Electrochemistry and Corrosion Simulator for Molten Salt Systems

For both coolant and fueled variants of molten salt reactors (MSRs), the corrosion of structural materials is a significant challenge. The corrosion stems from chemical and electrochemical reactions initiated by fissile material, fission products, and impurities in the salt. Lower-fidelity models rely on empirical correlations for mass transfer, simplified lumped temperature profiles, and similar assumptions. They do not capture detailed spatial variations in complex geometries, creating the need for high-fidelity modeling to bridge this gap.As we approach the demonstration and possible deployment of MSRs in this decade, the development of a high-fidelity, high-performance simulator becomes imperative. To simulate the complex electrochemical environment and corrosion within molten salt systems, we have developed the Molten Salt Chemistry And TranspOrt (MOSCATO) code. This endeavor is comprised of three essential components. First, mass transfer equations are coupled with the Navier-Stokes equations in order to account for the transport of species in the salt. Second, the diffusion of alloy constituents, such as Cr, Fe, Ni, etc. is simulated within the structural metals. Third, the alloy and salt domains are coupled to account for the heterogeneous chemical and electrochemical reactions that occur at the salt-alloy interface.MOSCATO manages all three components within the framework of the highly scalable, open-source spectral element method computational fluid dynamics code Nek5000/NekRS. This integration enables MOSCATO to harness the immense computational power of modern high-performance computing resources, ensuring both high fidelity and computational speed.In addition to code development, we have initiated a comprehensive verification and validation campaign, utilizing data from diverse sources. First, MOSCATO's electrochemical solver was verified with reference numerical data. Then validation occurred against experiments: one of a thermal galvanic cell and the other for corrosion in flowing molten salt of FLiNaK (LiF-NaF-KF). This campaign verified and validated MOSCATO as a reliable tool for simulating electrochemical environments and corrosion in molten salt systems.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Developments on two lithium vapor-box linear test-stand experiments

The lithium vapor-box divertor is a possible fusion power exhaust solution.It uses condensation pumping to create a gradient of vapor density in a divertor slot; this should allow a stable detachment front without active feedback.As initial explorations of the concept, two test stands which take the form of three connected cylindrical stainless steel boxes are being developed: one without plasma at PPPL, to test models of lithium evaporation and flow; and one for the linear plasma device Magnum-PSI (at DIFFER in Eindhoven, The Netherlands) to test the ability of a lithium vapor cloud to induce volumetric detachment and redistribute the plasma power.The first experiment uses boxes with diameters of 6 cm, joined by apertures with diameters of 2.2 cm. Up to 1 g of Li is placed in one box, which is heated to up to 600 degrees C. The Li evaporates, then flows to and condenses in the two other, cooler boxes over several minutes. The quantity of Li transported is assessed by weighing the boxes before and after the heating cycle, and is compared to the quantity predicted to flow for the box at its measured temperature using a Direct Simulation Monte Carlo code, SPARTA. With good experimental conditions, the two values agree to within 15%.The experiment on Magnum-PSI is in the conceptual design stage.The design is assessed by simulations using the code B2.5-Eunomia.They show that when the hydrogen-ion plasma beam, with n_e = 4e20 per cubic meter, T_e = 1.5 eV, and r = 1 cm, is passed through a 16 cm long, 12 Pa, 625 degree C Li vapor cloud, the plasma heat flux and pressure on the target are significantly reduced compared to the case without Li.With the Li present, the plasma is cooled by excitation of Li neutrals followed by radiation until it volumetrically recombines, lowering the heat flux from 3.7 MW/m^2 to 0.13 MW/m^2, and the pressure is reduced by 93%, largely by collisions of hydrogen ions with neutral Li.

divertor↗

Subtask 2.6 – Optimization of Aerosol Mitigation Technology for Postcombustion CO 2 Capture

Growing concerns over the impact of CO 2 emissions from combustion sources on global climate change have prompted numerous research and development projects aimed at developing cost-effective technologies for CO 2 capture. One family of technologies being demonstrated at pilot and full scale globally is postcombustion CO 2 capture (PCCC) systems that employ amine-based solvents. The captured CO 2 can be compressed and permanently stored underground or used for enhanced oil recovery (EOR). The proximity of North Dakota’s lignite-fired fleet of power plants to potential CO 2 storage options creates a unique atmosphere for PCCC within the state. However, the aerosols present in lignite flue gas present a challenge for large-scale PCCC at North Dakota power plants. Aerosols can negatively impact the long-term performance of amine-based solvents for CO 2 capture. Amine-based solvents are volatile, and aerosols provide nucleation sites where amine vapors can condense. Because aerosols cannot be easily captured at the column outlet using conventional technologies, the amine-laden aerosols escape the system and lead to accelerated solvent losses. Moreover, aerosol components can chemically react with amines to form degradation products that can permanently deactivate the amine, cause fouling, and lead to hazardous emissions. Many of the elements that have been shown to catalyze solvent degradation are present in lignite coals and can exacerbate solvent replacement economics. Understanding this issue is critical to the implementation of solvent-based CO 2 capture systems as applied to lignite-fired generation systems. The Energy & Environmental Research Center (EERC) designed and carried out this project to optimize aerosol mitigation technology for PCCC at a lignite-fired power plant. To meet the goal of this project, the following objectives were identified: Determine the effectiveness of a wet electrostatic precipitator (WESP) on collection of aerosols at a low-rank coal-fired power station. Determine the impact of aerosols on the efficiency and degradation products of amine-based carbon capture systems fired with low-rank fuels. Work was conducted at Minnkota Power Cooperative’s (MPC’s) Milton R. Young (MRY) Station Unit 2 using a slipstream of flue gas from the outlet of the plant’s flue gas desulfurization (FGD) unit. To gather initial data for sizing and specifying a WESP for this system, a temporary pilot-scale WESP was rented and installed on-site. Several different conditions were tested to examine the impact of flow rate, voltage, and current on WESP performance. The WESP was effective at removing large particulate (>200 nm) but caused an increase in fine particulate (<75 nm). Fine particulate material at the inlet and outlet of the WESP was collected, analyzed, and showed that crystalline sulfates carried over from the plant’s FGD unit were being converted to fine aerosols and SO 2 was being converted to SO 3 through the WESP. Additionally, the high moisture content of the flue gas stream at this sample location also contributed to an overall increase in aerosol mass under some of the test conditions. Using the results from the rented WESP, the project team installed a smaller-scale WESP upstream of the EERC’s slipstream CO 2 capture system. Flue gas was routed through a pilot-scale FGD unit to remove SO 2 to very low levels (~1 ppm) and then through a direct contact cooler (DCC) to further cool the gas and to remove moisture. The gas exiting the DCC was then routed through the new WESP before passing to the CO 2 absorber columns. Fluor’s amine-based solvent was used to scrub CO 2 from the slipstream through a set of two absorber columns. The rich solvent was regenerated in a stripper column by heating to drive off captured CO 2 . The system operated using a catch-and-release method where the CO 2 was separated to provide data on the process, but the captured CO 2 was released back into the host site stack. Aerosols and sulfur species were measured at multiple locations throughout the pilot-scale system. The inlet FGD and DCC removed much of the particulate matter and gaseous sulfur upstream of the WESP. With this configuration, the WESP achieved >95% particulate capture. The new WESP did not show any of the increases in SO 3 or other aerosol species that had been consistently observed with the larger-scale WESP installed immediately downstream of the plant’s full-scale FGD unit. Particulate samples captured and analyzed from the WESP inlet did not show any presence of crystalline sulfate materials, indicating that the pilot-scale FGD and DCC were efficient at reducing carryover from the plant’s full-scale FGD unit. A set of parametric tests were conducted on the new WESP to assess the impacts of flow rate, voltage, number of online WESP fields, and gas-phase sulfur content on aerosol and sulfur transformations. The results showed that the WESP performed similarly well at all sets of conditions. Sulfur and particulate matter exiting the WESP were further reduced through the absorber column as the amine-based solvent captured some of the residual contaminants. Solvent analysis showed that these species were slowly concentrating in the solvent over the duration of the test. When the WESP was taken offline and the sulfur slip through the FGD allowed to rise, the sulfate content in the solvent rose sharply, showing that the extra FGD and WESP were effective at reducing sulfate and cation uptake. This would be expected to extend amine-based solvent life by slowing the formation of heat-stable salts and other degradation products. This subtask was cofunded through the EERC–U.S. Department of Energy Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233. Nonfederal funding was provided by the North Dakota Industrial Commission and MPC.

01 COAL, LIGNITE, AND PEAT↗

Titanium-Cerium Electrode-Decoupled Redox Flow Batteries Integrated With Fossil Fuel Assets For Load-Following, Long-Duration Energy Storage

Operation of fossil plants at partial capacity with frequent cycling results in decreased efficiency, increased emissions and increased wear and maintenance. The objective of this project is to advance the integration of a titanium-cerium electrode-decoupled redox flow battery (RFB) system with conventional fossil-fueled power plants through technical and economic system-level studies and component scale-up and R&D. The Ti-Ce chemistry has a pathway to meet the DOE cost targets of $\$$100/kWh and $\$$0.05/kWh-cycle owing to the use of low-cost, earth abundant elemental actives and incorporation of inexpensive carbon felt electrodes and non-fluorinated anion exchange membrane (AEM) separators. The initial unit cell design was scaled up, with some modifications made to improve ease of manufacturing, from 25 cm 2 cell area to 400 cm 2 . Electrochemical tests demonstrated operation at a current density up to 50 mA/cm 2 , which is on par with other commercial RFB offerings. Furthermore, the Ti-Ce technology developed by WashU was evaluated and tested by industrial team partner, Giner, Inc., in their modular 3-cell stack. Several cell design modifications and alternate component material selections were successfully implemented to accommodate this chemistry while reducing polarization and leakage. Results from stack testing show high columbic efficiency and indicate that further optimization of cell compression and components will lead to successful operation of the Ti-Ce ED-RFB over longer duration at the multi-cell stack level. Engineering and cost analysis showed that an RFB system with power output on the order of 100 MW and with a charge/discharge duration of approx. 12 hours is the most cost effective for integration with fossil plants. At this scale, projected cycling of fossil fuel power plants can be significantly reduced. The use of a storage system is shown to reduce the fossil plant standalone cost of electricity by $\$$7/MWh, through increased capacity factor and improved average efficiency, in the scenario of high penetration of renewable power.

20 FOSSIL-FUELED POWER PLANTS↗

Submersible Multistage Centrifugal Pump for Versatile Test Reactor Cartridge Test Loop

Submersible multistage centrifugal pumps are ideal for pumping in narrow confined spaces and achieving necessary head pressures and flow rates. Once a diameter is determined then manipulation of the number of stages and motor speed are all that are required to meet desired flow conditions. The Versatile Test Reactor (VTR) closed loop cartridge systems will need forced convection cooling independent of the main reactor. A multistage centrifugal pump can meet the necessary flow rates and pumping pressures while minimizing space taken. The pump considered for this work was based off a deep well submersible pump, a variation of a multistage centrifugal pump. We experimented with two pump sizes, 5 cm (2 inch) and 7.5 cm (3 inch) diameters. These diameters were chosen to fit into the inner diameter of standard 5 and 7.5 (2 and 3 inch) Schedule 40 pipe, respectively. This made the design for the test loop both simpler and less expensive as the need for an engineered pump housing was eliminated. Initial test cartridge planning indicated space for only a 5 cm (2 inch) diameter pump, though early testing of this size showed the need for an abnormally high-speed and high-power motor. Fine tuning of the cartridge design allowed a pump size increase to 7.5 cm (3 inches), which was the pump size most extensively tested in this work. The test loop is composed of various sizes of PVC and aluminum piping components in a loop configuration. The pump is driven by a Pittman 250 W (1/3 horsepower) electric motor with maximum speed of 3,450 RPM. Testing consisted of running the pump at a constant motor speed while varying a control valve to restrict flow through the loop, with differential pressure and flow rate recorded. This was done for one and two stage configurations for the 5 cm (2 inch) diameter impeller design and one, two, and three stage configurations for the 7.5 cm (3 inch diameter) impeller design, respectively. Due to pumping power requirements, two and three stage 7.5 cm (3 inch) diameter impeller testing at higher flowrates lowered the motor speed substantially. In regions where motor speed could not be maintained constant, the data were discarded. The test loop was also reconfigured to allow for the pump to be tested for pressure drop in a stalled or inoperable (0 RPM) flow condition. Demonstration of adequate natural convection cooling of the test cartridge fuel type is necessary under accident conditions, and this will depend upon the flow resistance through the impeller assembly when the pump is not operating. Thus, accurate knowledge of the effective impeller assembly loss coefficient is important for safety evaluations. The test loop was modified to provide water inlet and outlets on either side of the pump impeller stack, and a metered flow of lab water was provided in order to measure the pressure drop across the cartridges as a function of flowrate. Data from the pump head curve testing developed as part of this work and supported by analysis using pump head affinity laws indicates that a three stage 7.5 cm (3 inch) pump impeller design will meet target requirements for coolant flow within the VTR cartridge sodium cartridge at full power conditions [1] with margin; this corresponds to a flowrate of 45 l/min (12 gpm) at a pressure drop of 6.1 m (20 feet) of water head. The results of the pressure loss measurements across the impeller assembly when the pump is stationary (i.e., at 0 RPM) indicate that the pressure loss coefficient is 0.921 for a two impeller stack configuration; this value is calculated based on the flow velocity through the minimum available flow area within a single stage of the impeller which corresponds to 1.4 cm2.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simplified Optimum Sizing and Cost Analysis for Compact heat Exchanger in VHTR

In this study, the optimum size of the compact heat exchanger has been developed based on its weight and pumping power for the reference design of 600 MWt very high temperature gas-cooled reactor (VHTR) system. Alloy 617 was selected as a construction material. The optimum size and a number of configurations for the reference design of the VHTR with an intermediate heat exchanger (IHX) were investigated and our initial calculations indicated that it has an unrealistically too large aspect ratio of the length and height due to its small-sized channels, which might cause manifolding problems and a large number of parallel modules with high thermal stress. The flow area and channel diameter were then adjusted to achieve a smaller aspect ratio in this paper. Achievement of this aspect ratio resulted in higher cost, but the cost increase was less than would have occurred by simply reducing the flow area by itself. The appropriate channel diameter is estimated to be less than 5.00 mm for the reference system. The effect of channel waviness enhanced the compactness and heat transfer performance, but unfavorably increased the aspect ratio. Therefore, the waviness should be carefully determined based on performance and economics. In this study, the waviness of the IHX is recommended to be selected between 1.0 and 2.5. Calculations show that reducing the duty dramatically decreases the aspect ratio, indicating that the compact heat exchanger is easy to be optimally designed for low duty, but many modules are required for high duty operation proportional to the operating power. Finally, the effect of working fluids was investigated, and it reveals that using carbon dioxide instead of helium in the secondary side reduces the size and cost by about 20% due to the lower pumping power in spite of its lower heat transfer capability by a factor of 4.

99 GENERAL AND MISCELLANEOUS↗

Λ polarization from vortex rings as the medium response for jet thermalization

We performed a systematic study on the formation of vorticity rings as the process for jet thermalization in the medium created in high-energy nuclear collisions. In this work, we expanded our previous analysis to a more realistic framework by considering noncentral events and fluctuations in the initial condition. We simulate the formation and evolution of the flow vortex structure in a relativistic viscous hydrodynamic model and study the sensitivity of the proposed “ring observable” (ℛ$^{𝑡}_{Λ}$) that can be measured experimentally through the polarization of Λ hyperons. We show that this observable is robust with respect to fluctuating initial conditions to capture the jet-induced vortex flow signal and further study its dependence on different model parameters, such as the jet's velocity, position, the fluid's shear viscosity, and the collision centrality. The proposed observable is associated with the formation of vorticity in a quark-gluon plasma, showing that the measurement of particle polarization can be a powerful tool to probe different properties of jet-medium interactions and to understand better the polarization induced by the transverse and longitudinal expansions of the medium.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Advanced Features and Recent Developments in the WEC-Sim Open-Source Design Tool: Preprint

WEC-Sim is an open-source tool developed in Matlab/Simulink to simulate wave energy converters. WEC-Sim has been developed jointly by the National Renewable Energy Laboratory (NREL) and Sandia National Laboratories (SNL) since its initial release in 2014. WEC-Sim simulations are performed in the time domain based on the radiation and diffraction method using hydrodynamics coefficients derived from boundary element method (BEM)-based frequency-domain potential flow solvers (e.g., WAMIT, NEMOH, Capytaine, or ANSYS-AQWA). Within this level of modeling fidelity, WEC-Sim can handle floating body hydrodynamics, mechanical and electrical power generation methods, advanced control implementation, mooring systems, and other unique applications such as desalination. WEC-Sim functionalities are developed using Simulink blocks and Matlab functions. WEC-Sim is capabilities include simulation of different wave conditions, constraints and PTOs, body dynamics, mooring systems, among other advanced features such as nonlinear hydrodynamics, nonlinear PTOs, body-to-body interactions, etc.

hydrodynamics modeling↗

Comparative Analysis of HEATNETS for Geothermal Network Performance: Preprint

Thermal energy networks (TENs), also known as 5th generation district energy systems, or more specifically geothermal networks when exchanging heat with geothermal boreholes, are an important technology for decarbonization. In these networks an ambient loop connects buildings and thermal sources, such as a borehole field, to exchange energy and maintain a desired loop temperature. Water-source heat pumps are used at the buildings to connect to the ambient or thermal loop to meet to the building heating and cooling loads and maintain comfort. A semi-transient, reduced-order technical model and techno-economic model, called HEATNETS, has been developed at NREL that captures the flow of energy around a TEN. In this work, a comparison of the HEATNETS technical model and a well-known coding platform used for modeling geothermal networks, TRNSYS, has been completed for a proposed geothermal network as a verification process. Hourly data provided from the TRNSYS simulation included building loads, pumping power, heat pump power, temperature entering and leaving the borehole field, and mass flow rates. The hourly borehole temperatures were used to create a linear regression model utilized in HEATNETS to estimate the borehole field heat exchange. The building loads and mass flow rates were direct inputs to HEATNETS while the pumping power, heat pump power, borehole temperatures, and coefficients of performance were all simulated and calculated by HEATNETS, allowing for direct comparison of the thermal energy transfer, rather than also comparing control systems responses. HEATNETS considers the full process from design inputs to economic outputs and can provide modeling options for high-level initial system design and operational optimization. This study shows that HEATNETS, while not intended to replace other modeling tools, can be a unique modeling tool for the performance of a full geothermal network system.

15 GEOTHERMAL ENERGY↗

Impact of U-10Mo HALEU fuel element tolerances on the Massachusetts Institute of Technology reactor safety and operational performance – Thermal hydraulics

The U.S. is coordinating efforts for the conversion of six U.S. High Performance Research Reactors (USHPRR) including one critical facility from highly enriched uranium (HEU) to low-enriched uranium (LEU). In order to continue the mission of these reactors, including the Massachusetts of Institute of Technology Reactor (MITR), and achieve similar performance, high-assay low-enriched uranium (HALEU) with a high-density metallic alloy of uranium with 10 wt% molybdenum (U-10Mo) is being evaluated. The impact of the fabrication specification and tolerances was assessed following the preliminary design of the MITR LEU fuel elements using the U-10Mo monolithic alloy. This research focuses on the analysis of fabrication specification impact on thermal hydraulics (TH) characteristic of the MITR LEU core as a function of the variation of the relevant fuel specification parameters (e.g., coolant channel gap thickness, fuel plate thickness, etc.). The analyses are performed based on an all-fresh LEU fuel conversion plan identified in a preliminary safety analysis report submitted to the Nuclear Regulatory Commission. The reactor power margin to the onset of nucleate boiling (ONB) is assessed under the limiting safety system settings (LSSS), where a scram occurs, to ensure there is sufficient margin to the reactor safety limit, which is defined by the onset of flow instability that occurs after the ONB. The best estimate plus uncertainty approach is employed to analyze this TH characteristic, which yields realistic results while maintaining adequate conservatism, utilizing a statistical uncertainty propagation method with the STAT7 code. The TH characteristic is analyzed as a function of the variability of the specification parameters resulting from the fabrication process. The main findings of this study show that the MITR core can meet the TH safety and operational requirements at the all-LEU initial core startup (cycle 1), selected transition cycles (most reactive cycle and most limiting cycle: cycle 3 and 5, respectively) and equilibrium (cycle 14) cores under all limiting fabrication parameter combinations considered. In addition, the analyses show that the dependency of the core power margin to ONB on those specification parameters that have the most direct impact on TH performance is non-linear but monotonically decreasing within the specification tolerances. The third order polynomial fit curves are reported in detail for selected limiting cases and can serve as a powerful tool for future MITR fuel management in cases such as when HALEU supply is established that may allow additional cycle length or other operational benefits.

Conversion↗

Efficient production of high-energy nonthermal particles during magnetic reconnection in a magnetically dominated ion-electron plasma

Magnetic reconnection is a leading mechanism for dissipating magnetic energy and accelerating nonthermal particles in Poynting-flux-dominated flows. We investigate nonthermal particle acceleration during magnetic reconnection in a magnetically dominated ion–electron plasma using fully kinetic simulations. For an ion–electron plasma with a total magnetization of ${\sigma }_{0}={B}^{2}/(4\pi n({m}_{i}+{m}_{e}){c}^{2})$, the magnetization for each species is ${\sigma }_{i}\sim {\sigma }_{0}$ and ${\sigma }_{e}\sim ({m}_{i}/{m}_{e}){\sigma }_{0}$, respectively. We have studied the magnetically dominated regime by varying σe = 103–105 with initial ion and electron temperatures ${T}_{i}={T}_{e}=5-20{m}_{e}{c}^{2}$ and mass ratio ${m}_{i}/{m}_{e}=1-1836$. Our results demonstrate that reconnection quickly establishes power-law energy distributions for both electrons and ions within several (2–3) light-crossing times. For the cases with periodic boundary conditions, the power-law index is $1\lt s\lt 2$ for both electrons and ions. The hard spectra limit the power-law energies for electrons and ions to be ${\gamma }_{{be}}\sim {\sigma }_{e}$ and ${\gamma }_{{bi}}\sim {\sigma }_{i}$, respectively. The main acceleration mechanism is a Fermi-like acceleration through the drift motions of charged particles. When comparing the spectra for electrons and ions in momentum space, the spectral indices sp are identical as predicted in Fermi acceleration. We also find that the bulk flow can carry a significant amount of energy during the simulations. Finally, we discuss the implication of this study in the context of Poynting-flux dominated jets and pulsar winds, especially the applications for explaining nonthermal high-energy emissions.

79 ASTRONOMY AND ASTROPHYSICS↗

Methodology of Experiment Design for Improving Transient Critical Heat Flux Model Development

One phenomenon that contributes to nuclear fuel and clad failure mechanisms is the departure from nucleate boiling (DNB). Accident scenarios such as reactivity-initiated accidents (RIAs) provide conditions where the frequency of boiling crisis is much more likely to occur and on much shorter time scales than loss of coolant (LOCA) or loss of flow (LOFA) accidents. Here, boiling crisis in the form of DNB is attributed to transient-induced heat flux values that exceed the critical heat flux (CHF). The resulting effects, such as bubble crowding and eventual dryout, can affect flow boiling heat transfer and compromise the structural integrity of nuclear reactor materials. The focus of the work proposed here lies in developing a rigorous process using out-of-pile testing, under simulated RIA conditions, to determine the transient critical heat flux of cladding materials, without contributions from aforementioned radiation-induced effects that have been observed during in-pile experiments. This study provides a road-map for developing and performing experiments that simulate the power profile and energy deposition aspects of transient events, specific to RIAs, on the laboratory scale. The goal of our project is to observe and measure DNB in an annular flow channel around a single heater rod that is operating and nominal thermal hydraulic conditions of a PWR. It is also an aim of these experiments to determine how to quantify the gap between SS and transient CHF cases, based on state-dependent properties of the cladding material type that is being interrogated. Traditionally, CHF is determined as a combination of four factors: hydraulic diameter, system pressure, mass flow, fluid quality. The authors propose that an additional measureable quantity, which is dependent on the structural properties of the cladding material itself, is partly reasonable for the difference between measured and model-developed CHF values. Using a carefully metered approach will allow for several key concepts to be realized: compensation for transient-based effects to current models for CHF; adaptation of current models for different cladding material types, including Gen-IV concept materials; and implementation of a correction factor to account for both power transient-based and radiation-induced effects on the CHF that have not yet been accounted for.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

A Transformational Natural Gas Fueled Dynamic SOFC for Data Center in-Rack Power (Final Technical Report)

Data centers consume 250TWh or 1% of global electricity use in 2019. This electricity demand is expected to grow exponentially in the future. The current data center power supply relies on electric grids with diesel engines and batteries as backup; the latter is critically important because a sudden loss of power could erase crucial data, causing catastrophic economic loss. However, such a double protection architecture is costly, inefficient and polluting. In search for better in-rack power system, fuel-cell based generators have recently emerged as a promising alternative to diesel engines and batteries because of its potential to be more cost-effective, more efficient and less polluting. Among many types of fuel cells, solid oxide fuel cells stand out to be a front runner because of their ability to directly operate on natural gas that has an existing infrastructure. However, there are several critical challenges facing SOFC generators to meet the rigorous power requirements of data centers: high cost, poor reliability and more importantly, slow response to the datacenters’ dynamic load change. The unexpected overload conditions in data centers can cause fuel starvation; the latter can initiate microcracks in the anode structure, thus jeopardizing the lifetime of the SOFC generator. The current efforts to increase transient power capabilities of traditional SOFCs and therefore protect SOFC stacks from internal damage during transient loading, rely primarily upon mathematical algorithms. One of the challenges to these control methodologies is the physical limitations of the fuel delivery system such as slow response of mass flow controllers to fast power demand.

30 DIRECT ENERGY CONVERSION↗