1D Modeling for the Development of a Digital Twin for Hydropower Systems with Applications for a Testing Rig

Modeling and simulation constitute two important parts in constructing a sensible digital twin to mimic the dynamics of hydropower systems. Because of the physical nature of a hydropower system, the basic modeling should cover the water flow systems from the reservoir to the penstock (inlet water pipes), penstock to hydro turbine, and hydro turbine to generator and from the linkage of the hydropower systems to the grid. This report describes initial attempts to model these dynamic components, including the formulation of the linearized state space model for hydro turbine systems using the well-known six-coefficients linearization method and the formulation of the voltage and power dynamical models of a synchronous generator. To validate the accuracy of the proposed model, data collected from Norwegian University of Science and Technology were used to obtain relevant parameters for the model, and the desired simulation results were obtained. Additionally, neural network modeling and learning were also developed and applied to model the generation torque and water flow rate subsystems to demonstrate a potential learning scheme, which can be used in the development of a digital twin.

13 HYDRO ENERGY↗

Sub-Doppler Cooling of a Trapped Ion in a Phase-Stable Polarization Gradient

Trapped ions provide a highly controlled platform for quantum sensors, clocks, simulators, and computers, all of which depend on cooling ions close to their motional ground state. Existing methods like Doppler, resolved sideband, and dark resonance cooling balance trade-offs between the final temperature and cooling rate. A traveling polarization gradient has been shown to cool multiple modes quickly and in parallel, but utilizing a stable polarization gradient can achieve lower ion energies, while also allowing tailorable light-matter interactions in the sub-wavelength regime. In this Letter, we demonstrate cooling of a trapped ion below the Doppler limit using a phase-stable polarization gradient created using trap-integrated photonic devices. At an axial frequency of 2⁢𝜋×1.45 MHz we achieve ⟨𝑛⟩=1.56±0.07 in 150 μ⁢s and cooling rates of ∼0.3 quanta/μ⁢s. Here, we examine ion dynamics under different polarization gradient phases, detunings, and intensities, showing reasonable agreement between experimental results and a multilevel model. Cooling is fast and power efficient, with lower average motional Fock state occupation when compared to simulated operation under the corresponding running wave configuration. Our results demonstrate a well-controlled test bed for studying the dynamics of multilevel atomic systems in a phase-stable polarization gradient.

Atom & ion cooling↗

Embedded, Real-Time, and Distributed Traveling Wave Fault Location Method Using Graph Convolutional Neural Networks

This work proposes and develops an implementation of a fault location method to provide a fast and resilient protection scheme for power distribution systems. The method analyzes the transient dynamics of traveling waves (TWs) to generate features using the discrete wavelet transform (DWT), which are then used to train several graph convolutional network (GCN) models. Faults are simulated in the IEEE 34-node system, which is divided into three protection zones (PZs). The goal is to identify the PZ in which the fault occurs. The GCN models create a distributed protection scheme, as all nodes are able to retrieve a prediction. Given that message-passing between nodes occurs both during training and in the execution of the model, the resiliency of such schemes to communication losses was analyzed and demonstrated. One of the models, which only uses voltage measurements, was implemented on a Texas Instruments F28379D development board. The execution times were monitored to assess the speed of the protection scheme. It is shown that the proposed method can be executed in approximately a millisecond, which is comparable to existing TW protection in the transmission system. For experimental purposes, a DWT-based detection method is employed. A design of a setup to playback TWs using two development boards is also addressed.

Jiménez-Aparicio, Miguel (ORCID:000000016864461X)↗

Asynchronous Grid Connections Providing Fast-Frequency Response: System Integration Study

This paper presents an integration study for the recent power electronic-based fast-frequency response technology, "asynchronous grid connection" which operates as an aggregator for behind-the-meter resources and distributed generators. Both technical feasibility and techno-economic viability studies are presented. The fast-frequency response characteristics, validated against Power Hardware-in-the-Loop experiments, are integrated into an IEEE 9- bus system in DigSilent PowerFactory for system-level dynamic analysis. It demonstrates that droop-based control enhancements to local distributed generators allow their aggregation to provide grid-supporting functionalities and participate in the ancillary service markets. To this end, a long-term simulation embedding the system within the ancillary service market framework of PJM has been performed. The fast-frequency response regulation is subsequently used to calculate the potential revenue and project the results on a 15-year investment horizon. Finally, the techno-economic analysis provides recommendations for enhancements to access the full potential of distributed generators on a technical and regulatory level.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Modeling of Induction Motors and Variable Speed Drives for Multi-Domain System Simulations Using Modelica and the OpenIPSL Library

This paper introduces an innovative method for characterizing, implementing, and validating both three-phase and single-phase induction motor models, accompanied by a variable speed drive model. The primary goal is to investigate interactions between the electrical power grid and other dynamic domains (e.g., thermofluidic) that impact motor/load drive behavior. Our approach involves establishing a mechanical interface based on a physically meaningful equation linking motor torque/speed to the electrical model in the phasor domain. This allows seamless integration of diverse domain subsystems into a unified multi-domain model using Modelica v4.0.0 and the OpenIPSL library v3.0.1, overcoming co-simulation limitations. The proposed model, which requires only one Modelica-compliant tool for simulation, introduces additional dynamics through the mechanical interface, enabling explicit simulation of load disturbances based on constitutive physics. This deepens our understanding of dynamic interactions between the electrical power domain and other subsystems connected through the motor. We detail the modeled components using mathematical equations and textual descriptions, emphasizing the Modelica modeling approach. Simulation examples validate the implementation, demonstrating the multi-domain modeling capabilities of the newly developed components.

Computer Science↗

A Comprehensive Method to Mitigate Forced Oscillations in Large Interconnected Power Grids

Multiple severe forced oscillation events have recently been observed across the North American interconnections and around the world. These forced oscillations have caused power swings, limited power transfer capability, damaged equipment, and persisted indefinitely until the driving source was located and removed. This paper proposes a comprehensive method to mitigate forced oscillations. Once a forced oscillation is detected, a new source location algorithm can be used to locate the source based on the oscillation mode angle without requiring system topology information. If the source cannot be quickly located and removed, a control strategy can be activated to modulate the active power of utility-scale inverterbased battery energy storage systems (BESSs) to reduce the energy of forced oscillations to a safe level and allow sufficient time for locating the exact source. The proposed source location algorithm is validated using measurements collected during the January 11, 2019 forced oscillation event in North America and other actual grid events, while the proposed control strategy is verified using the Eastern Interconnection dynamic model under the replicated January 11, 2019 forced oscillation event. The simulation results demonstrated that the proposed source location algorithm can accurately identify the forced oscillation source, and the proposed control strategy can significantly reduce forced oscillation energy.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Integrated Optimization and Control of a Hybrid Gas Turbine/sCO 2 Power System

During phase-I, the project team led by Echogen Power Systems (EPS) had two primary objectives based on investigating the application of gas turbines with supercritical carbon dioxide (sCO 2 ) power cycles. The first objective was to improve the overall efficiency and performance of a hybrid gas turbine/sCO 2 power system through a joint optimization of the two subsystems (gas turbine and sCO 2 power cycle) using non-linear optimization techniques that simultaneously evaluate thermal performance of the combined cycle. The hybrid power system included several points of interaction, including (but not limited to) gas turbine exhaust, fuel heating, inlet chilling and turbine cooling. The second objective was to establish a baseline transient response model of the hybrid power system and a notional microgrid and begin steps to integrate the control systems of the three major elements (gas turbine, sCO 2 cycle and grid controller). The project team established a baseline performance for a combined cycle power plant using a production gas turbine and scaled sCO 2 power cycle only utilizing exhaust heat recovery. Echogen’s non-linear techno-economic optimization code was extended by adding gas turbine component models derived from a in-house developed gas turbine design code. With the two cycles coupled by the gas turbine exhaust, design parameters of both cycles were allowed to vary simultaneously to determine performance opportunity versus isolated designs. Returning to the baseline gas turbine/sCO 2 power cycle transient models: Echogen had in-house developed sCO 2 cycle transient model in GT-Suite system simulation software, and had partnered with Siemens Finspång for gas turbine transient model, and Siemens PTI group to provide micro-grid load profile as well as hybrid power cycle generated load (power and frequency) analysis. The transient model for the SGT-750 Siemens gas turbine was a “black-box” functional mock-up interface (FMI) model developed by Siemens Industrial Turbomachinery in Finspång, Sweden. The SGT-750 is a twin-shaft gas turbine that produces 40 MW electricity with an efficiency of about 40% at ISO conditions. At 100% gas turbine throttle (load), the SGT-750 has average exhaust conditions of 114.6 kg/s and 469.8°C. The transient model for sCO 2 power cycle was developed by Echogen in GT-SUITE 1D system simulation software platform. The basic CO 2 flow circuit has single-shaft turbomachinery with net 11.5 MW electrical power output at design conditions. The power turbine has a double-ended shaft with one end connected to synchronous generator through a fixed-ratio gearbox. The other end of power turbine is connected to the compressor through a continuously variable transmission. The major components of the sCO 2 power cycle modeled include air cooled condenser/cooler, CO 2 compressor, recuperator, two waste heat exchanger coils, power turbine, continuous variable transmission, gearbox and generator. Integration of SGT-750 transient model and sCO 2 power cycle transient model was done in Matlab Simulink. In the integrated model, the gas turbine and sCO 2 power cycle interacted at two points, first one being the gas turbine exhaust gas flow rate and temperature, which were inputs to sCO 2 power cycle model. The second point was the distribution of micro-grid load demand signal between the SGT-750 generator and sCO 2 cycle generator. For a given combined-cycle load demand, the gas turbine load demand was equal to the total demand minus the sCO 2 cycle power generated. In the present study the integrated model was simulated for two cases of grid load demand: (i) for a step change, both positive-step and negative-step, in grid load demand (ii) for a micro-grid load demand curve provided by Siemens PTI group. Finally, the time series plots representing load demand versus integrated system response were presented including the sCO 2 power cycle control system performance plots. The actual generated power and frequency of both the generators, gas turbine and sCO 2 power cycle, was supplied to Siemens PTI group for dynamic grid assessment, results of which are provided in appendices.

03 NATURAL GAS↗

Learning-Based Load Control to Support Resilient Networked Microgrid Operations

Microgrids have proven to be an effective option for increasing the resiliency of critical end-use loads during extreme events. Building on past operational experiences, some microgrid operators are examining the potential to network microgrids to further improve resiliency. However, the frequency deviations experienced on isolated microgrids during transient events, such as switching operations, step increases in load, and loss of generation, are significantly larger than those typically seen on bulk transmission systems. The larger frequency deviations can cause a loss of inverter-connected assets, resulting in a loss of power to critical end-use loads. This paper presents a method of mitigating the impact of transient events by engaging end-use loads using Grid-Friendly Appliance TM (GFA) controllers. An online, i.e., real-time, device-level algorithm is presented, which adjusts individual GFA controller frequency set-points based on the operational characteristics of each end-use load, and on the changing grid dynamic characteristics. The presented method improves the dynamic stability of the networked microgrid operations while minimizing the interruptions to end-use loads. The presented work is validated with dynamic simulations using a modified version of the IEEE 123-node test system with three microgrids, using the GridLAB-D TM simulation environment.

Radhakrishnan, Nikitha↗

Rapid Quantum Ground State Preparation via Dissipative Dynamics

Inspired by natural cooling processes, dissipation has become a promising approach for preparing low-energy states of quantum systems. However, the potential of dissipative protocols remains unclear beyond certain commuting Hamiltonians. This work provides significant analytical and numerical insights into the power of dissipation for preparing the ground state of noncommuting Hamiltonians. For quasi-free dissipative dynamics, including certain 1D spin systems with boundary dissipation, our results reveal a new connection between the mixing time in trace distance and the spectral properties of a non-Hermitian Hamiltonian, leading to an explicit and sharp bound on the mixing time that scales polynomially with system size. For more general spin systems, we develop a tensor network-based algorithm for constructing the Lindblad jump operator and for simulating the dynamics. Using this algorithm, we demonstrate numerically that dissipative ground state preparation protocols can achieve rapid mixing for certain 1D local Hamiltonians under bulk dissipation, with a mixing time that scales logarithmically with the system size. We then prove the rapid mixing result for certain weakly interacting spin and fermionic systems in arbitrary dimensions, extending recent results for high-temperature quantum Gibbs samplers to the zero-temperature regime. Together, these results show that dissipation can be a powerful tool for ground state preparation, with potential applications across condensed matter physics, quantum materials science, and beyond.

decoherence↗

Community-Centric Microgrid Feasibility Analysis Framework to Accelerate Resilience of Island Communities

Marine energy offers a reliable energy solution for island and coastal communities, which often lack traditional local generation, to support their transition to energy independence and reduce reliance on externally imported fuels. Successful deployment of new technologies in these isolated locations requires community acceptance and approval from the outset, as these communities typically lack the financial and technical resources to operate and maintain new systems. This report presents a community-centric microgrid planning framework for remote coastal and island communities. Community engagement is integrated as the first step in the planning process, incorporating community profiles and visions into energy development scenarios. A case study was conducted in St. George, Pribilof Islands, Alaska, which relies entirely on diesel yet has significant wind and wave energy potential. Community engagement revealed a unique history and current economic status, with an interest in adopting advanced energy technologies despite past failures. Various microgrid configurations were optimized, considering different technologies to meet current and future energy needs while balancing cost and energy resilience. Wave energy converters (WECs) were a key component, integrated with other energy sources using the Xendee optimization tool. The Marine Energy Microgrid Toolkit, developed as part of this work, uses commercial power system analysis tools to optimize and analyze microgrid scenarios. The developed framework and toolkit can be applied to island and coastal communities to enhance resilience and support microgrid deployments. Future enhancements will include incorporating new marine resources, developing dynamic models, and automating the integration of Xendee and PowerFactory simulations.

02 PETROLEUM↗

Modeling of Inductive Constant Power Load for Electromagnetic-Transient Simulations-Part II

This paper improves the dynamic constant power (CP) load model that was published in Part I, which is appropriate for electromagnetic-transient (EMT). The improved model conserves all features of its predecessor. For instance, it maintains a fixed power consumption (both active and reactive parts) and a fixed power factor for loads that are predominantly inductive. Furthermore, as the proposed model is a time-dependent system, it is applicable to both sinusoidal and non-sinusoidal case studies. However, the previous model cannot be easily integrated with numeric solvers because it simulated load data over one cycle all together, not sequentially in a time-step manner, due to the limitation involved with the power factor. The improved version, on the contrary, allows the load to be simulated at every time step, which would facilitate its integration with numeric solvers. The model's validity is confirmed by comparing its response with data that is synthesized from constant impedance load, and the result is satisfactory.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Peak load reduction and load shaping in HVAC and refrigeration systems in commercial buildings by using a novel lightweight dynamic priority-based control strategy

Reducing peak power demand in a building can reduce electricity expenses for the building owner and contribute to the efficiency and reliability of the electrical power grid. For the building owner, reduced expenses come from the reduction or elimination of peak power charges on electricity bills. For the power system operator, reducing peak power demand leads to a more predictable load profile and reduces stress on the electric grid system. Herein we present a computationally inexpensive, dynamic, and retrofit-deployable control strategy to effect peak load reduction and load shaping. The effectiveness of the control strategy is examined in a simulation with 80 air-conditioning units and 40 refrigeration units. The results show that a peak demand reduction of 60 kW can be achieved relative to peak demand in a typical set point–based approach. The proposed strategy was deployed in a gymnasium building with four rooftop HVAC units, where it showed over 15% peak demand (kW) reduction savings while maintaining or lowering energy consumption (in kilowatt-hours) relative to the set point–based thermostat controls.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data-Driven Approach for Uncertainty Propagation and Reachability Analysis in Dynamical Systems

In this paper, we propose a data-driven approach for uncertainty propagation and reachability analysis in a dynamical system. The proposed approach relies on the linear lifting of a nonlinear system using linear Perron-Frobenius (P-F) and Koopman operators. Here, the uncertainty can be characterized in terms of the moments of a probability density function. We demonstrate how the P-F and Koopman operators are used for propagating the moments. Time-series data is used for the finite-dimensional approximation of the linear operators, thereby enabling data-driven approach for moment propagation. Simulation results are presented to demonstrate the effectiveness of the proposed method.

42 ENGINEERING↗

Power System Operational Impacts of Electric Vehicle Dynamic Wireless Charging

The electrification of the transportation sector poses an opportunity for reducing greenhouse gas (GHG) emissions from passenger vehicles. Electric vehicle (EV) charging through dynamic wireless power transfer (DWPT), known as roadway electrification, could shift EV demand profiles to better coincide with renewable electricity generation. However, this would be a very large new load and few studies evaluate the regional impacts of DWPT charging in a power transmission system. This paper defines methods that address dataset generation for passenger vehicle trips and models to evaluate regional impacts for this emerging technology. Household vehicle miles traveled (VMT) data form localized EV demand profiles through discrete-event simulation. This data serves as exogenous inputs for a Production Cost Model (PCM) of a synthetic transmission system based on the Electric Reliability Council of Texas's (ERCOT) network. EV charging methods are compared for both a 2018 baseline generation mixture and a high-renewable generation case incorporating 20 GW of installed solar photovoltaic (PV) capacity. The PCM employs unit commitment and economic dispatch (UC&ED) models to compare financial, environmental, and grid reliability impacts from EV charging across passenger EV adoption levels. In-transit charging could reduce grid operational costs by as much as 1.49%, with up to $13.7B saved in annual vehicle operational costs for consumers compared to gas-powered vehicles. Health impacts analysis from power plant and vehicle tailpipe emissions from this study show net health benefits increase by 40% for in-transit charging coupled with high renewable generation. Renewable resources provide an avenue for cost-effective in-transit charging with reduced emissions. The combination of dataset generation and open-source power system modeling establish a foundation for the holistic evaluation of regional DWPT impacts.

dynamic wireless power transfer↗

Observability Analysis of a Power System Stochastic Dynamic Model Using a Derivative-Free Approach

Serving as a prerequisite to power system dynamic state estimation, the observability analysis of a power system dynamic model has recently attracted the attention of many power engineers. However, because this model is typically nonlinear and large-scale, the analysis of its observability is a challenge to the traditional derivative-based methods. Indeed, the linear-approximation-based approach may provide unreliable results while the nonlinear-technique-based approach inevitably faces extremely complicated derivations. Furthermore, because power systems are intrinsically stochastic, the traditional deterministic approaches may lead to inaccurate observability analyses. In this work, facing these challenges, we propose a novel polynomial-chaos-based derivative-free observability analysis approach that not only is free of any linear approximations, but also accounts for the stochasticity of the dynamic model while bringing a low implementation complexity. Furthermore, this approach enables us to quantify the degree of observability of a stochastic model, what conventional deterministic methods cannot do. The excellent performance of the proposed method has been demonstrated by performing extensive simulations using a synchronous generator model with IEEE-DC1A exciter and the TGOV1 turbine governor.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Transient Modeling and Simulation of a Generic Stable Salt Reactor

A SAM system-level model of a generic stable salt reactor has been developed to investigate thermal-hydraulic behavior and safety performance under steady and transient conditions. The model integrates information generated from a reactor physics analysis using PROTEUS and PERSENT, and a computation fluid dynamics (CFD) analysis using STAR-CCM+. A loose, iterative coupling scheme between PROTEUS and SAM is implemented to calculate the equilibrium power and temperature distributions in the steady-state critical core condition. The converged steady-state model is then used in PERSENT to calculate the four reactivity feedback temperature coefficients (Doppler, fuel density, coolant density, and core radial expansion) and kinetic parameters that are needed in SAM to model the temperature feedback effects in transient simulations. Within the fully enclosed liquid fuel pins, natural convection is the dominant heat transfer mechanism. The STAR-CCM+ model of the fuel pin considers conjugate heat transfer from the liquid fuel salt to the pin cladding and external reactor coolant. The CFD results of the axial and radial temperature profiles are used to empirically determine an effective fuel salt thermal conductivity in the SAM fuel pin model so that the temperatures predicted by the SAM model match as closely as possible the CFD results. In the central region of the fuel pin, the effective thermal conductivity is as high as similar to 60 times the physical fuel salt thermal conductivity. The whole-plant SAM model is then used to simulate an unprotected station blackout transient. The results of this simulation showed that the large negative fuel axial expansion reactivity feedback reduces fission power to similar to 2.4% nominal power. The core is cooled by natural circulation, which removes heat in the core to the emergency heat removal system, and ultimately, to the ambient. However, peak fuel salt and cladding temperatures can potentially reach as high as 1500 K, albeit briefly, if the shutdown mechanism fails to operate.

stable salt reactor; transient simulations; system↗

Third-body stabilization of supercritical CO 2 in CO oxidation: development and application of a ReaxFF force field for the CO/O/CO 2 system

Supercritical CO 2 (scCO 2 ) plays a crucial role as a solvent in separation processes, advanced power cycles, and materials processing. Nonetheless, the atomistic comprehension of how the dense scCO 2 matrix influences the fundamental reaction of carbon monoxide (CO) is still insufficiently explored. Experimental studies and molecular dynamics (MD) simulations frequently fail to detect the highly reactive, transient intermediates, such as atomic oxygen (O), that drive these reactions. Here, to address this issue, we have developed a novel ReaxFF reactive force field for the CO 2 /CO/O system. The force field parameters were calibrated using density functional theory and second-order Møller-Plesset calculations to model CO 2 crystal properties, intermolecular interactions, bond dissociation curves, and reaction energy barriers. The force field reproduces the cohesive energy of the CO 2 crystal, the pressure characteristics of bulk scCO 2 , the equation-of-state behavior over a wide pressure–density range, the pressure dependence of the C–O bond length under compression, and the structural properties of liquid and scCO 2 , as documented by experiments, ab-initio MD, and prominent non-reactive models. The force field was subsequently applied to study the CO + O → CO 2 reaction. In a dilute environment, the reaction is inefficient as the newly formed CO 2 rapidly dissociates due to excess kinetic and potential energy acquired from the exothermic reaction. Conversely, in a dense scCO 2 environment, the surrounding matrix acts as an efficient third body, stabilizing the emerging CO2 product via molecular collisions. Statistical analysis confirms an average excess energy dissipation of 133.9 ± 3.6 kcal/mol over 112.4 ± 17.9 ps. Kinetic energy decomposition reveals that ∼ 92% of the excess kinetic energy is stored in internal (rotational and vibrational) degrees of freedom. This ReaxFF force field establishes a mechanistic foundation for third-body stabilization in dense reactive environments.

Chowdhury, Emdadul Haque [Pennsylvania State Univ.↗

Large-Eddy Simulation Study of Flow and Combustion Dynamics in a Full-Scale Hydrogen–Air Rotating Detonation Combustor-Stator Integrated System

In the present work, a first-of-its-kind three-dimensional (3D) large-eddy simulation (LES) study is conducted to numerically investigate the combustion dynamics as well as aero-thermal phenomena in a full-scale nonpremixed hydrogen–air rotating detonation engine (RDE) (with a diverging-shaped lower-end wall), when integrated with nozzle guide vanes (NGV) acting as the turbine stator. The wall-modeled LES framework incorporates hydrogen–air detailed chemical kinetics and adaptive mesh refinement (AMR). A comparative analysis is carried out for two operating conditions with different fuel/air mass flow rates but global equivalence ratio of unity, and considering RDE configurations without and with stator. The LES model is validated against available experimental data for the low mass flux condition with respect to detonation wave speed/height, wave dynamics, and axial static pressure distribution. Numerical results indicate significant deflagrative combustion occurring in the fill region near the inner wall due to formation of recirculation zones in the injection near-field driven by the backward facing step. The leading detonation wave is found to be trailed by an azimuthal reflected-shock combustion (ARSC) wave, consistent with experimental observations, which consumes unburned vitiated reactants that leak through the main detonation wave. The main detonation wave characteristics, such as detonation wave speed/height and combustion efficiency, do not change appreciably with the presence of NGV. A novel combustion diagnostic technique based on chemical explosive mode analysis (CEMA) is employed to quantify the fraction of heat release occurring in the detonative mode versus deflagrative mode for the simulated conditions. The exit flow is found to be nearly fully subsonic and supersonic for the low and high mass flux conditions, respectively. Further analysis of the exit flow profiles shows that the presence of NGV renders the flow more axial and significantly impacts the exit Mach number and total pressure, while the total temperature shows negligible change. In addition, the low mass flux operating point, despite exhibiting more deflagrative losses within the combustor, yields overall lower pressure drop from plenum to exhaust, which is mainly attributed to lower pressure drop across the injectors. Lastly, the rotating detonation engine-nozzle guide vanes (RDE-NGV) configuration exhibits higher total pressure loss compared to rotating detonation engine (RDE) without stator across both the mass flux conditions. In conclusion, this study extends the state-of-the-art in numerical modeling of pressure gain combustion (PGC) systems by demonstrating high-fidelity 3D reacting LES of full-scale RDE-NGV systems relevant to RDE-turbine integration for stationary power generation.